• 제목/요약/키워드: fluorescence detector

검색결과 185건 처리시간 0.028초

무질서한 매질에서 침투깊이와 파동 전파 (Penetration depth and Wave Propagation in Random Media)

  • 김기준;성기천
    • 한국응용과학기술학회지
    • /
    • 제23권1호
    • /
    • pp.70-76
    • /
    • 2006
  • The influence of fluorophor, scatterer, absorber in turbid materials by light scattering were interpreted for the scattered fluorescence intensity and wavelength, it is studied the molecular property by laser induced fluorescence spectroscopy. It can be found that the effects of optical property are penentrated in scattering media by the optical $parameters({\mu}s$, ${\mu}a$, ${\mu}t$, ${\gamma}$, ${\rho})$. The value of scattering coefficient ${\mu}s$ is large appeared by means of the increasing particles of scattering, it can be found that the slope appears exponentially as a function of distance from laser source to detector. It may also utilize in designing the best model for oil chemistry, laser medicine and application of medical engineering.

Simultaneous Quantitative Determination of Multiple Analytes with Fluorescence- Tagged Probes by Immunochromatogratphy

  • Jeong, Dong-Seok;Choi, Eui-Yul
    • Animal cells and systems
    • /
    • 제7권1호
    • /
    • pp.89-92
    • /
    • 2003
  • Immunoassays have become indispensable tools and achieved great importance in scientific and medical research. However, typical immunoassays are time-consuming and use complex, multi-step procedures. In this study, we introduce a new immunoassay system for the quantification of several analytes at a time without any washing steps. It is comprised of a detector solution with fluorescence-labeled antibodies and a test strip with immobilized capture antibodies. Using a micro-array scanner, the antigen-antibody complex was quantitatively determined by measuring the intensities of fluorescence on the capture lines or dots of nitrocellulose membrane. This method demonstrated its rapid quantitative determination of analytes without many processing steps as well as specific identification of multiple analytes in biological specimens.

입자 이동 방식에서 Laser Induced Fluorescence와 뭉침에 관한 연구 (A Study on Laser Induced Fluorescence and Coagulation in Particle Transport Mode)

  • 김기준
    • 한국응용과학기술학회지
    • /
    • 제23권4호
    • /
    • pp.340-346
    • /
    • 2006
  • The influences of fluorescence, scattering, and flocculation in turbid material by light scattering were interpreted for the scattered fluorescence intensity and wavelength, it has been studied the molecular properties by the spectroscopy of laser induced fluorescence (LIF). The effects of optical properties in scattering media have been found by the optical $parameters({\mu}_s,\;{\mu}_a,\;{\mu}_t)$. Flocculation is an important step in many solid-liquid separation processes and is widely used. When two particles approach each other, interactions of several colloid particles can come into play which may have major effect on the flocculation and LIF process, The value of scattering coefficient ${\mu}_s$ is large by means of the increasing particles of scatterer it has been found that the slope decays exponentially as a function of distance from laser source to detector. It may also aid in designing the best model for oil chemistry, biopharmaceutical products, laser medicine and application of medical engineering on LIF and coagulation in particle transport mode.

LOC 형광검출 소자를 위한 광 다이오드의 제작 및 특성 평가 (Development of Photo-diode for LOC fluorescence detector)

  • 김주환;신경식;김용국;김상식;주병권
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 디스플레이 광소자분야
    • /
    • pp.100-103
    • /
    • 2003
  • Signal detection technologies such as fluorescence, charge and electrochemical detection used in the monolithic capillary electrophoresis system to convert the biochemical reaction into the electrical signal. The fluorescence detection using photodiodes that measure fluorescence emitted from eluting molecules is widely used for the monolithic capillary electrophoresis system. In this paper, in order to fabricate a photosensor has the increased sensitivity, we investigated on the sensitivity of general type and p-i-n type diode. The p-i-n diode has higher sensitivity than photodiode. Considering these results, we fabricated p-i-n diodes on the high resistive$(4k{\Omega}{\cdot}cm)$ wafer into rectangle and finger pattern and compared internal resistance of each pattern. The internal resistance of p-i-n diode can be decreased by the application of finger pattern has parallel resistance structure from $571{\Omega}$ to $393{\Omega}$.

  • PDF

시간 상관 단일 광자 계수기의 동작 특성과 형광 수명 시간 측정에의 응용 (Operating Characteristics of a Time-Correlated Single Photon Counting System and its Application to Fluorescence Life Time Measurements)

  • 고동섭;정홍식;김웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 추계학술대회 논문집 학회본부
    • /
    • pp.512-514
    • /
    • 1989
  • A time-correlated single photon counting system combined with a mode locked $Ar^+$ laser has been utilized to measure the fluorescence decay. A side-on type photomultiplier tube has been used as a photon detector. By restricting the sensitive area and the position of the photocathode, the transit time differencies of photoelectrons in PMT has been reduced. The fluorescence life time of rhodamin 6G in ethylene glycol measured 3.9$\pm$10 ns.

  • PDF

HPLC를 이용한 carbamate계 농약의 다성분 동시분석 (A study on simultaneous determination of carbamate pesticides by HPLC)

  • 송영각;서영철;현공율;조우영;이종인
    • 한국동물위생학회지
    • /
    • 제26권2호
    • /
    • pp.145-149
    • /
    • 2003
  • To explore the most sensitive and useful method for simultaneous determination of 8 carbamate pesticides in livestock productions, the mixture of 8 carbonates was determined by HPLC with scanning fluorescence detector. For mobile phase water, acetonitrile and methanol program gradient showed more applicable sensitivity than water and acetonitrile program gradient used ExW 339 nm and EmW 445 nm for fluorescence detector. On using carbamate columns, the retention time was within 4 to 20 minutes. And this made it possible to separate and detect simultaneously. therefore we could analyze it exactly and efficiently and reduce time. The preparation process of MSPD method showed that the high recovery rate was more than 88.5% in most of the carbamate pesticides. Therefore we could say that it was an efficient and fast method analyzing out of lots of samples.

원유중 Ivermectin 구충제의 잔류실태 조사 (Examination of ivermectin residues in raw milk after skin administration)

  • 박준조;육지혜;김휴경;박혜원;김인경;이우성
    • 한국동물위생학회지
    • /
    • 제30권3호
    • /
    • pp.421-428
    • /
    • 2007
  • This study was conducted two kinds of aims: 1) to modify the analytical methods (conditions) by high performance liquid chromatography - fluorescence detector for the detection of residual ivermectin in raw milk, 2) to provide basic information for the evaluation of standard of the residual ivermectin in raw milk. It could be considerable that negative ion spectra can be better method in the LC/MS analysis for the detection of residues, Characteristic daughter ions were observed in negative ion spectra, however, linear line was not formed in positive ion one. Three Holstein cows ($500{\pm}10kg$) were applied to commercial ointment of ivermectin just one time at the first day of test, and residues in raw milk were examined for 20day after administration. The limit of detection (LOD) was 0.65ng (n=5) by HPLC/FLD, and recovery rates were $87.85%{\sim}99.47%$. The peak was observed at the 4th day, and residues lasted to the end. Thus ivermectin was prohibited when lactating.

국내산 식용식물체의 멜라토닌 함량 분석 (Analysis of Melatonin Content from Domestic Edible Plants)

  • 김석중
    • 한국식품과학회지
    • /
    • 제34권6호
    • /
    • pp.1145-1148
    • /
    • 2002
  • 뇌의 송과선에서 분비되는 호르몬인 melatonin은 생체의 산화적 손상을 방어하는 효능이 있다고 알려져 있는데, 26종의 식물체로부터 그 존재 및 함량을 분석하였다. Melatonin 함유 분획을 조제하기 위하여 동결건조된 식물체 분말을 50% ethanol로 추출한 다음 여과 후 TLC 상에서 acetone으로 전개시켜 melatonin을 분리하였다. 형광하에서 확인된 melatonin spot은 methanol로 추출한 다음 HPLC로 분석하였다. HPLC 분석시 ODS-A column을 사용하였으며 이동상은 70% ammonium acetate와 메탄올을 30 : 70(v/v)으로 섞어서 1.0 mL/min의 속도로 흘려주었다. Melatonin peak의 확인은 형광 detector를 이용하였으며 retention time은 17분이었다. 이같은 분석조건에서 셀러리, 부추, 브로콜리, 컬리플라워 등에서 높은 melatonin 함량이 확인되었다.

광화학 반응을 이용한 티오카바메이트류의 액체 크로마토그래피 검출법에 관한 연구 (A Study of Liquid Chromatographic Detection Method for Thiocarbamates by Using Photochemical Reaction)

  • 이대운;박영훈;최용욱
    • 대한화학회지
    • /
    • 제37권4호
    • /
    • pp.453-461
    • /
    • 1993
  • 테프론 코일과 저압 수은 램프를 사용, 간단하게 제작된 광화학 반응기를 이용한 HPLC 검출 방법을 연구하였다. 4종의 티오카바메이트 시료들을검출함에 있어 UV, 형광 및 전기화학 검출기 등에서 광화학 반응을 통한 액체 크로마토그래피 후컬럼 검출법의 유용성을 알아보았다. 액체 크로마토그래피를 통해 분리된 티오카바메이트류에 254nm의 UV을 조사할 경우 4종의 시료는 모두 광반응이 일어나 형광을 통해 분리된 티오카바메이트류에 254nm의 UV을 조사할 경우 4종의 시료는 모두 광반응이 일어나 형광을 나타내거나, 전기화학 검출기에 큰 검출 응답을 나타내었다. UV 검출법의 경우 광반응 생성물은 광반응전보다 검출감도는 감소하였으나 장파장쪽에서 검출이 용이하였다. 형광 검출법의 경우 광반응전 4종의 티오카바메이트는 전혀 검출되지 않았으나, 광반응 후 MPTC,CPTC는 Ph 4.0, 50% 아세토니트릴 이동상 조건에서 5.0~9.3ng의 검출한계를 나타내었다. 전기화학 검출법에서는 광반응전 시료가 매우 작은 검출 응답을 보였고, 광반응 후 시료는 5~20배 이상의 검출감도가 증대되었으며 13.3~0.02ng의 검출한계를 나타내었다. 이때 최적 검출조건은 50% 아세토니트릴 $-0.5{\times}10^{-2}$ M 인산 완충용액, pH 7.0 이었다. 또한 티오카바메이트의 광반응물과 OPA-MERC를 반응 코일내에 유도체를 형성시켜 형광검출기로 검출해냄으로써 광분해물에서 1차 아민이 생성됨을 알 수 있었다.

  • PDF

405 nm 광원을 이용한 생물입자탐지기의 에어로졸 분석성능 (The performance of Bio-aerosol Detection System (BDS) with 405 nm laser diode)

  • 정영수;정유진;이종민;최기봉
    • 한국입자에어로졸학회지
    • /
    • 제13권1호
    • /
    • pp.25-31
    • /
    • 2017
  • This paper offer the characteristics for the detection and classification of biological and non-biological aerosol particles in the air by using laser-induced-fluorescence (LIF) based Bio-aerosol Detection System (BDS). The BDS is mainly consist of an optical chamber, in-outlet nozzle system, 405 nm diode laser, an avalanche photo detector (APD) for scattering signal and photomultiplier tubes (PMT) for fluorescence signals in two different wavelength range ; F1, 510-600 nm and F2, 435-470 nm. The detection characteristics, especially ratio of fluorescence signal intensity were examined using well-known components : polystylene latex (PSL), fluorescence PSL, $2{\mu}m$ of SiO2 micro sphere, dried yeast, NADH, ovalbumin, fungicide powder and standard dust. The results indicated that the 405 nm diode laser-based LIF instrument can be a useful bio-aerosol detection system for unexpected biological threaten alter in real-time to apply for dual-use technology in military and civilian fields.