• 제목/요약/키워드: fire safety guidelines

검색결과 71건 처리시간 0.022초

A Study on Proposals for Improving the Fire Protection Regulations for Nuclear Power Plants (원자력발전소 화재방호 규제 개선 방향에 관한 연구)

  • Ma, Jin-Soo;Kwon, Kyung-Ok
    • Fire Science and Engineering
    • /
    • 제24권4호
    • /
    • pp.116-122
    • /
    • 2010
  • The fire protection system of nuclear power plants shall be designed, constructed and operated, through a defense-in depth criterion to suppress the leakage of radioactivity to the outside and to allow the safety shutdown function when a fire occurs. In order to achieve these purposes, most of countries abroad operating the nuclear power plants keep up the integrated regulations, however we have two guidelines, the fire protection service act and the nuclear energy act, as mandatory requirements to apply to the fire protection systems in nuclear power plants. It has shown that USA, Canada and Japan which have long experience in operating nuclear power plants have regulations integrated technically for fire protection system of nuclear power plants. It is proposed that the things once verified the risk analysis of the fire hazard by the nuclear law in the design for fire suppression system in plants should be authorized by the fire protection service act as an exception.

Numerical Study of Fire Behavior Induced by Gas Leakage in Combined Cycle Power Plant (복합발전플랜트 내의 가스 화재 거동에 관한 수치해석)

  • Park, Jaeyong;Sung, Kunhyuk;Li, Longnan;Choi, Jinwook;Kim, Daejoong;Lee, Seong Hyuk;Ryou, Hong Sun
    • Journal of ILASS-Korea
    • /
    • 제20권2호
    • /
    • pp.107-113
    • /
    • 2015
  • To date, the demand for Combined Cycle Power Plant (CCPP) has been continuously increased to overcome the problem of air pollution and lack of energy. In particular, the underground CCPP is exposed to substantial fire and explosion risks induced by gas leakage. The present study conducted numerical simulations to examine the fire behavior and gas leakage characteristics for a restricted region including gas turbine and other components used in a typical CCPP system. The commercial code of FLUENT V.14 was used for simulation. From the results, it was found that flammable limit distribution of leakage gas affects fire behavior. Especially, the flame is propagated in an instant in restricted region with LNG gas. In addition, consequence analysis factors such as critical temperature and radiation heat flux are introduced. These results would be useful in making the safety guidelines for the underground CCPP.

A Study on the Response Technique for Toxic Chemicals Release Accidents - Hydrogen Fluoride and Ammonia - (독성 화학물질 누출사고 대응 기술연구 - 불산 및 암모니아 누출을 중심으로 -)

  • Yoon, Young Sam;Cho, Mun Sik;Kim, Ki Joon;Park, Yeon Shin;Hwang, Dong Gun;Yoon, Jun heon;Choi, Kyung Hee
    • Korean Journal of Hazardous Materials
    • /
    • 제2권1호
    • /
    • pp.31-37
    • /
    • 2014
  • Since the unprecedented hydrogen fluoride leak accident in 2012, there has been growing demand for customized technical information for rapid response and chemical accident management agencies including the Ministry of Environment, the National Emergency Management Agency, and the National Police Agency need more information on chemicals and accident management. In this regard, this study aims to provide reliable technical data and guidelines to initial response agencies, similar to accident management technical reports of the US and Canada. In this study, we conducted a questionnaire survey and interviews on initial response agencies like fire stations, police stations, and local governments to identify new information items for appropriate initial response and improvements of current guidelines. We also collected and reviewed the Canada's TIPS, US EPA's hydrogen fluoride documents, domestic and foreign literature on applicability tests of control chemicals, and interview data, and then produced items to be listed in the technical guidelines. In addition, to establish database of on-site technical information, we carried out applicability tests for accident control data including ① emergency shut down devide, safety guard, shut down valve, ground connection, dyke, transfer pipe, scrubber, and sensor; ② literature and field survey on distribution type and transportation/storage characteristics (container identification, valve, ground connection, etc.); ③ classification and identification of storage/transportation facilities and emergency management methodslike leak prevention, chemicals control, and cutoff or bypass of rain drainage; ④ domestic/foreign analysis methods and environmental standards including portable detection methods, test standards, and exposure limits; and ⑤ comparison/evaluation of neutralization efficiency of control chemicals on toxic substances.

Analytical Study on the Fire Resistance of iTECH Composite Beam (iTECH 합성보의 내화성능에 대한 해석연구)

  • Lim, Yoon Hee;Kang, Seong Deok;Oh, Myoung Ho;Kim, Myeong Han;Kim, Sang Dae
    • Journal of Korean Society of Steel Construction
    • /
    • 제18권5호
    • /
    • pp.655-664
    • /
    • 2006
  • The purpose of thisanalytical study of an iTECH composite beam subjected to fire conditions is to determine the beam's fire resistance performance using its load ratio and fire protection as parameters. A composite structural system is expected to have a safer and more economical fire safety design than a mere collection of isolated members.heat transfer analysis was performed on the basis of the finite element program ANSYS 10.0 using an ISO834 standard fire, following the main guidelines proposed by EC1 Part 2.2 and EC4 Part 1.2. To validate the analytical simulation of the iTECH composite beam, comparison of the experimental tests was proposed.

A Study on the Fire Drill Behavior Characteristics in Rehabilitation Center for Visually Impaired Persons (시각장애인 복지관의 화재 피난행태 특성분석 연구)

  • Lee, Jeong-Soo;Kwon, Heung-Soon;Kim, Eung Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제16권8호
    • /
    • pp.5646-5653
    • /
    • 2015
  • This study focused on the architectural, interior and management guidelines in rehabilitation center for visually impaired persons. For these purposes, we reviewed the movement behaviors and the characteristics of fire drill in rehabilitation center for visually impaired persons. The results are as follows. : First, the liner circulation paths and interior landmarks are recommended, and dwelling units and program rooms should be located in ground floor for barrier free evacuation. Second, It is important to establish continuous handrail, variations of paving patterns and materials, good color definition, tactile informations and directional sound. Third, it is necessary to serve more specified architectural, interior, and management guidelines according to impaired prototypes.

Fire resistance assessment of precast fireproof duct slab (프리캐스트 방식 내화풍도슬래브의 화재저항성 평가)

  • Choi, Soon-Wook;Kang, Tae-Ho;Lee, Chulho;Kim, Se Kwon;Kim, Tae Kyun;Chang, Soo-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • 제22권6호
    • /
    • pp.669-680
    • /
    • 2020
  • In Korea, fireproof performance is evaluated through a series of fire-resistance tests for important structures, and the performance standard follows the guidelines suggested by ITA. The fireproof duct slab manufactured by combining the slab and the fireproof material with a precast method is effective in that it can eliminate the construction time of the fireproof material. In this study, a series of fire resistance tests was performed on the fire test specimens under the RWS fire scenario in order to secure the fire resistance performance of the precast fireproof duct slab. As a result of the test, it was found that the fireproof performance was secured when the thickness of the fireproof material was 30 mm or more. In both fireproof materials and concrete, the rate of temperature change initially increased, then decreased, and then increased again, and the temperature at the inflection point was measured as 110℃ for all fireproof materials and concrete. It is judged that this occurs when the C-S-H (CaO-SiO2-H2O) generated by the hydration reaction in both the fireproof material and concrete is dehydrated.

A Study of a Dike Design Considering a Leakage Velocity at an Opening Hole in Case of a Leakage Accident (누출사고 시 저장탱크 위험물 누출속도를 고려한 방유제 설계에 관한 연구)

  • Lee, Jae Yeol;Kim, Dong Hyun;Ban, Soon Hee;Lee, Chang Jun
    • Journal of the Korean Society of Safety
    • /
    • 제32권6호
    • /
    • pp.40-45
    • /
    • 2017
  • Chemical accidents generated during maintenance, repair, and normal operation, such as dispersion, fire, and explosions, can cause massive losses like a 2012 hydro fluorine leak in Gumi, South Korea. Since this accident, many researches have studied physical mitigation systems. However, due to many difficulties including potential costs and lack time, it is really hard for many companies to install mitigation systems without prior knowledge. Thus, the efficacy of mitigation system should be evaluated. This study assesses a dike design considering the fluid velocity at an open hole when a leakage accident occurs. It is assumed that leakage materials follow a free fall motion. Throughout case studies, a current KOSHA guide for a dike design was evaluated and new guidelines handling various conditions were proposed.

A Study of the Distance between a Tank and a Dike Considering a Leakage Velocity at an Opening Hole in case of a Leakage Accident (누출사고 시 저장탱크 위험물 누출속도를 고려한 탱크와 방유제 사이 간격에 관한 연구)

  • Lee, Jae Yeol;Kim, Dong Hyun;Ban, Soon Hee;Lee, Chang Jun
    • Journal of the Korean Society of Safety
    • /
    • 제33권5호
    • /
    • pp.35-41
    • /
    • 2018
  • Chemical accidents generated during maintenance, repair, and normal operation, such as dispersion, fire, and explosions, can cause massive losses like a 2012 hydro fluorine leak in Gumi, South Korea. Since this accident, many researches have studied physical mitigation systems. However, due to the lack of potential costs and time, it is really hard for many companies to install mitigation systems without prior knowledge. Thus, the efficacy of mitigation system should be evaluated. This study assesses a dike design considering the fluid velocity at an open hole when a leakage accident occurs. It is assumed that leakage materials follow a free fall motion. Throughout case studies, a current KOSHA guide for a dike design was evaluated and new guidelines handling various conditions were proposed.

Effect of tunnel fire: Analysis and remedial measures

  • Choubey, Bishwajeet;Dutta, Sekhar C.;Kumar, Virendra
    • Structural Engineering and Mechanics
    • /
    • 제80권6호
    • /
    • pp.701-709
    • /
    • 2021
  • The paper aims at improving the understanding and mitigating the effects of tunnel fires that may breakout due to the burning fuel and/or explosion within the tunnel. This study particularly focuses on the behavior of the commonly used horse shoe geometry of tunnel systems. The problem has been obtained using an adequate well-established program incorporating the Lagrangian approach. A transient-thermo-coupled static structural analysis is carried out. The effects of radiation and convection to the outer walls of the tunnel is studied. The paper also presents the impact of the hazard on the structural integrity of the tunnel. A methodology is proposed to study the tunnel fire using a model which uses equivalent steel sheet to represent the presence of reinforcements to improve the computational efficiency with adequate validation. A parametric study has been carried out and the effect of suitable lining property for mitigating the fire hazard is arrived at. Detailed analysis is done for the threshold limits of the properties of the lining material to check if it is acceptable in all aspects for the integrity of the tunnel. The study may prove useful for developing insights for ensuring tunnel fire safety. To conduct such studies experimentally are tremendously costly but are required to gain confidence. But, scaled models, as well as loading and testing conditions, cannot be studied by many trials experimentally as the cost will shoot up sharply. In this context, the results obtained from such computational studies with a feasible variation of various combinations of parameters may act as a set of guidelines to freeze the adequate combination of various parameters to conduct one or two costly experiments for confidence building.

A Study on the Evacuation Time of the Subway Station (지하역사 승강장 피난시간 분석 연구)

  • Shin, Min-Jung;Kim, Jin-Ho;Kim, Dan-Hee
    • Proceedings of the KSR Conference
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.214-220
    • /
    • 2011
  • As the number of subway user increases, not only interests in safety increase but also interests in evacuation for a conflagration expand after 'Daegu Subway Fire Disaster' took place. It is necessary to revise the standard of evacuation time and guidelines to guarantee safety of station and platform considering changes in subway environments caused by construction of the deeply underground subway station. Hence this study investigates the current status of the evacuation time of respective station through a site investigation and the results of this study may be utilized as a basic material to calculate an appropriate evacuation time.

  • PDF