• Title/Summary/Keyword: evaluation method

Search Result 21,773, Processing Time 0.058 seconds

Assessment on Accuracy of Stereotactic Body Radiation therapy (SBRT) using VERO (VERO system을 이용한 정위적 체부 방사선치료(SBRT)의 정확성 평가)

  • Lee, Wi Yong;Kim, Hyun Jin;Yun, Na Ri;Hong, Hyo Ji;Kim, Hong Il;Baek, Seung Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.17-24
    • /
    • 2019
  • Purpose: The present study aims to assess the level of coherency and the accuracy of Point dose of the Isocenter of VERO, a linear accelerator developed for the purpose of the Stereotactic Body Radiation Therapy(SBRT). Materials and Method: The study was conducted randomly with 10 treatment plans among SBRT patients in Kyungpook National University Chilgok Hospital, using VERO, a linear accelerator between June and December, 2018. In order to assess the equipment's power stability level, we measured the output constancy by using PTW-LinaCheck, an output detector. We also attempted to measure the level of accuracy of the equipment's Laser, kV(Kilo Voltage) imaging System, and MV(Mega Voltage) Beam by using Tofu Phantom(BrainLab, Germany) to assess the accuracy level of geometrical Isocenter. We conducted a comparative analysis to assess the accuracy level of the dose by using an acrylic Phantom($30{\times}30{\times}20cm$), a calibrated ion chamber CC-01(IBA Dosimetry), and an Electrometer(IBA, Dosimetry). Results: The output uniformity of VERO was calculated to be 0.66 %. As for geometrical Isocenter accuracy, we analyzed the error values of ball Isocenter of inner Phantom, and the results showed a maximum of 0.4 mm, a minimum of 0.0 mm, and an average of 0.28 mm on X-axis, and a maximum of -0.4 mm, a minimum of 0.0 mm, and an average of -0.24 mm on Y-axis. A comparison and evaluation of the treatment plan dose with the actual measured dose resulted in a maximum of 0.97 % and a minimum of 0.08 %. Conclusion: The equipment's average output dose was calculated to be 0.66 %, meeting the ${\pm}3%$ tolerance, which was considered as a much uniform fashion. As for the accuracy assessment of the geometric Isocenter, the results met the recommended criteria of ${\pm}1mm$ tolerance, affirming a high level of reproducibility of the patient's posture. The difference between the treatment plan dose and the actual measurement dose was calculated to be 0.52 % on average, significantly less than the 3 % tolerance, confirming that it obtained predicted does. The current study suggested that VERO equipment is suitable for SBRT, and would result in notable therapeutic effect.

Investigation of Microbial Contamination in Semisulcospira libertine and Evaluation of Its Reduction Effects by Sediment Removal Treatment (다슬기(Semisulcospira libertine)의 미생물 오염도 평가 및 해감 제거공정에 따른 저감화 효과)

  • Choi, Man-Seok;Jun, Eun Bi;Choi, Seungho;Bang, Hyeon-Jo;Park, Shin Young
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.4
    • /
    • pp.361-366
    • /
    • 2019
  • In this study, microbial contamivation semisulcospira libertine and effect of sedimentation treatment of major bacterial and fungal pathogens were investigated. The total aerobic bacteria, coliforms, Escherichia coli, Staphylococcus aureus, and yeast and mold present in raw and water-dipped Semisulcospira libertine were enumerated using the standard plate count methods on using the standard plate method on potato dextrose agar (PDA), 3M Petrifilm for coliforms / E. coli, 3M Petrifilm for S. aureus, and plate count agar (PCA), respectively. In analysis of microbial contamination of raw Semisulcospira libertine, the total aerobic bacteria, coliforms, and yeast and mold were monitored as 6.40, 2.70, and $6.79{\log}_{10}CFU/g$, respectively. Both E. coli and S. aureus were not detected (detection limit: 10 CFU/g). However, Semisulcospira libertine dipped in ground water for 3 hours had higher contamination levels of all natural indigenous microorganisms than raw Semisulcospira libertine. Especially, E. coli was detected as $2.46{\log}_{10}CFU/g$ in the ground water-dipped Semisulcospira libertine. The total aerobic bacteria in the ground water-dipped Semisulcospira libertine was not significantly reduced (p>0.05) compared to that in the raw Semisulcospira libertine. Moreover, coliforms were significantly increased (p>0.05) in all water-dipped Semisulcospira libertine. Only fungi were slightly reduced (less than 0.2 log) (p>0.05) in the tap water-dipped Semisulcospira libertine by comparison with the raw Semisulcospira libertine. The results of this study suggest that the use of chemical sterilizing agents and other physical methods in the washing stage will be necessary for the microbial reduction in raw Semisulcospira libertine because the use of sediment removal treatment by ground or tap water did not affect the microbiological safety of the raw Semisulcospira libertine.

Comparative evaluation of marginal and internal fit of metal copings fabricated by various CAD/CAM methods (다양한 CAD/CAM 방식으로 제작한 금속하부구조물 간의 변연 및 내면 적합도 비교 연구)

  • Jeong, Seung-Jin;Cho, Hye-Won;Jung, Ji-Hye;Kim, Jeong-Mi;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.211-218
    • /
    • 2019
  • Purpose: The purpose of the present study was to compare the accuracy of four different metal copings fabricated by CAD/CAM technology and to evaluate clinical effectiveness. Materials and methods: Composite resin tooth of the maxillary central incisor was prepared for a metal ceramic crown and duplicated metal die was fabricated. Then scan the metal die for 12 times to obtain STL files using a confocal microscopy type oral scanner. Metal copings with a thickness of 0.5 mm and a cement space of $50{\mu}m$ were designed on a CAD program. The Co-Cr metal copings were fabricated by the following four methods: Wax pattern milling & Casting (WM), Resin pattern 3D Printing & casting (RP), Milling & Sintering (MS), Selective laser melting (SLM). Silicone replica technique was used to measure marginal and internal discrepancies. The data was statistically analyzed with One-way analysis of variance and appropriate post hoc test (Scheffe test) (${\alpha}=.05$). Results: Mean marginal discrepancy was significantly smaller in the Group WM ($27.66{\pm}9.85{\mu}m$) and Group MS ($28.88{\pm}10.13{\mu}m$) than in the Group RP ($38.09{\pm}11.14{\mu}m$). Mean cervical discrepancy was significantly smaller in the Group MS than in the Group RP. Mean axial discrepancy was significantly smaller in the Group WM and Group MS then in the Group RP and Group SLM. Mean incisal discrepancies was significantly smaller in the Group RP than in all other groups. Conclusion: The marginal and axial discrepancies of the Co-Cr coping fabricated by the Wax pattern milling and Milling/Sintering method were better than those of the other groups. The marginal, cervical and axial fit of Co-Cr copings in all groups are within a clinically acceptable range.

A Study on the Change of Image Quality According to the Change of Tube Voltage in Computed Tomography Pediatric Chest Examination (전산화단층촬영 소아 흉부검사에서 관전압의 변화에 따른 화질변화에 관한 연구)

  • Kim, Gu;Kim, Gyeong Rip;Sung, Soon Ki;Kwak, Jong Hyeok
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.503-508
    • /
    • 2019
  • In short a binary value according to a change in the tube voltage by using one of VOLUME AXIAL MODE of scanning techniques of chest CT image quality evaluation in order to obtain high image and to present the appropriate tube voltage. CT instruments were GE Revolution (GE Healthcare, Wisconsin USA) model and Phantom used Pediatric Whole Body Phantom PBU-70. The test method was examined in Volume Axial mode using the pediatric protocol used in the Y university hospital of mass-produced material. The tube voltage was set to 70kvp, 80kvp, 100kvp, and mAs was set to smart mA-ODM. The mean SNR difference of the heart was $-4.53{\pm}0.26$ at 70 kvp, $-3.34{\pm}0.18$ at 80 kvp, $-1.87{\pm}0.15$ at 100 kvp, and SNR at 70 kvp was about -2.66 higher than 100 kvp and statistically significant (p<0.05) In the Lung SNR mean difference analysis, $-78.20{\pm}4.16$ at 70 kvp, $-79.10{\pm}4.39$ at 80 kvp, $-77.43{\pm}4.72$ at 100 kvp, and SNR at 70 kvp at about -0.77 higher than 100 kvp were statistically significant. (p<0.05). Lung CNR mean difference was $73.67{\pm}3.95$ at 70 kvp, $75.76{\pm}4.25$ at 80 kvp, $75.57{\pm}4.62$ at 100 kvp and 20.9 CNR at 80 kvp higher than 70 kvp and statistically significant (p<0.05) At 100 kvp of tube voltage, the SNR was close to 1 while maintaining the quality of the heart image when 70 kvp and 80 kvp were compared. However, there is no difference in SNR between 70 kvp and 80 kvp, and 70 kvp can be used to reduce the radiation dose. On the other and, CNR showed an approximate value of 1 at 70 kvp. There is no difference between 80 kvp and 100 kvp. Therefore, 80 kvp can reduce the radiation dose by pediatric chest CT. In addition, it is possible to perform a scan with a short scan time of 0.3 seconds in the volume axial mode test, which is useful for pediatric patients who need to move or relax.

Utility Evaluation of Supportive Devices for Interventional Lower Extremity Angiography (인터벤션 하지 혈관조영검사를 위한 보조기구의 유용성 평가)

  • Kong, Chang gi;Song, Jong Nam;Jeong, Moon Taek;Han, Jae Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.613-621
    • /
    • 2019
  • The purpose of this study is to evaluate the effectiveness of supportive devices which are for minimizing the patient's movement during lower extremity angiography and to verify image quality of phantom by analyzing of Mask image, DSA image and Roadmap image into SNR and CNR. As a result of comparing SNR with CNR of mask image obtained by DSA technique using the phantom alone and phantom placed on the supportive devices, there was no significant difference between about 0~0.06 for SNR and about 0~0.003 for CNR. The study showed about 0.11~0.35 for SNR and 0.016~0.031 for CNR of DSA imaging by DSA technique about only water phantom of the blood vessel model and the water phantom placed on the device. Analyzing SNR and CNR of Roadmap technique about water phantom on the auxiliary device (hardboard paper, pomax, polycarbonate, acrylic) and water phantom alone, there was no significant difference between 0.02~0.05 for SNR and 0.002~0.004 for CNR. In conclusion, there was no significant difference on image quality by using supportive devices made by hardboard paper, pomax, polycarbonate or acryl regardless of whether using supportive devices or not. Supportive devices to minimize of the patient's movement may reduce the total amount of contrast, exam-time, radiation exposure and eliminate risk factors during angiogram. Supportive devices made by hardboard paper can be applied easily during angiogram due to advantages of reasonable price and simple processing. It is considered that will be useful to consider cost efficiency and types of materials and their properties in accordance with purpose and method of the study when the operator makes and uses supportive devices.

Development of Samgyetang Broth from Air-dried and Oven-roasted Chicken Feet (열풍건조 및 오븐구이 닭발로부터 추출한 삼계탕 육수 제조)

  • Kim, Juntae;Utama, Dicky Tri;Jeong, Hae Seong;Heidar, Barido Farouq;Jang, Aera;Pak, Jae In;Kim, Yeong Jong;Lee, Sung Ki
    • Korean Journal of Poultry Science
    • /
    • v.46 no.3
    • /
    • pp.137-154
    • /
    • 2019
  • This study was conducted to develop and compare Samgyetang broth from extract of pre-treated chicken feet. Chicken feet were subjected to non-heating (control), heating at $70^{\circ}C$ for 12 h in a hot air dryer, and heating at $180^{\circ}C$ for 1 h in an oven. The heat-treated chicken feet were extracted at $121^{\circ}C$ for 1 h and 2 h, respectively. The extract was placed in a pouch with whole chicken carcass ($470{\pm}10g$). The sealed Samgyetang retort was made according to the industrial method. The pH of the extract from preheated chicken feet was lower than that extracted from fresh chicken feet. The Thiobarbituric Acid Reactive Substances (TBARS) value of the preheated chicken feet extract was significantly lower (P<0.05) than that of fresh chicken feet extract, but there were no significant differences among the broths. As the extraction time increased, the pH and TBARS value decreased in the extract (P<0.05) but increased in the broth (P<0.05). According to the sensory evaluation test, the extract from 1 h hot air heating and drying was significantly better in appearance, aroma, and overall preference than the other treatments (P<0.05). The GC-MS results showed that benzaldehyde and benzothiazole, which are widely known to give meat and nuts flavor, were detected in those treatments (P<0.05). The Samgyetang broths prepared from 1 h hot air heating and drying extract were significantly higher in the overall acceptability according to the sensory test (P<0.05). In summary, the quality of retort Samgyetang broth can be improved by adding chicken feet extract which is subjected to heating and drying for 1 h.

Detection Ability of Occlusion Object in Deep Learning Algorithm depending on Image Qualities (영상품질별 학습기반 알고리즘 폐색영역 객체 검출 능력 분석)

  • LEE, Jeong-Min;HAM, Geon-Woo;BAE, Kyoung-Ho;PARK, Hong-Ki
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.22 no.3
    • /
    • pp.82-98
    • /
    • 2019
  • The importance of spatial information is rapidly rising. In particular, 3D spatial information construction and modeling for Real World Objects, such as smart cities and digital twins, has become an important core technology. The constructed 3D spatial information is used in various fields such as land management, landscape analysis, environment and welfare service. Three-dimensional modeling with image has the hig visibility and reality of objects by generating texturing. However, some texturing might have occlusion area inevitably generated due to physical deposits such as roadside trees, adjacent objects, vehicles, banners, etc. at the time of acquiring image Such occlusion area is a major cause of the deterioration of reality and accuracy of the constructed 3D modeling. Various studies have been conducted to solve the occlusion area. Recently the researches of deep learning algorithm have been conducted for detecting and resolving the occlusion area. For deep learning algorithm, sufficient training data is required, and the collected training data quality directly affects the performance and the result of the deep learning. Therefore, this study analyzed the ability of detecting the occlusion area of the image using various image quality to verify the performance and the result of deep learning according to the quality of the learning data. An image containing an object that causes occlusion is generated for each artificial and quantified image quality and applied to the implemented deep learning algorithm. The study found that the image quality for adjusting brightness was lower at 0.56 detection ratio for brighter images and that the image quality for pixel size and artificial noise control decreased rapidly from images adjusted from the main image to the middle level. In the F-measure performance evaluation method, the change in noise-controlled image resolution was the highest at 0.53 points. The ability to detect occlusion zones by image quality will be used as a valuable criterion for actual application of deep learning in the future. In the acquiring image, it is expected to contribute a lot to the practical application of deep learning by providing a certain level of image acquisition.

Effect of polishing methods on color change by water absorption in several composite resins (여러 복합레진에서 수분 흡수에 의한 색변화에 연마가 미치는 영향)

  • Kim, Hye Jin;Kim, Mi-yeon;Song, Byung-chul;Kim, Sun-ho;Kim, Jeong-hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.1
    • /
    • pp.1-10
    • /
    • 2019
  • Purpose: The aim of this study was to evaluate the influence of polishing methods on the color stability of composite resins. Materials and Methods: Two bulk-fill and four conventional resin composites were filled in cylindrical molds (6 mm diameter, 4 mm height) and light-cured. The specimens were stored in $34^{\circ}C$ distilled water for 24 h. Spectrophotometer was used to determine the color value according to the CIE $L^*a^*b^*$ color space. Each group was divided into three groups according to polishing methods (n = 5). Group 1 was control group (Mylar strip group), group 2 was polished with PoGo, and group 3 was polished with Sof-Lex Spiral wheels. Color evaluation was performed weekly for 4 weeks after immersion in $34^{\circ}C$ distilled water. The results were analyzed by generalized least squares method (P < 0.05). Results: Generalized least squares analysis revealed that Sof-Lex Spiral wheels group showed the significantly lower ${\Delta}E$ values compared to PoGo and control group (P < 0.05). The ${\Delta}E$ values of polished group showed the significantly lower than the ${\Delta}E$ values of unpolished group (P < 0.05). Regarding color changes of composite resins, there was no significant difference between the ${\Delta}E$ values of Filtek Z250 and Filtek Z350 XT Universal restorative in all time intervals (P < 0.05). Tetric N-Ceram Bulk Fill showed the significantly lower ${\Delta}E$ values compared to other composite resins in 1, 2, 3 weeks (P < 0.05). Conclusion: Within the limitations of this study, polishing methods influence the color stabilities of composite resins. The group polished with Sof-Lex Spiral Wheels showed more resistance to discoloration than group polished with PoGo.

Components and Function of Artichoke Tea Prepared by Steaming and Drying Method (증숙 건조 방식으로 제조한 돼지감자차의 성분 및 기능성)

  • Hwang, Eun Gyeong;Lee, Seon Hyeon;Kim, Byung Ki;Kim, Soo Jung;Ann, Yong Geun;Doryoon, Monk;Oh, Sung-Cheon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.36 no.1
    • /
    • pp.1-12
    • /
    • 2019
  • After making tea by steaming the Artichoke(Hellanthus tuberosus) nine times and drying them nine times, the ingredients and functions of the Artichoke tea were compared to those of M. It had 342.27kcal/100g in its own deloped Artichoke tea, 73.87g/100g of carbohydrates, 6.80g/100g of crude ash and 8.21g/100g of crude protein. The total of free sugars were 32.66mg/100, among them, fructose 17.40, sucrose 9.03 and glucose 6.05 mg/100g. The total mineral contents of the developed tea was 2,785.67mg/100g. It was 2,563.93mg/100g of potassium, 97.52mg/100g of calcium and 88.78mg/100g of magnesium. The saturated fat of Artichoke tea was 30.34mg/100g and unsaturated fat was 69.66mg/100g, among which the linoleic acid was 47.0mg/100%, palmitic acid was 25.31mg/100% and linolenic acid was 8.61mg/100g. DPPH radical scavenging was 34.2% of teas that were developed, 5.2% of M's for comparison, and 44.0% of index materials. ABTS radical scavenging was 93.0% of teas developed, 61.9% of M's tea and 47.6% of index materials, and SOD like activity was 2.7% of teas developed and 1.6% of M's tea. The flavonoid content was 2.8 fold of the tea developed, 2.0 fold of M's tea and 1.7 fold of index material. The polyphenol content was 38.2 fold, 8.92 fold of M's tea and 14.0 fold of index material. The inhibition rate for ${\alpha}$-glucosidase was 9.83% teas developed and 8.92% of M's. The sensory evaluation compares to the one time extract and the five time extract. Based on the one-time extract, color of tea developed was 83.7%, the M's tea was 50.0%, the flavor was 78%, M's tea was 42.5%, the delicate taste was 66.7% of teas developed and M's tea was 37.5% and the overall acceptability was 73.3% of teas developed, M's tea was 47.5%. The comparison of M's tea showed that the extract decreased as we made it, and the overall symbol level decreased to 46.3% after five time-extyracts, while that of the developed tea decreased to 73.3%. The Artichoke tea developed this way is believed to have greater antioxidant function, higher effective substance content, and a higher affinity than M's tea an index material for comparison purposes.

Functionality and Components of Burdock Tea Prepared by Steaming and Drying Method (증숙 건조 방식에 의해 제조한 우엉차의 기능성 및 성분)

  • Hwang, Eun Gyeong;Lee, Seon Hyeon;Kim, Byung Ki;Kim, Soo Jung;Ann, Yong Geun;Doryoon, Monk;Oh, Sung-Cheon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.36 no.1
    • /
    • pp.23-33
    • /
    • 2019
  • After making tea by steaming the Burdock(Arctium lappa) nine times and drying it nine times, the ingredients and functions of the Burdock tea were compared to those of M company. The tea's calories were 346.48kcal/100g, carbohydrates were 72.75g/100g, crude protein was 11.98g/100g, and crude ash was 5.01g/100g. The total of free sugars were 31.93mg/100, among them, fructose was 26.27, sucrose was 1.27 mg/100g. The inorganic material contents were 1,476.21mg/100g of potassium, 255.96 mg/100g of calcium and 311.41 mg/100g of magnesium. The saturated fatty acids were 40.73mg/100g and the unsaturated fatty acids were 59.27mg/100g, among which the linoleic acid was 41.28mg/100g, the palmitic acid was 33.11mg/100g, the oleic acid was 10.07mg/100g and linolenic acid was 7.92mg/100g. DPPH radical scavenging was 33.9% of teas that were developed, 2.3% of M's tea for comparison, and 37.2% of indiex material. ABTS radical scavenging were 90.7% of teas developed, 85.9% of M's tea and 37.2% of index materials, and SOD like activities were 11.3% of teas developed and 50.5% of M's teas. The flavonoid content was 2.6 fold of the tea developed, 2.9 fold of M's tea and 1.7 fold of index material. The polyphenol content was 33.8 fold of teas developed, 38.9 fold of the M's tea and 13.8 fold of the index material. The sensory evaluation compare to the one-time extract and the five-time extract. Based on the one-time extract, the color were 65.9 % of the five-time extract tea were developed, 12.8 % of the M's tea. Flavour were 78.0% of the tea developed and 33.3% of the M's tea, tastes were 71.4% of the tea developed, 20.7% of the M's tea. The cart for comparison showed that while the extract decreased as we developed it, the overall symbolism decreased to 21.4% after five time extracts, the developed tea decreased to 72.1%. We believe that the developed tea will have a greater effect on preventing and improving diseases as it has a stronger antioxidant function, more effective substances, and a higher level of symbolism than the comparative M squared tea and surface substance.