• Title/Summary/Keyword: flux distribution

검색결과 1,171건 처리시간 0.034초

타워형 태양열발전을 위한 열유속 분포 측정기술 개발 (Development of Flux Mapping Technique for the Solar Power Tower Plant)

  • 채관교;이현진;김종규;윤환기;이상남;강용혁;서태범
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.274-279
    • /
    • 2012
  • Daegu Solar Power Tower Plant of 200 kW thermal capacity was developed for the first time in Korea, 2011. Measurement of the heat flux distribution is essential to evaluate the solar energy concentrated by reflectors and to design a suitable receiver. The flux mapping technique, which uses a radiometer and a diffuse plate, is common for measurement of the heat flux distribution. Because the solar power tower plant has a wide concentration area, the flux mapping technique using a fixed diffuse plate is difficult to apply. Therefore, the flux distribution in the solar power tower plant should be measured by the flux mapping technique using a small moving bar. In this study, we measured flux distributions with the moving-bar system developed at the KIER solar furnace and evaluated its applicability for the solar power tower plant.

  • PDF

공간고조파 해석을 이용한 brushless 전동기의 공극자속 분포 산정 (Estimation of the flux distribution in the brushless motors using space harmonic analysis)

  • 권순오;;;강규홍;홍정표
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1085-1087
    • /
    • 2004
  • The space harmonic analysis, as an analytical method, is used to estimate the flux distribution in the air gap of the brushless motors in this paper. With the flux distribution, back-emf and torque characteristics can be estimated.[1-7] Therefore, the air gap flux distribution of surface type permanent magnet motor according to the motor specifications are studied to estimate the torque characteristics in this paper. To validate the analysis result of this method, 2-dimensional finite element analysis is performed and the air gap flux density is compared to that from space harmonic analysis.

  • PDF

유한요소법에 의한 변압기의 자속분포 해석에 관한 연구 (Study on the magnetic flux distribution of transformer by the use of finite element method)

  • 임달호;현동석;이철직
    • 전기의세계
    • /
    • 제29권4호
    • /
    • pp.247-255
    • /
    • 1980
  • In this study, an application of Finite Element Method which, in principle, based on variational calculus has been presented for the two-dimensional analysis of magnetic flux distribution in the shell type core of single phase transformer. The necessary stationarity condition of energy functional and boundary conditions were determined under the assumptions that the electromagnetic field considered is stationary and that the effect of eddy current is negligible. In the process of application the domain of magnetic field was divided into triangle subsectional elements and then the matrix equations were constructed for the respective triangular element and for those of all after the manipulation of minimization process to the vector potential of magnetic field at the each vertex of the element. Furthermore the numerical computation for the equations was guided by the Gaussian Elimination Methods. As the results obtained, it is found that the aspect of magnetic flux distribution inside the core as well as the leakage flux profile at the vicinity of the inner leg of the core is not much different from the well-known distribution profile of magnetic flux, however, the procedure shows to possess the merit of the uniquely deterministic nature for the flux distribution at the desired points.

  • PDF

화재 진압용 스프링클러 헤드 유형에 따른 살수 균일도 분석 (Analysis of Water Flux Uniformity for Various Fire Sprinkler Head Type)

  • 방새미;안찬섭;김태훈
    • 한국분무공학회지
    • /
    • 제28권2호
    • /
    • pp.97-104
    • /
    • 2023
  • A sprinkler is a fire suppression system that extinguishes combustible materials in the early stages of a fire, creating a spray. However, spray formation method of the sprinkler can result in an uneven distribution of water spray on the surface of combustible materials. It is necessary to ensure a consistent water flux density regardless of the spray direction and angle. In this study, the water flux distribution was analyzed for the various types of sprinkler head: circular, flush, pendent, and upright types. All sprinkler heads have a K-factor of 80 LPM/(0.1MPa)0.5. In this study, water collection cubes were used to examine the water flux distribution. The upright type sprinkler head showed a low standard deviation in total sprayed area, indicating a high level of uniformity. The upright type head showed the lowest standard deviation in the radial direction, and also showed the lowest standard deviation in the azimuthal direction. Upright sprinkler head has no obstructing structure along the path of droplets after they are generated. For this reason, upright sprinkler head showed the most uniform water flux distribution on the floor.

전자척에서 자속밀도 해석에 관한 연구 (Analysis of Magnetic Flux Density in Electro-Magnetic Chucks)

  • 김청균
    • 한국정밀공학회지
    • /
    • 제9권2호
    • /
    • pp.29-35
    • /
    • 1992
  • The distribution of magnetic flux density of electro-magnetic chucks may clarify the clamping characteristics which are strongly related to the machining efficiency and machining accuracy in a surface grinder. Therefore the distribution of the normal and the tangential components of magnetic flux density has been analyzed theoretically. It appears that the normal and the tangential components of magnetic flux density increase as the ratio of the separator width to the pitch e/p decreases. The results seem to increase the uniformity and stability of normal component of magnetic flux density for the decreased e/p.

  • PDF

Accurate Metabolic Flux Analysis through Data Reconciliation of Isotope Balance-Based Data

  • Kim Tae-Yong;Lee Sang-Yup
    • Journal of Microbiology and Biotechnology
    • /
    • 제16권7호
    • /
    • pp.1139-1143
    • /
    • 2006
  • Various techniques and strategies have been developed for the identification of intracellular metabolic conditions, and among them, isotope balance-based flux analysis with gas chromatography/mass spectrometry (GC/ MS) has recently become popular. Even though isotope balance-based flux analysis allows a more accurate estimation of intracellular fluxes, its application has been restricted to relatively small metabolic systems because of the limited number of measurable metabolites. In this paper, a strategy for incorporating isotope balance-based flux data obtained for a small network into metabolic flux analysis was examined as a feasible alternative allowing more accurate quantification of intracellular flux distribution in a large metabolic system. To impose GC/MS based data into a large metabolic network and obtain optimum flux distribution profile, data reconciliation procedure was applied. As a result, metabolic flux values of 308 intracellular reactions could be estimated from 29 GC/ MS based fluxes with higher accuracy.

Simulated Distribution Characteristics of Surface Temperature on Irradiating of a Laser

  • Lee, Young-Wook;Yeon, Sang-Ho
    • International Journal of Contents
    • /
    • 제5권2호
    • /
    • pp.16-19
    • /
    • 2009
  • In this paper, we concern about the distribution characteristics of surface temperature by the increment of time, diffusivity and heat flux on irradiating of a laser. The penetration depth corresponding to the induced constant heat flux or irradiated laser, is simulated by a computer algorithm. The distribution of temperature versus penetration depth for the variation of time and diffusivity is characterized at the constant heat flux and on irradiating of a laser. The temperature of constant heat flux at the fixed diffusivity or time, is decreased by the pattern of exponential function as the time t or diffusivity a is increased (a=10, 100, 1000). The temperature of constant heat flux is not changed but exponentially fixed with the increasing diffusivity and the fixed time. On the other hand, the temperature of laser at the fixed diffusivity or time is decreased linearly. Our results show that the characteristics of the simulated surface temperature in a semi-infinite solid are similar to the graphs on theoretical consideration.

드론을 이용한 안면도 상공 대기경계층내의 미세먼지 연직분포 및 Flux 측정 (Vertical Aerosol Distribution and Flux Measurement in the Planetary Boundary Layer Using Drone)

  • 김희상;박용희;김우영;은희람;안강호
    • 한국입자에어로졸학회지
    • /
    • 제14권2호
    • /
    • pp.35-40
    • /
    • 2018
  • Vertical particle size distribution, total particle concentration, wind velocity, temperature and humidity measurement was performed with a drone. The drone was equipped with a wind sensor, house-made optical particle count(Hy-OPC), condensation particle counter(Hy-CPC), GPS, Temperature, Relative Humidity, Pressure and communication system. Base on the wind velocity and the particle size vertical distribution measurement with drone, the particle mass flux was calculated. The vertical particle distribution showed that the particle number concentration was very strongly correlated with the relative humidity.

노달방법의 중성자속 분포 재생 문제에의 최대 엔트로피 원리에 의한 새로운 접근 (A New Formulation of the Reconstruction Problem in Neutronics Nodal Methods Based on Maximum Entropy Principle)

  • Na, Won-Joon;Cho, Nam-Zin
    • Nuclear Engineering and Technology
    • /
    • 제21권3호
    • /
    • pp.193-204
    • /
    • 1989
  • 본 논문에서는 정보 이론의 maximum entropy Principle을 이용하여 중성자속 분포를 재생하는 새로운 방법을 시도하였다. 어떤 대상에 대한 부분적인 정보가 있을 때, 이 정보의 한도 내에서 entropy를 최대화시키는 확률 분포는 가장 객관적인 것이 된다. Nodal method계산결과인 평균 중성자속과 current의 값을 prior information으로 삼고, 핵 연료 집합체의 경계에서의 중성자속 분포를 확률의 형태로 변환해서 확률로써 다룬다. Prior information의 한도 내에서 entropy를 최대화시키는 경계에서의 확률 분포를 구하면 핵연료 집합체의 경계에서의 중성자속 분포가 구해지는데, 이것을 경계조건으로 heterogeneous assembly calculation을 행하여 세부적인 중성자속 분포를 구한다. 이 새로운 방법을 몇 개의 benchmark problem assembly에 응용해 본 결과, 노심의 안쪽 부분에서는 이 방법이 form function method에 의한 것과 비슷한 정확도를 보였고 바깥 부분에서는 다소 큰 오차를 보였다. 본 논문에서는 surface-averaged neutron current를 prior in-formation에 포함시키지 못했는데, 이것을 포함시키면 결과가 훨씬 개선 될 것으로 보인다.

  • PDF

Simulation for the effect of vertical groundwater flux on the subsurface temperature distribution

  • 신지연;이강근
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2006년도 총회 및 춘계학술발표회
    • /
    • pp.383-386
    • /
    • 2006
  • Subsurface temperature is affected by heat advection due to groundwater advection. Temperature-depth profile can be perturbed especially when there are significant vertical groundwater flux caused by external force such as injection or extraction. This research is to clarify the change of subsurface temperature distribution when the 40m x l0m sandy aquifer is stimulated by two different vertical flux($case1:\;{\pm}10^{-5}m^3/s,\;case2:\;{\pm}4{\times}10^{-5}m^3/s$) using a program called HydroGeoSphere. The resulting temperature distribution contour map shows pumping causes vertical attraction of water from deeper and warmer place which result in rising up isotherm. Additionally more injection/extraction rate, more vertical groundwater flux leads to faster Increase in temperature near the pumping well.

  • PDF