SURFACE CHANGE AND FIT OF TIN-COATED ABUTMENT SCREW AFTER REPEATED CLOSING AND OPENING  

Kim, Jong-Nam (Department of Dentistry, Graduate School of Chosun University)
Chung, Chae-Heon (Department of Dentistry, Graduate School of Chosun University)
Kim, Hee-Jung (Department of Dentistry, Graduate School of Chosun University)
Publication Information
The Journal of Korean Academy of Prosthodontics / v.45, no.1, 2007 , pp. 119-130 More about this Journal
Abstract
Statement of problem: A few dry lubricants were applied to abutment screws for the improvement of joint stability. Purpose: The purpose of this study was to evaluate the surface change and fit of TiN-Coated abutment screw through the examination of tested screws in the field emission scanning electron microscope(FE-SEM;Netherland, Phillips co., model:XL 30 SFEG) after repeated closing and opening. Materials and method: Titanium(3i/implant Innovations Inc, USA) and Gold-Tite abutment screws(3i/implant Innovations Inc, USA) were selected for Group A and C respectively. TiN coated titanium abutment screws were also divided into two groups, Group B and D. Abutment screws of each group and the fit of abutment screw/implant fixture/abutment were observed on FE-SEM after repeated closing and opening test respectively. Results: 1. The abutment screws of TiN coated groups(Group B and D) showed more remarkable wear resistance in the threads of the screw than those of the other group(Group A and C). 2. There were more severe wear and defect of TiN coating in Group D tightened to 32 Ncm than Group B to 20 Ncm. 3. There was no difference in the fit of abutment screw/fixture/abutment among four groups, Group A, Group B, Group C and Group D. Conclusion: Under the conditions of this study, it is suggested that TiN coating of abutment screw be clinically acceptable and be expected to reduce the risk of abutment screw loosening. TiN coating of abutment screw showed good resistance against wear and the adequate fit of abutment screw/implant fixture/abutment.
Keywords
Joint stability; TiN coating; Wear resistance; Fit; Screw loosening;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Binon PP, Sutter F, Beaty K, Brunski J, Gulbransen H, Weiner R. The role of screws in implant systems. Int J Oral Maxillofac Implants (supplement) 1994;9:8-63
2 Cavazos E, Bell FA. Preventing loosening of implant abutment screws. J Prosthet Dent 1996;75:566-569   DOI   ScienceOn
3 Choi JU, Jeong CM, Jeon YC, Lim JS, Jeong HC, Eom TG. Influence of Tungsten Carbide/Carbon coating on the preload of implant abutment screws. J Korean Acad Prosthodont 2006;44:229-242   과학기술학회마을
4 Scarano A, Piattelli M, Vrespa G, Petrone G, Iezzi G, Piattelli A. Bone healing around titanium and titanium nitridecoated dental implants with three surfaces: an experimental study in rats. Clin Implant Dent Relat Res 2003;5:103-111   DOI   ScienceOn
5 Scarano A, Piattelli M, Vrespa G, Caputi S, Piattelli A. Bacterial adhesion on titanium nitride-coated and uncoated implants: an in vivo human study. J Oral Implantol 2003;29:80-85   DOI   ScienceOn
6 Weiss EI, Kozak D, Gross MD Effect of repeated closures on opening torque values in seven abutment-implant systems. J Prosthet Dent 2000;84:194-9   DOI   ScienceOn
7 Byrne D, Jacobs S, O'connell B, Houston F, Claffey N. Preloads generated with repeated tightening in three types of screws used indental implant assemblies. J Prosthodont 2006;15:164-71   DOI   ScienceOn
8 Binon PP. Evaluation of matching accuracy and consistency of selected implant, standard abutments and laboratory analog. Int J Prosthodont 1995;8:162-178   PUBMED
9 Binon PP, Sutter F, Brunski J, Gulbransen H, Weiner R. The role of screws in implant systems. Int J Oral Maxillofac Implants 1994;9:48-62
10 Carr AB, Brunski JB, Hurley E. Effect of fabrication, finishing, and polishing procedures on preload in prostheses using conventional gold and plastic cylinders. Int J Oral Maxillofac Implants 1996;11:589-598   PUBMED
11 Carr AB, Brunski JB. Hurley E. The effect of finishing and polishing techniques in implant cylinder preload;9th Annual Meeting of the Academy of Osseointegration (Abstract). Int J Oral Maxilofac Implants 1995;10:123-124
12 Kim HJ, Choe HC, Kim SG, Chung CH. Effect of TiN coating of abutment screw on detorque force. Int J Oral Maxillofac Implants 2006 under review
13 Taylor. Prosthodontic problems and limitations associated with osseointegration. J Prosthet Dent 1998;79:74-78   DOI   ScienceOn
14 Bickford JH. An introduction to the design and behavior of bolted joints. 3rd ed. New York: Marcel Dekker 528-42, 1995
15 Binon PP, McHugh MJ. The effect of eliminating implant/ abutment rotational misfit on screw joint stability. Int J Prosthodont 1996;9:511-519   PUBMED
16 Goodacre CJ, Bernal G, Rungcharassaeng K, Kan JY. Clinical complications with implants and implant prostheses. J Prosthet Dent 2003;90:121-132   DOI   ScienceOn
17 Shigley JE. Mechanical Engineering Design. 3rd Edition. New York: McGraw Hill, 1987:227-52
18 Jemt T, Pettersson P. A 3-year follow-up study on single implant treatment. J Dent 1993;21:203-208   DOI   ScienceOn
19 Motosh N. Development of design charts for bolts preloaded up to the plastic range. J Eng Ind 1976;98:849-851   DOI
20 Byren D, Houston F, Cleary R. Claffey N. The fit of cast and premachined implant abutments. J Prosthet Dent 1998;80:184- 192   DOI   ScienceOn
21 Martin WC, Woody RD, Miller BM, Miller AW. Implant abutment screw rorations and preloads for four different screw materials and surfaces. J Prosthet Dent 2001;86:24-32   DOI   ScienceOn
22 Kim SK, Lee JB, Koak JY, Heo SJ, Lee KR, Cho LR, Lee SS. An abutment screw loosening study of a Diamond Like Carboncoated CP titanium implant. J Oral Rehabil 2005;32:346-50   DOI   ScienceOn
23 Binon PP. The effect of implant/abutment hexagonal misfit on screw joint stability. Int J Prosthodont 1996;9:149-152   PUBMED
24 Drago CJ. A clinical study of the efficacy of gold-tite square abutment screws in cement- retained implant restorations. Int J Oral Maxillofac Implants 2003;18:273-278
25 Binon PP. Evaluation of three slip fit hexagonal implants. Implant Dent 1996; 5:253-248
26 Mezger PR, Creugers NH. Titanium nitride coatings in clinical dentistry. J Dent 1992;20:342-344   DOI   ScienceOn
27 Koo CI, Chung CH, Choe HC. Effect of surface coating on the screw release of dental implant screw. J Korean Acad Prosthodont 2004;42:210-226
28 Haack JE, Sakaguchi RL, Sun T, Coffey JP. Elongation and preload stress in dental implant abutment screws. Int J Oral Maxillofacimplants 1995;10:529-536
29 Binon PP. Implants and components: Entering the new millennium. Int J Oral Maxillofac Implants 2000;5:76-94
30 Milic M, Milosavljevic M, Bibic N, Nenadovic T. Mechanical Properties of TiN coatings. Thin Solid Films 1985;126:319- 323   DOI   ScienceOn
31 Abokowitz S, Burke JJ, Hiltz RH. Titanium in industry. New York(NY): Van Nostrand Co Inc; 1955