• 제목/요약/키워드: floors

검색결과 864건 처리시간 0.037초

바닥충격음 차단성능 기준설정 고찰 (A Consideration on the Establishment of Standard level for Floor Impact Sound Insulation)

  • 송민정;기노갑;장길수;김흥식;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.226-229
    • /
    • 2001
  • Recently the impact sound insulation performance is regarded as one of the most import factors in determining the quality of housing environment. In order to reduce the impact sound level transmitted through the floors and structures, establishing the standard level of impact sound insulation performance is needed. In this consideration, The effecting facts for the standard insulation level is reviewed.

  • PDF

경량바닥구조의 바닥충격음 저감량 실험실 측정방법 고찰 (Review of measurement of impact sound improvement for light-weight floor)

  • Jang, Gil-Soo;Kim, Sun-Woo;Jung, Kwang-Yong
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.392.2-392
    • /
    • 2002
  • ISO 140-11 specifies a method for measuring the acoustic properties of floor coverings from the view-point of reducing impact sound transmission. This test method is limited to the specification of procedures for the Physical measurement of sound originating from an artificial impact source under laboratory conditions. In this study, ISO 140-11 was reviewed to applicable to domestic floor coverings installed on lightweight floors.

  • PDF

차동 복조 2-h 연속 위성 변조의 오류 확률 (The Error Rate Evaluation for Differential Demodulation of 2-h Continuous Phase Modulation)

  • 윤동원;한영열
    • 전자공학회논문지A
    • /
    • 제31A권7호
    • /
    • pp.29-35
    • /
    • 1994
  • The performance of continuous phase modulation signals is well known for the coherent demodulation. But the carrier recovery circuits of the coherent receiver have long acquisition time and the receiver experiences high error floors for fading channels. In this paper, we propose the differential demodulation of 2-h continuous phase modulation signals. The sets of modulation indices of 2-h phase codes adequate to the differential demodulation for differentially encoded input are obtained and the average bit error probability in Additive White Gaussian Noise environments is derived and analyzed.

  • PDF

정밀가공장비용 면진시스템의 동특성 (Dynamic Characteristics of the Vibration Isolation System for High Precision Processing Machinery)

  • 김영중;김병현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.1115-1121
    • /
    • 2003
  • The vibration isolation table system for the high precision Processing machinery has been developed. The system uses air spring as its isolation elements. An investigation of the model and the test results showed that the diaphragm has a role in the mathematical model. The vibration levels at various floors in the laboratory were investigated during operating the large shaking table for the selection of optimum installation location. The vibration test on the designed system showed good isolation performances.

  • PDF

팽창재를 사용하는 바닥 모르타르의 특성에 미치는 시공요인의 영향 (Influences of Construction Conditions on the Properties of Cement Mortars in Floors Using Expansion Agent)

  • 표대수;정성철;송명신;홍상희;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회 논문집(II)
    • /
    • pp.925-928
    • /
    • 2000
  • In this paper, physical properties of cement mortar for floor using expansion agent are discussed varied with mixing time and curing temperature, delivery time and content of added water for preventing fluidity loss. According to experimental results, slump loss shows high with elapse of time And as curing temperature goes up, it also show high when curing temperature goes up and time lag between mixing and casting increases. As curing temperature goes down, drying shrinkage shows to be decreased. But it shows decline tendency with increase of added water content.

시공중인 합성바닥슬래브의 처짐보정에 대한 수치적 연구

  • 김영찬;이정헌
    • 한국산업안전학회:학술대회논문집
    • /
    • 한국안전학회 2002년도 춘계 학술논문발표회 논문집
    • /
    • pp.293-298
    • /
    • 2002
  • In the composite deck system, beams and deck plates deflect during construction. This lens-shaped deflection may cause problems in the serviceability of a building. Therefore, it should be compensated to be level. Several methods for leveling of floor slab are available, such as increasing stiffness of structural members, pouring additional concrete. In this study, additional weight and volume o( concrete for level compensation are examined for various size of floors.

  • PDF

The Verandah: Hong Kong's Contribution to a Southeast Asian and China-coast Urban Design

  • Faure, David
    • Journal of East-Asian Urban History
    • /
    • 제3권1호
    • /
    • pp.139-160
    • /
    • 2021
  • The verandah was a common feature of Chinese multi-storeyed houses in Southeast Asia and China. This paper argues that while an earlier version of a narrow walkway might have had its origin in Singapore, the building of an extension on the upper floors encroaching the airspace over the road skirting the building was an arrangement allowed by the colonial Hong Kong government in compensation to landlords for space devoted to ventilation. As the introduction of reinforced concrete allowed buildings to become taller, the more attractive it was to developers to incorporate the verandah design.

TMD와 TLCD의 지진응답에 대한 제어성능 평가 연구 (Performance Evaluation of TMD and TLCD for Earthquake-Induced Response Control)

  • 김홍진;김형섭;민경원;오정근
    • 한국지진공학회논문집
    • /
    • 제7권5호
    • /
    • pp.85-91
    • /
    • 2003
  • 설치의 용이성과 경제성, 여러 다른 용도로의 전용 가능성, 유지보수의 용이성, 그리고 재동조의 편의성 등을 고려할 때 TLCD (Tuned Liquid Column Damper)는 기존에 건물의 응답제어에 많이 사용되는 TMD를 대체할 수 있는 감쇠장치라 할 수 있다. 본 논문에서는 TMD (Tuned Mass Damper)와 TLCD의 지진하중을 받는 구조물의 응답제어 성능평가에 관한 비교연구를 수행하였다. 성능비교분석 결과, 층간변위 제어성능에서는 TLCD가 TMD보다 우수한 성능을 보였고 가속도 제어성능에서는 서로 비슷한 것으로 나타났다. 또한 층간변위 제어에서는 저층에서 큰 제어성능을 발휘하고, 절대가속도 제어에서는 상층부에서 성능이 우수한 것으로 나타났다. 이것은 TLCD가 지진에 가장 문제가 되는 구조물의 안전성 및 거주자의 사용성에 있어서 효율적인 감쇠기라 할 수 있는 근거가 된다.

Assessment of damages on a RC building after a big fire

  • Ada, Mehmet;Sevim, Baris;Yuzer, Nabi;Ayvaz, Yusuf
    • Advances in concrete construction
    • /
    • 제6권2호
    • /
    • pp.177-197
    • /
    • 2018
  • This paper presents a case study about the damages on the structural elements of a cast in place reinforced concrete (RC) building after a big fire which was able to be controlled after six hours. The fire broke off at the $2^{nd}$ basement floor of the building, which has five basements, one ground, and two normal floors. As a result of intensely stocked ignitable materials, it spread out to the all of the upstairs. In visual inspection, most of the typical fire damages were observed (such as spalling, net-like cracks, crumbled plasters, bared or visible reinforcement). Also, failures of the $2^{nd}$ basement columns were encountered. It has been concluded that the severity failures of the columns at the $2^{nd}$ basement caused utterly deformation of the building, which is responsible for the massive damages on the beam-column connections. All of the observed damages were categorized related to the types and presented separated regarding the floors. Besides to the visual inspection, the numerical analysis was run to verify the observed damaged on the building for columns, beams, and the connection regions. It is concluded from the study that several parameters such as duration of the fire, level of the temperature influence on the damages to the RC building. Also, it is highlighted by the study that if the damaged building is considered on the overall structural system, it is not able to satisfy the minimum service requirements neither gravity loads nor earthquake conditions.

시대별 아파트 단지의 미기후 분석 (Analysis of Microclimate in Apartment Complex by Age)

  • 김철희;정응호;김대욱;차재규
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.104-108
    • /
    • 2009
  • Rapid urbanization resulted in expansion of urban area and increase of population bringing deepened housing shortage. Supply-oriented housing policy made apartment a representative residential space in Korea in spite of the short history of apartment. This study analyzed the shape and arrangement of main building by year and the microclimate in the complex depending on the number of floors. The purpose of this study was to present the basic data in developing apartment complex to solve problems like the stagnation of pollution source and the rise of temperature due to the declined ventilation in apartment complex, and the worsened urban heat island phenomenon due to the impeded flow of wind. This study rearranged the shape and arrangement of main building by year and the tendency of the number of floors by year in the process of change, by generalizing the process of change of apartment complex, a representative modern residential space through preliminary research. Based on it, 8 object lot by age was selected and simulated by using Envi-met. Simulation identified that the change of apartment complex takes place having a positive effect on microclimate in the apartment complex and the microclimate in the apartment complex is influenced a lot by the shape of complex. If in future apartment complex plan, a systematic legal criteria of design is made about the shape and arrangement of main building, it might have a positive effect on the improvement of microclimate in the apartment complex, a representative residential space in Korea.

  • PDF