• Title/Summary/Keyword: flowing

Search Result 2,390, Processing Time 0.038 seconds

An Experimental Research on the Material Properties of Super Flowing Concrete (초유동 콘크리트의 재료특성에 관한 실험적 연구)

  • 김진근;한상훈;박연동;노재호
    • Magazine of the Korea Concrete Institute
    • /
    • v.8 no.3
    • /
    • pp.135-146
    • /
    • 1996
  • In this study, the properties of super flowing concrete containing fly ash were experimentally investigated and compared with those of ordinary concrete. Tests were carried out on five types of super flowing concrete mixes containing fly ash and three types of ordinary concrete mixes without fly ash. Flow test, 0-funnel test, box test, L type test and slump test were carried out to obtain the properties for flowability and workability of fresh concrete. The mechanical properties of hardened concrete were also investigated in terms of compressive strength, splitting tensile strength, modulus of elasticity, creep and drying shrinkage. In fresh concrete, it was found that super flowing concrete had excellent workability and flowability compared with ordinary concrete, and had self-compactable performance. Super flowing concrete *also had good mechanical properties at both early and late ages with compressive strength reaching as high as 40 MPa at 28 days. The creep deformation of super flowing concrete investigated was relatively lower than that of ordinary concrete, but drying shrinkage was much higher.

The Selection of Optimal Mixing Proportion and Cost Analysis in the SFC (초유동 콘크리트의 최적배합 선정방법 및 경제성 분석)

  • Park, Chil-Lim;Kim, Moo-Han;Kwon, Yeong-Ho;Lee, Sang-Soo;Won, Cheol
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10a
    • /
    • pp.262-268
    • /
    • 1998
  • This research is to examine the selected method of optimal mixing proportion and cost analysis in the super flowing concrete. As confined water $ratio($\beta_p$)$ and K is introduced, itis to establish optimal mixing design of super flowing concrete according to the steps of paste, mortar and concrete. From paste and mortar test, it was led to $$\beta_p$$ and $K_p$satisfying the optimum condions depending on the kinds of binders. Then $$\beta_p$$ and $K_p$ is reflected to the mix condition of super flowing concrete. The result of test, the mix condition of super flowing concrete satisfied the quality performance of concrete with adjustment of additional rate of the superplasticizer. Besides, in case of design strength $350kg/\textrm{cm}^2$ of concrete, material cost in super flowing concrete is able to be reduced 5~16% in replacement of fly ash 30% in ordinary portland cement and slag cement.

  • PDF

The Change of Pollution Loads flowing into Mokpo Harbour Due to the Operation of Mokpo Municipal Sewage Treatment Plant (목포하수처리장 가동에 따른 목포항 유입 오염부하량의 변화)

  • 김광수
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.8 no.2
    • /
    • pp.39-44
    • /
    • 2002
  • In order to study the change of pollution loads flowing into Mokpo harbour after the operation of Mokpo Municipal Sewage Treatment Plant (MMSTP) and to evaluate the contribution of MMSTP operation to the improvement of marine water quality of Mokpo harbour, the pollution loads flowing into Mokpo harbour from land in dry weather were surveyed and estimated on the bases of the seasonal flow rates and the seasonal water qualities of streams and effluents located around Mokpo harbour from summer, 1997 to spring, 1998 before the operation of MMSTP, and the pollution loads of the inflow and the effluent of MMSTP were also surveyed and estimated from winter, 1998 to spring, 1999 after the operation of MMSTP. The treatment rates of MMSTP were shown to be about 49% in COD, 76% in TSS, 79% in VSS, 3% in T-N, 7% in DIP, 29% in T-P and -32% in DIN. The change rates of pollution loads flowing into the inner harbour of Mokpo due to the operation of MMSTP were shown to be about 56% In COD, 78% in TSS, 84% in VSS, 45% in DIN, 22% in T-N, 34% in T-P and -14% in DIP. The contribution rates of MMSTP operation to the reduction of total pollution loads flowing into the entire Mokpo harbour were found to be about 3% in COD, 3% in 755,5% in VSS,1% in DIP, 3% in T-P and -1% in DIN.

  • PDF

A Study on the High-Flowing Concrete with Low Unit Weight of Cement

  • Si Woo Lee;Hong Shik Choi;Sang Chel Kim;Gweon Heo
    • The Korean Journal of Ceramics
    • /
    • v.6 no.3
    • /
    • pp.318-321
    • /
    • 2000
  • Most compressive strengths commonly used in the construction field are in a range of 240 to 300 kgf/$\textrm{cm}^2$ at 28 days. To get this rage of strengths, however, high-flowing concrete requires cementitious binders more than 400 to 450 kg/$\textrm{cm}^2$ for preventing segregation and sedimentation of aggregates. This amount of cementitious binder generates a large emission of excessive hydration heat, which may consequently induce harmful cracks in concrete structure. In order to reduce excessive hydration heat, thus, this paper aims at fabricating a high-flowing concrete under the condition that cement content is kept as low as 350kg/$\textrm{cm}^3$ by using viscose agents. In a parametric study, effects of cement types such as a ternary blended cement and Type V on he physical characteristics of high-flowing concrete were evaluated. In addition, the influence of viscosity was also investigated by applying two different viscose agents, one in a range of 6,000 to 10,000 cps and the others of 10,000 to 14,000 cps. In terms of chemical admixtures used in concrete mixture, the superplasticizer was Sulfonated Melamine-Formaldehyde Condensate with about 30,000 of molecular weight, and main component of viscose agent was HPMC (Hydroxy Propyl Methyl Cellulose). Slump flow was fixed at 50cm with different dosages of superplasticizer in weight.

  • PDF

A Study on the factors of Quality variation for High Flowing Concrete in Site (고유동 콘크리트의 품질변동 요인에 관한 연구)

  • Kwon Yeong-Ho;Lee Hyun-Ho;Lee Hwa-Jin;Ha Jae-Dam
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.743-746
    • /
    • 2004
  • This research investigates experimentally an effect on the properties of the high flowing concrete according to variations of concrete materials and site conditions. Variations of sensitivity test are selected items as followings; (1)Concrete temperature, (2)Unit water(Surface moisture of fine aggregate), (3)Fineness modulus of fine aggregate, (4)Addition ratio of high-range water reducing agent. And fresh conditions of the high flowing concrete should be satisfied with required range including slump flow$(65{\pm}5cm)$, 50cm reaching time of slump flow$(4\~10sec)$, V-box flowing time$(10\~20sec)$, U-box height(min.300mm) and air content$(4{\pm}1\%)$. As results of sensitivity test, material variations and site conditions should be satisfied with the range as followings; (1)Concrete temperature is $10\~20^{\circ}C$ (below $30^{\circ}C$), (2)Surface moisture of fine aggregate is within ${\pm}0.6\%$, (3)Fineness modulus of fine aggregate is $2.6{\pm}0.2$ and (4)addition ratio of high range water reducing agent is within $1\%$ considered flow-ability, self-compaction and segregation resistance of the high flowing concrete.

  • PDF

The Experience Study on the Floating Properties of High Flow Concrete on volum of Coarse Aggregate used Admixture (굵은골재 체적에 따른 고유동콘크리트의 유동특성에 관한 실험적 연구)

  • Choi, Sung-Woo;Kim, Ho-So;Baek, Chul-Woo;Ban, Seong-Soo;Ryu, Deuk-Hyun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.751-754
    • /
    • 2004
  • There are many factors that affect on the flowing properties of high flowing concrete(HFC), which are fluidity, compactibility, non-segregation ability and fillingability. And because the aggregate which is one of the factors occupies high volume in concrete, it has a much effect on the properties of high flowing concrete according to its size, quality and quantity etc. This is an experimental study to analyze the effect of admixture and volume of coarse aggregate in concrete on the flowing properties of high flowing concrete. For this purpose, the kinds of admixture are fly-ash and blast furnace slag. Also volume of coarse aggregate in concrete are 280, 290, 300, 310, 320 $(\ell/m^3)$. The test of flowablity properties is slump-flow, Air content, V-lot, L-Flow. According to test results, it was found that the compactibility of HFC is more superior to use blast furnace slag than other, and according .to kind of admixture, most compatible volume of coarse are different. Also when used blast furnace slag, the volume of coarse are increased than used fly-ash.

  • PDF

Flowability Evaluation of Binary and Ternary Blended of Ultra Flowing Self-Compacting Concrete (2성분계 및 3성분계 초유동 자기충전 콘크리트의 유동성 평가)

  • Choi, Yun-Wang;Jeon, Jun-Yong;Kim, Chung-Un;Jung, Jea-Guane;Jung, Woo-Young
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.485-488
    • /
    • 2006
  • This research has evaluated flowability of ultra flowing self-compacting concrete, which is limitedly used for traditional building structures, in accordance with the first class regulations of Japan Society of Civil Engineering(JSCE) that can be applied to overcrowding-arrangement of bar, as a part of application methods that ultra flowing self-compacting concrete is applied to both precast and prestress bridge structures. The experimental results show that the flowability is acceptable in ternary blended among binary and ternary blended mixings, which satifies the first class regulation of JSCE. It is also concluded to use fly ash to increase viscosity of concrete in the case of segregation resistance because of low viscosity in the mixture of slag from blast furnace and limestone micropowder. Satisfying goals of every mixing after U-box self-compacting experiment, we conclude that ultra flowing self-compacting concrete is applicable to bridges and civil constructions of overcrowding arrangement of bar with evaluation of flowability of ultra flowing self-compacting concrete.

  • PDF

Estimating the Benefits of Seawater Flowing by using Meta-Regression for Benefit Transfer - Case of Geumgang River - (메타회귀분석을 이용한 해수유통 편익추정 - 금강을 중심으로 -)

  • Shin, Chang-Seob;Cho, Wonjoo
    • Journal of Korean Society of Rural Planning
    • /
    • v.29 no.4
    • /
    • pp.191-200
    • /
    • 2023
  • This study aims to estimate the value of environmental services that could be generated by seawater flowing in the Geumgang Estuary by using meta-regression for benefit transfer. The environmental services that can be generated by seawater flowing are assumed to be improved water quality, increased biodiversity, and enhanced water-friendly effect. The analysis was conducted using 122 data from 28 studies from EVIS. The results show that households in the neighborhood where seawater is distributed are willing to pay about KRW 46,918, KRW 7,752, and KRW 7,859 per year for improved water quality, increased biodiversity, and enhanced water-friendly, respectively. The WTP of the national households other than neighboring households was found to be KRW 19,401, KRW 3,206, and KRW 3,250 for the three environmental services, respectively. The WTP for water quality improvement is higher than that for biodiversity increase and water-friendly effect increase, which may be due to the fact that water quality improvement is an environmental service that is close to the use value. In addition, neighboring households have a higher WTP than national households because neighboring households are more likely to evaluate the benefits of seawater flowing as a use value, while national households are more likely to evaluate it as a non-use value.

Characteristics of Sparkover Discharge in Flowing Air with Reynolds Number's Variable (Reynolds Number를 변수로한 유동공기의 방전특성에 관한 연구)

  • 김영훈;이동인;이광식;김상구
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1990.10a
    • /
    • pp.41-46
    • /
    • 1990
  • This paper shows the characteristics of sparkover discharge in flowing air ranging from O(Reynolds number, Re to 10.52$\times$104(Re). Also, we investigated changes of dis-charge pattern for constant input power by adjustment of the Re. The important results obtained from this paper are as followers. The maxinum sparkover voltage of flowing air are about 6.3[kV] higher than those of static air. The discharge pattern can be controlled by adjustment of the Re.

  • PDF

Application and System Establishment on Quality Control of Flowing Concrete (유동화 콘크리트의 현장적용과 품질관리 시스템 구축)

  • 김규용;길배수;한장현;주지현;박선규;한승구;조성기;김무한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.801-804
    • /
    • 1999
  • The interest in workability and quality control of concrete is increasing as to improve quality of concrete structure according to industrialization. Therefore, it is the aim of this study to evaluate the quality of flowing concrete and systematize quality control by analyzing the data of the quality control of concrete through a basic quality control system for improvement of the concrete in pumping flowing concrete for construction industy.

  • PDF