This study was intended to find methods of fire extinguishing system designs that can improve the equipment's usability. In this study, the fire suppression experiment through fire extinguishers and the data drawn through the experiment were analyzed, and then the guideline for the improvement of designs was presented. The procedure is as follows. A fire suppression experiment with the use of fire extinguishers was done by 43 average adults. The whole process of the fire suppression was videotaped, and then captured major scenes were analyzed with the use of RULA, a human engineering measurement tool. The analyzed data were divided into 4 steps, and then the guideline for design improvement was presented. The summary of the study is as follows. Step 1, Fire extinguisher distance step. To reduce overload occurring at the process of holding fire extinguishers suddenly, wheels are attached to the body of extinguishers, or pedestals are installed. Step 2, Fire extinguisher transportation step. The length of hose is extended, or fire fighting water is sprayed far, so that overload of legs occurring at the process of travel can be reduced. In addition, the weight of fire extinguisher shouldn't be over 2 kg. Step 3, Safety pin removal stage. Safety pins should be applied with button type, so that excessive posture of lower limbs and excessive twisting of wrists won't happen during safety pin removal process. Besides, safety pins should be designed for easy identification and operation. Step 4, Fire extinguishing agent spraying step. To reduce overload occurring at sudden spraying of fire fighting water, pressure should be increased gradually until high pressure. With the above study results applied to existing fire extinguisher design, it may contribute to reducing any fire damage.
Keywords
RULA; fire extinguisher; product design; prevention of disaster;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 S. T. Gwon, "Professional Engineer Fire Fighting", Yemoonsa, pp. 215-217, 2016.
2 M. S. Heo, "Firefighting Machine Facility Theory", Seoul: Dongil, pp. 31-81, 2004.
3 D. H. Kee and K. H. Park, "Comparison of Posture Classification Schemes of OWAS, RULA and REBA", Journal of the Korean Society of Safety, Vol.20 No.2, pp. 127-132, 2005.
4 D. H. Ki and K. T. Lee and J. H. Park and G. G. Choi and "Human Engineering for Industrial Safety and Health Managers", Hangyeongsa, pp. 243-350, 2010.
5 H. Y. Kim, "Human Engineering Engineer", heongmungak, pp. 590-598, 2006.
6 L. McAtamney and E. N. Corlett, "RULA: A Rapid Upper Limb Assessment Tool", Contemporary Ergonomics, Vol. 4, pp. 286-291, 1994.
7 C. S. Keum, "A Study on the Variation in Action Levels of Various MSD Workload Evaluation Tools", M.A Thesis, Inha University, pp. 10-14, 2012.
8 S. R. Chang, "A Study for Prevention of Musculoskeletal Disorders Using Digital Human Simulation in the Shipbuilding Industry", Journal of the Korean Society of Safety, Vol.22 No.3, pp. 81-87, 2007.
9 S. J. Im, "AN Empirical Study on Quantitative Workrelatedness Forsymptoms of Musculorskeletal Disorders", Ph. D Thesis, Inha University, pp. 46-47, 2015.
10 H. G. Rho, "Analysis of the Social Survey using Spss / Amos", Hyungseul Publishing Networks, pp. 13-18, 2007.
11 D. S. Kim, "Industrial Human Engineering", Hyeongseol Publisher, pp. 273-277, 2006.
12 G. J. Han, "Understanding of Chromatics", Kimoondang Publishing Co., pp. 212-234, 2009.