Browse > Article
http://dx.doi.org/10.4334/JKCI.2008.20.3.375

An Influence of Unit-Water Content Distribution in Ready-Mixed Concrete on Strength and Durability of Concrete  

Woo, Young-Je (Construction Material Research Center, Korea Institute of Construction Materials)
Lee, Han-Seung (School of Architecture & Architectural Engineering, Hanyang University)
Jung, Sang-Hwa (Construction Material Research Center, Korea Institute of Construction Materials)
Publication Information
Journal of the Korea Concrete Institute / v.20, no.3, 2008 , pp. 375-381 More about this Journal
Abstract
Various problems such as durability degradation may happen when extra water is added to concrete. Because of these reasons, the change of water content is managed by using rapid evaluation method of unit water content such as electric capacity method, heat drying method making use of micro wave, unit capacity mass method among various methods. Especially, in Japan, guidance for the change of water content ($\pm$ 10, 15, 20 kg/$m^3$ etc.) were regulated and used. However, it is the real situation that the guidance which were regulated in South Korea evaluate suitability only considering production and measurement error under the circumstances which are not considering the degree of durability degradation. Therefore, this study tries to investigate the influence of addition of extra water in the concrete on the durability degradation of concrete when it was added by artificial manipulation or by management error. From the test results, a guideline of the contents of extra water for the quality control is suggested with the consideration of the degree of durability degradation and the probable error resulted from the addition of extra water. The contents of extra water for tests are set as 0, 15, 25, 35 kg/$m^3$. To examine the durability degradation of concrete, freezing and thawing, carbonation, chloride penetration and compressive strength are tested.
Keywords
extra water; unit water content; durability; freezing and thawing; chloride penetration;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 日本建築學會, 材料施工委員會 コンクリ一ト試驗法小委員會, コンクリ一トの試驗方法にするシンポジウム報告集, 2003. 11
2 日本コンクリ一ト工學協會, フレッシュコンクリ一トの單位水量迅速測定及び管理システム調査硏究委員會報告書, 2004. 6
3 Comite Euro-International du Beton, "CEB-FIP Model Code 1990," Bulletin d'Information, Nos. 195 and 196, Lausanne, 1990
4 日本國土交通省, レディミクストコンクリ一ト單位水量測定要領(案), 2004. 3, pp. 1-3
5 Tang, L. and Nilsson, L. O., "Rapid Determination of the Chloride Diffusivity in Concrete by Applying an Electrical Field," ACI Materials Journal, Jan.-Feb., 1992, pp. 49-53
6 ASTM C 1079-87, Standard Test Methods for Determining the Water Content of Freshly Mixed Concrete, ASTM
7 日本コンクリ一ト工學協會, フレッシュコンクリ一トの單位水量迅速測定及び管理システム調査硏究委員會報告書, 2004. 6, pp. 1-59
8 김용로, 정양희, 굳지 않은 콘크리트의 단위수량 측정 기술 현황 및 적용성 검토, 대림기술정보 2005년 가을호, 2005, pp. 43-54
9 友 史紀 ほか, 高周波加熱裝置を用いたフレッシュコンクリ一トの單位水量簡易迅速試驗法の開發, 日本建築學會構造系論文報告集, 第400, 1989. 6, pp. 1-7
10 豊福俊秦, "フレッシュコンクリ一トの位水量の早期迅速試法にする究," 日本コンクリト工學年次論文集, Vol. 11, No. 1, 1989
11 小林 茂敏, "フレッシュコンクリ一トの位水量迅速判定法にする的討," 日本コンクリト工學年次論文集, Vol. 12, No. 1, 1990
12 丸嶋紀夫 ほか, "水中質量法によるフレッシュコンクリ一トの位水量試方法の究," 日本建築學會學術講演梗槪集, 1997. 9, pp. 619-620
13 우영제, 류화성, 정상화, 권기준, "콘크리트 내 수량증감에 의한 내구 품질 변동에 관한 연구," 한국방재학회논문집, 7권, 2호, 2007. 6, pp. 1-6   과학기술학회마을
14 Miguel Angel Sanjun and Csar del Olmo, "Carbonation Resistance of One Industrial Mortar Used as a Concrete Coating," Building and Environment, Vol. 36, 2001, pp. 949-953   DOI   ScienceOn
15 長井 義 ほか, "濃度差法によるフレッシュコンクリ一ト中の位水量測定にする," 日本建築學會年次大會梗槪集, 2003. 9, pp. 613-614
16 江守 秀次, "フレッシュコンクリ一トの位水量迅速推定法 にする究," 日本コンクリ一ト工學年次論文集, Vol. 19, No. 1, 1997
17 小林 茂敏, "フレッシュコンクリ一トの位水量迅速判定法にする的討", 日本コンクリ一ト工學年次論文集, Vol. 12, No. 1, 1990
18 日本國土交通省, レディミクストコンクリ一ト單位水量測定要領(案), 2004. 3
19 杉山雅 ほか, "フレッシュコンクリ一トの位水量の各種測定方法にする比較," 日本建築學會年次大會梗槪集, 2004. 9, pp. 591-592
20 田村 博 ほか, "RI水分計を用いたポンプ配管中のコンクリ一トの水量連續モニタリング," 日本コンクリト工學年次論文報告集, Vol. 20, No. 1, 1998, pp. 125-130