• Title/Summary/Keyword: facility safety management

Search Result 706, Processing Time 0.035 seconds

Study on the Life Cycle Management System of the Marine Transmission Tower Structures (해상철탑구조물의 수명관리방안 연구)

  • Pang, Gi-Sung;Song, Young-Chul;Yoon, Deok-Joong;Kim, Do-Gyeum
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.281-284
    • /
    • 2006
  • The marine Transmission tower infrastructure erected in the SI-HWA lake is deteriorated and damaged by the various environment effect, and then, there is a possibility of going bad in the safety. The appropriate maintenance to ensure the security of the structure during life cycle is necessary. Specially the Jacket or the steel file foundation in the sea is apt to be corroded quickly. In this research, to establish life management system of 345kV Yonghung marine transmission tower structure, the actual durability research facility which can obtain the actual proof data is constructed. the maintenance guideline and procedure of the structure are established. Hereafter, there is a plan which will advance the research against the composition of the life prediction model, which is based on the data acquired from the actual durability research facility.

  • PDF

The Study on the Korean Life Change Unit Model for Industrial Accident Prevention (산업재해방지를 위한 한국형 생활변화단위 모형에 관한 연구)

  • Kang Young-Sig;Yang Sung-Hwan
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2006.04a
    • /
    • pp.1-8
    • /
    • 2006
  • By the effect of globalism and information the workplace environment is complicated and diversified little by little. The job stress due to the life style, the idea and culture, and the automated facility system etc. is to a tendency which compared to increase more. It will not be able to prevent a industrial accident basically because the oriental and western life style is different. Therefore this paper presents the Korean life change unit model through statistical testing in order to minimize industrial accident with the proposed life change unit factors on the workers living In the middle area. Finally, the analytical result of this paper can be easily used in order to minimize the industrial accidents by the job stress with the worker and the occupational safety & health manager in real fields.

  • PDF

A Study on Engineering Design IT Installation of Thermal Relief Valve in a Chemical Plant (화학플랜트에서의 릴리프밸브 설계에 관한 고찰)

  • Char, Soon-Chul;Hwang, Soon-Yong;Jang, Seo-Il
    • Journal of the Korea Safety Management & Science
    • /
    • v.8 no.4
    • /
    • pp.39-51
    • /
    • 2006
  • Based on the practical process engineering design and commissioning and startup operation experiences focused on chemical process safety, the comprehensive review of engineering design and installation of the thermal relief valve with its surrounding facility in a chemical plant piping system is provided to enhance the better understanding of the piping system of characteristics of thermal relief valve which is comprised of the theoretical approach, correlation in terms of temperature and pressure increase caused by external heat supply in a piping system, consideration of thermal relief valve engineering design, pressure relieving system of serial thermal relief valves and exception of their installation. It is earnestly suggested that following topic should be implemented during thermal relief valve engineering design, installation and normal operation as well.

A Study on Developing Model for Regional Disaster Capability Assessment (지역방재성능평가를 위한 수리모형 연구)

  • Ki, Jae-Sug
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.1
    • /
    • pp.1-9
    • /
    • 2011
  • It is a significant issue for several country including Korea, where the natural and the weather conditions are severe, to keep the safety against disasters which occur frequently every year, especially in urban region crowded with population. In order to implement suitable and effective measures against various disasters in such area, development of method for evaluation of disaster prevention performance based on various disaster risks and effective disaster damage mitigation technologies is independable. In this paper, methods for hazard evaluation, vulnerability evaluation and loss evaluation, and damage technologies are proposed targetting man-made disaster and natural one like flood, earthquake and tsunami and so on. The method proposed in this paper is based on the research of USA and Japan for man-made disaster and natural disaster. The proposed method will be developed in detail in four years during research period funded by government.

A Basic Study on the Safety Management and Quantification of Vulnerability Factors in Small-size Old Buildings (소규모 노후 건축물 안전관리 및 취약성 요소 정량화 기본연구)

  • Goh, Wolsan;Oh, Gyuho;Ahn, Sungjin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.249-250
    • /
    • 2023
  • The vulnerability factor analysis and risk quantification model for aging buildings presented in this study can be utilized by governmental agencies such as the Facility Safety Foundation, the Ministry of Land, Infrastructure and Transport, and various local governments. Policymakers can use this to supplement inadequacies in existing checklists, and it is expected that they can proactively prevent risks by evaluating dangers based on specific aging characteristics of buildings.

  • PDF

Suitability valuation of Underground Facility Construction Using GIS (GIS를 활용한 지하시설물 시공의 적정성 평가)

  • 김감래;이재기;임건혁
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.04a
    • /
    • pp.465-469
    • /
    • 2004
  • The purpose of this study is to evaluate suitability of Underground Facility Construction in great land development area. Because there are the construct of national integration information control system and the advance of information technique, the necessity that construct the UIS to manage the urban space systematically is enlarged. In the purpose that we prepare the base of underground facility management system by driving the step digitalizing facilities buried underground and protect urban safety accident, we introduce the GIS in land development area. This study proposes the improvement direction by examining the outcome through the driving method and the outcome analysis.

  • PDF

Hydrogen Behavior at a Subcomparment in The Containment Building

  • Lee, U.J.;Park, G.C.
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.10a
    • /
    • pp.495-500
    • /
    • 1997
  • For hydrogen management in severe accidents with degraded nuclear core of PWR's, several experiments have been performed in the SNU hydrogen mixing facility. The objectives are understanding the extent of hydrogen mixing and analyzing the effects of factors which dominate uniform or non-uniform mixing at compartments in the containment building. The facility represents on a 1/11th linearly scaled model of the YGN unit 3&4, hydrogen was simulated by helium. Because there are the gaps between safety injection tank and compartment layers in the containment, the test facility was constructed in three dimentinal mode for analyzing of mixture behavior through the gaps. From the experimental results we could conclude that overall hydrogen concentration distributed uniformly in the free volume of the test compartment, but fluctuated in the gaps. This paper is focused on experimental result from several experiment.

  • PDF

Development of Decision Making Model of Measures on the Decrease of Traffic Accident Following Implementation of Intra-city Bus by using AHP (AHP 기법을 이용한 시내버스 교통사고 저감대책 의사결정 모델개발)

  • Choi, Jae Won;Jung, Hun Young;Jang, Seok Yong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.5D
    • /
    • pp.679-687
    • /
    • 2011
  • Implementation of semi-public management system of intra-city bus achieve excellent results but there are some side effects like increase of the fatal traffic accidents. This study tries to develop decision making model of measures of reducing traffic accidents following implementation of semi-public management system of intra-city bus. And survey with traffic experts and analytic hierarchy process are used for data survey and analysis. Quantitative measures and qualitative measures are suggested as high assessment items of AHP. Quantitative measures of low assessment items composed of a raise in the number of bus and safety device installation, facility supplement of bus stop, supplement of pedestrian protection facility, traffic safety assessment and supplement. Qualitative measures composed of system organization, redesign bus route, reinforcement of education, campaign and enforcement. The results of this study are as follows. First, the result turns out more weights are calculated on quantitative measures than on qualitative measures. Second, It is turned out in order of facility supplement of bus stop and traffic safety assessment and supplement as the quantitative measures. Third, as qualitative measures, system organization and redesign bus route are in the order. The results of this study are considered to be a basic data which can be referred if measures on the decrease of traffic accident are established and implemented in other cities and provinces.

A Development of Criteria for Evaluating School Zone by Utilizing Analytic Network Process (네트워크분석법(ANP)을 이용한 어린이보호구역 평가항목 개발)

  • Jeong, Kwang Seop;Kim, Tae Ho;Park, Je Jin;Won, Jai Mu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.2D
    • /
    • pp.191-197
    • /
    • 2009
  • This study choose the Criteria by conducting survey questionnaire of expertise, ANP analysis, and reviewing literature to samples of School Zone in a synthetic and reasonable way. It draws the estimating factors including a variety of existing aspects (user, facility, operation and management, and education and institution) from the analyses and applies ANP to reflect the decision making process. The results show as follows: first, first level of weights presents proportion of 'facility' and 'user' takes 65% of total weights. It implies that the facility protects children from obstacles is the top priority of the settings. second, the second level of weights present similar importance with the first level. Facility management, road to school, surroundings, safety facility, decelerating facility hold approximately 72% of overall levels. This indicates that improving and repairing surroundings, and safety and decelerating facility are the first priority to consider. These estimating indicators will be properly utilized to rationally appoint prevention zone with reflecting various factors and social class.

A study on location selection of total circulation complex using fuzzy theory (퍼지이론을 이용한 종합유통단지 입지 선정에 관한 연구)

  • Oh, Sun-Il;Yoon, Ho-Bin;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.1
    • /
    • pp.91-105
    • /
    • 2008
  • Nowadays, circulation industry is taking charge of important role in improvement of competitive power on the manufacturing industry and public welfare increase of consumer, price stabilization, employment creation and so on. A lot of research have been progressing for formation of total circulation complex, but decision making for selection of location on some facility is only calculated the optimum value when correct data values are inserted. However, a lot of decision making is accomplished in situation that have little knowledge of objective and constraints and as real world is also evaluated inclusive of analyst's subjectivity about variable, indefinite and fuzzy part, so it is decreasing a reliability on evaluation result and complicating objective evaluation on various effect and negative impact. Accordingly, from under like this situation, this study is to develop location decision model of circulation complex using fuzzy theory from the intention for the most reasonable decision making in fuzzy situation based on decision making problem on conventional location and size decision that did to be satisfactory constraints necessarily.