• Title/Summary/Keyword: fire fighting safety

Search Result 224, Processing Time 0.027 seconds

A Study to Prevent the Fire in Residential Buildings (주거용 건축물의 화재 예방에 관한 고찰)

  • Park, Kyong-Jin;Kim, Hye-ree;Lee, Bong-Woo;Park, Shin-young
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.2_2
    • /
    • pp.307-312
    • /
    • 2020
  • This study presents problems and improvement measures for the supply rate of single-alarm detector and fire extinguisher installed in households. Statistics from the NFDS show that 18 percent of all fires and 45 percent of deaths occurred in residential buildings over the past eight years. It was less than 60% that households be equipped rate of basic fire-fighting systems by 2019. In this study, I analyzed the law and statistics of fire to devise a method for fire safety. I proposed that the basic fire-fighting systems is be equipped in households. Like this : First, a free distribution policy for the over 60 years of age and Areas where is fire engine difficult to enter. Second, the policy of adopting safety pay in disaster. Third, the policy of expanding supply through the revision of the Licensed Real Estate Agents Act. Fourth, the policy of self-regulating installation by safety education and set up a data base system. Fifth make a law of household's National Fire Safety Standards.

The Improvement of the Specific Target for Fire Fighting of Fire Safety Grade System (특정소방대상물의 방화관리 등급체계 개선방안)

  • Kwak, Chang-Sik;Woo, Seong-Cheon;Chae, Jin
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.162-171
    • /
    • 2010
  • According to the development of industry, many aspects of society have been changed and a living environment has been more convenient than before. However, factors of fire risk are increased because of society which is becoming complex. Moreover, a building built in recently is becoming high-rise and intelligent. Then losses of life and property increase continually. Thus, an institutional strategy which can solve this problem is needed. The purpose of this research is to state a problem of specific a building managing strategy and suggests a reformation of the fire safety grade system of a specific building. The suggested ideas are an adoption of fire risk evaluation of a building, tentatively named "Fire Safety Corporation" establishment, reclassification of the fire safety grade system of a specific building, and newly making fire safety managers of ultra-high buildings and underground structures.

A Study on Powder Fire Extinguisher Design with RULA Technique Used (RULA 평가기법을 활용한 분말소화기 디자인 연구)

  • Kang, Chaewoo;Kim, Dueknam
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.117-123
    • /
    • 2017
  • This study was intended to find methods of fire extinguishing system designs that can improve the equipment's usability. In this study, the fire suppression experiment through fire extinguishers and the data drawn through the experiment were analyzed, and then the guideline for the improvement of designs was presented. The procedure is as follows. A fire suppression experiment with the use of fire extinguishers was done by 43 average adults. The whole process of the fire suppression was videotaped, and then captured major scenes were analyzed with the use of RULA, a human engineering measurement tool. The analyzed data were divided into 4 steps, and then the guideline for design improvement was presented. The summary of the study is as follows. Step 1, Fire extinguisher distance step. To reduce overload occurring at the process of holding fire extinguishers suddenly, wheels are attached to the body of extinguishers, or pedestals are installed. Step 2, Fire extinguisher transportation step. The length of hose is extended, or fire fighting water is sprayed far, so that overload of legs occurring at the process of travel can be reduced. In addition, the weight of fire extinguisher shouldn't be over 2 kg. Step 3, Safety pin removal stage. Safety pins should be applied with button type, so that excessive posture of lower limbs and excessive twisting of wrists won't happen during safety pin removal process. Besides, safety pins should be designed for easy identification and operation. Step 4, Fire extinguishing agent spraying step. To reduce overload occurring at sudden spraying of fire fighting water, pressure should be increased gradually until high pressure. With the above study results applied to existing fire extinguisher design, it may contribute to reducing any fire damage.

A Study on the Comparative Analysis of Fire-Fighting Ambulances about the Aspects of Safety and Efficiency using the Question Investigation (설문조사를 이용한 국내 소방 구급자동차의 안전성과 효율성 측면에서의 비교 분석에 관한 연구)

  • Shin, Dong-Min;Kim, Seung-Yong;Han, Yong-Taek
    • Fire Science and Engineering
    • /
    • v.29 no.2
    • /
    • pp.44-53
    • /
    • 2015
  • This study is a survey research to improve the fire-fighting ambulance interior design safer and more efficient to identify the type of structure and functional problems 119 ambulance. When the paramedics and four degrees to over 755 people modify the target report and related literature on the future development of an ambulance for patient safety at the 2007 British National Patients Safety Agency (NPSA) and was used as a complementary tool. General characteristics questionnaire was composed of items for your design improvements for ambulance promote safety and efficiency. The data were collected by distributing a questionnaire e-mail or in person. The collected data were processed using the SPSS 20.0 statistical program, the general characteristics as frequency analysis, percentage, ambulance interior design improvement-related items were analyzed using the chi-square verified. As a result, this research elicited that vans converted fire ambulance cars have a problem with the narrow interior space and truck converted fire ambulance cars should be comfortable to drive in ride quality. In addition, we also found that the improvement of paramedics treatment position and the paramedic's personnel safety belt are required. Based on these results, we propose that a number of improvements are needed in the fire-fighting ambulance car.

Study on Space Organization Based on Significance Assessment of Interior Space Factors at 119 Safety Center (119 안전센터 실내공간요소 중요도 평가에 의한 공간구성연구)

  • Kim, Sung-Ju;Kim, Moon-Duk
    • Korean Institute of Interior Design Journal
    • /
    • v.23 no.4
    • /
    • pp.257-266
    • /
    • 2014
  • This study has been performed to come up with any rational way for responding to the functions of fire-fighting spaces newly required by the changing social paradigms and to seek for the approach to designing fire-fighting spaces by taking into account the psychological and behavioral factors of fire-fighters who are exposed stress of operations. In particular, it is to satisfy any physical and functional requirements as special working-spaces and to reflect the psychological and behavioral approach to the workers who are forced to be at standby for a long time, which is the characteristic of their operation, to designing. Accordingly, for fundamental appreciation of whether or not such space programs as space organization needed for operational function are being practiced actively, the fire-fighting headquarters of Incheon City has been selected for the research. First, in the process of assessing the trend of organizing the space at safety centers for the recent 20 years, those built more than 20 years ago were left out from the space selection for the research. Second, those with less than 20 operators also were excluded. Third, among those completed in the same year, only one was selected, which was to avoid overlapping, with the consideration its regional representative nature for applying the safety centers in the jurisdiction of the headquarters equally. The study was performed through the visits to and the actual inspections by surveys at the selected 119 Safety Centers as well as the reviews of literature based on case studies. And for the assessment of significance, surveys and analysis of reliability and factors were carried out. The actual users of Safety Centers were picked as objects for the assessment of significance of space factors at 119 Safety Centers, which revealed that there are five types of dimensions for factor-analyzing standard with which users estimate any significance, which are "Area of Mobilization Preparation and Return" "Area of Standby" "Area of Working Activities" "Area of Employ Welfare" and "Area of Support".

The study on the operation of fire fighting vehicle for a long railway tunnel (장대터널용 소방차량의 운용에 관한 연구)

  • Kwon, Tae-Soon;Park, Won-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.516-521
    • /
    • 2016
  • In this study, we investigated the operation of railroad fire fighting vehicles against fires on trains in a long railway tunnel. In recent years, long railway tunnels (more than 10 km in length) have been built and the number of such tunnels, such as the Geumjeong tunnel (20.3 km in length) on the Gyeongbu high speed line, Solan tunnel (16.7 km in length) on the Yeongdong line and Yulhyeon tunnel (50.3 km in length) on the Suseo high speed line which is scheduled to be opened in the second half of 2016, is increasing. Significant damage is to be expected, due to the increased evacuation time and limited accessibility of fire services when the train is stopped by an urgent fire in the tunnel. Special fire fighting vehicles capable of running on rails have been developed and operated in overseas advanced countries. Therefore, a fire-response system using Unimog vehicles, which can run on road and rail, instead of road vehicles, is necessary. The characteristics of the railway tunnel and thermal environmental change caused by a train fire in a tunnel were analyzed in this study. Also, the operational requirements of the railroad fire fighting vehicles were evaluated by taking into account the specifications of the railroad fire fighting vehicles under development.

Fire and Evacuation Analysis in Environmental Energy Facilities (환경에너지 시설내 화재 및 피난해석)

  • Jeon, Yong-Han;Kim, Jong-Yoon
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.84-90
    • /
    • 2019
  • In this study, a fire and evacuation inside an electronic equipment room in environmental energy facilities were conducted and evaluated using a numerical analysis method. In the fire simulation, the visual distance, temperature distribution, and CO concentration distribution were analyzed using FDS. Based on the results, the Pathfinder program, which is an evacuation simulation, was used to calculate the evacuation time of the occupants and derive an evacuation safety evaluation. As a result, the Available safe Egress time (ASET) of P-01 and P-05 was 203.3 and 398.6 s, respectively. For the Required safety Egress time (RSET) results, all evacuees were evacuated at all points and the safety of the evacuee was secured this simulation showed that the safety evaluation is based on the non - operation of the fire - fighting equipment to improve the safety, making it possible to secure better evacuation safety performance owing to the fire of other fire - fighting facilities.

A Study on Development of Assessment Criteria for Safety City of Fire Fighting Area (소방방재분야의 안전도시 평가기준 개발에 관한 연구)

  • Choi, Kyu-Chool
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.218-228
    • /
    • 2009
  • The basic law about disaster and safety management and the fire fighting law state that the central government and the local governments are responsible for protecting the life and assets of the people. The well-fare developed nations have developed and are implementing diverse safety programs with making safe cities as their prime objective. Our nation has not yet practiced such actions. However, it is in demand to evaluate what safety policies are practiced by local governments for the people and to inform the people of those. Therefore, this research developed and suggests the assessment criteria and the assessment method to evaluate the safety level of a city by assessing the safety of buildings and facilities.

  • PDF

A Study on the Improvement of Fire Safety in high-rise Building Construction in Legal aspects (법규적 측면에서 고찰한 고층 건축물 공사현장 화재안전 확보방안)

  • Park, Chan-Seok;Jeong, Il-Kyun
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.1
    • /
    • pp.21-32
    • /
    • 2015
  • High rising of the buildings offers a number of risk factors than ever before with regard to fire prevention. Especially in the construction site of high-rise buildings, people waste golden-time during the evacuation because temporary fire fighting facilities are not installed and transferred to a large fire because of fire suppression failure. In this study, the researcher derives the problems of fire protection in high-rise buildings construction sites and proposed the measures in such the legal aspects as fire building construction code and etc. There are the legal improvements such as orders of construction suspension in the problems of fire safety, appointing fire safety manager, temporary fire protection installation standards, enhancing penalty provisions regarding the use of fire, operating self fire brigade, confirming on-site after completing fire-protection facalities, establishment or strengthening special fire-protection investigations.

A Survey on the Performance-based Design Status of Fire-fighting Facilities through the Whole Design Drawings and Specifications (설계도서 전수조사를 통한 소방시설분야 성능위주설계 현황조사)

  • Jeon, Eun-Goo;Bae, Young-Hoon;An, Sung-Ho;Hwang, Cheol-Hong;Hong, Won-Hwa;Choi, Jun-Ho
    • Fire Science and Engineering
    • /
    • v.33 no.5
    • /
    • pp.155-162
    • /
    • 2019
  • In Korea, the relevant laws and regulations for fire safety in buildings have been revised. Since 2011, Performance-based Design has been conducted for large-scale or high-rise buildings. However, the Korea's performance-based design is still at a level where life safety evaluation using fire and evacuation simulation tools is compared with existing methods. Although related studies have been conducted continuously for the mandatory performance-based design, the fact that it is relatively unsatisfactory for design and construction of fire-fighting facilities as it mainly focuses on administrative and institutional improvement measures or computer simulation. This study collected 91 performance-based design documents that were carried out nationwide at the initial stage of implementation until 2016 to analyze the status of performance-based design of fire-fighting facilities. As a result, fire-fighting facilities, except for fire extinguish system facilities, were not properly designed for performance. Furthermore, the designers found that if corresponding facilities or higher-level equipment with upgraded performance is additionally installed, the performance-based design fared well compared to the existing the prescriptive-based design.