• Title/Summary/Keyword: fixture

Search Result 725, Processing Time 0.023 seconds

Impedance and Read Power Sensitivity Evaluation of Flip-Chip Bonded UHF RFID Tag Chip (플립-칩 본딩된 UHF RFID 태그 칩의 임피던스 및 읽기 전력감도 산출방법)

  • Yang, Jeenmo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.4
    • /
    • pp.203-211
    • /
    • 2013
  • UHF RFID tag designers usually ndde the chip impedance and read power sensitivity value obtained when a tag chip is mounted on a chip pad. The chip impedance, however, is not able to be supplied by chip manufacturer, since the chip impedance is varied according to tag designs and fabrication processes. Instead, the chip makers mostly supply the chip impedances measured on the bare dies. This study proposes a chip impedance and read power sensitivity evaluation method which requires a few simple auxiliary and some RF measuring equipment. As it is impractical to measure the chip impedance directly at mounted chip terminals, some form test fixture is employed and the effect of the fixture is modeled and de-embeded to determine the chip impedance and the read power sensitivity. Validity and accuracy of the proposed de-embed method are examined by using commercial RFID tag chips as well as a capacitor and a resistor the value of which are known.

A New Calibration Method for the Characterization of Microwave Devices (마이크로파 소자 특성화를 위한 새로운 보정 방법)

  • 신헌철;유영길;정의붕;이종악
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.2 no.3
    • /
    • pp.10-16
    • /
    • 1991
  • The error networks due to the measuring systems and the test fixture must be previously calibrated in order to characterize the microwave devices. In this paper, it is presented a new method to characterize the error networks in which only two different microstrip lines are used for the calibration. Once each length of two calibrat- ing microstrip lines is accurately defined, the calibrated data can be easily obtained without acknowledgement for the propagation constant. The end effect is not considered when fabricated the microstrip lines used to calibration. The ATF13736 GaAs MESFET is characterized by means of the calibrating procedure with this method. The range of measuring frequency is 2 to 18 GHz, and the bias voltage and current are $V_{DS}$ =2.5V, $I_{DS}$ =20mA, respectively. Compared the calibrated data with data sheet, it is showed that the magnitude is nearly agreed with each other and the phase is deviated by 0.1 to 12 degrees in lower frequencies.

  • PDF

A short-term clinical study of marginal bone level change around microthreaded and platform-switched implants

  • Yun, Hee-Jung;Park, Jung-Chul;Yun, Jeong-Ho;Jung, Ui-Won;Kim, Chang-Sung;Choi, Seong-Ho;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.41 no.5
    • /
    • pp.211-217
    • /
    • 2011
  • Purpose: The marginal bone levels around implants following restoration are used as a reference for evaluating implant success and survival. Two design concepts that can reduce crestal bone resorption are the microthread and platform-switching concepts. The aims of this study were to analyze the placement of microthreaded and platform-switched implants and their short-term survival rate, as well as the level of bone around the implants. Methods: The subjects of this study were 27 patients (79 implants) undergoing treatment with microthreaded and platform-switched implants between October 2008 and July 2009 in the Dental Hospital of Yonsei University Department of Periodon-tology. The patients received follow-up care more than 6 months after the final setting of the prosthesis, at which time periapical radiographs were taken. The marginal bone level was measured from the reference point to the lowest observed point of contact between the marginal bone and the fixture. Comparisons were made between radiographs taken at the time of fixture installation and those taken at the follow-up visit. Results: During the study period (average of 11.8 months after fixture installation and 7.4 months after the prosthesis delivery), the short-term survival rate of microthreaded and platform-switched implants was 100% and the marginal bone loss around implants was $0.16{\pm}0.08$ mm, the latter of which is lower than the previously reported values. Conclusions: This short-term clinical study has demonstrated the successful survival rates of a microthread and platform-switched implant system, and that this system is associated with reduced marginal bone loss.

THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE EFFECT OF CORTICAL ENGAGEMENT ON IMPLANT LOAD TRANSFER IN POSTERIOR MANDIBLE (하악구치부 피질골 engagement가 임플란트 하중전달에 미치는 영향에 관한 3차원 유한요소법적 응력분석)

  • Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.5
    • /
    • pp.607-619
    • /
    • 1999
  • Cortical support is an important factor, as the engagement of the fixture in strong compact bone offers an increased load-carrying capacity and initial stability. Because of the poor bone quality in the posterior mandible and other anatomic considerations, it has been suggested that implant fixtures be placed in these locations with apical engagement of the lingual cortical plate for so-called bicortication. The purpose of this investigation was to determine the effect of cortical engagements and in addition polyoxymethylene(POM) intramobile connector(IMC) of IMZ implant on implant load transfer in edentulous posterior segment of mandible, using three-dimensional (3D) finite element analysis models composed of cortical and trabecular bone involving single implant. Variables such as (1) the crestal peri-implant defect, (2) the apical engagement of lingual cortical plate, (3) the occlusal contact position (a vertical load at central fossa or buccal cusp tip), and (4) POM IMC were investigated. Stress patterns were compared and interfacial stresses along the bone-implant interface were monitored specially. Within the scope of this study, the following observations were made. 1) Offset load and angulation of fixture led to increase the local interfacial stresses. 2) Stresses were concentrated toward the cortical bones, but the crestal peri-implant defect increased the interfacial stresses in trabecular bone. 3) For the model with bicortication, it was noticed that the crestal cortical bone provided more resistance to the bending moment and the lingual cortical plate provided more support for the vertical load. But Angulation problem of the fixture from the lingual cortical engagement caused the local interfacial stress concentrations. 4) It was not clear that POM IMC had the effect on stress distribution under the present experimental conditions, especially for the cases of crestal peri-implant defect.

  • PDF

Fracture Analysis of Implant Components using Scanning Electron Microscope - Part I : Implant Fixture (임플란트 구성요소의 파절면에 관한 주사전자현미경적 연구 - Part I: 임플란트 고정체)

  • Lim, Kwang-Gil;Kim, Dae-Gon;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.297-309
    • /
    • 2010
  • The objective of the present study was to perform a fracture analysis on fractured implant fixture after use in vivo and make clear the cause & mechanisms of failure. In case of fatigue fracture, the fractured surface represents fatigue striation. Fatigue striation indicate the progression of the crack front under cyclic loading, are characteristic of stage 2 crack growth. The site of crack initiation and stage 1 crack growth were not easily identified in any of the failure, presumably because of the complex microstructural features of the polycrystalline sample. In case of fractured by overload, dimpled or cleavage surface were observed. Using the interpretation of characteristic markings(ratchet mark, fatigue striation, dimple, cleavage et al) in fracture surfaces, failure events containing the crack origin, crack propagation, material deficiency could be understand.

SURFACE CHANGE AND FIT OF TIN-COATED ABUTMENT SCREW AFTER REPEATED CLOSING AND OPENING (TiN 코팅된 지대주 나사의 반복 착탈 후 표면 변화와 적합도에 관한 연구)

  • Kim, Jong-Nam;Chung, Chae-Heon;Kim, Hee-Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.1
    • /
    • pp.119-130
    • /
    • 2007
  • Statement of problem: A few dry lubricants were applied to abutment screws for the improvement of joint stability. Purpose: The purpose of this study was to evaluate the surface change and fit of TiN-Coated abutment screw through the examination of tested screws in the field emission scanning electron microscope(FE-SEM;Netherland, Phillips co., model:XL 30 SFEG) after repeated closing and opening. Materials and method: Titanium(3i/implant Innovations Inc, USA) and Gold-Tite abutment screws(3i/implant Innovations Inc, USA) were selected for Group A and C respectively. TiN coated titanium abutment screws were also divided into two groups, Group B and D. Abutment screws of each group and the fit of abutment screw/implant fixture/abutment were observed on FE-SEM after repeated closing and opening test respectively. Results: 1. The abutment screws of TiN coated groups(Group B and D) showed more remarkable wear resistance in the threads of the screw than those of the other group(Group A and C). 2. There were more severe wear and defect of TiN coating in Group D tightened to 32 Ncm than Group B to 20 Ncm. 3. There was no difference in the fit of abutment screw/fixture/abutment among four groups, Group A, Group B, Group C and Group D. Conclusion: Under the conditions of this study, it is suggested that TiN coating of abutment screw be clinically acceptable and be expected to reduce the risk of abutment screw loosening. TiN coating of abutment screw showed good resistance against wear and the adequate fit of abutment screw/implant fixture/abutment.

BONE RESPONSE OF THREE DIFFERENT SURFACE IMPLANTS: HISTOMORPHOMETRIC AND RESONANCE FREQUENCY ANALYSIS IN DOGS

  • Song Woo-Seok;Kim Yung-Soo;Kim Chang-Whe;Jang Kyung-Soo;Lim Young-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.6
    • /
    • pp.671-678
    • /
    • 2004
  • Statement of problem. Reducing treatment time in implant dentistry is a matter of main concern. There are so many factors affecting the success rate of immediate or early loaded implant for the initial bone response. The especially microscopic properties of implant surfaces playa major role in the osseous healing of dental implant. Purpose. The aims of this study were to perform a histologic and histomorphometric comparison of the healing characteristics anodically roughened surface, HA coated surface and RBM surface implant, and to compare of ISQ values measured by $Osstell^{TM}$ for resonance frequency analysis in dogs mandible during 2 weeks. Material and method. Bone blocks from 2 dogs were caught after covered healing for 0 day(2 h); Group I, 1 week; Group II and 2 weeks; Group III. One longitudinal section was obtained for each implant and stained with hematoxylin and eosin. Histomorphometric analysis was done with Kappa Imagebase system to calculate bone-to-implant contact and bone volumes inside the threads. ISQ values were measured in every time of surgery schedule. Conclusion. The experiment revealed that: 1. The percentages of bone-to-implant contact on the fixture in each group were not significantly different(P > 0.05). 2. The percentages of bone area inside the threads on the fixture in each group were not significantly different(P > 0.05). 3. The ISQ level showed clinical stability of each fixture during 2 weeks(all ISQ level ${\geq}71$ ).

STUDY ON RADIOGRAPHIC EVALUATION OF MARGINAL BONE LOSS AROUND OSSEOINTEGRATED IMPLANT AFTER FUNCTIONAL LOADING (기능적 부하 후 임플란트 주변의 골 흡수에 대한 방사선학적 연구)

  • Choi, Su-Jin;Chee, Young-Deok;Koh, Se-Wook
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.4
    • /
    • pp.240-247
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate marginal bone loss to the bone crest functionally loaded for up to eighteen months and also with regard to other variables of interest. Material and Methods: 135 endosseous implants(GS II, Osstem, South Korea) were placed in 35 patients. The design of GS II implant is straight with the microthread. Radiographic examinations were conducted at baseline (implant loading) and 3, 6, 9, 12 and 18 months after loading. Marginal bone level measurement was made from the reference point to the lowest observed point of contact of the marginal bone with the fixture. The reference point of the fixture was the border between the blasted surface and machined surface of the fixture. Results: Implants were on function for a mean 12.7 months(range, 3?18 months). For the 56 maxillary and 79 mandibular implants, mean marginal bone loss was 0.68 mm and 0.70 mm. Implants placed maxillary posterior area displayed more crestal bone loss than the other position. The difference between mesial and distal bone levels was statistically significant (p<0.05) with respective means of 0.51 mm and 0.62 mm. Also, The difference between bone graft group and no-bone graft group was statistically significant(p<0.05) with respective means of 0.38 mm and 0.66 mm. But no statistically significant influence of sex, type of surgery(one or two stage surgery), the implant length was observed(p>0.05). Conclusion: This study indicates the amount of marginal bone loss around implant has maintained a relative stable during follow-up periods.

FINITE ELEMENT EVALUATION OF THE EFFECT OF DIFFERENCES IN THE ABUTMENT AND THE FIXTURE DIAMETERS ON THE CERVICAL BONE STRESSES ($XiVE^{(R)}$ 임플랜트 시스템에서 고정체보다 작은 직경의 지대주 장착이 경부 피질골 응력에 미치는 효과에 대한 유한요소해석적 연구)

  • Yu Won-Jae;Lee Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.1
    • /
    • pp.95-104
    • /
    • 2005
  • Statement of problem. Higher stresses at the cervical bone around dental implants have been seen as a primary cause of the bone resorption at the site. Purpose : To determine the possibility of stress reduction by assembly of different abutment and implant in diameters. Material and methods. Abutments of several different diameters assembled on the top of XiVE$^{(R)}$ implants were axisymmetrically modeled for a series of finite element analyses. Abutments of 3.4, 3.8, 4.5, and 5.5 mm diameters were assumed to be sit on implants of the same or bigger diameters. All the abutments with an exception of 3.4mm dia, are technically possible to be assembled on bigger implants. Main consideration was given to the stresses at the cervical cortical bone induced by loads of parallel to the implant axis. Results and conclusions. 1. Higher stresses were observed at the cervical area of all the models of the same diameters of abutment and future. The peak stresses, which were shown to be a function of the fixture diameter, were from 1-1.85MPa. 2. Difference in the diameters of the abutments and the implants actually reduced the cervical bone stresses. 3. Downsizing of the abutment by one step resulted in 0.1MPa (5%) reduction of the stresses. In light of the relatively lower bone stress, however, this amount of stress reduction was decided to be biomechanically insignificant.

Vibration Test Fixture Design by Antiresonance Frequency Analysis (반공진 진동수 해석에 의한 진동시험 치구설계)

  • 김준엽;윤을재;장성조;김도영
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.33-34
    • /
    • 1997
  • 장비나 부품이 비행 또는 수송 등 실제상황에서 겪게되는 진동환경에 얼마만큼 견디는지 여부를 확인하고, 예상되는 동적 하중에 의한 성능저하나 오 동작이 일어나지 알는지 확인하기 위해 환경진동시험(environmental vibration test)이 수행된다. 이러한 환경진동시험의 경우에는 대형(대용량)의 진동시험기(shaker 또는 exciter)가 이용되며 진동시험기로부터 에너지를 시험물에 기계적으로 전달시켜줄 수 있는 진동 시험치구(이하, "치구(fixture)")가 필요하게 된다. 따라서 치구의 설계문제가 대두되며, 환경진동시험의 성공여부를 좌우하는데 대단히 중요한 역할을 하게 된다. 치구의 설계시 가장 중요한 점은 시험규격에 정해진 기준스펙트럼(specified reference spectrum)이 치구 위에 설치될 여러 시험물부착점들에 그대로 전달될 수 있는 강체치구(rigid fixture)를 설계하는 것이 가장 이상적이지만 치구의 공진 및 반공진 특성으로 인해 시험물부착점들 마다 스펙트럼이 달라지게 된다. 따라서 시험물은 과대시험(overtest) 또는/그리고 과소시험(undertest)를 겪게된다.최근의 진동시험제어 기법으로서는 다채널시스템을 이용한 여러 시험부착점들에서의 진동레벨의 평균을 제어하는 평균제어기법(average control technique)이 이용되므로서 시험주파수 범위에서 공진진동수(resonance frequency)들은 기준스펙트럼과 동일하게 제어가 가능하나 반공진 진동수(antiresonance frequency)들에서는 반공진 진동수들이 갖는 물리적 특성으로 인해 기준스펙트럼과 동일하게 제어가 이루어지지 않으므로시험규격에 정해진 정확한 진동시험이 수행되지 못하게된다.본 연구에서는 치구의 설계단계에서 치구 위의 여러 시험물 부착점들- 평균제어점(average control points)- 에서의 반공진 진동수들을 고려하여 그 감도를 게산하고, 치구의 구조변경을 수행하여 시험물 부착점들에서의 반공진 진동수를 일치시키므로서 종래의 진동시험제어시 나타나는 반공진진동수에서의 문제점을 제거할 수 있고, 그 결과 시험물 부착점들에서의 스펙트럼이 시험규격에 정해진 스펙트럼대로 진동시험이 수행될 수 있게 하는데 있다.

  • PDF