• 제목/요약/키워드: factor conditions

검색결과 5,263건 처리시간 0.032초

Free vibrations of fluid conveying microbeams under non-ideal boundary conditions

  • Atci, Duygu;Bagdatli, Suleyman Murat
    • Steel and Composite Structures
    • /
    • 제24권2호
    • /
    • pp.141-149
    • /
    • 2017
  • In this study, vibration analysis of fluid conveying microbeams under non-ideal boundary conditions (BCs) is performed. The objective of the present paper is to describe the effects of non-ideal BCs on linear vibrations of fluid conveying microbeams. Non-ideal BCs are modeled as a linear combination of ideal clamped and ideal simply supported boundary conditions by using the weighting factor (k). Non-ideal clamped and non-ideal simply supported beams are both considered to show the effects of BCs. Equations of motion of the beam under the effect of moving fluid are obtained by using Hamilton principle. Method of multiple scales which is one of the perturbation techniques is applied to the governing linear equation of motion. Approximate solutions of the linear equation are obtained and the effects of system parameters and non-ideal BCs on natural frequencies are presented. Results indicate that, natural frequencies of fluid conveying microbeam changed significantly by varying the weighting factor k. This change is more remarkable for clamped microbeams rather than simply supported ones.

사출 성형 조건에 따른 PC 색상별 수축률 편차에 관한 연구 (A Study on the Shrinkage Deviation in PC-Collors by the Injection Molding Conditions)

  • 정상훤;유중학;홍청민;정현석
    • Design & Manufacturing
    • /
    • 제9권1호
    • /
    • pp.14-17
    • /
    • 2015
  • In the data from synthetic resin makers, there is no shrinkage deviation through injection molding. But, after making the required products, even in the same conditions, there are some size-deviation in colors. Into our research, we checked main factor by the injection molding conditions. Our tests have shown this results, there are some shrinkage deviation in collors and, in the injection molding conditions, packing pressure is the main factor.

  • PDF

다중회귀를 이용한 기후와 오손도 간의 상관관계 분석 (Analysis of the Correlation on the Weather Conditions and the Contamination Degree Using Mu lisle Regression Method)

  • 심규일;최남호;김종석;한상옥
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2001년도 학술대회논문집
    • /
    • pp.199-202
    • /
    • 2001
  • This paper presents the correlation on the contamination degree and weather conditions using the multiple regression of the statistic method. The cotamination is a significant factor in the insulation system. The major factor is natural contamination, and the most is the salt. The salt contamination is occured by the weather conditions. The weather contaminations are wind, precipitation, temperature, relative humidity, etc. The effects of those are different, and the correlation is showed numerically by using the multiple regression method of the statistic method. With this, the estimation of the equivalent salt deposit density(ESDD) becomes possible by the changes of the weather conditions.

  • PDF

과지압 조건에서 해저터널의 연계해석 시 이완하중고 평가 연구 (The estimation of the relaxed rock mass height of a subsea tunnel under the overstressed ground conditions in coupled analysis)

  • 유광호;이동훈
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.716-724
    • /
    • 2008
  • In the case of subsea tunnels, hydro-mechanical coupled analysis is necessary for an exact design and construction. The consideration of the overstretched ground condition is also required because they are usually located at the great depth unlike the usual tunnels. Many researches have been performed on the estimation of relaxed rock mass height. However, there have been no researches on the estimation of relaxed rock mass height under overstretched ground conditions. In this study, therefore, hydro-mechanical coupled analyses were performed under the overstressed ground conditions and the relaxed rock mass heights were estimated based on the contour of the local safety factor around a tunnel.

  • PDF

On desirable conditions for a random number used in the random sampling method

  • Harada, Hiroshi;Kashiwagi, Hiroshi;Takada, Tadashi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.1295-1299
    • /
    • 1990
  • A new method called random sampling method has been proposed for generation of binary random sequences. In this paper, a new concept, called merit factor Fn, is proposed for evaluating the randomness of the binary random sequences generated by the random sampling method. Using this merit factor Fn, some desirable conditions are investigated for uniform random numbers used in the random sampling method.

  • PDF

Changes of Tissue Factor Activity on Inflammatory Stimulus and Aging in Rat

  • Han, Yong-Nam;Rhee, In-Kyung
    • Archives of Pharmacal Research
    • /
    • 제21권5호
    • /
    • pp.549-554
    • /
    • 1998
  • Tissue factor (TF), a principal initiator of the veertebrate coagulation cascade, is expressed in organ tissues, cells and blood. TF is konwn to be induced in endothelial cells, monocytes and macrophages by inflammatory stimuli and in many pathologic conditions. By using the modified method for in vido TF activity assay, we found that turpentine oil injection as an inflamatory stimulus also induced the TF activity in lung and brain tissues of rats. And the age-related increase in Tf activity was observed in healthy rat brain tissue.

  • PDF

Neural Stem Cell Differentiation Using Microfluidic Device-Generated Growth Factor Gradient

  • Kim, Ji Hyeon;Sim, Jiyeon;Kim, Hyun-Jung
    • Biomolecules & Therapeutics
    • /
    • 제26권4호
    • /
    • pp.380-388
    • /
    • 2018
  • Neural stem cells (NSCs) have the ability to self-renew and differentiate into multiple nervous system cell types. During embryonic development, the concentrations of soluble biological molecules have a critical role in controlling cell proliferation, migration, differentiation and apoptosis. In an effort to find optimal culture conditions for the generation of desired cell types in vitro, we used a microfluidic chip-generated growth factor gradient system. In the current study, NSCs in the microfluidic device remained healthy during the entire period of cell culture, and proliferated and differentiated in response to the concentration gradient of growth factors (epithermal growth factor and basic fibroblast growth factor). We also showed that overexpression of ASCL1 in NSCs increased neuronal differentiation depending on the concentration gradient of growth factors generated in the microfluidic gradient chip. The microfluidic system allowed us to study concentration-dependent effects of growth factors within a single device, while a traditional system requires multiple independent cultures using fixed growth factor concentrations. Our study suggests that the microfluidic gradient-generating chip is a powerful tool for determining the optimal culture conditions.

SHARP CONDITIONS FOR THE EXISTENCE OF AN EVEN [a, b]-FACTOR IN A GRAPH

  • Cho, Eun-Kyung;Hyun, Jong Yoon;O, Suil;Park, Jeong Rye
    • 대한수학회보
    • /
    • 제58권1호
    • /
    • pp.31-46
    • /
    • 2021
  • Let a and b be positive integers, and let V (G), ��(G), and ��2(G) be the vertex set of a graph G, the minimum degree of G, and the minimum degree sum of two non-adjacent vertices in V (G), respectively. An even [a, b]-factor of a graph G is a spanning subgraph H such that for every vertex v ∈ V (G), dH(v) is even and a ≤ dH(v) ≤ b, where dH(v) is the degree of v in H. Matsuda conjectured that if G is an n-vertex 2-edge-connected graph such that $n{\geq}2a+b+{\frac{a^2-3a}{b}}-2$, ��(G) ≥ a, and ${\sigma}_2(G){\geq}{\frac{2an}{a+b}}$, then G has an even [a, b]-factor. In this paper, we provide counterexamples, which are highly connected. Furthermore, we give sharp sufficient conditions for a graph to have an even [a, b]-factor. For even an, we conjecture a lower bound for the largest eigenvalue in an n-vertex graph to have an [a, b]-factor.

PEMS를 이용한 농업용 트랙터의 배기가스 배출계수 평가 (Evaluation of exhaust emissions factor of agricultural tractors using portable emission measurement system (PEMS))

  • 김완수;이시언;백승민;백승윤;전현호;김택진;임류갑;최장영;김용주
    • 드라이브 ㆍ 컨트롤
    • /
    • 제20권3호
    • /
    • pp.15-24
    • /
    • 2023
  • The aim of this study was to measure and evaluate the exhaust emission factors of agricultural tractors. Engine characteristics and three exhaust emissions (CO, NOx, PM) were collected under actual agricultural operating conditions. Experiments were performed on idling, driving, plow tillage, and rotary tillage. The load factor (LF) was calculated using the collected engine data, and the emission factor was analyzed using the LF and exhaust emissions. The engine characteristics and exhaust emissions were significantly different for each working condition, and in particular, the LF was significantly different from the currently applied 0.48 LF. The data distribution of exhaust emissions was different depending on the engine speed. In some conditions, the emission factor was higher than the exhaust emission standards. However, since most emission limit standards are values calculated using an engine dynamometer, even if the emission factor measured under actual working conditions is higher, it cannot be regarded as wrong. It is expected that the results of this study can be used for the inventory construction of a calculation for domestic agricultural machinery emissions in the future.

2차원 불연속체 해석에 의한 양호한 암반 내의 지하공동 형상비가 안정성에 미치는 영향 검토 (The effect of the shape factor of an underground cavern in good rock conditions on its stability by 2D discontinuum analysis)

  • 유광호;정지성
    • 한국터널지하공간학회 논문집
    • /
    • 제11권2호
    • /
    • pp.189-198
    • /
    • 2009
  • 현재 국내 외에서는 유류 지하 비축 공동, 식품 저장 공동 등과 같은 지하구조물 건설에 대한 관심이 증가하고 있다. 이러한 지하공동의 안정성을 평가할 때 형상비나 굴착면적을 비롯하여 지하공동이 굴착될 암반의 절리 발달 상태는 매우 중요하다. 따라서 본 연구는 형상비가 지하공동의 안정성에 미치는 영향을 안전율 중심으로 분석하였다 이를 위해 양호한 암반 내에 시공되는 공동의 네 가지의 형상비를 가정하고, 토피고, 측압계수, 절리의 간격, 강도 및 방향을 달리하여 민감도 분석을 실시하였다. 공동의 안정성은 강도감소기법을 이용하여 수치해석에 의해 얻은 안전율을 사용하여 평가되었다. 본 논문은 향후 불연속면을 포함한 암반에 시공되는 지하공동 설계 및 안정성 평가에 도웅이 될 수 있을 것으로 기대된다.