• 제목/요약/키워드: extra water

검색결과 160건 처리시간 0.023초

기간별 저수 관리를 통한 소규모 댐의 밭 관개용수 확보 (Securement of Upland Irrigation Water in Small Dams through Periodical Management of Storage Level)

  • 김선주;이주용;김필식
    • 한국농공학회논문집
    • /
    • 제47권2호
    • /
    • pp.3-12
    • /
    • 2005
  • The objective of this study is securement of upland irrigation water using storage level management of small dams. However, it is not new development of water resources but securement of water using storage level management of existing dam. This study has enhanced the water utilization coefficient of dam, after extra available water had been calculated by application of periodical management storage level and this water is used to other water like the upland irrigation water demand. As the result of application, it can secure extra available water except the water requirement. Minimum extra available water except flood is about $20,000,000\;m^3$ and crop irrigation water demand of 10yr frequency is about $2,033,000\;m^3$ in Seongju. The utilization of crop irrigation water can be possible. And extra available water is about $3,102,000\;m^3$ in 2000, $1,959,000\;m^3$ in 2001 except flood period and crop irrigation water demand of 10yr frequency is about $2,272,000\;m^3$ in Donghwa. It is judged that extra available water cannot be used to crop irrigation water during the dry season in Dongwha. Consequently, when management storage level is determined and more efficient use of water is gotten like this study, water utilization coefficient will be enhanced.

관개용 댐의 효율적 저수관리를 통한 밭 관개 용수 확보 (Security of Upland Irrigation Water through the Effective Storage Management of Irrigation Dams)

  • 이주용;김선주;김필식
    • 한국농공학회논문집
    • /
    • 제48권2호
    • /
    • pp.13-23
    • /
    • 2006
  • In Korea, upland irrigation generally depends on the ground water or natural rainfall since irrigation water supplied from dams is mainly used for paddy irrigation, and only limited amount of irrigation water is supplied to the upland area. For the stable security of upland irrigation water, storage level of irrigation dams was simulated by the periods. A year was divided into 4 periods considering the irrigation characteristics. Through the periodical management of storage level, water utilization efficiency in irrigation dams could be enhanced and it makes available to secure extra available water from existing dams without new development of water resources. Two study areas, Seongju and Donghwa dam, were selected for this study. Runoff from the watersheds was simulated by the modified tank model and the irrigation water to upland crops was calculated by the Penman-Monteith method. The analyzed results showed that relatively sufficient extra available water could be secured for the main upland crops in Seongju area. In case of Donghwa area, water supply to non-irrigated upland was possible in normal years but extra water was necessary in drought years such as 1998 and 2001.

레미콘 단위수량 산포가 콘크리트 강도 및 내구성에 미치는 영향 (An Influence of Unit-Water Content Distribution in Ready-Mixed Concrete on Strength and Durability of Concrete)

  • 우영제;이한승;정상화
    • 콘크리트학회논문집
    • /
    • 제20권3호
    • /
    • pp.375-381
    • /
    • 2008
  • 레미콘 제조오차에 의한 콘크리트내의 물의 수량이 증가하면 내구성저하 등의 다양한 문제점을 야기하게 된다. 이러한 이유로 여러 방법들 중에 단위수량의 신속측정법인 정전용량법, 고주파가열법, 단위용적질량법을 이용하여 단위수량의 변동을 관리하고 있으며, 특히 일본의 경우에는 단위수량 변동 ($\pm$ 10, 15, 20 kg/$m^3$ 등)에 대한 관리지침을 규정하여 관리하고 있다. 그러나 일본에서 규정하고 있는 각종 지침들이 내구성 저하도를 고려하지 않은 상태에서 제조오차와 측정오차를 확률적으로 고려한 불확도 개념에서 합부판정 기준을 정하고 있는 실정이다. 이에 본 논문에서는 불확도 개념뿐만 아니라 실제 수량 산포에 따라 내구성 저하에 미치는 영향을 검토하고자 수량을 추가로 첨가하여 동결융해, 중성화, 염해를 중심으로 내구성 저하도를 측정하였다. 이상의 실험 결과 일반강도 범위 내에서 15 kg/$m^3$ 이상의 수량이 추가로 첨가 되었을 경우 콘크리트의 성능 저하 효과가 크기 때문에 설계된 내구 성능의 적정 수준 이상을 유지하기 위해서는 배합 설계된 단위수량에 대한 품질관리에 유의할 필요가 있다.

배합수량 변동에 따른 콘크리트의 경화성상 및 내구성에 관한 연구 (A Study on Hardened Properties and Durability of Concrete according to Unit-Water Content)

  • 구경모;임창혁;이의배;김영선;김영선;김규용
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 춘계 학술논문 발표대회 학계
    • /
    • pp.45-48
    • /
    • 2009
  • The performance of concrete mainly depend upon its water-cement ratio. If water percentage is excess in concrete, it may cause the degradation of performance. Because of these reasons, the change of water content is managed by using various evaluation method of unit water content. And criterion for the change of water content is regulated and used. However the criterion is set only considering production error and measurement error but criterion does not consider performance degradation of concrete. Therefore this study tries to investigate degradation of performance while adding extra water by artificial manipulation or management error in concrete, The contents of extra water for tests are set as 0, 20, 40, 60kg/m3, to examine the performance degradation of concrete, strength, shrinkage, cracks, carbonation are tested This study conclude that, when extra water content is excess than 20kg/m3 in concrete, then performance level of concrete declined rapidly. 80 it is very important to maintain quality of concrete for its better performance.

  • PDF

끈상여재를 이용한 Trickling Filter 반응조에서의 EPS 반응특성 (Characteristics of water quality and extra-cellular polymeric substances in trickling filter system using plastic fiber media)

  • 독고석
    • 상하수도학회지
    • /
    • 제22권1호
    • /
    • pp.169-174
    • /
    • 2008
  • In this study a trickling filter system was developed by using polypropylene media and polypropylene nylon media that has recently been developed. The experiment analyzed an ability of water purification of the two plastic media and the effects of biomass on the final effluent. As recycling ratio increases, polypropylene nylon suspender showed higher efficiency by 20%; and, when media height was lengthened twice, efficiency increased about 10%. EPS and biomass increased in proportion to the increase of recycling ratio, and bound-TOC showed a similar trend with bound-EPS (extra-cellular polymeric substances) concentration.

유로폼에 대한 투수거푸집의 적용 특성 (Application properties of dewatering form system using the Euro-form)

  • 이종석;안기홍;김도겸;안상구;민진홍;홍학표
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.601-604
    • /
    • 2008
  • 콘크리트 타설시 시멘트의 수화에 필요한 수량은 결합수와 겔수를 포함하여 물-시멘트비 30% 이하가 된다고 알려져 있다. 그러나, 이러한 최소의 수량만으로는 작업성이 현저히 떨어지기 때문에 물-시멘트비를 일정부분 높여서 사용하여야 한다. 따라서 굳지않은 콘크리트에는 항상 10${\sim}$20%의 잉여수가 발생하게 된다. 이러한 잉여수는 콘크리트 내부에서 갇힌공기로 남게 되어 구조물의 수밀성, 투기성 및 강도 등 여러 가지 내구성을 저하시키는 요인이 되어 궁극적으로 구조물의 수명을 단축시키게 되므로, 잉여수를 제거할 수 있다면 구조물의 내구성 향상에 큰 도움이 될 것이다. 따라서, 본 논문에서는 타설된 굳지않은 콘크리트의 표면부 피복콘크리트의 잉여수를 제거하기 위한 투수 거푸집 시스템 개발을 위해 유로폼 투수거푸집에 대한 적용 실험을 통하여 기초적인 특성을 파악하였다. 유로폼 투수거푸집을 적용한 경우 일반 유로폼에 비해 약 16%의 강도증가율을 보였으나, 상단부로 갈수록 강도증가율은 낮게 나타났다. 초음파속도와 표면거칠기의 측면에서도 투수거푸집이 더욱 양호한 결과를 보였다.

  • PDF

고점도 글라스아이오노머의 불소 유리량, 미세경도 및 용해도의 상관관계 (Correlation between Fluoride Release, Microhardness and Solubility of High viscosity Glass Ionomers)

  • 신비솔;김종수;유승훈
    • 대한소아치과학회지
    • /
    • 제45권4호
    • /
    • pp.418-425
    • /
    • 2018
  • 이 연구의 목적은 고점도 글라스아이오노머와 레진 강화형 글라스아이오노머의 시간에 따른 불소 유리량, 미세경도, 용해도를 측정하고 비교하는 것이다. 고점도 글라스아이오노머인 Fuji IX GP EXTRA, Fuji IX GP, 레진 강화형 글라스아이오노머인 Fuji II LC를 실험군으로, Filtek$^{TM}$ Z350XT을 대조군으로 설정하였으며 탈이온수에 보관한 후 84일간 불소 유리량, 미세경도, 용해도를 측정하였다. 불소 유리량의 측정 결과 모든 글라스아이오노머는 1일에 불소 유리량이 가장 높았으며 서서히 감소하였다. 불소 유리량과 누적량은 Fuji IX GP EXTRA가 가장 높았으며 Fuji IX GP와 Fuji II LC는 유의한 차이를 보이지 않았다. 미세경도 측정 결과 모든 실험군에서 수분 노출 1일 후 측정에서 미세경도의 감소를 보였으며 84일 후 미세경도는 Fuji IX GP EXTRA와 Fuji IX GP가 유의한 차이를 보이지 않았고 Fuji II LC이 가장 낮았다. 용해도 측정에서 Fuji IX GP EXTRA, Fuji IX GP, Fuji II LC은 21일까지 급격히 증가하였으며 21일 이후에는 세 군이 유의한 차이를 보이지 않았다. 결과적으로 단기간의 불소 유리는 용해도와 미세경도에 영향을 미치지만 장기간의 불소 유리는 물성과 상관관계를 가지지 않았다. 이 연구를 통하여 여러 가지 글라스아이오노머의 불소 유리량, 미세경도, 용해도를 평가하였으며 이러한 특성을 임상적으로 적용 할 수 있을 것이다.

초경석고와 메타카올린 혼합재료의 물성실험 및 적용 (Physical Properties Testing and Practical Applications of Restoration Materials Made with Extra Hard Stone and Metakaolin)

  • 김현숙;이해순
    • 박물관보존과학
    • /
    • 제17권
    • /
    • pp.101-116
    • /
    • 2016
  • 기존의 석고복원재로 복원한 문화재는 대기 중의 수분을 반복하여 흡·방출하면서 물성이 약화되어 형태가 변형되고 채색층 박락이 진행된다. 본 논문에서는 이러한 단점을 보완하기 위해 일반석고보다 더 강한 초경석고를 실험대상으로 두었으며 메타카올린(Metakaolin)을 혼합하여 도자기 복원재료로 적합하도록 물성을 개선하였다. 초경석고와 메타카올린 혼합재료의 압축강도(119MPa)는 일반석고(26MPa)보다 월등히 높았으며, 마모율(0.88%)은 일반석고의 마모율 2.53% 보다 낮게, 흡수율(2.9%)은 일반석고(17.2%) 보다 약 5배 낮게 측정되었다. 특히, 주사전자현미경 관찰결과 혼합재료의 경화치밀도가 단미의 초경석고보다 높았다. 즉, 메타카올린을 첨가함으로써 초경석고의 강도와 수분저항성을 높이고 표면을 치밀하게 하여 도자기 복원재료로서 적합하게 물성을 개선시켰다. 그리고 이 혼합재료를 실재 문화재인 토제수반(신안18892), 분청사기조화문병(접수2034), 분청사기 국문내인화문대접(접수1730)의 결손부 복원에 적용해봄으로써, 혼합재료가 주입 및 적층성형에 유리하고 경화표면이 균질하여 자연스러운 채색이 가능한 재료임을 확인하였다.

팔당댐 상류의 수질예보시스템 개발에 관한 연구 (A Study on the Development of Water Quality Forecasting System in Upstream of Paldangdam)

  • 최남정;서일원;김영한;이명은
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2007년도 학술발표회 논문집
    • /
    • pp.1387-1391
    • /
    • 2007
  • In this study, water quality prediction that is necessary to water quality forecasting system is performed using 2-D river analysis models RMA-2 and RAM4. RAM4 is suitable to water quality forecasting system cause it is possible to put in the pollutants as a mass type boundary condition. Instant injections of pollutants at Yongdamdaegyo Bridge in Namhangang River are simulated and the behavior of pollutant cloud is observed. The effects of water quality accident to Paldang 2 water intake plants in Paldangho Lake is analyzed with time variation. And extra flow simulation is performed for mitigation of pollution. Several cases of water quality forecasting system at home and abroad are investigated and the direction of water quality forecasting system is presented.

  • PDF

투수성 아스팔트 포장에 대한 우려와 실제: 구조적 적합성, 홍수 완화 그리고 비점오염 저감 (Worries and Reality Regarding Porous Asphalt Pavements: Structural Integrity, Flood Mitigation and Non-Point Pollution Reduction)

  • 유인균;이수형;한대석;이상혁
    • Ecology and Resilient Infrastructure
    • /
    • 제3권4호
    • /
    • pp.272-278
    • /
    • 2016
  • 투수성 포장은 도시에서 불투수면 증가에 따라 발생하는 환경문제에 대응하기 위한 대표적인 저영향개발 (Low-Impact Development, LID) 기법의 하나이다. 도시의 도로가 투수성 포장으로 바뀐다면 도시의 불투수면이 약 절반으로 줄어들고, 더 나가 지붕으로부터의 강수 유출까지 수용할 수 있다면 도로는 도시 물 순환 문제의 원인자에서 해결자로 전환될 수 있다. 그러나 국내에서는 경험과 인식의 부족으로 투수성 포장을 적용하는 경우가 거의 없는 실정이다. 도로 포장을 설계, 시공 및 관리하는 도로 기술자는 전통적으로 포장 구조에 물이 들어가는 것을 피하려 하고, 수자원 전문가는 투수성 포장의 도시홍수 저감효과에 대해서 의문을 가진다. 본 연구에서는 국내외의 다양한 연구 결과를 검토하여 투수성 포장에 대한 역사와 최신 기술을 분석하였다. 최신의 투수성 포장 기술을 요약하면 다음과 같다. 첫째, 투수성 포장은 기존의 방법대로 설계해도 노상 약화와 동결 융해로 인한 구조적인 문제가 없다. 둘째, 투수성 포장의 저수층 두께의 조절로 도시수문 설계에 직접 반영할 수 있다. 셋째, 기존의 다른 비점오염 처리시설에 비하여 수질처리 효과가 떨어지지 않는다. 특히 투수성 포장은 겨울철 제설제 사용을 저감하여 보다 친환경적이다.