• 제목/요약/키워드: free ends

검색결과 155건 처리시간 0.023초

Computational and mathematical simulation for the size-dependent dynamic behavior of the high-order FG nanotubes, including the porosity under the thermal effects

  • Huang, Xiaoping;Shan, Huafeng;Chu, Weishen;Chen, Yongji
    • Advances in nano research
    • /
    • 제12권1호
    • /
    • pp.101-115
    • /
    • 2022
  • Some researchers pointed out that the nonlocal cantilever models do not predict the dynamic softening behavior for nanostructures (including nanobeams) with clamped-free (CF) ends. In contrast, some indicate that the nonlocal cantilever models can capture the stiffness softening characteristics. There are substantial differences on this issue between them. The vibration analysis of porosity-dependent functionally graded nanoscale tubes with variable boundary conditions is investigated in this study. Using a modified power-law model, the tube's porosity-dependent material coefficients are graded in the radial direction. The theory of nonlocal strain gradients is used. Hamilton's principle is used to derive the size-dependent governing equations for simply-supported (S), clamped (C) and clamped-simply supported (CS). Following the solution of these equations by the extended differential quadrature technique, the effect of various factors on vibration issues was investigated further. It can be shown that these factors have a considerable effect on the vibration characteristics. It also can be found that our numerical results can capture the unexpected softening phenomena for cantilever tubes.

Orienting the superficial inferior epigastric artery (SIEA) pedicle in a stacked SIEA-deep inferior epigastric perforator free flap configuration for unilateral tertiary breast reconstruction

  • Yu, Ya-han;Ghorra, Dina;Bojanic, Christine;Aria, Oti N.;MacLennan, Louise;Malata, Charles M.
    • Archives of Plastic Surgery
    • /
    • 제47권5호
    • /
    • pp.473-477
    • /
    • 2020
  • Superficial inferior epigastric artery (SIEA) flaps represent a useful option in autologous breast reconstruction. However, the short-fixed pedicle can limit flap inset options. We present a challenging flap inset successfully addressed by de-epithelialization, turnover, and counterintuitive rotation. A 47-year-old woman underwent left tertiary breast reconstruction with stacked free flaps using right deep inferior epigastric perforator and left SIEA vessels. Antegrade and retrograde anastomoses to the internal mammary (IM) vessels were preferred; additionally, the thoracodorsal vessels were unavailable due to previous latissimus dorsi breast reconstruction. Optimal shaping required repositioning of the lateral ends of the flaps superiorly, which would position the ipsilateral SIEA hemi-flap pedicle lateral to and out of reach of the IM vessels. This problem was overcome by turning the SIEA flap on its long axis, allowing the pedicle to sit medially with the lateral end of the flap positioned superiorly. The de-epithelialized SIEA flap dermis was in direct contact with the chest wall, enabling its fixation. This method of flap inset provides a valuable solution for medializing the SIEA pedicle while maintaining an aesthetically satisfactory orientation. This technique could be used in ipsilateral SIEA flap breast reconstructions that do not require a skin paddle, as with stacked flaps or following nipple-sparing mastectomy.

4계 상미분방정식에 의한 변단면 Timoshenko 보의 자유진동 (Free Vibrations of Tapered Timoshenko Beam by using 4th Order Ordinary Differential Equation)

  • 이병구;박광규;이태은
    • 한국전산구조공학회논문집
    • /
    • 제25권3호
    • /
    • pp.185-194
    • /
    • 2012
  • 이 연구는 회전관성과 전단변형을 동시에 고려한 변단면 Timoshenko 보의 자유진동에 관한 연구이다. 변단면 보의 단면은 폭이 포물선 함수로 변화하는 변화폭 직사각형 단면으로 채택하였다. 이러한 보의 자유진동을 지배하는 수직변위에 대한 4계 상미분방정식을 유도하였다. 이 상미분방정식을 수치해석하여 고유진동수와 진동형을 산출하였다. 수치해석 예에서는 회전-회전, 회전-고정, 고정-고정 지점을 고려하였다. 진동형은 변위의 진동형뿐만 아니라 합응력의 진동형도 산출하여 그림에 나타내었다. 휨 회전각과 전단변형에 의한 수직변위 및 전단면 회전각의 구성비율을 산정하였다.

Characteristics of Thermo-Acoustic Emission from Composite Laminates during Thermal Load Cycles

  • Kim, Young-Bok;Park, Nak-Sam
    • Journal of Mechanical Science and Technology
    • /
    • 제17권3호
    • /
    • pp.391-399
    • /
    • 2003
  • The thermo-acoustic emission (AE) technique has been applied for nondestructive characterization of composite laminates subjected to cryogenic cooling. Thermo-AE events during heating and cooling cycles showed a Kaiser effect. An analysis of the thermo-AE behavior obtained during the 1st heating period suggested a method for determining the stress-free temperature of the composite laminates. Three different thermo-AE types classified by a short-time Fourier transform of AE signals enabled to offer a nondestructive estimation of the cryogenic damages of the composites, in that the different thermo-AE types corresponded to secondary microfracturing in the matrix contacting between crack surfaces and some abrasive contact between broken fiber ends during thermal load cycles.

Infrared Scanning Near-Field Optical Microscopy (IR-SNOM) Below the Diffraction Limit

  • Sanghera, J.S.;Aggarwal, I.D.;Cricenti, A.;Generossi, R.;Luce, M.;Perfetti, P.;Margoritondo, G.;Tolk, N.;Piston, D.
    • 세라미스트
    • /
    • 제10권3호
    • /
    • pp.55-66
    • /
    • 2007
  • Infrared Scanning Near-field Optical Microscopy (IR-SNOM) is an extremely powerful analytical instrument since it combines IR spectroscopy's high chemical specificity with SNOM's high spatial resolution. In order to do this in the infrared, specialty chalcogenide glass fibers were fabricated and their ends tapered to generate SNOM probes. The fiber tips were installed in a modified near field microscope and both inorganic and biological samples illuminated with the tunable output from a free-electron laser located at Vanderbilt University. Both topographical and IR spectral images were simultaneously recorded with a resolution of ${\sim}50\;nm$ and ${\sim}100\;nm$, respectively. Unique spectroscopic features were identified in all samples, with spectral images exhibiting resolutions of up to ${\lambda}/60$, or at least 30 times better than the diffraction limited lens-based microscopes. We believe that IR-SNOM can provide a very powerful insight into some of the most important bio-medical research topics.

  • PDF

유체가 흐르는 곡선관의 진동 해석과 비선형 평형 방정식 (Vibration Analysis and Non-linear Equilibrium Equations of a Curved Pipe Conveying Fluid)

  • 정두한;정진태
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.983-986
    • /
    • 2005
  • Free vibration characteristics of a curved pipe conveying fluid is studied when the pipe is clamped at both ends. Using the perturbation method, the non-linear governing equations divided into two parts; the steady state non-linear equilibrium equations and the linearized equations of motion in the neighborhood of the equilibrium position. The natural frequencies are computed from the linearized equations of motion. In this study, the equilibrium positions are determined by two types of equations, i.e., (1) the non-linear equations, and (2) the equations obtained by neglecting the non-linear terms. The natural frequencies obtained from the non-linear equilibrium equations are compared to those obtained from the linearized equilibrium equations. From the results, as the fluid velocity increases, the equilibrium position should be determined from the nonlinear equations for the vibration analysis of the curved pipe conveying fluid.

  • PDF

Epiduroscopic Removal of a Lumbar Facet Joint Cyst

  • Jin, Hyun Seung;Bae, Jun Yeol;In, Chi Bum;Choi, Eun Joo;Lee, Pyung Bok;Nahm, Francis Sahngun
    • The Korean Journal of Pain
    • /
    • 제28권4호
    • /
    • pp.275-279
    • /
    • 2015
  • Facet joint synovial cysts are usually associated with osteoarthritis of the adjacent facet joint and/or spondylolisthesis. In between the conservative and operative ends of the treatment spectrum lie minimally invasive techniques such as cyst rupture using epiduroscopy. In this report, we describe an 82-year-old male patient presenting with low back pain radiating to his lower left extremity and associated paresthesia. Magnetic resonance imaging of the lumbar spine revealed a synovial cyst at left L4/5 facet joint. Using epiduroscopy, the cyst was mechanically ruptured by popping it with the tip of the scope. The patient remained symptom-free at his successive visits until 12 months after the procedure, and was opened for desired follow up.

Polyphase Representation of the Relationships Among Fullband, Subband, and Block Adaptive Filters

  • Tsai, Chimin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1435-1438
    • /
    • 2005
  • In hands-free telephone systems, the received speech signal is fed back to the microphone and constitutes the so-called echo. To cancel the effect of this time-varying echo path, it is necessary to device an adaptive filter between the receiving and the transmitting ends. For a typical FIR realization, the length of the fullband adaptive filter results in high computational complexity and low convergence rate. Consequently, subband adaptive filtering schemes have been proposed to improve the performance. In this work, we use deterministic approach to analyze the relationship between fullband and subband adaptive filtering structures. With block adaptive filtering structure as an intermediate stage, the analysis is divided into two parts. First, to avoid aliasing, it is found that the matrix of block adaptive filters is in the form of pseudocirculant, and the elements of this matrix are the polyphase components of the fullband adaptive filter. Second, to transmit the near-end voice signal faithfully, the analysis and the synthesis filter banks in the subband adaptive filtering structure must form a perfect reconstruction pair. Using polyphase representation, the relationship between the block and the subband adaptive filters is derived.

  • PDF

유한요소를 이용한 유연성 간극기구의 동적 해석 (Dynamic Analysis of Flexible Mechanisms with Clearances Using Finite Elements)

  • 길계환;윤용산
    • 대한기계학회논문집
    • /
    • 제14권2호
    • /
    • pp.288-297
    • /
    • 1990
  • The method of analyzing flexible mechanisms with clearances was studied considering flexibility of beams in the mechanism using finite elements. Both ends of a beam were modeled as free following Dubowsky's impact pair model. Instead some force constraints were imposed at imposed at the connections between adjoining links. Coulomb model has been developed using dry frictions in place of tangential damping forces in the impact pair model and the contact compliance and damping coefficient approximated in a form of root function were used. As examples, impacts of a rigid ball in a cylinder, impact beam model and four-bar mechanisms made up of three flexible links with clearance connections were simulated numerically. The results from examples showed similar but a little bit smaller magnitude of impact forces compared with published studies.

Timoshenko 보의 진동에 미치는 축방향관성력의 영향에 관하여 (Effects of the Longitudinal Inertia Force on Timoshenko Beam Vibration)

  • 이낙주
    • 대한기계학회논문집
    • /
    • 제2권3호
    • /
    • pp.62-68
    • /
    • 1978
  • The influences of the large amplitude free vibrations of simply supported Timoshenko beams with ends restrained to remain a fixed distance apart and with no axial restraints, which cause a longitudinal elastic force and a longitudinal inertia force, respectively, are investigated. The equations of motion derived by an appropriate linearizarion of the nonlinear strain- displacement relation have nonlinear terms arising from large curvature, longitudinal elastic force and longitudinal inertia force. The fourth order nonlinear partial differential equations for the deflection, can be reduced to the nonlinear ordinary differential equations by means of Galerkin procedure and a modal expansion. The general response and frequensy-amplitude relations are derived by the perturbation method of strained parameters. Comparison with previously published results is made.