Myocardial Blood Flow Quantified by Low-Dose Dynamic CT Myocardial Perfusion Imaging Is Associated with Peak Troponin Level and Impaired Left Ventricle Function in Patients with ST-Elevated Myocardial Infarction

  • Jingwei Pan;Mingyuan Yuan;Mengmeng Yu;Yajie Gao;Chengxing Shen;Yining Wang;Bin Lu;Jiayin Zhang
    • Korean Journal of Radiology
    • /
    • v.20 no.5
    • /
    • pp.709-718
    • /
    • 2019
  • Objective: To investigate the association of myocardial blood flow (MBF) quantified by dynamic computed tomography (CT) myocardial perfusion imaging (MPI) with troponin level and left ventricle (LV) function in patients with ST-segment elevated myocardial infarction (STEMI). Materials and Methods: Thirty-five STEMI patients who successfully had undergone reperfusion treatment within 1 week of their infarction were consecutively enrolled. All patients were referred for dynamic CT-MPI. Serial high-sensitivity troponin T (hs-TnT) levels and left ventricular ejection fraction (LVEF) measured by echocardiography were recorded. Twenty-six patients with 427 segments were included for analysis. Various quantitative parameters derived from dynamic CT-MPI were analyzed to determine if there was a correlation between hs-TnT levels and LVEF on admission and again at the 6-month mark. Results: The mean radiation dose for dynamic CT-MPI was 3.2 ± 1.1 mSv. Infarcted territories had significantly lower MBF (30.5 ± 7.4 mL/min/100 mL versus 73.4 ± 8.1 mL/min/100 mL, p < 0.001) and myocardial blood volume (MBV) (2.8 ± 0.9 mL/100 mL versus 4.2 ± 1.1 mL/100 mL, p = 0.044) compared with those of reference territories. MBF showed the best correlation with the level of peak hs-TnT (r = -0.682, p < 0.001), and MBV showed a moderate correlation with the level of peak hs-TnT (r = -0.437, p = 0.026); however, the other parameters did not show any significant correlation with hs-TnT levels. As for the association with LV function, only MBF was significantly correlated with LVEF at the time of admission (r = 0.469, p = 0.016) and at 6 months (r = 0.585, p = 0.001). Conclusion: MBF quantified by dynamic CT-MPI is significantly inversely correlated with the level of peak hs-TnT. In addition, patients with lower MBF tended to have impaired LV function at the time of their admission and at 6 months.

Initial Experience with Epicardial Ultrasound Scanning in Coronary Artery Bypass Grafting

  • Kim, Dae Hyeon;Sohn, Suk Ho;Hwang, Ho Young
    • Journal of Chest Surgery
    • /
    • v.53 no.5
    • /
    • pp.263-269
    • /
    • 2020
  • Background: The benefits of epicardial ultrasound scanning (EUS) in coronary artery bypass grafting (CABG) have not yet been established. The aim of this study was to evaluate the usefulness of EUS in CABG, including in the assessment of the quality of distal anastomoses, the identification of epicardial target vessels, and the evaluation of any graft issues other than the distal anastomoses. Methods: Fifty-three patients undergoing CABG were enrolled between March 2018 and February 2019. Intraoperative EUS was performed along with transit-time flow measurement (TTFM). Graft evaluations were performed early (shortly after surgery) and 1 year after surgery for 53 (100%) and 47 (88.7%) patients, respectively. Results: EUS was applied to assess the quality of all distal anastomoses, 32 target vessels, and 2 conduit trunks. Insufficient TTFM findings were obtained for 18 grafts. However, graft revision was performed for only 3 distal anastomoses; based on the EUS findings, the remaining 15 sites were not revised. The early and 1-year overall graft patency rates were 100% (141 anastomoses) and 96.1% (122 of 127 anastomoses), respectively. All 15 of the distal anastomoses that were not revised despite insufficient TTFM results were patent at the 1-year mark. Conclusion: The routine application of EUS in CABG could be beneficial by confirming the quality of surgery and reducing unnecessary procedures.

Computational Processing of Korean Dialogue and the Construction of Its Representation Structure Based on Situational Information (상황정보에 기반한 한국어대화의 전산적 처리와 표상구조의 구축)

  • Lee, Dong-Young
    • The KIPS Transactions:PartB
    • /
    • v.9B no.6
    • /
    • pp.817-826
    • /
    • 2002
  • In Korean dialogue honorification phenomenon may occur, an honorific pronoun may be used, and a subject or an object may be completely omitted when it can be recovered based on context. This paper proposes that in order to process Korean dialogue in which such distinct linguistic phenomena occur and to construct its representation structure we mark and use the following information explicitly, not implicitly : information about dialogue participants, information about the speech act of an utterance, information about the relative order of social status for the people involved in dialogue, and information flow among utterances of dialogue. In addition, this paper presents a method of marking and using such situational information and an appropriate representation structure of Korean dialogue. In this paper we set up Korean dialogue representation structure by modifying and extending DRT (Discourse Representation Theory) and SDRT (Segmented Discourse Representation Theory). Futhermore, this paper shows how to process Korean dialogue computationally and construct its representation structure by using Prolog programming language, and then applies such representation structure to spontaneous Korean dialogue to know its validity.

Control of Size and Morphology of Particles Using CO2 Laser in a Flame (화염증 CO2 Laser를 이용한 입자의 크기 및 형상 제어)

  • Lee, Donggeun;Lee, Seonjae;Choi, Mansoo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.11
    • /
    • pp.1379-1389
    • /
    • 1999
  • A new technique for control of size and shape of flame-made particles is Introduced. The characteristic sintering time can be controlled Independently of collision time by heating the particles with irradiation of laser because the sintering time strongly depends on temperature. A coflow oxy-hydrogen diffusion flame burner was used for $SiCl_4$ conversion to silica particle. Nanometer sized aggregates irradiated by a high power CW $CO_2$ laser beam were rapidly heated up to high temperatures and then were sintered to approach volume-equivalent spheres. The sphere collides much slower than the aggregate, which results in reduction of sizes of particles maintaining spherical shape. Light scattering of Ar ion laser and TEM observation using a local sampling device were used to confirm the above effects. When the $CO_2$ laser was irradiated at low position from the burner surface, particle generation due to gas absorption of laser beam occurred and thus scattering intensity increased with $CO_2$ laser power. At high irradiation position, scattering intensity decreased with $CO_2$ laser power and TEM image showed a clear mark of evaporation and recondensation of particles for high $CO_2$ laser power. When the laser was irradiated between the above two positions where small aggregates exist, average size of spherical particles obviously decreased to 58% of those without $CO_2$ laser irradiation with the spherical shape. Even for increased carrier gas flow rate by a factor of three, TEM photograph also revealed considerable reduction of particle size.

Preparation and Evaluation of Titrated Extract of Centella Asiatica Niosome/W/O System Cream for Site Specific Targeting (니오좀을 이용한 병풀 추출물 외용제의 제조 및 평가)

  • Kim, Dong-Woo;Cho, Mi-Hyun;Park, Sun-Young;Lee, Jong-Hwa;Lee, Gye-Won;Park, Mork-Soon;Park, Jin-Kyu;Jee, Ung-Kil
    • Journal of Pharmaceutical Investigation
    • /
    • v.32 no.4
    • /
    • pp.291-297
    • /
    • 2002
  • For preventing and curing the stretching mark, TECA Niosome/W/O system creams were formulated using Titrated Extract of Centella Asiatica (TECA) which is well known for its excellent wound healing effect. The lipid-water partition coefficients and the stabilities of TECA were evaluated and TECA Niosome/W/O system (TECA N/W/O) creams were prepared with different concentrations of cetyl alcohol and ceramide. TECA N/W/O cream was evaluated with respect to their rheological properties, permeation through excised skin of hairless mouse and in vitro and in vivo accumulation in the skin of hairless mouse. In addition, dermal thicknesses of hairless mouse skins were determined following the in vivo application of TECA N/W/O cream and control cream. TECA N/W/O creams showed pseudoplastic flow and hysteresis loop. The permeation of TECA from formulations through excised skin of hairless mouse did not observed. Amount of accumulated drug in the excised skin of hairless mouse was deσeased with an increase in the concentration of cetyl alcohol and showed no relationship with concentration of ceramide. Amount of accumulated drug in formulation A-3 was higher than in niosome suspension and other formulations. In in vivo experiment, amount of accumulated drug in formulation A-2 and A-3 was much higher than that of niosome suspension. Being treated with the N/W/O cream for 8 weeks, the dermal thickness of hairless mouse skin was increased 3.2 times than that of 16 weeks-control group.

Sol-Gel Encapsulation as Matrix for Potentiometric Nitrite-Selective Membranes Doped with Chloro (5, 10, 15, 20-Tetraphenylporphyrinato) Cobalt (III)

  • Zhou, Hao;Meyerhoff, Mark E.;Bi, Kai-Shun;Park, Sung-Bae
    • Journal of the Korean Electrochemical Society
    • /
    • v.12 no.4
    • /
    • pp.335-341
    • /
    • 2009
  • Organic-inorganic hybrid sol-gel matrices were used as hosts for chloro (5, 10, 15, 20-tetraphenylporphyrinato) cobalt (III) (Co[TPP]Cl), a known ionophore for nitrite. The sol-gel precursor was prepared by the reaction of (3-isocyanopropyl) triethoxysilane with 1,4-butanediol. An appropriate amount of the anion-exchanger, tridodecylmethylammonium chloride (TDMAC) and the plasticizer, tributylphosphate (DBP) were used as membrane additives. On mixing with an acidic catalyst, the sol-state precursors slowly gelled, yielding a membrane in which the active components, Co[TPP]Cl and TDMAC, were encapsulated. The performances of the sol-gel membrane-based electrodes were compared to those of Co[TPP]Cl-based poly(vinyl chloride) (PVC) membrane electrodes. Membranes with a molar ratio of Co[TPP]Cl: TDMAC (1 : 0.1) showed reasonable response slopes toward nitrite. The response slopes were typically 53 mV/decade between $10^{-5.4}$ and $10^{-1.0}\;M$. Selectivities toward nitrite over hydrophilic and small anions such as chloride were somewhat inferior to those observed with PVC-based membranes, but selectivities over lipophilic anions were quite similar. Reduced asymmetry potentials due to protein adsorption were found to occur with the sol-gel matrix relative to PVC-based films when the sensors were employed as a detector in flow-through configuration.

A Study on a Lane Detection and Tracking Algorithm Using B-Snake (B-Snake를 이용한 차선 검출 및 추적 알고리즘에 관한 연구)

  • Kim, Deok-Rae;Moon, Ho-Sun;Kim, Yong-Deak
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.4 s.304
    • /
    • pp.21-30
    • /
    • 2005
  • In this paper, we propose lane detection and trackinB algerian using B-Snake as robust algorithm. One of chief virtues of Lane detection algorithm using B-Snake is that it is possible to specify a wider range of lane structure because B-Spline conform an arbitrary shape by control point set and that it doesn't use any camera parameter. Using a robust algorithm called CHVEP, we find the vanishing point, width of lane and mid-line of lane because of the perspective parallel line and then we can detect the both side of lane mark using B-snake. To demonstrate that this algorithm is robust against noise, shadow and illumination variations in road image, we tested this algorithm about various image divided by weather-fine, rainy and cloudy day. The percentage of correct lane detection is over 95$\%$.

Smart Lighting Control System using u-Button (u-Button을 활용한 스마트 조명 제어시스템)

  • Choi, Hyeong-Do;Jung, In-Bum
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.12
    • /
    • pp.2966-2975
    • /
    • 2013
  • Everything has been simplified and abbreviated. The stream of times can be found through the smart phones since the ubiquitous world has be mentioned by Mark Webber. Judging by the flow of times, it's easy to predict that it will be more developed in the future. There are several ways of the development and one of them is to click a button in everything. For this study, the MaKey of MIT MELIALAB shows the possibility. As applying the study of clicking a button in everything, this paper proposes the Smart Lighting Control System using the u-Button. For the actual implementation, u-Button Module with MICAz and various sensors, Actuator Node composed of ZigBeX and LED Module are produced.

Column cleaning, regeneration and storage of silica-based columns (실리카 기반 컬럼의 세척, 재생 및 보관 가이드)

  • Matt James;Mark Fever
    • FOCUS: LIFE SCIENCE
    • /
    • no.1
    • /
    • pp.1.1-1.4
    • /
    • 2024
  • This article provides comprehensive guidance on the maintenance, cleaning, regeneration, and storage of silica-based HPLC (High-Performance Liquid Chromatography) columns. The general considerations emphasize the importance of using in-line filters and guard cartridges to protect columns from blockage and irreversible sample adsorption. While these measures help, contamination by strongly adsorbed sample components can still occur over time, leading to an increase in back pressure, loss of efficiency, and other issues. To maximize column lifetime, especially with UHPLC (Ultra-High Performance Liquid Chromatography) columns, it is advisable to use ultra-pure solvents, freshly prepared aqueous mobile phases, and to filter all samples, standards, and mobile phases. Additionally, an in-line filter system and sample clean-up on dirty samples are recommended. However, in cases of irreversible compound adsorption or column voiding, regeneration may not be possible. The document also provides specific recommendations for column cleaning procedures, including the flushing procedures for various types of columns such as reversed phase, unbonded silica, bonded normal phase, anion exchange, cation exchange, and size exclusion columns for proteins. The flushing procedures involve using specific solvents in a series to clean and regenerate the columns. It is emphasized that the flow rate during flushing should not exceed the specified limit for the particular column, and the last solvent used should be compatible with the mobile phase. Furthermore, the article outlines the storage conditions for silica based HPLC columns, highlighting the impact of storage conditions on the column's lifetime. It is recommended to flush all buffers, salts, and ion-pairing reagents from the column before storage. The storage solvent should ideally match the one used in the initial column test chromatogram provided by the manufacturer, and column end plugs should be fitted to prevent solvent evaporation and drying out of the packing bed.

  • PDF

Experimental Studies on Extracorporeal Circulation by Rygg-Kyvsgaard Heart-Lung Machine, Hartman`s Solution Prime,and Moderate Hypothermia: [Part I] (Hartmann`s 용액으로 충진한 혈희석 체외순환에 관한 실험적 연구: (1보: 심폐기 Rygg-Kyvsgaard 의 혈산화와 혈압 및 혈액상에 미치는 영향))

  • 지행옥
    • Journal of Chest Surgery
    • /
    • v.4 no.2
    • /
    • pp.69-80
    • /
    • 1971
  • Total body perfusion using Rygg-Kyvsgaard Heart-Lung-Machine, Mark IV, Polystan was attempted in the dogs by the hemodilution method with total prime of buffered Hartman's solution and under hypothermia. The first of all, the functions of Rygg--Kyvsgaard Heart-Lung-Machine and the effects of the hemodilution perfusion by buffered Hartman's solution was studied. At the same time the changes of blood pressure, oxygen consumption, and influence on the blood pictures were observed before, during, and in 1-3 days after perfusion. Hemodilution rates were the average 74. 22cc/Kg(the ranges of 67 to 81 cc/Kg) and perfusion flow rates were maintained in the mean 62. 6cc/Kg/min., Although it was possible to check up to 87 cc/ Kg/min. The total body perfusion continued for 60-80 minutes. Hypothermia was employed between $36^{\circ}C$ and $32^{\circ}C$ of the rectal temperature. Arterial pressure was ranged approximately between 68mmHg and 149mmHg, but generally, it was maintained over 80mmHg. Venous pressure was measured between 6.5cm $H_2O$and 11.5cm $H_2O$. Optimum oxygenation can be expected when oxygen flow into the disposable bubble oxygenator was maintained approximately at 3.5 L/min .. Inthis way, the oxygen contents were measured in the mean value of 13.11${\pm}$O.56 vol. % of arterial blood and 8.67+1.08 vol.% of venous blood(P${\pm}$0.86 vol.% in arteriovenous oxygen difference and 2. 97${\pm}$0.62cc/Kg in oxygen consumption were calculated. According to these dates, it is as plain as pikestaff that excellent oxygenation and good tissue perfusion was accomplished. Erythrocyte, hemoglobin and hematocrit were decreased about 38% during extracorporeal circulation and these were not recovered until 1-3 days after perfusion. These decrease was resulted from relatively high degree of hemodilution rate and no blood transfusion to compensate during these experimental studies. The platelets were also decreased about 76% during perfusion, but on the contrary, it was increased progressively after perfusion and in 1-3 days after perfusion was returned to the control level. Leucocyte were also decreased during perfusion, but it was increased progessively after perfusion and in 1-3 days after perfusion exceed the control level. This increase was resulted from postoperative infection of the wound, but its analysis were not changed significantly.