• Title/Summary/Keyword: frequency component ratio

Search Result 182, Processing Time 0.022 seconds

The Effects of Manual Passive Exercise Performed by Physical Therapists on Autonomic Nervous System (물리치료사에 의해서 실시되는 도수수동 운동이 자율신경계에 미치는 영향)

  • Kim, In-Bae;Kim, Chung-Yoo;Kim, Eun-Kyung;Shin, Han-Ki;Kang, Jong-Ho
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.10 no.1
    • /
    • pp.9-14
    • /
    • 2015
  • PURPOSE: The purpose of this study was to investigate the effects of ten minutes of manual passive exercise performed by physical therapists on autonomic nervous system. METHODS: Thirty-five healthy adults, both male and female, were chosen as subjects for this study. The autonomic nervous system was measured by heart rate variability (HRV),before and after passive exercise using the following measurements: mean heart rate (mean HRT), low frequency (LF) and high frequency (HF) components, the LF/HF ratio, root mean square of the successive differences (RMSSD), and the HRV index. The exercise was performed on the subjects by a physical therapist with seven years of experience specializing in the nervous system. The exercise was conducted at the mid-range of motion on the upper and lower limbs of the subjects for two minutes and thirty seconds and for a total of ten minutes. RESULTS: There was a significant increase in the LF component. The mean HRT and the LF/HF ratio both increased, but these increases were not significant. The HF component, RMSSD, and HRV index all decreased, but these decreases were not significant. CONCLUSION: In conclusion, mid-range manual passive exercise does not induce stress on the autonomic nervous system. It can safely be performed by a physical therapist.

Analysis of Aroma Pattern for Geographical Origin of Red Ginseng Concentrated by Electronic Nose (전자코를 이용한 홍삼 농축액의 원산지 판별을 위한 향기패턴 분석)

  • Hur, Sang-Sun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.1
    • /
    • pp.38-48
    • /
    • 2020
  • The aroma pattern was analyzed using electronic nose to examine the possibility of origin discrimination according to the mixing ratio of Chinese and Korean red ginseng concentrates. The origin of Chinese red ginseng concentrate and Korea red ginseng concentrate could be distinguished and the pattern of aroma component detected decreased as the mixing ratio of Chinese red ginseng concentrate increased. Cultivar and habitat of Korean red ginseng concentrated was remarkably distinguished by the chromatogram of frequency pattern, derivative pattern and visual pattern using olfactory images known as vapor printTM.

Evaluation of pulse effect on frequency content of ground motions and definition of a new characteristic period

  • Yaghmaei-Sabegh, Saman
    • Earthquakes and Structures
    • /
    • v.20 no.4
    • /
    • pp.457-471
    • /
    • 2021
  • This study aims at providing a simple and effective methodology to define a meaningful characteristic period for special class of earthquake records named "pulse-like ground motions". In the proposed method, continuous wavelet transform is employed to extract the large pulse of ground motions. Then, Fourier amplitude spectra obtained from the original ground motion and the residual motion is simply compared. This comparison permits to define a threshold pulse-period (Tp∗) as the threshold period above which the pulse component has negligible contributions to the Fourier amplitude spectrum. The effect of pulse on frequency content of motions was discussed on the light of this definition. The advantage and superior features of the new definition were related to the inelastic displacement ratio (IDR) for single-degree-of-freedom systems with period equal to one half of the threshold period. Analyses performed for the proposed period at three ductility levels u=2,4,6 were compared with the results obtained at half of pulse period derived from wavelet analysis, peak-point method and the peak of product of the velocity and the displacement response spectra (Sv x Sd). According to the results, pulse effects on inelastic displacement ratio seem to be more important when $\frac{T_p^*}{T}=2$ (T is the fundamental vibration period of system). The results showed that utilizing of the proposed definition could facilitate an enhanced understanding of pulse-like records features.

SNR Improvement of AE Signal for Detection of Gas Leak from Tubes under Vibratory Environment

  • Lee, Tae-Hun;Jhang, Kyung-Young;Kim, Jung-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.3
    • /
    • pp.262-267
    • /
    • 2007
  • Detection of gas leak from a tube is a very important issue in the quality control of machines such as the heat exchanger of an air-conditioner, because leakage of operating gas directly reduces the performance of machines. The acoustic emission (AE) method is a common way to detect leak of gas, however its application under the environment of mechanical vibration is restricted since most AE detectors are very sensitive to external vibration noise. In order to overcome this problem, we propose a method based on the mode analysis of the Lamb wave. In this method, the dominant Lamb mode and its frequency are found first, and then a proper band-pass filter is used to retain only this frequency component. In this way, we could improve the SNR (signal-to-noise ratio) of AE signal generated by gas leak from the tube even under vibratory environment.

Post-Processing with Frequency Domain Wiener Filter for Blind Source Separation

  • Park, Keun-Soo;Park, Jang-Sik;Kim, Hyun-Tae;Son, Kyung-Sik
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.2E
    • /
    • pp.36-42
    • /
    • 2006
  • In this paper, a novel post processing using Wiener filtering technique is proposed to p rm further interference reduction in FDICA. Using the proposed method, the target signal components are remained with little attenuation while the interference components are drastically suppressed. The results of experiments show that the proposed method achieves a reduction of the residual crosstalk. Compared to the NLMS method, the proposed method has slightly better separation performance in SIR, and even requires much less computational complexity.

Loop-loop EM inversion and its applicability to subsurface exploration

  • Sasaki, Yutaka
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.3-6
    • /
    • 2006
  • There are three types of frequency-domain loop-loop EM induction method, depending on the loop separation and their location relative to the ground surface: horizontal-loop EM (HLEM), fixed small-loop EM, and helicopter-borne EM (HEM) methods. Multidimensional inversion provides tomographic images of the subsurface resistivity structure and thus enhances the interpretational accuracy of loop-loop EM data. HLEM method is shown to be effective for exploring groundwater resources in weathered and fractured crystalline basement terrains in semi-arid regions. Also, HEM method is useful for locating weak zones in landslide areas. The applicability of inversion to small-loop EM data depends solely on the S/N ratio. The quadrature response of small-loop EM data can only give the equivalent conductivity of a homogenous half-space model, and thus the in-phase component is essential in inverting EM data. However, the in-phase response is much lower and decreases more rapidly with decreasing frequency than the quadrature response. Further work is needed to obtain conductivity-depth images from small-loop EM data.

  • PDF

A Study on Performance Improvement of Active Noise Control Using Synchronous Sampling Method (동기화한 이산화법을 이용한 능동소음제어의 성능향상에 관한 연구)

  • Kim, Heung-Seob;Oh, Jae-Eung;Shin, Joon
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.10
    • /
    • pp.2523-2532
    • /
    • 1994
  • In this paper, active noise control is performed in a duct system using the periodic pulse train which corresponds to the periodic component of noise source as a reference signal. Control algorithm applied in this study is possible to eliminate the acoustic feedback which occurs in the conventional filtered-x and filtered-u LMS algorithm by using electrical reference signal and has the fast adaptation speed with low filter orders by using synchronous sampling method is discussed via computer simulations and experiments of case studies such as frequency modulation, amplitude modulation and frequency differency between source signal and reference signal.

Microphone Array Based Speech Enhancement Using Independent Vector Analysis (마이크로폰 배열에서 독립벡터분석 기법을 이용한 잡음음성의 음질 개선)

  • Wang, Xingyang;Quan, Xingri;Bae, Keunsung
    • Phonetics and Speech Sciences
    • /
    • v.4 no.4
    • /
    • pp.87-92
    • /
    • 2012
  • Speech enhancement aims to improve speech quality by removing background noise from noisy speech. Independent vector analysis is a type of frequency-domain independent component analysis method that is known to be free from the frequency bin permutation problem in the process of blind source separation from multi-channel inputs. This paper proposed a new method of microphone array based speech enhancement that combines independent vector analysis and beamforming techniques. Independent vector analysis is used to separate speech and noise components from multi-channel noisy speech, and delay-sum beamforming is used to determine the enhanced speech among the separated signals. To verify the effectiveness of the proposed method, experiments for computer simulated multi-channel noisy speech with various signal-to-noise ratios were carried out, and both PESQ and output signal-to-noise ratio were obtained as objective speech quality measures. Experimental results have shown that the proposed method is superior to the conventional microphone array based noise removal approach like GSC beamforming in the speech enhancement.

Design of A High Energy Density Pulse Transformer (고 에너지 밀도 펄스 변압기 설계)

  • Nam, S.H.;Park, S.S.;Ha, K.M.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2186-2188
    • /
    • 1999
  • A high frequency and energy density pulse transformer is a critical component of a high voltage power supply in a traveling wave tube (TWT) amplifier system. In this paper, processes of design, manufacturing, and test of the transformer are discussed. Primary voltage of the transformer is 240 V. The transformer secondary have two outputs which are 4100 V (Helix) and 2050 V (Collector). Total output power is 860 W. Normal operating frequency of the transformer is 10 kHz. In high energy density pulse transformers, temperature rise is a main problem during its operation. From our study, it was found that resonant current due to leakage inductance and stray capacitance was the main cause of temperature rise. This happens because of the inherently high turn-ratio in high voltage transformers. Solutions to reduce stray components are presented.

  • PDF

A Study on the Characteristic of Natural Frequencies of Railway Open Deck Plate Girder Bridges (철도 무도상판형교의 고유진동특성에 대한 연구)

  • 오지택;최진유;김현민
    • Proceedings of the KSR Conference
    • /
    • 2002.10b
    • /
    • pp.1041-1046
    • /
    • 2002
  • A railway open deck plate girder bridge without ballast should support relatively heavier vehicle loads compared with its self-weight. For such a reason, actual dynamic response of the bridge is considerably differing with normal prediction because additional masses added from vehicle to a bridge have an effect on the dynamic characteristics of the bridge. These differences affect to the estimation of a natural frequency change that adopted for one of the evaluation technique of strength decrease, and these make trouble to the analysis of a natural frequency from the field test data that measured at the bridge subjected to a running vehicle. In this study, classification of mass participation ratio for each component of open deck plate girder bridge without ballast and the comparison according to the change of vibration characteristics for the case of subjected to a running vehicle were accomplished.

  • PDF