Fire resistance assessment of precast fireproof duct slab
![]() |
Choi, Soon-Wook
(Underground Space Safety Research Center, Korea Institute of Civil Engineering and Building Technology)
Kang, Tae-Ho (Underground Space Safety Research Center, Korea Institute of Civil Engineering and Building Technology) Lee, Chulho (Underground Space Safety Research Center, Korea Institute of Civil Engineering and Building Technology) Kim, Se Kwon (Research Institute, HONG G) Kim, Tae Kyun (HONG G) Chang, Soo-Ho (Construction Industry Promotion Department, Korea Institute of Civil Engineering and Building Technology) |
1 | Chang, S.H., Choi, S.W., Kwon, J.W., Kim, S.H., Bae, G.J. (2007), "Alteration of mechanical properties of tunnel structural members after a tunnel fire accident", Journal of Korean Tunnelling and Underground Space Association, Vol. 9, No. 2, pp. 157-169. |
2 | Choi, S.W., Chang, S.H., Kim, H.Y., Jo, B.H. (2010), "Assessment of structural fire resistance of a fire-proofed immersed tunnel under tunnel fire scenarios", Journal of Korean Tunnelling and Underground Space Association, Vol. 12, No. 6, pp. 429-441. |
3 | Choi, S.W., Lee, G.P., Chang, S.H., Park, Y.T., Bae, G.J. (2014), "Fire resistance assessment of high strength segment concrete depending on PET fiber amount under fire curves", Journal of Korean Tunnelling and Underground Space Association, Vol. 16, No. 3, pp. 311-320. DOI |
4 | Hertz, K.D. (2003), "Limits of spalling of fire-exposed concrete", Fire Safety Journal, Vol. 38, No. 2, pp. 103-116. DOI |
5 | ITA (2004), Guidelines for structural fire resistance for road tunnels, Working Group No. 6 Maintenance and Repair, pp. 21. |
6 | JCI (2002), Report of research committee on fire safety of concrete structures, Japan Concrete Institute (JCI) [in Japanese]. |
7 | Khoury, G.A. (1992), "Compressive strength of concrete at high temperatures: a reassessment", Magazine of Concrete Research, Vol. 44, No. 161, pp. 291-309. DOI |
8 | Khoury, G.A. (2002), "Passive protection against fire", Tunnels & Tunnelling International, Vol. 34, No. 11, pp. 40-42. |
9 | Khoury, G.A., Majorana, C.E., Pesavento, F., Schrefler, B.A. (2002), "Modelling of heated concrete", Magazine of Concrete Research, Vol. 54, No. 2, pp. 77-101. DOI |
10 | Kodur, V.K.R., Phan, L. (2007), "Critical factors governing the fire performance of high strength concrete systems", Fire Safety Journal, Vol. 42, No. 6-7, pp. 482-488. DOI |
11 | MOLIT (2020), Road tunnel disaster prevention facility installation and management guidelines, Ministry of Land, Infrastructure and Transport. |
12 | Phan, L.T. (1996), Fire performance of high-strength concrete: a report of the state-of-the-art, NISTIR 5934, National Institute of Standards and Technology, pp. 59-60. |
![]() |