• Title/Summary/Keyword: evaluation methods & instruments

Search Result 140, Processing Time 0.031 seconds

Evaluation of canal preparation for apical sealing with various Ni-Ti rotary instruments (수 종의 Ni-Ti 회전 기구들을 이용한 치근단 폐쇄 향상을 위한 근관 확대 평가)

  • Shin, Yoo-Seok;Shin, Su-Jung;Song, Min-Ju;Kim, Eui-Seong
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.4
    • /
    • pp.300-305
    • /
    • 2011
  • Objectives: The aim of this study was to evaluate the various NiTi rotary instruments regarding their ability to provide a circular apical preparation. Materials and Methods: 50 single canal roots were selected, cut at the cementodentinal junction and the coronal 1/3 of the canals was flared using Gates Glidden burs. Samples were randomly divided into 5 experimental groups of 10 each. In group I, GT files, Profile 04 and Quantec #9 and #10 files were used. In Group II Lightspeed was used instead of Quantec. In Group III, Orifice shaper, Profile .06 series and Lightspeed were used. In Group IV, Quantec #9 and #10 files were used instead of Lightspeed. In Group V, the GT file and the Profile .04 series were used to prepare the entire canal length. All tooth samples were cut at 1 mm, 3 mm and 5 mm from the apex and were examined under the microscope. Results: Groups II and III (Lightspeed) showed a more circular preparation in the apical 1mm samples than the groups that used Quantec (Group I & IV) or GT files and Profile .04 series.(Group V)(p < 0.05) There was no significant difference statistically among the apical 3, 5 mm samples. In 5 mm samples, most of the samples showed complete circularity and none of them showed irregular shape. Conclusions: Lightspeed showed circular preparation at apical 1 mm more frequently than other instruments used in this study. However only 35% of samples showed circularity even in the Lightspeed Group which were enlarged 3 ISO size from the initial apical binding file (IAF) size. So it must be considered that enlarging 3 ISO size isn't enough to make round preparation.

Evaluation of Health-related Quality of Life for Hypothesized Medical States Associated with Cervical Cancer

  • Murasawa, Hideki;Konno, Ryo;Okubo, Ichiro;Arakawa, Ichiro
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.22
    • /
    • pp.9679-9685
    • /
    • 2014
  • Background: When evaluating health-economics for cervical cancer prevention policies in Japan, it is important to use Japanese value settings. This study aimed to obtain preference-based measures (preference measures) for hypothesized health states among healthy Japanese women, and to examine differences between the EuroQol-5D (EQ-5D) and standard gamble (SG) instruments. Materials and Methods: The investigation was performed among female students at a nursing university. We used written hypothetical scenarios describing three grades of cervical intraepithelial neoplasia (CIN) and eight stages of cervical cancer, both at diagnosis and after medical intervention. Preference measures were evaluated using both EQ-5D and SG. Results: We received responses from 136 women. The mean number of respondents per stage was 24.6 (SD: 2.7). At diagnosis, average EQ-5D scores for CIN1, CIN2, CIN3, IA1, IA2, IB1, IB2, IIA, IIB, III, and IV stages were 0.84 (0.14), 0.78 (0.12), 0.73 (0.10), 0.78 (0.12), 0.72 (0.12), 0.63 (0.13), 0.64 (0.12), 0.68 (0.08), 0.62 (0.13), 0.55 (0.21), and 0.18 (0.24), respectively. Using one-way analysis of variance with the Tukey-Kramer method for multiple comparisons (each stage vs. CIN1), we found significant differences for IB1 and more advanced stages (p<0.05). After medical intervention, corresponding EQ-5D scores were 0.84 (0.12), 0.81 (0.12), 0.84 (0.12), 0.80 (0.15), 0.78 (0.11), 0.64 (0.15), 0.63 (0.15), 0.71 (0.15), 0.50 (0.17), 0.52 (0.17), 0.21 (0.28). The multiple comparisons identified significant differences for IB1 and more advanced stages, excepting IIA (p<0.05). SG evaluations were more variable and relatively higher than EQ-5D evaluations. Conclusions: We obtained preference measures for three grades of CIN1-3 and eight stages of cervical cancer. In combination with appropriate sensitivity analyses, these preference measures will provide a basis for an economic evaluation of cervical cancer prevention in Japan. We suggest that EQ-5D is appropriate for cost-utility analysis of this topic.

Evaluation of Effect of Long Period Usage of Concentrated Ginseng Cream Using Eastern and Western Medicine Techniques (인삼농축크림 장기사용자의 동서의학적 피부 특성 고찰)

  • Cho, Ga Young;Yeom, Myung Hun;Park, Seong Il;Cho, Jun Cheol;Yu, Sun Hye;Choi, Yoon Jung;Kim, Jong Il
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.39 no.3
    • /
    • pp.167-175
    • /
    • 2013
  • The aim of this study is to evaluate the effect of cosmetic products containing concentrated ginseng using novel methods based on Traditional Korean medicine (TKM). In TKM, inspection of facial skin was an important method to diagnose symptoms and body condition of patients. Doctors in oriental medicine examined a patient as observing symptoms on the face and skin related to inner organs. This was called "mang-jin. In this study, eleven female, who have been using the cosmetic products containing concentrated ginseng for the last 5 years, and eleven healthy controls, who have never used the same product, were recruited. Three doctors in oriental medicine evaluated 17 inspection factors on facial skin. And 7 non-invasive skin bioengineering factors were assessed by various instruments at the same time. In results, 7 factors of the inspection were better in using the product than in controls. And sebum, roughness, pigmentation and wrinkle depth were significantly lower in using the product than in controls. So, this results propose that the cosmetic product containing concentrated ginseng has a good anti-aging effect on skin. And it is suggested that the novel evaluation method combined, Traditional Korean medicine and modern bioengineering technique, has to be developed for holistic concept of Hanbang cosmetics.

Validating the Korean Translation of the Behavioral Pediatric Feeding Assessment Scale (Behavioral Pediatric Feeding Assessment Scale(BPFAS)의 번안 연구)

  • Son, Cho-Rok;Kim, Kyeong-Mi;Kam, Kyung-Yoon;Jung, Hyerim
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.18 no.2
    • /
    • pp.29-41
    • /
    • 2020
  • Objective : This study was conducted to verify the validity of the content of the Behavioral Pediatric Feeding Assessment Scale (BPFAS) following its translation into Korean, to allow the instrument to be used in Korea. Methods : The BPFAS was translated by the researcher and a pediatric occupational therapist with 12 years' experience. To validate the contents of the translated instrument, it was reviewed by three professors in the Department of Occupational Therapy who have taught how to evaluate instruments or conducted related research. The BPFAS was then translated back into English by a professional translator whose native language is English but who is fluent in Korean. The contents of the instrument were verified by using it to survey five parents with normally developed children aged between 9 and 72 months. The BPFAS instrument was successfully revised for use in Korea. Results : The content validity index (CVI) of the Korean version of the evaluation of children's eating behavior was an average of 0.9 points in the fluency area, an average of 0.8 points in the semantic area, and an average of 1 points in the technology area, and the overall average was 0.8 points or more. The average of the content understanding score was 3 points or more. Conclusion : It was confirmed that the Korean version of the BPFAS is an evaluation tool with high content validity and can be usefully used to gather data in clinical trials and research in Korea.

The Domestic Trends of Korean Medicine Treatments on Traffic Accident for Recent 5 Years (최근 5년간 교통사고 후유증의 한의학적 치료에 대한 국내 연구 동향)

  • Choi, Young-Il;Kim, Min-Yeong;Choi, Hee-Seung;Jeong, Yun-Gyu;Ro, Hae-Rin;Kim, Se-Jun;Shin, Dong-Jae
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.8 no.1
    • /
    • pp.27-38
    • /
    • 2013
  • Objectives : The purpose of this study is to investigate the latest trends of korean Medicine treatments on traffic accident for recent 5 years. Methods : We investigated the studies on korean Medicine treatments for traffic accident via searching 6 Korean web databases. As a result, 65 research papers were found to be analyzed according to their published year, the titles of journals, the types of study, the number of cases, the sites of injury, the types of treatments the instruments for assessment and ethics approvals. Results : 65 articles were published since 2008. The studies on korean Medicine treatments about traffic accident were mainly published in Journal of Oriental Rehabilitation Medicine. 10 case studies, 14 case series, 11 non randomized controlled trials, 21 randomized controlled trials and 9 systemic reviews had been under research. The most frequently occurred symptoms were neck pain and low back pain. In most studies, various korean Medicine treatments were used to treat the symptoms. Visual analogue scale(VAS) and neck disability index(NDI) were used as primary assessments. In most clinical studies, there were no mention about approval of institutional review board(IRB). Conclusion : In this study, we analyzed the trends of korean Medicine treatments on traffic accident from 2008 to 2012. Reviewing the domestic trends of studies on korean Medicine treatments for traffic accident and examining the strong and weak points of those treatments are essential for the future studies. It is needed to adopt the qualitative methods of evaluation in order to develop a level of evidence.

  • PDF

MARGINAL FIT OF CELAY/IN-CERAM, CONVENTIONAL IN-CERAM AND EMPRESS 2 ALL-CERAMIC SINGLE CROWNS (Celay/In-Ceram, Conventional In-Ceram, Empress 2 전부도재관의 변연적합도에 관한 비교 연구)

  • Yang, Jae-Ho;Yeo, In-Sung;Lee, Sun-Hyung;Han, Jung-Suk;Lee, Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.2
    • /
    • pp.131-139
    • /
    • 2002
  • There have been many studies about marginal discrepancy of single restorations made by various systems and materials. But many of statistical inferences are not definite because of sample size, measurement number, measuring instruments. etc. The purpose of this study was to compare the marginal adaptations of the anterior single restorations made by different systems and to consider more desirable statistical methods in analysing the marginal fit. The in vitro marginal discrepancies of three different all-ceramic crown systems (Celay In-Ceram. Conventional In-Ceram. IPS Empress 2 layering technique) and one control group (PFM) were evaluated and compared. The crowns were made from one extracted maxillary central incisor prepared with a 1mm shoulder margin and $6^{\circ}$ taper walls by milling machine. 10 crowns per each system were fabricated. Measurements or a crown were recorded at 50 points that were randomly selected for marginal gap evaluation. Non-parametric statistical analysis was performed for the results. Within the limits of this study, the following conclusions were drawn: 1 Mean gap dimensions and standard deviations at the marginal opening for the maxillary incisor crowns were $98.2{\pm}40.6{\mu}m$ for PFM, $83.5{\pm}18.7{\mu}m$ for Celay In-Ceram, $104.9{\pm}44.1{\mu}m$ for conventional In-Ceram, and $45.5{\pm}11.5{\mu}m$ for IPS Empress 2 layering technique. The IPS Empress 2 system showed the smallest marginal gap (P<0.05). The marginal openings of the other three groups were not significantly different (P<0.05). 2 The marginal discrepancies found in this study were all within clinically acceptable standards ($100\sim150{\mu}m$). 3. When the variable is so controlled that the system may be the only one, mean value is interpreted to be the marginal discrepancy of a restoration which is made by each system and standard deviation is to be technique-sensitivity of each one. 4. From the standard deviations. the copy-milling technique (Celay/In-Ceram) was not considered to be technique-sensitive in comparison with other methods. 5. Parametric analysis is more reliable than non-parametric one in interpretation of the mean and standard deviation. The sample size of each group has to be more than 30 to use parametric statistics. The level of clinically acceptable marginal fit has not been established. Further studies are needed.

IN VITRO EVALUATION OF CLEANING EFFICACY OF VARIOUS IRRIGATION METHODS IN MANDIBULAR MOLARS (하악 대구치에서 근관세척방법에 따른 잔사제거효과에 대한 평가)

  • Lee, So-Young;Son, Won-Jun;Lee, Woo-Cheol;Kum, Kee-Yeon;Bae, Kwang-Shik;Baek, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.3
    • /
    • pp.215-222
    • /
    • 2009
  • The aim of this in vitro study was to evaluate the cleaning efficacy of various irrigation methods in the mandibular mesial roots. The forty five mesial root canals were shaped by Profile .06 instruments to apical size #30 and irrigated with 5ml of 3.5% NaOCl. The teeth were divided into 3 groups and irrigated finally for 1 minute; Group 1: syringe irrigation. Group 2: ultrasonic irrigation. Group 3: RinsEndo irrigation. After histological processing, the cross sections of apical 1, 3, and 5 mm level were examined with an optical microscope. The cleanliness values of canals and isthmuses were calculated and analyzed by Mann-Whitney U test. 1. There were no significant differences in both canal and isthmus cleanliness between syringe irrigation and ultrasonic irrigation except 5 mm level of isthmus. 2. RinsEndo irrigation had significantly higher canal cleanliness values than syringe irrigation at 1 mm and 3 mm levels (p<0.05). Also, RinsEndo irrigation had significantly higher isthmus cleanliness values than syringe irrigation at all levels evaluated (p<0.05). 3. There were no statistical differences in both canal and isthmus cleanliness between ultrasonic irrigation and RinsEndo irrigation except 3 mm level of canal. From this study, RinsEndo irrigation can be useful as an additional irrigation procedure.

Study of Soil Erosion for Evaluation of Long-term Behavior of Radionuclides Deposited on Land (육상 침적 방사성 핵종의 장기 거동 평가를 위한 토사 침식 연구)

  • Min, Byung-Il;Yang, Byung-Mo;Kim, Jiyoon;Park, Kihyun;Kim, Sora;Lee, Jung Lyul;Suh, Kyung-Suk
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.1
    • /
    • pp.1-13
    • /
    • 2019
  • The accident at the Fukushima Dai-ichi Nuclear Power Plant (FDNPP) resulted in the deposition of large quantities of radionuclides over parts of eastern Japan. Radioactive contaminants have been observed over a large area including forests, cities, rivers and lakes. Due to the strong adsorption of radioactive cesium by soil particles, radioactive cesium migrates with the eroded soil, follows the surface flow paths, and is delivered downstream of population-rich regions and eventually to coastal areas. In this study, we developed a model to simulate the transport of contaminated sediment in a watershed hydrological system and this model was compared with observation data from eroded soil observation instruments located at the Korea Atomic Energy Research Institute. Two methods were applied to analyze the soil particle size distribution of the collected soil samples, including standardized sieve analysis and image analysis methods. Numerical models were developed to simulate the movement of soil along with actual rainfall considering initial saturation, rainfall infiltration, multilayer and rain splash. In the 2019 study, a numerical model will be used to add rainfall shield effect by trees, evaporation effect and shield effects of surface water. An eroded soil observation instrument has been installed near the Wolsong nuclear power plant since 2018 and observation data are being continuously collected. Based on these observations data, we will develop the numerical model to analyze long-term behavior of radionuclides on land as they move from land to rivers, lakes and coastal areas.

THE COMPARATIVE EVALUATION USING HATCH REAMER TECHNIQUE AND OSTEOTOME TECHNIQUE IN SINUS FLOOR ELEVATION (상악동저 거상술 시 Osteotome 술식과 Hatch Reamer 술식의 비교평가)

  • Cho, Seong-Woong;Kim, Sang-Jung;Lee, Dong-Keun;Kim, Chin-Soo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.2
    • /
    • pp.154-161
    • /
    • 2010
  • Many edentulous posterior maxilla are found to be compromised by alveolar resorption and increased pneumatization of the sinus. One of the surgical procedures to overcome this anatomical limitation is sinus floor elevation with bone graft, which is reported as more appropriate and more successful procedure. Commonly, if the residual bone height is over 5mm, sinus floor elevation is operated through transcrestal approach using osteotome technique. But, it is possible for patients to feel discomfort during operation and dizziness after operation while malleting, sinus floor elevation, using osteotome technique. Some instruments and methods has been used to overcome these problems and use more easily. The aim of this study is to compare between the surgical procedure of sinus floor elevation using Hatch reamer technique and that of sinus floor elevation using osteotome technique. From 2004 Feb to 2007 Oct, we investigate patients (osteotome group: 72, Hatch reamer group: 70) who were given implant surgery with sinus floor elevation (osteotome group: 92, Hatch reamer group: 98). We analysed gender, age, residual bone height, amount of sinus floor elevation, used graft material, total success rate, failure rate by residual bone height and implant type and discomfort during operation, etc. The results obtained were as follows. 1. In the amount of sinus elevation was osteotome group was $3.85{\pm}1.02\;mm$ and Hatch reamer group was $3.93{\pm}1.38\;mm$. There was no statistically significant difference between the two groups (P > 0.05). 2. At the total success rate, osteotome group was 92.4% and Hatch reamer group was 94.9%. There was no statistically significant difference between the two groups (P > 0.05). 3. On the discomfort during the operation by using numerical rating scale, osteotome group was $2.87{\pm}0.83$ and Hatch reamer group was $1.12{\pm}0.64$. There was statistically significant difference between the two groups (P < 0.05). The Hatch reamer group clinical results was similar to osteotome group and we thought that Hatch reamer technique can overcome the faults of osteotome technique.

IN VITRO MARGINAL FIT OF THE COMPUTERAIDED MILLED CERCON CROWNS

  • Chang, Jae-Yoon;Yang, Jae-Ho;Han, Jung-Suk;Lee, Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.3
    • /
    • pp.306-313
    • /
    • 2005
  • Statement of problem. There have been many studies about marginal discrepancy of single restorations made by various systems and materials. But most of statistical inferences are not definite because of sample size, measurement number, measuring , instruments, etc. And there have been few studies about the marginal fit of Computer-aided Cercon crowns. Purpose. The purpose of this study was to compare the marginal fit of the anterior single restorations made using computer-aided milled Cercon crowns with metal-ceramic restorations and to obtain more accurate information by using a large enough sample size and by making sufficient measurements per specimen. Material and methods. The in vitro marginal discrepancies of computer-aided milled Cercon crowns and control groups (metal ceramic crowns) were evaluated and compared. The crowns were made from one extracted maxillary central incisor prepared by milling machine. 30 crowns per each system were fabricated. Measurements of a crown were recorded at 50 points that were randomly selected for marginal gap evaluation. Parametric statistical analysis was performed for the results. Results. The means and standard deviations of the marginal fit were 85$\pm$22$\mu$m for the control group and 91$\pm$15$\mu$m for the Cercon crowns. The t-test of the marginal discrepancies between Cercon crowns and metal-ceramic crowns were performed. Significant differences were not found between groups (P=0.230>.05). Based on the criterion of 120$\mu$m as the limit of clinical acceptability, the mean marginal fits of Cercon crowns and metal-ceramic crowns were acceptable. Conclusion. Within the limitations of this in vitro study, the following conclusions were drawn: 1. Mean gap dimensions and standard deviations at the marginal opening for maxillary incisal crowns were 85$\pm$22$\mu$m for the control (metal-ceramic crowns), 91$\pm$15$\mu$m for Cercon crowns. 2. The Cercon crowns showed slightly larger marginal gap discrepancy than the control but marginal gap between Computer-aided milled Cercon crowns and metal ceramic crowns did not showed significant difference (P>.05). 3. The Cercon crowns and metal ceramic crowns showed clinically acceptable marginal discrepancy.