A Study on the Change of Image Quality According to the Change of Tube Voltage in Computed Tomography Pediatric Chest Examination  

Kim, Gu (Department of Radiology, Pusan National University hospital of Yang San)
Kim, Gyeong Rip (Gamma knife center, Pusan National University Hospital of Yang San)
Sung, Soon Ki (Gamma knife center, Pusan National University Hospital of Yang San)
Kwak, Jong Hyeok (Department of Radiology, Pusan National University hospital of Yang San)
Publication Information
Journal of the Korean Society of Radiology / v.13, no.4, 2019 , pp. 503-508 More about this Journal
Abstract
In short a binary value according to a change in the tube voltage by using one of VOLUME AXIAL MODE of scanning techniques of chest CT image quality evaluation in order to obtain high image and to present the appropriate tube voltage. CT instruments were GE Revolution (GE Healthcare, Wisconsin USA) model and Phantom used Pediatric Whole Body Phantom PBU-70. The test method was examined in Volume Axial mode using the pediatric protocol used in the Y university hospital of mass-produced material. The tube voltage was set to 70kvp, 80kvp, 100kvp, and mAs was set to smart mA-ODM. The mean SNR difference of the heart was $-4.53{\pm}0.26$ at 70 kvp, $-3.34{\pm}0.18$ at 80 kvp, $-1.87{\pm}0.15$ at 100 kvp, and SNR at 70 kvp was about -2.66 higher than 100 kvp and statistically significant (p<0.05) In the Lung SNR mean difference analysis, $-78.20{\pm}4.16$ at 70 kvp, $-79.10{\pm}4.39$ at 80 kvp, $-77.43{\pm}4.72$ at 100 kvp, and SNR at 70 kvp at about -0.77 higher than 100 kvp were statistically significant. (p<0.05). Lung CNR mean difference was $73.67{\pm}3.95$ at 70 kvp, $75.76{\pm}4.25$ at 80 kvp, $75.57{\pm}4.62$ at 100 kvp and 20.9 CNR at 80 kvp higher than 70 kvp and statistically significant (p<0.05) At 100 kvp of tube voltage, the SNR was close to 1 while maintaining the quality of the heart image when 70 kvp and 80 kvp were compared. However, there is no difference in SNR between 70 kvp and 80 kvp, and 70 kvp can be used to reduce the radiation dose. On the other and, CNR showed an approximate value of 1 at 70 kvp. There is no difference between 80 kvp and 100 kvp. Therefore, 80 kvp can reduce the radiation dose by pediatric chest CT. In addition, it is possible to perform a scan with a short scan time of 0.3 seconds in the volume axial mode test, which is useful for pediatric patients who need to move or relax.
Keywords
Kvp; Computed Tomography; Volume axial;
Citations & Related Records
연도 인용수 순위
  • Reference
1 D. Brenner, C. Elliston, E. Hall, W. Berdon, “Estimated risks of radiation-induced fatal cancer from pediatric CT,” AJR. American journal of roentgenology, Vol. 176, No. 2, pp. 289-296, 2001.   DOI
2 National Research Council (US); Committee to Assess Health Risks from Exposure to Low Levels of Ionizing Radiation. Health risks from exposure to low levels of ionizing radiation: BEIR VII phase 2. Washington DC: National Academies Press; 2006.
3 https://www.hira.or.kr/eng/main.do
4 http://www.nifds.go.kr/
5 C. M Heyer, P. S Mohr, S.P Lemburg, S A Peters, “Image quality and radiation exposure at pulmonary CT angiography with 100- or 120-kVp protocol: Prospective randomized study,” Radiology, Vol. 245, No. 2, pp. 577-583, 2007.   DOI
6 Shinji Yoshinaga, Kiyohiko Mabuchi, Alice J Sigurdson, Michele Morin Doody, Elaine Ron, “Cancer risks among radiologists and radiologic technologists: review of epidemiologic studies,” Radiology, Vol. 233, No. 2, pp. 313-321, 2004.   DOI
7 ICRP, 1990 Recommendations of the International Commission on Radiological Protection. ICRP Publication 60, 1991. Annex C Bases for judging the significance of the effects of radiation.
8 F. A. Mettler Jr, P. W. Wiest, J. A. Locken, C. A. Kelsey, “CT scanning: patterns of use and dose,” Journal of Radiological Protection, Vol. 20, No. 4, pp. 353-362, 2000.   DOI
9 Joshua Broder, Lynn Ansley Fordham, David M. Warshauer, "Increasing utilization of computed tomography in the pediatric emergency department, 2000-2006," Emergency Radiology, Vol. 14, No. 4, pp. 277-232, 2007.   DOI