• Title/Summary/Keyword: exposure control system

Search Result 490, Processing Time 0.037 seconds

Evaluation of Automatic Exposure Control Systems (X선자동노출(X線自動露出) 제어장치(制御裝置)에 관한 검토(檢討))

  • Kim, Chung-Min;Kim, Keon-Chung;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.14 no.1
    • /
    • pp.23-28
    • /
    • 1991
  • Automatic exposure control systems are now readily available and widly used in radiography. A device that automatically determines the amount of radiation required to produce an acceptable level of film blackness is called a phototimer, or automatic exposure control. There are limitations in the use of phototimers ; however, equipment can be used much more effectively if one recognize these limitations, and the goal of obtaining a properly exposed, reproducible radiography can be achieved. We have some results in this experimental study. The variations of film density due to kVp are in propotion to below 80 kVp range. But indicate constant level above 80 kVp to 120 kVp. The characteristic density variation by phantom thickness shows the higher the thiner in exit type. AEC system have a density control that is designed to make adjustments increase or decreas the density 10% per step or 25% per step. The automatic exposure control circuits must meet the several regulations of the HEW. Some forms of technique chart is recomened for use of AEC.

  • PDF

On Exposure of Workers in Sections Handling Organic Solvents within Hospitals to Benzene, Xylene, and Toluene (병원 내 근로자 중 유기용제를 취급하는 부서에서 벤젠, 크실렌, 톨루엔의 노출 여부에 관한 연구)

  • Oh, Dong-Sun;Park, Mi-Suk
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.40 no.2
    • /
    • pp.147-152
    • /
    • 2008
  • Due to the development and expansion of industries and medical standards, the number of workers who handle organic solvents within hospitals is increasing. The authors in this study intended to investigate the actual conditions of the handling of the solvents and to encourage the recognition that the exposure to such solvents may be possible because of insensitivity to safety. In order to investigate the actual conditions of exposure of workers within hospitals, the experimental group included the three sections (Pathology department, Central Supply Room, and Operating Room), which handle organic solvents most frequently. Meanwhile, university interns were selected to be the control group. This study was conducted between May 1 to May 30, 2007, and urine was taken as samples. Hippuric acid, mandelic acid, methylhippuric acid, and phenylglyoxylic acid were analyzed through gas chromatography, and a total of 52 subjects of the experimental and the control groups were performed of the analysis. As for the results of the analysis of the experimental group, the exposure to benzene was $42.27{\pm}3.70mg/g$ creatinine, that of xylene was $1.30{\pm}0.18g/g$ creatinine, and that of toluene was $2.36{\pm}0.24g/g$ creatinine. Meanwhile, the results of the analysis of the control group showed that the exposure to benzene was $15.54{\pm}2.85mg/g$ creatinine, that of xylene was $0.52{\pm}0.02g/g$ creatinine, and that of toluene was $0.85{\pm}0.20g/g$ creatinine. The amount of exposure to benzene, xylene, and toluene was shown to be under the maximum permitted level, but as for Pathology department, it was required to educate on working conditions, to educate workers on prevention management about their health, and to install fume hood and exhaust system to improve the environments.

  • PDF

A Study on the Evaluation of Deterioration Properties of Reinforced Concrete Applied Repair Material and Method System by Long Term Exposure Experiment (장기폭로실험에 의한 철근콘크리트 보수재료공법 시스템의 열화특성 평가에 관한 연구)

  • Choi, Hyeong-Gil;Shin, Kwan-Soo;Shin, Seung-Bong;Na, Chul-Sung;Kim, Gyu-Yong;Kim, Moo-Han
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.04a
    • /
    • pp.129-132
    • /
    • 2007
  • In this study, for the establishment of the performance evaluation methods of repair material and method for reinforced concrete structure and the quality control standards of durability recovery method, the quantitative exposure data by exposure experiment under the coastal and normal atmosphere environment is accumulated and analyzed. Investigating and evaluating the result of exposure experiment during 54 months of exposure age under the coastal and normal atmosphere environment, Micro crack, swelling and spatting of surface coating material, crack of repair boundary parts and the great potential difference between repair part and non-repair part were somewhat generated. And the result shown that exposure specimen of coastal environment had lower electrode potential than exposure specimen of normal atmosphere environment.

  • PDF

A Design of Improved Auto Exposure System for Digital Still Camera (개선된 디지털 카메라용 자동노출 시스템의 구현)

  • Lee, Sang-Yang;Cho, Sun-Ho;Park, Chong-Kug
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.110-112
    • /
    • 2005
  • In this paper, an improved AE (auto exposure) system for digital still camera is proposed. The AE system is the most important part in camera to get high quality picture image. However, there is no remarkable progress in this field until this time in spite of its importance. In recent, some researchers try to develop an AE system with signal processing technique. But it has some problems in exposure time and sometimes generates oscillation in brightness. Therefore, we develop a new system using a control technology to remove such phenomena. This new system shows about 30% improved performance than conventional one.

  • PDF

A Control Algorithm for Wafer Edge Exposure Process

  • Park, Hong-Lae;Joon Lyou
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.55.4-55
    • /
    • 2002
  • In the semiconductor fabrication, particle contamination is wide-spread and one of major causes to yield loss. Extensive testing has revealed that even careful handling of wafers during processing may cause photo-resist materials to flake off wafer edges. So, to remove the photo-resist at the outer 5mm of wafers, UV(Ultraviolet) rays are exposed. WEE (Wafer Edge Exposure) process station is the system that exposes the wafer edge as prespecified by controlling the positioning mechanism and maintaining the light intensity level In this work, WEE process station has been designed so as to significantly lower the amount of particle contamination which occurs even during the most r...

  • PDF

Organic Solvent Exposure of Thinner-Using Occupation and Its Treatment by Means of $TiO_2$ Photocatalyst (신너사용 작업장의 유기용제 노출 및 $TiO_2$ 광촉매를 이용한 BTX처리에 관한 연구)

  • 양원호;김현용;손부순;박종안
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.2
    • /
    • pp.26-33
    • /
    • 2002
  • Ultimate objective of industrial hygiene is the prevention of health impairment that may result from exposure to chemicals at workplace. Workers in solvent thinner-using occupation environment may be highly exposed to VOCs (volatile organic compounds) because solvent thinner has been used extensively such as painting, spraying, degreasing, coating and so on in Korea. The purpose of this study was to recognize, evaluate, and propose the control methods of VOCs from solvent thinner-using workplace. Five target volatile organic compounds (benzene, toluene, ethylbenzene, o-xylene, and m-xylene) were monitored in H company of Shiwa Industrial Complex and analyzed in perosnal, occupational indoor and outdoor during working hours simultaneously. Engineering control such as local ventilation should be made in considering the long-term exposure, though measured VOCs concentration did not exceed the workplace exposure standards. In addition, air cleaning device should be installed in local ventilation because Shiwa Industrial Complex has had the serious ambient air pollution. Currently, environmental purification using $TiO_2$ photocatalyst have attracted a great deal of attention with increasing number of recent environmental problems. In this study, $TiO_2$ sol coated on the ceramic bead was prepared by sol-gel method and the photodegradation of target compounds was investigated in gas phase by the exposure to UV-A lamp(365nm) in a batch system.

A Coordinated Ciphertext Policy Attribute-based PHR Access Control with User Accountability

  • Lin, Guofeng;You, Lirong;Hu, Bing;Hong, Hanshu;Sun, Zhixin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.4
    • /
    • pp.1832-1853
    • /
    • 2018
  • The personal health record (PHR) system is a promising application that provides precise information and customized services for health care. To flexibly protect sensitive data, attribute-based encryption has been widely applied for PHR access control. However, escrow, exposure and abuse of private keys still hinder its practical application in the PHR system. In this paper, we propose a coordinated ciphertext policy attribute-based access control with user accountability (CCP-ABAC-UA) for the PHR system. Its coordinated mechanism not only effectively prevents the escrow and exposure of private keys but also accurately detects whether key abuse is taking place and identifies the traitor. We claim that CCP-ABAC-UA is a user-side lightweight scheme. Especially for PHR receivers, no bilinear pairing computation is needed to access health records, so the practical mobile PHR system can be realized. By introducing a novel provably secure construction, we prove that it is secure against selectively chosen plaintext attacks. The analysis indicates that CCP-ABAC-UA achieves better performance in terms of security and user-side computational efficiency for a PHR system.

The Development of Robot Control System for Nuclear Facilities

  • Lee, Sung-Uk;Kim, Chang-Hoi;Jeong, Seong-Ho;Kim, Seung-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2696-2700
    • /
    • 2003
  • Nuclear robots should be developed for the reduction of radiation exposure, lower man hours, shorter power outage, and also improved worker safety concerns in performing hazardous and dangerous tasks. Among the components of a nuclear robot system, a robot control system equivalent to a human brain is a crucial point because a nuclear robot does not work without a control system. Therefore, in this paper, we will explain the requirements for a robot control system for a nuclear robot from a general point of view and also review the robot control systems of nuclear robots that were developed domestically, to assist a researcher beginning with the design for the control system of nuclear robots. The explained robot control system will be useful to develop the control system for industrial robots, home robots and other robots which are needed for tele-operation and are controlled through the internet.

  • PDF

An Investigation of the Noise in Ship Engine-Room and Cabins for Hearing Protection (I) (청력보호를 위한 선박 기관실 및 선실소음의 조사(I))

  • Yu, Y.H.
    • Journal of Power System Engineering
    • /
    • v.3 no.3
    • /
    • pp.97-103
    • /
    • 1999
  • As the noise of ship engine room is too loud, the engineer who works in a ship engine-room has the trouble of hearing. In this paper deals the investigation of the noise of ship engine room and cabins with the internationally allowable noise exposure level and noise exposure time. Recently, the problem of engine-room noise is more serious because of shipowner wants to make small number and larger size of cylinder. Therefore, engineers work in a ship engine-room for a long time have the trouble of hearing when they are exposed the high noise level. In this study, two kinds of vessels were used to investigate the noise of engine room, engine-control room, bridge, offices and cabins. As criteria of sound levels, A-weighted sound pressure level and octave band pressure level were used.

  • PDF