• Title/Summary/Keyword: field-flow fractionation (FFF)

Search Result 36, Processing Time 0.019 seconds

Capability of Thermal Field-Flow Fractionation for Analysis of Processed Natural Rubber

  • Lee, Seong Ho;Eun, Cheol Hun;Anthony R. Plepys
    • Bulletin of the Korean Chemical Society
    • /
    • v.21 no.1
    • /
    • pp.69-74
    • /
    • 2000
  • Applicability of Thermal field flow fractionation (ThFFF) was investigated for the analysis of masticated natural rubber (NR) adhesives produced bya hot melt mastication process. An optimum ThFFF condition for NR analysis was found by using tetrahydrofuran (THF) as a solvent/carrier and a field-programming. Low flowrate (0.3 mL/min) was used to avoid stopping the flow for the sample relaxation. Measured molecular weight distribution was used to monitor degradation of rubber during the mastication process. Rubber samples collected at three different stages of the mastication process and were analyzed by ThFFF. It was found that in an anaerobic process rubber degradation occurs at the resin-mixing (compounding) zone as well as in the initial break-down zone, while in an aerobic process most of degradation occurs at the initial breakdown zone. It was also found that E-beam radiation on NR causes a slight increase in the NR molecular weight due to the formation of a branched structure.

Size Characterization of Urban Airborne Particles Using Sedimentation/Steric Field-Flow Fractionation (Sd/StFFF)

  • Lee, Jae-Yong;Lee, Seung-Ho;Min, Young-Hong;Hyun, Dae-Yeung
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.8
    • /
    • pp.1172-1176
    • /
    • 2003
  • This study aims to investigate the applicability of Sd/StFFF and to develop a method for size characterization of urban airborne particles, focusing primarily on particles larger than about 1 mm. It was found that the airborne concentration vary with time, although no particular seasonal trend was observed. When averaged over time, the airborne concentration was the lowest in the park areas with 99 ㎍/m³. The apartment, industrial, and central city area showed similar levels of the airborne concentrations with 166, 170, and 171 ㎍/m³, respectively. The housing area showed the highest airborne concentration with 201 μg/m³ among all tested areas. A power-programmed Sd/StFFF was used for size analysis of airborne particles with the initial field strength of 300 rpm, $t_a$ = 4, $t_i$ = -16, p = 8, and the flow rate of 7 mL/min. It was found that urban airborne samples were mostly populated by particles having diameters between about 5 to 20 ㎛, although all have broad size distributions ranging up to about 50 ㎛. Under the Sd/StFFF condition used in this study, no significant differences were found in size distributions among the airborne particles collected at different urban sites, and also among those collected at different times.

Stabilization Methods to Separate and Analyze Materials in Seawaters using Fl-FFF (해수중의 물질 분리 및 분석을 위한 Fl-FFF의 안정화 기법)

  • Choi, Soohoon;Lee, Sangyoup;Hong, Seungkwan;Moon, Jihee
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.2
    • /
    • pp.288-294
    • /
    • 2009
  • Flow field-flow fractionation (Fl-FFF) device has been widely used to verify the size and molecular weight of various colloids and organics. The Fl-FFF, however, generally uses carrier solutions with only low to moderate ionic strengths to exclude the high affinity of materials to the membrane under high ionic strength conditions. Thus, materials existing in seawaters have not been accurately analysed based on the hydrodynamic size and molecular weight using current Fl-FFF techniques. The highest ionic strength tested was up to 0.1 M, while seawater ionic strength is about 0.6 M. The aim of this study is to accurately measure the hydrodynamic size of particles under carrier solutions close to seawater conditions with the Fl-FFF. By employing various operating conditions during the Fl-FFF analyses, it was demonstrated that the flow conditions, the concentration of surfactants, and stabilization times were key factors in acquiring compatible data. Results have shown that the cross flow was more influential factor than the channel flow. The concentration of the surfactant was to be at least 0.05% and the minimum 15 hr of stabilization was needed for accurate and reproducible data acquisition under seawater condition.

Separation and growth monitoring of oyster mushroom spores using gravitational field-flow fractionation (GrFFF) (중력 장-흐름 분획법을 이용한 느타리버섯 포자의 분리 및 성장 모니터링)

  • Kim, Sun Tae;Ji, Eun Young;Lee, Jae Chan;Lee, Seungho
    • Analytical Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.262-267
    • /
    • 2013
  • Gravitational field-flow fractionation (GrFFF) is a separation technique that utilizes earth's gravity as the external field. GrFFF is a convenient tool for the size and/or density-based separation of micron-sized particles of various origins. In this study, GrFFF was employed for size-based separation of oyster mushroom spores. Oyster mushroom spores have smooth surface and are of cylindrical to narrow kidney-shapes with 5 to 12 im in longer dimension and 3 to 4 im in shorter dimension, as was confirmed by optical microscope (OM). GrFFF conditions were optimized for separation and characterization of spores by varying the channel flow rate from 0.5 to 1 mL/min. During the GrFFF elution of the spores, 3 fractions were collected to confirm the growth of oyster mushroom spore. The collected fractions were incubated for 30 days in water to examine the influence of the size on the growth of the spores. Results suggested that the oyster mushroom spores collected at the middle part of the GrFFF fractogram grew faster than those collected at the beginning or at the end of the fractogram.

Retention Characteristics of Various Proteins in Flow Field-Flow Fractionation : Effects of pH, Ionic Strength, and Denaturation

  • 송종희;김원숙;박영훈;유의경;이대운
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.10
    • /
    • pp.1159-1164
    • /
    • 1999
  • The study investigated the effect of carrier composition (ionic strength and pH) on the retention of various proteins in flow field-flow fractionation (Flow FFF) as well as the conformational change of Bovine Serum Albumin (BSA) with urea concentration, storage time and temperature. The study found that the retention of protein in Flow FFF increased with the ionic strength of the carrier liquid. Most proteins were well solubilized at pH = 7-8. The hydrodynamic diameters obtained from Flow FFF retention data agree well with theoretical values. The retention increased and the peak shape became distorted at extreme pH conditions of the carrier solution. The selected carrier composition for comparison between the literature value of proteins was 0.05 M tris buffer solution with a pH of 8. Storing BSA at 4 ±2℃ over a period of three months resulted in slow dimerization. Also, in case of the storage of BSA at 37 ±5℃ for one week, the retention of both BSA monomer and dimer increased with the urea concentration. Finally, the structural composition of specific enzymes: malonyl-CoA decarboxylase (MCDC) and malonyl-CoA synthesis (MCS) was determined by using Flow FFF at specific carrier solutions. The molecular weight of the natural MCDC was determined to be 208 kDa, which means it is a homotetramer, while that of the MCS was determined to be 47 kDa, which means it is a monomer.

Separation of Nanomaterials Using Flow Field-Flow Fractionation (흐름 장-흐름 분획기를 이용한 나노물질의 분리)

  • Kim, Sung-Hee;Lee, Woo-Chun;Kim, Soon-Oh;Na, So-Young;Kim, Hyun-A;Lee, Byung-Tae;Lee, Byoung-Cheun;Eom, Ig-Chun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.11
    • /
    • pp.835-860
    • /
    • 2013
  • Recently, the consumption of nanomaterials has been significantly increased in both industrial and commercial sectors, as a result of steady advancement in the nano-technologies. This ubiquitous use of nanomaterials has brought up the concern that their exposure to environments may cause detrimental effects on human health as well as natural ecosystems, and it is required to characterize their behavior in various environmental media and to evaluate their ecotoxicity. For the sake of accomplishing those assessments, the development of methods to effectively separate them from diverse media and to quantify their properties should be requisitely accompanied. Among a number of separation techniques developed so far, this study focuses on Field-Flow Fractionation (FFF) because of its strengths, such as relatively less disturbance of samples and simple pretreatment, and we review overseas and domestic literatures on the separation of nanomaterials using the FFF technique. In particular, researches with Flow Field-Flow Fractionation (FlFFF) are highlighted due to its most frequent application among FFF techniques. The basic principle of the FlFFF is briefly introduced and the studies conducted so far are classified and scrutinized based on the sort of target nanomaterials for the purpose of furnishing practical data and information for the researchers struggling in this field. The literature review suggests that the operational conditions, such as pretreatment, selection of membrane and carrier solution, and rate (velocity) of each flow, should be optimized in order to effectively separate them from various matrices using the FFF technique. Moreover, it seems to be a prerequisite to couple or hyphenate with several detectors and analyzers for quantification of their properties after their separation using the FFF. However, its application has been restricted regarding the types of target nanomaterials and environmental media. Furthermore, domestic literature data on both separation and characterization of nanomaterials are extremely limited. Taking into account the overwhelmingly increasing consumption of nanomaterials, the efforts for the area seem to be greatly urgent.

Separations of polystyrene sulfonate by dual pump field flow fractionation using UF hollow fiber membranes (듀얼펌프 중공사막 흐름 장 흐름 분회법을 사용하여 다당류(Polystyrene sulfonate)의 분리)

  • 정도연;최승렬;이승윤;민병렬
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.05b
    • /
    • pp.192-194
    • /
    • 2004
  • FFF에서 외부장은 시료의 종류에 따라 선택적으로 사용되며, 그 외부장의 종류에 따라 세부기술로 구분되어진다. 원심력(gravitational or centrifugal field)을 외부장으로 사용하는 침강장-흐름분획법(sedimentation FFF)은 지름이 0,05∼1um정도인 콜로이드 입자의 분리에 좋은 방법이다. 온도구배(thermal fradient)를 이용하는 열장-흐름분획법(thermal FFF)은 유기 고분자의 분리 및 고분자의 물성연구에 이용된다.(중략)

  • PDF

Characterization of CdS-quantum dot particles using sedimentation field-flow fractionation (SdFFF) (침강 장-흐름 분획법을 이용한 CdS 양자점 입자의 특성 분석)

  • Choi, Jaeyeong;Kim, Do-Gyun;Jung, Euo Chang;Kwen, HaiDoo;Lee, Seungho
    • Analytical Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.33-39
    • /
    • 2015
  • CdS-QD particles are a nano-sized semiconducting crystal that emits light. Their optical properties show great potential in many areas of applications such as disease-diagnostic reagents, optical technologies, media industries and solar cells. The wavelength of emitting light depends on the particle size and thus the quality control of CdS-QD particle requires accurate determination of the size distribution. In this study, CdS-QD particles were synthesized by a simple ${\gamma}$-ray irradiation method. As a particle stabilizer polyvinyl pyrrolidone (PVP) were added. In order to determine the size and size distribution of the CdS-QD particles, sedimentation field-flow fractionation (SdFFF) was employed. Effects of carious parameters including the the flow rate, external field strength, and field programming conditions were investigated to optimize SdFFF for analysis of CdS-QD particles. The Transmission electron microscopy (TEM) analysis show the primary single particle size was ~4 nm, TEM images indicate that the primarty particles were aggregated to form secondary particles having the mean size of about 159 nm. As the concentration of the stabilizer increases, the particle size tends to decrease. Mean size determined by SdFFF, TEM, and dynamic light scattering (DLS) were 126, 159, and 152 nm, respectively. Results showed SdFFF may become a useful tool for determination of the size and its distribution of various types of inorganic particles.

Development of wet-sampler for collection and fractionation of micron-sized particles (마이크로 입자의 습식 수집 및 분획 장치 개발)

  • Eum, Chul-Hun;Kang, Dong-Young;Lee, Seung-Ho
    • Analytical Science and Technology
    • /
    • v.24 no.6
    • /
    • pp.429-434
    • /
    • 2011
  • In this study, a wet-sampler was developed for collection in water and simultaneous fractionation of micron-sized particles (e.g., pigment, airborne, etc.). In this new device, three cylinders (partially filled with water) through which air was forced to pass for sample collection are connected in a series. Particles of different sizes are collected in different cylinders, allowing simultaneous fractionation. An uniqueness of this new device is that it does not use any membrane filter. Microparticles are collected directly in cylinders filled partially with water. Also the particles are simultaneously fractionated within this device while they are being collected. The new device was employed for collection of airborne particles. The collected airborne particles were fractionated by using sedimentation field-flow fractionation, SdFFF), and observed with an optical microscopy (OM) for size and shape analysis. Also AAS and ICP-AES were used for composition analysis of the airborne particles. It is expected that the new device is applicable to collection and analysis of size distribution of various types of microparticles.