• 제목/요약/키워드: fast transient response

검색결과 173건 처리시간 0.028초

A Fast Low Dropout Regulator with High Slew Rate and Large Unity-Gain Bandwidth

  • Ko, Younghun;Jang, Yeongshin;Han, Sok-Kyun;Lee, Sang-Gug
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제13권4호
    • /
    • pp.263-271
    • /
    • 2013
  • A low dropout regulator (LDO) with fast transient responses is presented. The proposed LDO eliminates the trade-off between slew rate and unity gain bandwidth, which are the key parameters for fast transient responses. In the proposed buffer, by changing the slew current path, the slew rate and unity gain bandwidth can be controlled independently. Implemented in $0.18-{\mu}m$ high voltage CMOS, the proposed LDO shows up to 200 mA load current with 0.2 V dropout voltage for $1{\mu}F$ output capacitance. The measured maximum transient output voltage variation, minimum quiescent current at no load condition, and maximum unity gain frequency are 24 mV, $7.5{\mu}A$, and higher than 1 MHz, respectively.

가압 분무실내 스프레이 충돌판에서 나타나는 비정상 열전달 측정에 관한 연구 (An Experimental Study on Unsteady Heat Transfer of Spray-Impinging Plate in a Pressurized Chamber)

  • 조창권;이열;구자예
    • 대한기계학회논문집B
    • /
    • 제24권1호
    • /
    • pp.60-67
    • /
    • 2000
  • An experimental investigation on transient heat transfer phenomena of impinging diesel-spray on a flat plate in a pressurized chamber is carried out. A diesel spray is injected from a single-hole nozzle and impinges to a heated flat plate in the chamber. A fast-response thermocouple installed in the top surface of the plate measures the transient variation of surface temperature of the plate under various conditions of the chamber pressures. Utilizing the semi-infinite model, the temporal variation of the heat flux on the plate is determined. Effects of various parameters, such as vertical distances between the nozzle and the plate, radial distances from the injection-axis, and the chamber pressures, on the heat flux characteristics of impinging diesel-spray are studied.

보상형 퍼지 제어기 설계에 관한 연구 (A Study on the Design of Compensated Fuzzy Controller)

  • 추연규;탁한호
    • 한국항해학회지
    • /
    • 제24권3호
    • /
    • pp.141-145
    • /
    • 2000
  • In servo-system which need fast response and accuracy, PID controller has a good steady-state performance, but has a poor transient response performance causing a load be changed. Compared to these features, FLC(Fuzzy Logic Controller) has a good transient response performance for changed load, but has a little Poor steady-state performance. In this paper, Compensated Fuzay Controller which consists of PID controller and FLC is proposed to modify these disadvantages and is examined through simulation to evaluate its functions.

  • PDF

고속 호모폴라 발전기 모델링 및 과도특성 개선 연구 (A Study of Modeling and Transient Characteristics Improvement of High Speed Homo-polar Generator)

  • 김인수;최상호;오성업;성세진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(2)
    • /
    • pp.686-690
    • /
    • 2004
  • This paper describes the performance improvement of transient response and the modeling of small aircraft onboard generator. As the characteristics of the stator coil which are a major parameters of transient response were improved, the characteristics of transient response could be increased, therefore, the improved generator can be satisfied with large and fast load changes. Established the control model of the generator, it could be possible to do the analysis of generator performance, and improve the operational stability of the generator system using the control model.

  • PDF

Ultra-Fast Flash Observatory (UFFO) for early photon measurements from Gamma Ray Bursts

  • 박일흥
    • 천문학회보
    • /
    • 제37권2호
    • /
    • pp.66-66
    • /
    • 2012
  • We describe the space project of Ultra-Fast Flash Observatory (UFFO), which will observe early optical photons from gamma-ray bursts (GRBs) with a sub-second optical response, for the first time. The UFFO will probe the early optical rise of GRBs, opening a completely new frontier in GRB and transient studies, using a fast-response rotatable mirror system which redirects opitical path to telescope instead of slewing of telescopes or spacecraft. In our small UFFO-Pathfinder experiment, scheduled to launch aboard the Lomonosov satellite in June 2012, we use a motorized mirror in our Slewing Mirror Telescope instrument to achieve less than one second optical response after X-ray trigger. We describe the science and the mission of the UFFO project, including a serious version called UFFO-100 which will be launched in 2014. With our program of ultra-fast optical response GRB observatories, we aim to gain a deeper understanding of GRB mechanisms, and potentially open up the z>10 universe to study via GRB as point source emission probes.

  • PDF

PMSM 전류제어기의 속응성 향상에 관한 연구 (A Study of Improvement on the Quickness of Current controller for Permanent Magnet Synchronous Motor)

  • 조수억;이정환;김철우
    • 조명전기설비학회논문지
    • /
    • 제21권8호
    • /
    • pp.136-143
    • /
    • 2007
  • 개선된 지령치 변경부를 가지는 전류제어기는 과도 상태에서의 빠른 응답성과 정상 상태에서의 고정밀도를 가진다. 이 논문에서는 개선된 지령치 변경부가 빠른 과도 응답성을 위하여 동기 PI 제어기를 사용하였다. 전류 제어기의 과도 응답특성은 DC 링크 제어 전압의 부족으로 인해 높은 역기전력 영역에서 많은 문제를 가지고 있다. 이 논문은 지령 전압과 한계 전압을 가지는 개선된 지령치 변경부를 제안하였다.

Insights into fuel behaviour during relatively fast thermal transients based on calculations for two tests of the Halden IFA-507 experiment

  • Grigori Khvostov
    • Nuclear Engineering and Technology
    • /
    • 제55권10호
    • /
    • pp.3801-3807
    • /
    • 2023
  • Outcomes of the project "Comprehensive Verification of the FALCON Code for Calculation of Nuclear Fuel Temperature" relating to calculation of fuel temperature during relatively fast thermal transients are presented. Good prediction capabilities of the FALCON MOD01 code coupled with the GRSW-A code are shown as applied to the data of the TF3 and TF5 tests from the Transient Temperature Experiment IFA-507. The IFA-507 related dataset of the OECD/NEA International Fuel Performance Experiments (IFPE) Database is extended by the reconstructed dynamics of the axial power distribution in the rods during the transient phase of the experiment. Based on the code calculation, the time constant of the thermal fuel response to a power transient is estimated.

Push-Pull Detection 구조 및 빠른 응답 특성을 갖는 LDO 레귤레이터 (LDO Regulator with Improved Fast Response Characteristics and Push-Pull Detection Structure)

  • 이주영
    • 전기전자학회논문지
    • /
    • 제25권1호
    • /
    • pp.201-205
    • /
    • 2021
  • 본 논문에서는 push-pull 감지 회로 구조로 인해 load transient 특성을 개선시킨 LDO를 제안하였다. LDO 레귤레이터 패스 트랜지스터의 입력단과 내부 오차증폭기의 출력단 사이에 제안된 push-pull 감지 회로 구조로 인한 전압 델타 값의 응답 특성을 개선시켜 종래의 LDO 레귤레이터보다 load transient 특성에서 우수한 효과를 가진다. 기존의 LDO 레귤레이터보다 rising time에서는 약 244 ns, falling time에서는 약 90 ns 만큼의 향상된 응답속도를 가진다. 제안된 회로는 Cadence사의 Spectre, Virtuoso 시뮬레이션 tool을 사용하여 samsung 0.13um 공정으로 특성 및 결과를 시뮬레이션 하였다.

선형 이산계의 동적응답을 위한 스펙트럴해석법 (Spectral Analysis Method for the Dynamic Response of Linear Discrete Systems)

  • 김성환;이우식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1654-1659
    • /
    • 2003
  • This paper introduces a fast Fourier transform (FFT)-based spectral analysis method for the transient responses as well as the steady-state responses of linear discrete systems. The force vibration of a viscously damped three-DOF system is considered as the illustrative numerical example. The proposed spectral analysis method is evaluated by comparing with the exact analytical solutions as well as with the numerical solutions obtained by the Runge-Kutta method.

  • PDF

Fast-Response Load Regulation of DC-DC Converter By High-Current Clamp

  • Senanayake, Thilak Ananda;Ninomiya, Tamotsu
    • Journal of Power Electronics
    • /
    • 제4권2호
    • /
    • pp.87-95
    • /
    • 2004
  • A new fast-response high-current clamp DC-DC converter circuit design is presented that will meet the requirements and features of the new generation of microprocessors and digital systems. The clamp in the proposed converter amplifies the current in case of severe load changes and is able to produce high slew rate of output current and capability to keep constant the output voltage. This proposed high-current clamp technique is theoretically loss less, low cost and easy to implement with simple control scheme. This is modified from a basic buck topology by replacing the output inductor with two magnetically coupled inductors. Inductors are difference in inductance, one has large inductance and other has small inductance. The inductor with small inductance will take over the output inductor during fast load transient. It speedup the output current slew rate and reduce the output voltage drop in the case of heavy burden load changes.