• Title/Summary/Keyword: film coefficient

Search Result 1,073, Processing Time 0.03 seconds

Development of Semi-basement Type Greenhouse Model for Energy Saving

  • Kim, Seoung Hee;Joen, Jong Gil;Kwon, Jin Kyeong;Kim, Hyung Kweon
    • Journal of Biosystems Engineering
    • /
    • v.41 no.4
    • /
    • pp.328-336
    • /
    • 2016
  • Purpose: The heat culture areas of greenhouses have been continuously increasing. In the face of international oil price fluctuations, development of energy saving technologies is becoming essential. To save energy, auxiliary heat source and thermal insulation technologies are being developed, but they lack cost-efficiency. The present study was conducted to save energy by developing a conceptually new semi-basement type greenhouse. Methods: A semi-basement type greenhouse, was designed and constructed in the form of a three quarter greenhouse as a basic structure, which is an advantageous structure to inflow sunlight. To evaluate the performance of the developed greenhouse, a similar structured general greenhouse was installed as a control plot, and heating tests were conducted under the same crop growth conditions. Results: Although shadows appeared during the winter in the semi-basement type greenhouse due to the underground drop, the results of crop growth tests indicated that there were no differences in crop growth and development between the semi-basement type greenhouse and the control greenhouse, indicating that the shadows did not affect the crop up to the height of the crop growing point. The amount of fuel used for heating from January to March was almost the same between the two greenhouses for tests. The heating load coefficients of the experimental greenhouses were calculated as $3.1kcal/m^2{\cdot}^{\circ}C{\cdot}h$ for the semi-basement type greenhouse and $2.9kcal/m^2{\cdot}^{\circ}C{\cdot}h$ for the control greenhouse. Since the value is lower than the double layer PE (polyethylene) film greenhouse value of $3.5kcal/m^2{\cdot}^{\circ}C{\cdot}h$ from a previous study, Tthe semi-basement type greenhouse seemed to have energy saving effects. Conclusions: The semi-basement type greenhouse could be operated with the same fuel consumption as general greenhouses, even though its underground portion resulted in a larger volume, indicating positive effects on energy saving and space utilization. It was identified that the heat losses could be reduced by installing a thermal curtain of multi-layered materials for heat insulation inside the greenhouse for the cultivation of horticultural products by installing thermal curtain of multi-layered materials for heat insulation inside the greenhouse, it was identified that the heat losses could be reduced.

Interfacial disruption effect on multilayer-films/GaN : Comparative study of Pd/Ni and Ni/Pd films

  • 김종호;강희재;김차연;전용석;서재명
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.113-113
    • /
    • 2000
  • 직접천이형 wide band gap(3.4eV) 반도체중의 하나인 GaN를 청색 및 자외선 laser diode, 고출력 전자장비 등으로 응용하기 위해서는 낮은 접합저항을 갖는 Ohmic contact이 선행되어야 한다. 그러나 만족할만한 p-type GaN의 Ohmic contact은 아직 실현되고 있지 못하며, 이는 GaN와 접합 금속과의 구체적인 반응의 연구를 필요로 한다. 본 연구에서 앞서 Pt, Pt, Ni등의 late transition metal을 p-GaN에 접합시킨 결과 이들은 접합 당시 비교적 평탄하나 후열 처리과정에서 비교적 낮은 온도에서 기판과 열팽창계수의 차이로 인하여 평탄성을 잃어버리면서 barrier height가 증가한다는 사실을 확인하였다. 따라서 본 연구에서는 이러한 열적 불안정성을 극복하기 위하여 Ni과 Pd를 차례로 증착하고 가열하면서 interfacial reaction, film morphology, Fermi level의 움직임을 monchromatic XPS(x-ray photoelectron spectroscopy) 와 SAM(scanning Auger microscopy) 그리고 ex-situ AFM을 이용하여 밝히고자 하였다. 특히 후열처리에 의한 계면 반응에 수반되는 구성 금속원소 간의 합금현상과 금속 층의 평탄성이 밀접한 관계가 있다는 것을 확인하였다. 이러한 합금과정에서 나타나는 금속원소들의 중심 준위의 이동을 체계적으로 규명하기 위해서 Pd1-xNix와 Pd1-xGax 합금들의 표준시료를 arc melting method로 만들어 농도에 따른 금속원소들의 중심 준위의 이동을 측정하여, Pd/Ni/p-GaN 및 Ni/Pd/p-GaN 계에서 열처리 온도에 따른 interfacial reaction을 확인하였다. 그 결과 두 계가 상온에서 nitride 및 alloy를 형성하지 않고 고르게 증착되고, 열처리 온도를 40$0^{\circ}C$에서 $650^{\circ}C$까지 증가시킴에 따라 계면반응의 부산물인 metallic Ga은 증가하고 있으마 nitride는 여전히 형성되지 않는 것을 확인하였다. 증착당시 Ni이 계면에 있는 Pd/Ni/p-GaN의 경우에는 52$0^{\circ}C$까지의 열처리에 의하여 Ni과 Pd가 골고루 섞이고 그 평탄성도 유지되고 barier height의 변화도 없었다. 더 높은 $650^{\circ}C$ 가열에 의해서는 surface free energy가 작은 Ga의 활발한 편석 현상으로 인해 표면은 Ga이 풍부한 Pd-Ga의 합금층으로 덮이고, 동시에 작은 pinhole들이 발생하며 barrier height도 0.3eV 가량 증가하게 된다. 반면에 증착당시 Pd이 계면에 있는 Ni/Pd/p-GaN의 경우에는 40$0^{\circ}C$의 가열까지는 두 금속이 그들 계면에서부터 섞이나, 52$0^{\circ}C$의 가열에 의해 이미 barrier height가 0.2eV 가량 증가하기 시작하였다. 더 높은 $650^{\circ}C$가열에 의해서는 커다란 pinhole, 0.5eV 가량의 barrier height 증가, Pd clustering이 동시에 관찰되었다. 따라서 Ni과 Pd의 일함수는 물론 thermal expansion coefficient가 거의 같으며 surface free energy도 거의 일치한다는 점을 감안하면, 이렇게 뚜렷한 열적 안정성의 차이는 GaN와 contact metal과의 반응시작 온도(disruption onset temperature)의 차이에 기인함을 알 수 있었다. 즉 계면에서의 반응에 의해 편석되는 Ga에 의해 박막의 strain이 이완되면, pinhole 등의 박막결함이 줄어 들고, 이는 계면의 N의 out-diffusion을 방지하여 p-type GaN의 barrier height 증가를 막게 된다.

  • PDF

Friction Characteristics of DLC and WC/C (DLC와 WC/C의 마찰특성)

  • Kim, Dong-Wook;Kim, Kyung-Woong
    • Tribology and Lubricants
    • /
    • v.27 no.6
    • /
    • pp.308-313
    • /
    • 2011
  • In this study, friction tests were performed in order to investigate the effect of sliding velocity and normal load on the friction characteristics of DLC (a-C:H) and WC/C (a-C:H:W) using a ball-on-disk type friction tester. DLC and WC/C were deposited on AISI 52100 steel balls. Friction tests against carburized SCM 415 Cr-Mo steel disks were carried out under various sliding velocity (0.1, 0.78, 1.56, 3.13, 6.25, 12.5, 25, 50 and 100 mm/s) and normal load (2.4, 4.8 and 9.6 N) conditions while the relative humidity was 20~40 % R.H. and air temperature was $16{\sim}24^{\circ}C$. As results, kinetic friction coefficients of DLC and WC/C were obtained under each test condition. The results show that the kinetic friction coefficients of DLC and WC/C generally increase with the increase in sliding velocity. And, under the same sliding velocity condition, the kinetic friction coefficients are almost constant regardless of normal load. In addition, the kinetic friction coefficients of DLC are lower than those of WC/C under the same test conditions.

Facilitated Oxygen Transport through a Polyethersulfone Membrane Containing Cobalt Tetraphenylporphyrin-Benzylimidazole (Cobalt Tetraphenylporphyrin-benzylimidazole을 포함한 산소 촉진수송막)

  • Lee, Seung Hwan;Park, Se Hyung;Park, Jung Hoon
    • Membrane Journal
    • /
    • v.28 no.6
    • /
    • pp.424-431
    • /
    • 2018
  • The gas separation performance of a mixed membrane structure based on a mixture of polyethersulfone (PES) and cobalt tetraphenylporphyrin-benzylimidazole (CoTpp-BIm) as an oxygen carrier was investigated. The CoTpp-BIm mixed PES membrane had an asymmetric structure with a mixture of finger structure and sponge-like structure, and the upper surface was dense. The gas separation performance test was carried out using $94%\;N_2$ gas and $6%\;O_2$ mixed gas. Oxygen and nitrogen permeability coefficients were measured at ${\Delta}P$ ranging from 15 to 228 cmHg and the permeate side of the PES membrane was maintained at vacuum level. The oxygen permeability coefficient of CoTpp-BIm mixed PES membranes increased as supplied pressure was decreased. When the supply pressure was 15 cmHg, the gas permeability ($P_{O_2}$) was 6676 Barrer, the $O_2/N_2$ selectivity (${\alpha}$) was 6.1, and the promoting factor (F) was 2.39. Based on these results, it was confirmed that the addition of CoTpp-BIm to the PES film improved the oxygen separation characteristics.

Interface structure and anisotropic strain relaxation of nonpolar a-GaN on r-sapphire

  • Gong, Bo-Hyeon;Jo, Hyeong-Gyun;Song, Geun-Man;Yun, Dae-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.31-31
    • /
    • 2010
  • The growth of the high-quality GaN epilayers is of significant technological importance because of their commercializedoptoelectronic applications as high-brightness light-emitting diodes (LEDs) and laser diodes (LDs) in the visible and ultraviolet spectral range. The GaN-based heterostructural epilayers have the polar c-axis of the hexagonal structure perpendicular to the interfaces of the active layers. The Ga and N atoms in the c-GaN are alternatively stacked along the polar [0001] crystallographic direction, which leads to spontaneous polarization. In addition, in the InGaN/GaN MQWs, the stress applied along the same axis contributes topiezoelectric polarization, and thus the total polarization is determined as the sum of spontaneous and piezoelectric polarizations. The total polarization in the c-GaN heterolayers, which can generate internal fields and spatial separation of the electron and hole wave functions and consequently a decrease of efficiency and peak shift. One of the possible solutions to eliminate these undesirable effects is to grow GaN-based epilayers in nonpolar orientations. The polarization effects in the GaN are eliminated by growing the films along the nonpolar [$11\bar{2}0$] ($\alpha$-GaN) or [$1\bar{1}00$] (m-GaN) orientation. Although the use of the nonpolar epilayers in wurtzite structure clearly removes the polarization matters, however, it induces another problem related to the formation of a high density of planar defects. The large lattice mismatch between sapphiresubstrates and GaN layers leads to a high density of defects (dislocations and stacking faults). The dominant defects observed in the GaN epilayers with wurtzite structure are one-dimensional (1D) dislocations and two-dimensional (2D) stacking faults. In particular, the 1D threading dislocations in the c-GaN are generated from the film/substrate interface due to their large lattice and thermal coefficient mismatch. However, because the c-GaN epilayers were grown along the normal direction to the basal slip planes, the generation of basal stacking faults (BSFs) is localized on the c-plane and the generated BSFs did not propagate into the surface during the growth. Thus, the primary defects in the c-GaN epilayers are 1D threading dislocations. Occasionally, the particular planar defects such as prismatic stacking faults (PSFs) and inversion domain boundaries are observed. However, since the basal slip planes in the $\alpha$-GaN are parallel to the growth direction unlike c-GaN, the BSFs with lower formation energy can be easily formed along the growth direction, where the BSFs propagate straightly into the surface. Consequently, the lattice mismatch between film and substrate in $\alpha$-GaN epilayers is mainly relaxed through the formation of BSFs. These 2D planar defects are placed along only one direction in the cross-sectional view. Thus, the nonpolar $\alpha$-GaN films have different atomic arrangements along the two orthogonal directions ($[0001]_{GaN}$ and $[\bar{1}100]_{GaN}$ axes) on the $\alpha$-plane, which are expected to induce anisotropic biaxial strain. In this study, the anisotropic strain relaxation behaviors in the nonpolar $\alpha$-GaN epilayers grown on ($1\bar{1}02$) r-plane sapphire substrates by metalorganic chemical vapor deposition (MOCVO) were investigated, and the formation mechanism of the abnormal zigzag shape PSFs was discussed using high-resolution transmission electron microscope (HRTEM).

  • PDF

Development of a Thermoplastic Oral Compensator for Improving Dose Uniformity in Radiation Therapy for Head and Neck Cancer (두경부암 방사선치료 시 선량 균일도 향상을 위한 Thermoplastic 구강 보상체의 개발)

  • Choi, Joon-Yong;Won, Young-Jin;Park, Ji-Yeon;Kim, Jong-Won;Moon, Bong-Ki;Yoon, Hyong-Geun;Moon, Soo-Ho;Jeon, Jong-Byeong;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.269-278
    • /
    • 2012
  • Aquaplast Thermoplastic (AT) is a tissue-equivalent oral compensator that has been developed to improve dose uniformity at the common boundary and around the treated area during radiotherapy in patients with head and neck cancer. In order to assess the usefulness of AT, the degree of improvement in dose distribution and physical properties were compared to those of oral compensators made using paraffin, alginate, and putty, which are materials conventionally used in dental imprinting. To assess the physical properties, strength evaluations (compression and drop evaluations) and natural deformation evaluations (volume change over time) were performed; a Gafchromic EBT2 film and a glass dosimeter inserted into a developed phantom for dose verification were used to measure the common boundary dose and the beam profile to assess the dose delivery. When the natural deformation of the oral compensators was assessed over a two-month period, alginate exhibited a maximum of 80% change in volume from moisture evaporation, while the remaining tissue-equivalent properties, including those of AT, showed a change in volume that was less than 3%. In a free-fall test at a height of 1.5 m (repeated 5 times as a strength evaluation), paraffin was easily damaged by the impact, but AT exhibited no damage from the fall. In compressive strength testing, AT was not destroyed even at 8 times the force needed for paraffin. In dose verification using a glass dosimeter, the results showed that in a single test, the tissue-equivalent (about 80 Hounsfield Units [HU]) AT delivered about 4.9% lower surface dose in terms of delivery of an output coefficient (monitor unit), which was 4% lower than putty and exhibited a value of about 1,000 HU or higher during a dose delivery of the same formulation. In addition, when the incident direction of the beam was used as a reference, the uniformity of the dose, as assessed from the beam profile at the boundary after passing through the oral compensators, was 11.41, 3.98, and 4.30 for air, AT, and putty, respectively. The AT oral compensator had a higher strength and lower probability of material transformation than the oral compensators conventionally used as a tissue-equivalent material, and a uniform dose distribution was successfully formed at the boundary and surrounding area including the mouth. It was also possible to deliver a uniformly formulated dose and reduce the skin dose delivery.

A STUDY ON FRACTURAL BEHAVIOR OF DENTIN-RESIN INTERFACE (상아질-복합레진 접착계면의 파괴거동에 대한 연구)

  • Ryu, Gil-Joo;Choi, Gi-Woon;Park, Sang-Jin;Choi, Kyung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.3
    • /
    • pp.208-221
    • /
    • 2007
  • The fracture toughness test is believed as a clinically relevant method for assessing the fracture resistance of the dentinal restoratives. The objectives of this study were to measure the fracture toughness $(K_{1C})$ and microtensile bond strength of dentin-resin composite interface and compare their relationship for their use in evaluation of the integrity of the dentin-resin bond. A minimum of six short-rod specimens for fracture toughness test and fifteen specimens for microtensile bond strength test was fabricated for each group of materials used. After all specimens storing for 24 hours in distilled water at $37^{\circ}C$, they were tensile-loaded with an EZ tester universal testing machin. Statistical analysis was performed using ANOVA and Tukey's test at the 95% confidence level, Pearson's coefficient was used to verify the correlation between the mean of fracture toughness and microtensile bond strength. FE-SEM was employed on fractured surface to describe the crack propagation. Fracture toughness value of Clearfil SE Bond (SE) was the highest, followed by Adper Single Bond 2 (SB), OptiBond Solo (OB), ONE-STEP PLUS (0S), ScotchBond Multi-purpose (SM) and there was significant difference between SE and other 4 groups (p < 0.05). There were, however, no significant difference among SB, OB, OS, SM (p > 0.05). Microtensile bond strength of SE was the highest, followed by SB, OB, SM, OS and OS only showed significant lower value (p < 0.05). There was no correlation between fracture toughness and microtensile bond strength values. FE-SEM examination revealed that dentin bonding agent showed different film thickness and different failure pattern according to the film thickness. From the limited results of this study, it was noted that there was statistically no correlation between K1C and ${\mu}TBS$. We can conclude that for obtaining the reliability of bond strength test of dentin bonding agent, we must pay more attention to the test procedure and its profound scrutiny.

Development of $14"{\times}8.5"$ active matrix flat-panel digital x-ray detector system and Imaging performance (평판 디지털 X-ray 검출기의 개발과 성능 평가에 관한 연구)

  • Park, Ji-Koon;Choi, Jang-Yong;Kang, Sang-Sik;Lee, Dong-Gil;Seok, Dae-Woo;Nam, Sang Hee
    • Journal of radiological science and technology
    • /
    • v.26 no.4
    • /
    • pp.39-46
    • /
    • 2003
  • Digital radiographic systems based on solid-state detectors, commonly referred to as flat-panel detectors, are gaining popularity in clinical practice. Large area, flat panel solid state detectors are being investigated for digital radiography. The purpose of this work was to evaluate the active matrix flat panel digital x-ray detectors in terms of their modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). In this paper, development and evaluation of a selenium-based flat-panel digital x-ray detector are described. The prototype detector has a pixel pitch of $139\;{\mu}m$ and a total active imaging area of $14{\times}8.5\;inch^2$, giving a total 3.9 million pixels. This detector include a x-ray imaging layer of amorphous selenium as a photoconductor which is evaporated in vacuum state on a TFT flat panel, to make signals in proportion to incident x-ray. The film thickness was about $500\;{\mu}m$. To evaluate the imaging performance of the digital radiography(DR) system developed in our group, sensitivity, linearity, the modulation transfer function(MTF), noise power spectrum (NPS) and detective quantum efficiency(DQE) of detector was measured. The measured sensitivity was $4.16{\times}10^6\;ehp/pixel{\cdot}mR$ at the bias field of $10\;V/{\mu}m$ : The beam condition was 41.9\;KeV. Measured MTF at 2.5\;lp/mm was 52%, and the DQE at 1.5\;lp/mm was 75%. And the excellent linearity was showed where the coefficient of determination ($r^2$) is 0.9693.

  • PDF

Evaluation of 226Ra analysis methods using a gamma-ray spectrometer and a liquid scintillation counter (감마선분광분석기와 액체섬광계수기를 이용한 226Ra 분석법 비교 연구)

  • Ju, Byoung Kyu;Kim, Moon Su;Kim, Hyun Koo;Kim, Dong Su;Cho, Sung Jin;Yang, Jae Ha;Park, Sun Hwa;Kim, Hyoung Seop;Kwon, Oh Sang;Kim, Tae Seung
    • Analytical Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.228-235
    • /
    • 2015
  • The efficiency and applicability of the solid phase extraction disk method in a 226Ra analysis were examined by the gamma ray spectrometer (GRS) method using a Marinelli beaker and the liquid scintillation counter (LSC) method for groundwater. The recovered 226Ra, which was filtered by the solid phase extraction disk, was analyzed using gamma ray spectrometer The disks, which were pretreated for caulking the daughter nuclide, were sealed with polyethylene film. Distilled water was used for the blank value of the 226Ra activity. The recovery values of 214Bi and 214Pb in the solid phase extraction disk, which used 226Ra standard material, were 80% (295.21 Kev) and 104% (351.92 Kev), respectively, which were higher than 75% determined by the LSC. The injection of nitrogen gas into the measuring chamber reduced the interference values by about 10%. The detection limits of the 226Ra activity in a blank sample of 5 L were 0.17~0.40 pCi/L after 80,000 seconds of measuring time. The relationship of the 226Ra activity in the solid phase extraction disk method and in the LSC method in seven groundwater samples showed a correlation coefficient value 0.987, which implies the applicability of the solid phase extraction disk method. The results showed that 226Ra activity in groundwater using the solid phase extraction disk method has the following benefits: simple pretreatment, time saving, high recovery values, a low detection limit, and so on. Compared with the LSC method and the GRS method using the Marinelli beaker for the 226Ra analysis, the solid phase extraction disk method could be useful in groundwater samples with low levels of activities of radionuclides because the method is not restricted by the volume of the sample.

Analysis of browning degree on fresh-cut lotus root (Nelumbo nucifera G.) using image analysis (이미지 분석을 이용한 신선편이 연근의 갈변도 분석)

  • Cho, Jeong-Seok;Kim, Dae-Hyun;Park, Jung-Hoon;Moon, Kwang-Deog
    • Food Science and Preservation
    • /
    • v.20 no.6
    • /
    • pp.760-765
    • /
    • 2013
  • The image analysis as a tool for evaluation of browning degree on fresh-cut lotus root was studied. The fresh-cut lotus root treated as 4 groups (Cont-without any treatment, DB-blanching at $50^{\circ}C$ for 5 min in distilled water, AB-blanching at $45^{\circ}C$ for 5 min in 1% ascorbic acid, CB-blanching at $45^{\circ}C$ for 5 min in 1% citric acid). The samples treated with each methods were packaged with 0.04 mm polyethylene bag ($25cm{\times}30cm$) and stored at $4^{\circ}C$ for 9 days. On the RGB color space, the AB and CB group showed high R, G, B value. On the HSV and CIE $L^*a^*b^*$ color space, the AB and CB group showed low browning area, $a^*$, $b^*$ value and high $L^*$ value. Polyphenol oxidase activity was low in the AB and CB groups in all storage period. This result means that the AB and CB groups were inhibited the development of tissue browning. The result of sensory evaluation also supported this opinion. And the correlation coefficient between sensory evaluation with all color values was over 0.84. Especially, the $L^*$ value showed the highest correlation coefficient (0.93). In conclusion, the image analysis is suitable for analysis of browning degree on fresh-cut lotus root by analyzing diverse color value.