• Title/Summary/Keyword: experimental measurement

Search Result 5,385, Processing Time 0.038 seconds

Measurement of Flow Field in the Pebble Bed Type High Temperature Gas-cooled Reactor (페블 베드 타입 고온 가스 냉각 원자로 내부 유동장 측정)

  • Lee, Sa-Ya;Lee, Jae-Young
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2088-2093
    • /
    • 2008
  • In this study, flow field measurement of the Pebble Bed Reactor(PBR) for the High Temperature Gas-cooled Reactor(HTGR) was performed. Large number of pebbles in the core of PBR provides complicated flow channel. Due to the complicated geometries, numerical analysis has been intensively made rather than experimental observation. However, the justification of computational simulation by the experimental study is crucial to develop solid analysis of design method. In the present study, a wind tunnel installed with pebbles stacked was constructed and equipped with the Particle Image Velocimetry(PIV). We designed the system scaled up to realize the room temperature condition according to the similarity. The PIV observation gave us stagnation points, low speed region so that the suspected high temperature region can be identified. With the further supplementary experimental works, the present system may produce valuable data to justify the Computational Fluid Dynamics(CFD) simulation method.

  • PDF

Development of automatic measurement method of concentricity and roundness using image processing technique

  • Moon, Hyung-Wook;Huh, Kyung-Moo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.130.2-130
    • /
    • 2001
  • In this paper, we suggest an algorithm for the automatic measurement of concentricity and roundness using image processing technique. From the experimental results, we could find that the required measurement accuracy specification is sufficiently satisfied using our proposed method.

  • PDF

Automatic measurement of a Isolux diagram (등조도 곡선의 자동화 측정)

  • 권영혜;장우진
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1989.10a
    • /
    • pp.31-36
    • /
    • 1989
  • Low-cost and automated isolux diagram measurement system are investigated. The system is constructed with illuminance measurement array, analog multiplexer, A/D converter and 16-bit microcomputer. The experimental results show good agreement with the measured illuminance values. Decreasing the measure-spacing, the more accurate diagram can be obtained.

  • PDF

Design of Capacitive Displacement Sensor and Gap Measurement with High Precision Using Surface Acoustic Wave Device (표면 탄성파 장치를 응용한 용량 성 변위센서의 설계 및 초정밀 간극 측정)

  • Kim, Jae-Geun;Lee, Taek-Joo;Lim, Soo-Cheol;Park, No-Cheol;Park, Young-Pil;Park, Kyoung-Su
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.5
    • /
    • pp.437-443
    • /
    • 2010
  • SAW device is widely used as band pass filters, chemical or physical sensors, and actuators. In this paper, we propose the capacitive gap measurement system with high precision using SAW device. The research process is mainly composed of theoretical and experimental part. In the theoretical part, equivalent circuit model was used to predict the SAW response by the change of load impedance. In the experimental part, commercialized capacitor was used to see the SAW response by the change of load capacitance to check the feasibility as a sensor unit. After that, experimental setup to measure and adjust the gap was made and the SAW response by the change of gap which caused the capacitance change was measured. Finally, resolution and stroke was decided compared with the signal change and basic measurement noise level.

Design of the Power System Frequency Measurement Module for the Relay using the Digital Phase Locked-Loop (디지털 위상 고정 루프를 이용한 계전기용 정밀 주파수 측정 장치)

  • 윤영석;최일흥;이상윤;황동환;이상정;박장수
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.7
    • /
    • pp.365-374
    • /
    • 2004
  • The relay measures the frequency of the power system in order to detect faults and separate them from the system. Many estimation algorithms for the relay have been proposed to accurately measure the frequency. This paper proposes a new frequency measurement method using the digital phase locked-loop(DPLL) for the relay of the power system. The proposed method is configured with a DPLL scheme and verified through computer simulations and experimental tests. In order to cope with noises in the power system, filters are included in the input signal processing part and the frequency comparator. MATLAB is used for computer simulations and an experimental setup with a CPU and an FPGA(Field Programmable Gate Array) is constructed. The loop filter of the DPLL is run in the CPU software In adjust parameters and others are in the FPGA. Experimental tests are performed lot a function generator and the power system. Results show that the proposed method is appropriate to the frequency measurement for the relay.

A Study on the Influence of Wearing-Girdle on the Various Physiological Function (Girdle 착용이 신체 제 기능에 미치는 영향에 관한 연구)

  • 박영득
    • Journal of the Korean Home Economics Association
    • /
    • v.28 no.1
    • /
    • pp.1-7
    • /
    • 1990
  • This study was carried out to investigate the influence of the various physiological function caused by girdle wearing. The four experimental methods used in this study are as follows. For example, the Reentgen photographing, body measurement by Sliding Gauge, mensurement of the electrocardiogram, measurement of the pulse and the blood pressure. The results of the investigation were as follows; 1. In the change of the various organs by Roentgen photographing, the diaphragm rised a little than normal position. The heart and stomach inclined to right side and the shape of stomach and duodenum are longer than the length of normal shape. Especially the phlorus of stomach was pressured strongly. 2. In the experimental change by the Sliding gauge and body measurement, the waist, hip and theigh girth of wearing-girdle reduced than at the no-girdle. The protruson of abdomen and hip section of wearing-girdle and the phenomenon of Hip-Up showed. 3. The difference by measurement of the electrocardiogram wasn't showed. The pulse of the wearing-girdle was increased slightly than the no-girdle. 4. The blood pressure of the wearing-girdle decreased slightly than the no-girdle.

  • PDF

Numerical and Experimental Analyses of a Hot-Wire Gas Flowmeter

  • Kim, Byoung-Chul;Joung, Ok-Jin;Kim, Young-Han
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1201-1206
    • /
    • 2003
  • A measurement device for gas flow rate using hot-wire module is developed for the utilization in low-accuracy industrial applications. The module has three wires of measuring and heating, and a bridge circuit is installed to detect electric current through the wire in the module. An amplification of the signal and conversion to digital output are conducted for the online measurement with a personal computer. In addition, temperature distribution in the module is numerically analyzed to examine the measured outcome from the module experiment. The flow rate of air and carbon dioxide gas is separately measured for the performance examination of the device. The experimental relation of measurement and flow agrees with the prediction from the numerical analysis. The outcome of the performance test indicates that the accuracy and reproducibility of the module is satisfactory for the purpose of industrial applications.

  • PDF

Performance Tests on the 3D-Flow-Structure-Interactions-Measurement System(FSIMS) (유체-구조 연동운동 3차원 측정시스템의 성능 검증)

  • Doh, Deog-Hee;Jo, Hyo-Jae;Baek, Tae-Sil;Hwang, Tae-Gyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.1
    • /
    • pp.81-89
    • /
    • 2009
  • Performance tests on the 3-Dimensional Flow-Structure-Interactions-Measurement System(FSIMS) have been carried out. Experimental data obtained by the FSIMS on a floating cylinder have been used to generate a set of artificial images. Comparisons between the data obtained by the use of the artificial images and those original experimental data have been made. Another set of artificial images have also been generated based on theoretically modulated sinusoidal motions, and comparisons between the data obtained by the use of these artificial images and the theoretical ones have been carried out. It has been verified that the FSIMS has a measurement uncertainty of 0.04-0.06mm/frame for velocity vectors and 0.002-0.01mm for the cylinder's positions.

A Pilot study of poroelastic modulus measurement in micro-bone tissue (미세 골조직의 공극탄성계수 측정을 위한 예비 연구)

  • 박영환;홍정화
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1038-1041
    • /
    • 2004
  • In this study, developed a micro-level experimental setup to measure pore pressure and poroelastic modulus in various strain and strain rate about a stress in micro-structure of bone tissue. It is essential device in the development of the model to analysis the interstitial bone fluid flow of the lacuno-canalicular system to be known that would effect on the bone remodeling. The constitution of the experimental setup is as follows, microscopic image processing system; actuator control unit; load measurement system. A pilot study was used an artificial chemical wood to have similar poroelastic property of bone matrix and conducted to validate the suitability of the measurement system.

  • PDF

Coating technique for use with remote measurement system at elevated temperatures (고온에서 원거리 측정 시스템을 활용하기 위한 코팅기술의 응용에 관한 연구)

  • 서창민;남승훈;이해무;김용일;김동석
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2000.04a
    • /
    • pp.164-169
    • /
    • 2000
  • The remote measurement system(RMS) as a new experimental method is limited in its application to crack measurements at elevated temperatures because of the oxide layer on the specimen surface. Since TiAlN and Cr coating layers have a high resistance to oxidation and wear, this paper proposed a TiAlN and Cr coating technique for specimens to facilitate the measurement of crack growth behavior using RMS. To investigate the effects of the coating layer, tension and fatigue tests were carried out at room temperature and at 538$^{\circ}C$, using specimens of 1Cr-1Mo-0.25V steel. From the experimental results, it was found that the mechanical properties of the TiAlN and Cr coated specimens were similar to those of the substrate. Accordingly, the TiAlN and Cr coated layer had hardly any influence on the fatigue crack propagation.

  • PDF