References
- J. Y. Park and C. J. Lee, "Principal Component Analysis Based Method for Effective Fault Diagnosis", J. Korean Soc. Saf., Vol. 29, No. 10, pp. 73-77, 2014. https://doi.org/10.14346/JKOSOS.2014.29.4.073
- http://report.safedu.org/
- http://www.chemnavi.or.kr/main.do
- M. A. Rana, Y. Guo and M. S. Mannan MS, "Use of Water Spray Curtain to Disperse LNG Vapor Clouds", Journal of Loss Prevention in the Process Industries, Vol. 23, No. 1, pp. 77-88, 2010. https://doi.org/10.1016/j.jlp.2009.06.003
- J. McQuaid and R. D. Fitzpatrick, "Air Entrainment by Water Sprays: Strategies for Application to the Dispersion of Gas Plumes", Journal of Occupational Accidents., Vol. 5, No. 2, pp. 121-133, 1983. https://doi.org/10.1016/0376-6349(83)90016-0
- J. A. Suardin, R. Qi, R. Benjamin, M. Rana, Y. Zhang and M. S. Mannan, "Application of Fire Suppression Materials on Suppression of LNG Pool Fires", Journal of Loss Prevention in the Process Industries, Vol. 24, No. 1, pp. 63-75, 2011. https://doi.org/10.1016/j.jlp.2010.06.010
- V. Busini and R. Rota, "Influence of the Shape of Mitigation Barriers on Heavy Gas Dispersion", Journal of Loss Prevention in the Process Indus tires, Vol. 29, pp. 13-21, 2014. https://doi.org/10.1016/j.jlp.2014.01.001
- D. Liu and J. Wei, "Modelling and Simulation of Continuous Dense Gas Leakage for Emergency Response Application", Journal of Loss Prevention in the Process Industries, Vol. 48, pp. 14-20, 2017. https://doi.org/10.1016/j.jlp.2017.03.026
- M. R. Swain and J. Shriber, "Comparison of Hydrogen, Natural Gas, Liquefied Petroleum Gas, and Gasoline Leakage in a Residential Garage", Energy and Fuels, Vol. 12, No. 1 pp. 83-89, 1998. https://doi.org/10.1021/ef970111s
- Committee on Energy and Commerce, "Safe Aboveground Storage Tanks", Washington DC, U.S. Government Printing Office, 1994.
- Y. Kawg, J. Oak, S. Yoon and S. Jung, "A Study on the Safety Distance of Benzene and Acrylonitrile Releases in Sccordance with Dike and Hole Size", Journal of the Korean Institute of Gas, Vol. 22, No. 1, pp. 18-25, 2018. https://doi.org/10.7842/KIGAS.2017.22.1.18
- C. Shin, J. H. Park and J. Yoon, "Analysis on the Risk of the Impermeable Concrete Bottom of Dikes for Nitric Acid Storage Tanks", J. Korean Soc. Saf., Vol. 31, No. 3, pp. 53-59, 2016. https://doi.org/10.14346/JKOSOS.2016.31.3.53
- KOSHA, "Korea Occupational Safety and Health Agency, Technical Specifications for the Dike Installation", 2012.
- Frank P. Less, "Loss Prevention in the Process Industries", Butterworth, pp. 417, 1986.