DOI QR코드

DOI QR Code

A short-term clinical study of marginal bone level change around microthreaded and platform-switched implants

  • Yun, Hee-Jung (Department of Periodontology, Yonsei University College of Dentistry) ;
  • Park, Jung-Chul (Department of Periodontology, Yonsei University College of Dentistry) ;
  • Yun, Jeong-Ho (Department of Periodontology, Yonsei University College of Dentistry) ;
  • Jung, Ui-Won (Department of Periodontology, Yonsei University College of Dentistry) ;
  • Kim, Chang-Sung (Department of Periodontology, Yonsei University College of Dentistry) ;
  • Choi, Seong-Ho (Department of Periodontology, Yonsei University College of Dentistry) ;
  • Cho, Kyoo-Sung (Department of Periodontology, Yonsei University College of Dentistry)
  • Received : 2011.06.13
  • Accepted : 2011.08.24
  • Published : 2011.10.31

Abstract

Purpose: The marginal bone levels around implants following restoration are used as a reference for evaluating implant success and survival. Two design concepts that can reduce crestal bone resorption are the microthread and platform-switching concepts. The aims of this study were to analyze the placement of microthreaded and platform-switched implants and their short-term survival rate, as well as the level of bone around the implants. Methods: The subjects of this study were 27 patients (79 implants) undergoing treatment with microthreaded and platform-switched implants between October 2008 and July 2009 in the Dental Hospital of Yonsei University Department of Periodon-tology. The patients received follow-up care more than 6 months after the final setting of the prosthesis, at which time periapical radiographs were taken. The marginal bone level was measured from the reference point to the lowest observed point of contact between the marginal bone and the fixture. Comparisons were made between radiographs taken at the time of fixture installation and those taken at the follow-up visit. Results: During the study period (average of 11.8 months after fixture installation and 7.4 months after the prosthesis delivery), the short-term survival rate of microthreaded and platform-switched implants was 100% and the marginal bone loss around implants was $0.16{\pm}0.08$ mm, the latter of which is lower than the previously reported values. Conclusions: This short-term clinical study has demonstrated the successful survival rates of a microthread and platform-switched implant system, and that this system is associated with reduced marginal bone loss.

Keywords

References

  1. Branemark PI, Adell R, Breine U, Hansson BO, Lindström J, Ohlsson A. Intra-osseous anchorage of dental prostheses. I. Experimental studies. Scand J Plast Reconstr Surg 1969;3:81-100. https://doi.org/10.3109/02844316909036699
  2. Atwood DA. Some clinical factors related to rate of resorption of residual ridges. 1962. J Prosthet Dent 2001;86:119-25.
  3. Lekholom U, Zarb GA. Patient selection and preparation. In: Branemark PI, Zarb GA, Albrektsson T, editors. Tissue-integrated prostheses: osseointegration in clinical dentistry. Chicago: Quintessence; 1985. p.199-220.
  4. Ahlqvist J, Borg K, Gunne J, Nilson H, Olsson M, Astrand P. Osseointegrated implants in edentulous jaws: a 2-year longitudinal study. Int J Oral Maxillofac Implants 1990;5:155-63.
  5. Albrektsson T, Zarb G, Worthington P, Eriksson AR. The long-term efficacy of currently used dental implants: a review and proposed criteria of success. Int J Oral Maxillofac Implants 1986;1:11-25.
  6. Berglundh T, Persson L, Klinge B. A systematic review of the incidence of biological and technical complications in implant dentistry reported in prospective longitudinal studies of at least 5 years. J Clin Periodontol 2002;29 Suppl3:197-212. https://doi.org/10.1034/j.1600-051X.29.s3.12.x
  7. Chang M, Wennstrom JL, Odman P, Andersson B. Implant supported single-tooth replacements compared to contralateral natural teeth. Crown and soft tissue dimensions. Clin Oral Implants Res 1999;10:185-94. https://doi.org/10.1034/j.1600-0501.1999.100301.x
  8. Lazzara RJ, Porter SS. Platform switching: a new concept in implant dentistry for controlling postrestorative crestal bone levels. Int J Periodontics Restorative Dent 2006;26:9-17.
  9. Schrotenboer J, Tsao YP, Kinariwala V, Wang HL. Effect of microthreads and platform switching on crestal bone stress levels: a finite element analysis. J Periodontol 2008;79:2166-72. https://doi.org/10.1902/jop.2008.080178
  10. Friberg B, Grondahl K, Lekholm U. A new self-tapping Brånemark implant: clinical and radiographic evaluation. Int J Oral Maxillofac Implants 1992;7:80-5.
  11. Gonshor A, Goveia G, Sotirakis E. A prospective, multicenter, 4-year study of the ACE Surgical resorbable blast media implant. J Oral Implantol 2003;29:174-80. https://doi.org/10.1563/1548-1336(2003)029<0174:APMSOT>2.3.CO;2
  12. Buser D, Weber HP, Lang NP. Tissue integration of non-submerged implants. 1-year results of a prospective study with 100 ITI hollow-cylinder and hollow-screw implants. Clin Oral Implants Res 1990;1:33-40. https://doi.org/10.1034/j.1600-0501.1990.010105.x
  13. Bragger U, Hafeli U, Huber B, Hammerle CH, Lang NP. Evaluation of postsurgical crestal bone levels adjacent to non-submerged dental implants. Clin Oral Implants Res 1998;9:218-24. https://doi.org/10.1034/j.1600-0501.1998.090402.x
  14. Esposito M, Grusovin MG, Coulthard P, Thomsen P, Worthington HV. A 5-year follow-up comparative analysis of the efficacy of various osseointegrated dental implant systems: a systematic review of randomized controlled clinical trials. Int J Oral Maxillofac Implants 2005;20:557-68.
  15. Adell R, Lekholm U, Rockler B, Brånemark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981;10:387-416. https://doi.org/10.1016/S0300-9785(81)80077-4
  16. Guo E. Mechanical properities of cortical bone and cancellous bone tissue. 2nd ed. Boca Raton: CRC Press; 2001. p.1-23.
  17. Lee DW, Choi YS, Park KH, Kim CS, Moon IS. Effect of microthread on the maintenance of marginal bone level: a 3-year prospective study. Clin Oral Implants Res 2007;18:465-70. https://doi.org/10.1111/j.1600-0501.2007.01302.x
  18. Oh TJ, Yoon J, Misch CE, Wang HL. The causes of early implant bone loss: myth or science? J Periodontol 2002;73:322-33. https://doi.org/10.1902/jop.2002.73.3.322
  19. Jung YC, Han CH, Lee KW. A 1-year radiographic evaluation of marginal bone around dental implants. Int J Oral Maxillofac Implants 1996;11:811-8.
  20. Hansson S. The implant neck: smooth or provided with retention elements. A biomechanical approach. Clin Oral Implants Res 1999;10:394-405. https://doi.org/10.1034/j.1600-0501.1999.100506.x
  21. Abrahamsson I, Berglundh T. Tissue characteristics at microthreaded implants: an experimental study in dogs. Clin Implant Dent Relat Res 2006;8:107-13. https://doi.org/10.1111/j.1708-8208.2006.00016.x
  22. Quirynen M, Bollen CM, Eyssen H, van Steenberghe D. Microbial penetration along the implant components of the Branemark system. An in vitro study. Clin Oral Implants Res 1994;5:239-44. https://doi.org/10.1034/j.1600-0501.1994.050407.x
  23. Ericsson I, Persson LG, Berglundh T, Marinello CP, Lindhe J, Klinge B. Different types of inflammatory reactions in peri-implant soft tissues. J Clin Periodontol 1995;22:255-61.
  24. Waerhaug J. Subgingival plaque and loss of attachment in periodontosis as evaluated on extracted teeth. J Periodontol 1977;48:125-30. https://doi.org/10.1902/jop.1977.48.3.125
  25. Hürzeler M, Fickl S, Zuhr O, Wachtel HC. Peri-implant bone level around implants with platform-switched abutments: preliminary data from a prospective study. J Oral Maxillofac Surg 2007;65(7 Suppl 1):33-9.
  26. Lopez-Marí L, Calvo-Guirado JL, Martin-Castellote B, Gomez-Moreno G, Lopez-Mari M. Implant platform switching concept: an updated review. Med Oral Patol Oral Cir Bucal 2009;14:e450-4.
  27. Kwon HJ, Lee DW, Park KH, Kim CK, Moon IS. Influence of the tooth- and implant-side marginal bone level on the interproximal papilla dimension in a single implant with a microthread, conical seal, and platform-switched design. J Periodontol 2009;80:1541-7. https://doi.org/10.1902/jop.2009.080558
  28. Calandriello R, Tomatis M, Vallone R, Rangert B, Gottlow J. Immediate occlusal loading of single lower molars using Brånemark System Wide-Platform TiUnite implants: an interim report of a prospective open-ended clinical multicenter study. Clin Implant Dent Relat Res 2003;5 Suppl 1:74-80. https://doi.org/10.1111/j.1708-8208.2003.tb00018.x
  29. Glauser R, Lundgren AK, Gottlow J, Sennerby L, Portmann M, Ruhstaller P, et al. Immediate occlusal loading of Brånemark TiUnite implants placed predominantly in soft bone: 1-year results of a prospective clinical study. Clin Implant Dent Relat Res 2003;5 Suppl 1:47-56.
  30. Vanden Bogaerde L, Pedretti G, Dellacasa P, Mozzati M, Rangert B, Wendelhag I. Early function of splinted implants in maxillas and posterior mandibles, using Brånemark System Tiunite implants: an 18-month prospective clinical multicenter study. Clin Implant Dent Relat Res 2004;6:121-9. https://doi.org/10.1111/j.1708-8208.2004.tb00219.x
  31. Wennström JL, Ekestubbe A, Gröndahl K, Karlsson S, Lindhe J. Implant-supported single-tooth restorations: a 5-year prospective study. J Clin Periodontol 2005;32:567-74. https://doi.org/10.1111/j.1600-051X.2005.00715.x
  32. Adell R, Lekholm U, Rockler B, Brånemark PI, Lindhe J, Eriksson B, et al. Marginal tissue reactions at osseointegrated titanium fixtures (I). A 3-year longitudinal prospective study. Int J Oral Maxillofac Surg 1986;15:39-52. https://doi.org/10.1016/S0300-9785(86)80010-2
  33. Siegele D, Soltesz U. Numerical investigations of the influence of implant shape on stress distribution in the jaw bone. Int J Oral Maxillofac Implants 1989;4:333-40.
  34. Hollender L, Rockler B. Radiographic evaluation of osseointegrated implants of the jaws. Experimental study of the influence of radiographic techniques on the measurement of the relation between the implant and bone. Dentomaxillofac Radiol 1980;9:91-5. https://doi.org/10.1259/dmfr.1980.0019

Cited by

  1. 임플란트의 collar design이 변연골과 연조직에 미치는 영향 vol.50, pp.1, 2011, https://doi.org/10.4047/jkap.2012.50.1.21
  2. Long‐term retrospective study of narrow implants for fixed dental prostheses vol.24, pp.8, 2011, https://doi.org/10.1111/j.1600-0501.2012.02472.x
  3. Peri-implant Crestal Bone Preservation: Where do We Stand? vol.4, pp.2, 2011, https://doi.org/10.5005/jp-journals-10012-1096
  4. A Minimally Invasive Sinus Augmentation Technique using a Novel Bone Graft Delivery System vol.4, pp.2, 2013, https://doi.org/10.5005/jp-journals-10012-1097
  5. Lateral Sinus Augmentation: A Simplified Safer Approach vol.4, pp.2, 2011, https://doi.org/10.5005/jp-journals-10012-1098
  6. Implant and Tooth Supported Full-Mouth Rehabilitation with Hobo Twin-Stage Technique vol.4, pp.2, 2011, https://doi.org/10.5005/jp-journals-10012-1099
  7. Tooth Implant Connection vol.4, pp.3, 2011, https://doi.org/10.5005/jp-journals-10012-1100
  8. Implant Supported Mandible Over Denture with Four Implants Key Facts vol.4, pp.3, 2011, https://doi.org/10.5005/jp-journals-10012-1101
  9. Sinus Augmentation Utilizing Calcium Phosphosilicate Biomaterial Followed by Delayed Implant Rehabilitation: Radiological and Clinical Analyses vol.4, pp.3, 2013, https://doi.org/10.5005/jp-journals-10012-1102
  10. Edlan-Mejchar Vestibular Deeping in a Failing Implant Case vol.4, pp.3, 2011, https://doi.org/10.5005/jp-journals-10012-1103
  11. Full Mouth Rehabilitation of a Patient having Limited Interarch Space with Mandibular Implant Retained Fixed Adoro Fused to Metal Fp-1 Prosthesis and Maxillary Acrylic Removable Conventional Complete vol.4, pp.3, 2013, https://doi.org/10.5005/jp-journals-10012-1104
  12. Guided Bone Ridge Augmentation: A Clinicohistologic and Radiographic 2 Years Follow-up vol.4, pp.3, 2011, https://doi.org/10.5005/jp-journals-10012-1105
  13. Lateral Sinus Augmentation: A Safer Technique vol.4, pp.3, 2013, https://doi.org/10.5005/jp-journals-10012-1106
  14. Influence of transmucosal designs of dental implant on tissue regeneration in beagle dogs vol.10, pp.1, 2013, https://doi.org/10.1007/s13770-013-0373-9
  15. Comparison of Micromotion around Basally Osseointegrated and Crestal Osseointegrated Implant in Mandibular First Molar Region: A Finite Element Analysis Study vol.5, pp.2, 2011, https://doi.org/10.5005/jp-journals-10012-1113
  16. Implant-abutment Selection: A Literature Review vol.5, pp.2, 2011, https://doi.org/10.5005/jp-journals-10012-1114
  17. The effect of platform switching on stress distribution in implants and periimplant bone studied by nonlinear finite element analysis vol.112, pp.5, 2011, https://doi.org/10.1016/j.prosdent.2014.04.017
  18. The influence of thread geometry on implant osseointegration under immediate loading: a literature review vol.6, pp.6, 2014, https://doi.org/10.4047/jap.2014.6.6.547
  19. Early loading of splinted implants in the posterior mandible: a prospective multicentre case series vol.43, pp.3, 2011, https://doi.org/10.1111/jcpe.12513
  20. An In Vivo 24‐Month Study to Compare Crestal Bone Loss and Pocket Depth of Platform‐Switched Implants Placed in Maxillary Anterior and Mandibular Posterior Regions vol.25, pp.5, 2011, https://doi.org/10.1111/jopr.12320
  21. Novel expandable short dental implants in situations with reduced vertical bone height—technical note and first results vol.3, pp.None, 2011, https://doi.org/10.1186/s40729-017-0107-1
  22. Microthreaded Implants and Crestal Bone Loss: A Systematic Review vol.43, pp.2, 2011, https://doi.org/10.1563/aaid-joi-d-16-00170
  23. Clinical Performance of Short Expandable Dental Implants for Oral Rehabilitation in Highly Atrophic Alveolar Bone: 3-year Results of a Prospective Single-Center Cohort Study vol.56, pp.7, 2011, https://doi.org/10.3390/medicina56070333