• 제목/요약/키워드: fault tolerant control

검색결과 298건 처리시간 0.023초

Unscented Kalman Filter For Aircraft Sensor Fault Detection

  • Kim, In-Jung;Kim, You-Dan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2335-2339
    • /
    • 2003
  • To prevent the critical situation due to the fault in the aircraft sensor system, the fault tolerant system with triple or quadruple redundancy can be made. However, if the faults are occurred in two or more than sensors simultaneously, the conventional fault detection process, such as cross-channel monitoring, may give the wrong fault alarm. For this case, we can detect the fault by estimating the state vector based on the system dynamics model, which is nonlinear for aircraft. In this paper, we propose the unscented Kalman filter to estimate the nonlinear state vector. This filter utilizes the so-called unscented transformation of sigma points featured the statistical characteristics of the random variable. For verification, we perform the simulations for F-16 aircraft with accelerometers, gyros, GPS and air data system.

  • PDF

Calculation of Distributed Magnetic Flux Density under the Stator-Turn Fault Condition

  • Kim, Kyung-Tae;Hur, Jin;Kim, Byeong-Woo
    • Journal of Power Electronics
    • /
    • 제13권4호
    • /
    • pp.552-557
    • /
    • 2013
  • This paper proposed an analytical model for the distributed magnetic field analysis of interior permanent magnet-type blush-less direct current motors under the stator-turn fault condition using the winding function theory. Stator-turn faults cause significant changes in electric and magnetic characteristic. Therefore, many studies on stator-turn faults have been performed by simulation of the finite element method because of its non-linear characteristic. However, this is difficult to apply to on-line fault detection systems because the processing time of the finite element method is very long. Fault-tolerant control systems require diagnostic methods that have simple processing systems and can produce accurate information. Thus analytical modeling of a stator-turn fault has been performed using the winding function theory, and the distributed magnetic characteristics have been analyzed under the fault condition. The proposed analytical model was verified using the finite element method.

여유 자유도를 갖는 서보 매니퓰레이터의 내고장 제어를 위한 재형상 기법 (Reconfiguration of Redundant Joints for Fault Tolerance of a Servo Manipulator)

  • 박병석;안성호;윤지섭
    • 제어로봇시스템학회논문지
    • /
    • 제10권10호
    • /
    • pp.899-906
    • /
    • 2004
  • In this paper, fault tolerant algorithm is presented for a servo manipulator system. For fault tolerance of a servo manipulator system, reconfiguration algorithm accommodating a motor's failure has been presented. The algorithm considers a transport's degree of freedoms as redundant joints of a servo manipulator. The reconfiguration algorithm recovers the end effector's motion in spite of one motor's failure A modified pseudo inverse redistribution method has been proposed for the reconfiguration algorithm. Numerical examples and hardware tests have been presented to verify the proposed methods.

안전필수 결함허용 USN시스템의 고장률정량화에 관한 연구 (Study on the Quantification of Failure Rate for Safety-critical Fault-tolerant USN System)

  • 신덕호;신경호;조현정;송용수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.1414-1419
    • /
    • 2011
  • In this paper we study the modeling to quantitatively assess the failure rate of USN system designed for fault-tolerant architecture, aiming at applying the world's best domestic USN technology to safety-critical railways. In order to apply the USN system to the safety-critical field like a train control sector that the failures of controllers may cause severe railway accidents such as train collision and derailment, the quantitative reliability and safety evaluation recommended in IEC 62278 must be preceded. We also develop the evaluation model for overall system failure rate for the distributed network structure, which is the characteristics of USN system. Especially, we allocate reliability targets to component units, and present an availability evaluation plan through the plan on the quantitative achievement of failure rate for sensor nodes, gateways, radio-communication network and servers, along with the failure rate model of the overall system considering network operational features.

  • PDF

적응적 결함-허용 다단계 상호연결망 (Adaptive Fault-tolerant Multistage Interconnection Network)

  • 김금호;김영만;배은호;윤성대
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(3)
    • /
    • pp.199-202
    • /
    • 2001
  • In this paper, we proposed and analyzed a new class of irregular fault-tolerant multistage interconnection network named as Extended-QT(Quad Tree) network. E-QT network is extended QT network. A unique path MIN usually is low hardware complexity and control algorithm. So we proposes a class of multipath MIN which are obtained by adding self-loop auxiliary links at the a1l stages in QT(Quad Tree) networks so that they can provide more paths between each source-destination pair. The routing of proposed structure is adaptived and is based by a routing tag. Starting with the routing tag for the minimum path between a given source-destination pair, routing algorithm uses a set of rules to select switches and modify routing tag. Trying the self-loop auxiliary link when both of the output links are unavailable. If the trying is failure, the packet discard. In simulation, an index of performance called reliability and cost are introduced to compare different kinds of MINs. As a result, the prouosed MINs have better capacity than 07 networks.

  • PDF

자기연성을 이용한 동극형 자기베어링의 고장강건 제어 (Fault Tolerant Homopolar Magnetic Bearings with Flux Coupling)

  • 나언주
    • 한국정밀공학회지
    • /
    • 제25권3호
    • /
    • pp.83-92
    • /
    • 2008
  • This paper develops the theory for a fault-tolerant, permanent magnet biased, homopolar magnetic bearing. If some of the coils or power amplifiers suddenly fail, the remaining coil currents change via a novel distribution matrix such that the same magnetic forces are maintained before and after failure. Lagrange multiplier optimization with equality constraints is utilized to calculate the optimal distribution matrix that maximizes the load capacity of the failed bearing. Some numerical examples of distribution matrices are provided to illustrate the theory. Simulations show that very much the same dynamic responses (orbits or displacements) are maintained throughout failure events (up to any combination of 3 coils failed for the 6 pole magnetic bearing) while currents and fluxes change significantly. The overall load capacity of the bearing actuator is reduced as coils fail. The same magnetic forces are then preserved up to the load capacity of the failed.

전자연동장치의 안전성 활동에 관한 연구(II) (A Study on Fault Tolerant Digital Controllers for Programmable Electronic Interlocking System(II))

  • 박재영;이종우
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권12호
    • /
    • pp.667-673
    • /
    • 2006
  • Programmable electronic interlocking system plays key role in railway operation and is closely related to railway accidents, in which the programmable electronic controller of interlocking system may become sources. Redundant digital controllers are adopted as the interlocking controllers to prevent the accidents from the controllers being out of order. The redundant digital controllers being fault tolerant are realized through dual or triplex controllers. In this paper, we calculated safety and availability of the redundant digital controllers using Markov models, demonstrated key part to determine the availability ana the safety.

철도 차량용 통신 네트워트의 이중 마스터 운용 기법 (Double mastering network for train communication)

  • 유흥열;조영조;오상록;홍대식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.355-358
    • /
    • 1998
  • Train control and monitoring system for the railway train requires a reliable real-time communication network. The system have various functions, diagnostics, passenger informations, and fault-tolerant controls. For this system, an international standard called TCN(Train Communication Network) is proposed by IEC and the train industries. The TCN is composed of two layers, wire train bus(WTB) and multifunction vehicle bus(MVB). This paper evaluates the performance of the proposed WTB and modified WTB. And computer simulations are performed. The evaluated results can be used for the fault tolerant network in the railway train system.

  • PDF

비선형계를 위한 퍼지모델 기반 감소차수 미지입력관측자 설계 (Design of a Fuzzy Model Based Reduced Order Unknown Input Observer for a Class of Nonlinear Systems)

  • 이기상
    • 전기학회논문지
    • /
    • 제57권7호
    • /
    • pp.1247-1253
    • /
    • 2008
  • A design method of a T-S fuzzy model based reduced order nonlinear unknown input observer(NUIO) is presented. The fuzzy NUIO is designed based on the parallel distributed compensation(PDC) concept. It consists of a number of the linear UIOs, each of which is designed for each local linear model in the T-S fuzzy model of a class of nonlinear systems. The fuzzy NUIO provides not only the state estimates insensitive to the unknown inputs, for example, disturbances and faults etc., but also the estimates of the unknown inputs. Therefore, It can be employed in the state feedback control and disturbance rejection control of a class of nonlinear systems with unknown disturbances. It also applied to the robust residual generation for the fault detection and isolation systems and to the design of fault tolerant control systems. As an example, the NUIO is applied to an inverted pendulum system to show the state and disturbance estimation performance and to illustrate the fuzzy reduced order NUIO design method.

3레벨 NPC 인버터 개방성 고장 시 중성점 전압변동에 관한 연구 (A Study on the Neutral Point Potential Variation under Open-Circuit Fault of Three-Level NPC Inverter)

  • 박종제;박병건;하동현;현동석
    • 전력전자학회논문지
    • /
    • 제14권4호
    • /
    • pp.333-342
    • /
    • 2009
  • 중성점 클램핑 방식(Neutral Point Clamped) 인버터로 알려져 있는 3레벨 NPC 인버터는 그 구조적 특성상 직류-링크(DC-link) 중성점(Neutral Point)에서 전압이 변동한다. 지금까지 많은 논문에서 이 문제에 대한 연구가 진행되었고 다양한 형태의 해결책들이 제시되었다. 그러나 인버터 내부에서 고장이 발생하여 그에 따른 고장허용제어가 NPC 인버터 시스템에 적용되었을 경우 중성점 전압변동은 정상 운전 시 나타나는 전압변동과 다르게 나타나기 때문에 고장허용 제어에 따른 중성점 전압변동에 대한 분석이 필요하다. 본 논문에서는 삼각파 비교 변조방법을 시스템에 적용하였을 경우 정상운전과 고장 발생 과 고장허용 제어 적용 시 직류-링크 중성점 전압 변동이 어떤 양상으로 나타나는지 분석하고 고장허용 제어에 의한 NPC 인버터의 고장검출 시간과 커패시터의 용량 사이의 관계를 고찰하였다. 시뮬레이션과 실험 결과를 이용하여 이론적 분석의 타당성을 검증하였다.