• Title/Summary/Keyword: error code

Search Result 1,620, Processing Time 0.031 seconds

Additional Thermometer Code Locking Technique for Minimizing Quantization Error in Low Area Digital Controlled Oscillators (저면적 디지털 제어 발진기의 양자화 에러 최소화를 위한 추가 서모미터 코드 잠금 기법)

  • Byeongseok Kang;Young-Sik Kim;Shinwoong Kim
    • Journal of IKEEE
    • /
    • v.27 no.4
    • /
    • pp.573-578
    • /
    • 2023
  • This paper introduces a new locking technique applicable to high-performance digital Phase-Locked Loops (DPLL). The study employs additional thermometer codes to reduce quantization errors in LC-based Digital Controlled Oscillators (DCO). Despite not implementing the entire DCO codes in thermometer mode, this method effectively reduces quantization errors through enhanced linearity. In the initial locking phase, binary codes are used, and upon completion of locking, the system transitions to thermometer codes, achieving high frequency linearity and reduced jitter characteristics. This approach significantly reduces the number of switches required and minimizes the oscillator's area, especially in applications requiring low DCO gain (Kdco), compared to the traditional method that uses only thermometer codes. Furthermore, the jitter performance is maintained at a level equivalent to that of the thermometer-only approach. The efficacy of this technique has been validated through modeling and design at the RTL level using SystemVerilog and Verilog HDL.

Using an appropriate rotation-based criterion to account for torsional irregularity in reinforced concrete buildings

  • Akshara S P;M Abdul Akbar;T M Madhavan Pillai;Rakesh Pasunuti;Renil Sabhadiya
    • Earthquakes and Structures
    • /
    • v.26 no.5
    • /
    • pp.349-361
    • /
    • 2024
  • Excessive torsional behaviour is one of the major reasons for failure of buildings, as inferred from past earthquakes. Numerous seismic codes across the world specify a displacement-based or drift-based criterion for classifying buildings as torsionally irregular. In recent years, quite a few researchers have pointed out some of the inherent deficiencies associated with the current codal guidelines on torsional irregularity. This short communication paper aims to envisage the need for a revision of the displacement-based guidelines on torsional irregularity, and further highlight the appropriateness of a rotation-based criterion. A set of 6 reinforced concrete building models with asymmetric shear walls are analysed using ETABS v18.0.2, by varying the number of stories from 1 to 9, and the torsional irregularity coefficient of various stories is calculated using the displacement-based formula. Since rotation about the vertical axis is a direct indication of the twist experienced by a building, the calculated torsional irregularity coefficients of all stories are compared with the corresponding floor rotations. The conflicting results obtained for the torsional irregularity coefficients are projected through five categories, namely mismatch with floor rotations, inconsistency in trend, lack of clarity in incorporation of negative values, sensitivity to low values of displacement and error conceived in the mathematical formulation. The findings indicate that the irregularity coefficient does not accurately represent the torsional behaviour of buildings in a realistic sense. The Indian seismic code-based values of 1.2 and 1.4, which are used to characterize buildings as torsionally irregular are observed to be highly sensitive to the numerical values of displacements, rather than the actual degree of rotation. The study thus emphasizes the revision of current guidelines based on a more relevant rotation-based or eccentricity-based approach.

A Study on the Properties of Ready Mixed Concrete Quality in Site by Statistical Analysis (통계분석에 의한 현장 타설 콘크리트의 품질 특성에 관한 연구)

  • Ji, Suk-Won;Jung, Si-Jin;Seo, Chee-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.5
    • /
    • pp.171-180
    • /
    • 2007
  • The quality of ready-mixed concrete(henceforth abbreviated remicon) is influenced by various factors such as ingredient of material, difference of property, mixing ratio, mixing time, mixing error, conditioning of construction, method of curing and temperature, humidity time in transportation. These factors make it hard to confirm the quality of remicon till placing in site. As the quality control in field is very important to ensure the quality of building. Moreover in modern building production, the more important the inquiry of performance improvement, the more important the manufacture and the quality control of remicon. In this study, to examine and analyze the quality of remicon we used slump, air content and compressive strength in 7, 28 days as to remicon which placed during on year. As a result, we found that the slump and air content were satisfied with reference code and the compressive strength was more than the design standard strength so we concluded that the quality control of remicon was to be agreeable.

Effects of Nursing Ethics Education on Moral Reasoning and Ethical Decision Making for Student Nurses (간호윤리 교육이 간호학생의 도덕적 사고와 윤리적 딜레마 상황에서의 의사결정에 미치는 효과)

  • Han, Sung-Suk;Ahn, Sung-Hee
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.1 no.2
    • /
    • pp.268-284
    • /
    • 1995
  • This study was designed to test effects of nursing ethics education (NEE) on moral reasoning and ethical decision making of subjects. This NEE that was teached for 10 hours course was composed of these : Nurses' ethical code, moral responsibility, Moral value and professional accountability, Respect for human life, General ethics, Theory and Norms of biomedical ethics, Ethical decision making model and Discussion about hypothetical ethical dilemmas Twenty-five senior student nurses were sampled from four year college of nursing from Nov. 3rd, 1993 to Nov. 24th, 1993. Data were collected through self-reported questionnaires included two kinds of tests. Rest's Defining Issues Test was adopted to measure the stage of moral development, which was classified with the stage 2 (instrumental relativist orientation), the stage 3 (interpersonal concordance), the stage 4 (law and order), the stage 5A (societal consensus), and the stage 5B (intuitional humanism), the stage 6 (universal ethical practice). In particular, the level of principled thinking (P) was measured by summing these scores of the stages 5A, 5B, and 6. The possible range of P is 0 to 95. As for measuring the levels of morality and nursing dilemma, Crisham's Nursing Dilemma Test was adopted. This test generated the morality score(MS) and the dilemma score (DS). The data were analyzed by t-test, ANOVA, Kruskal-Wallis test, Mc Nemar's test and Pearson correlation coefficients. The results were as follows ; 1. For the Moral Reasoning both before and after NEE, The Mean score of the stage 5A was significantly higher than that of other stages.(P=0.0001) Before NEE, the mean score of the stage 4 was significantly different from stage 2, 3, 5A, and after NEE, different from stage 2, 5B,6. 2. The analysis of change of moral development level revealed that the score of stage 4 increased after NEE.(P=0.0004) 3. The Effect of NEE for the mean score of 5A, 6, P after education was significantly different by birth place. 4. With regard to the five dilemmas postulated such as forcing medication performing cardiac pulmonary resuscitation, reporting a medication error, informing diagnosis to terminally ill adult, and providing new-nurse orientation, the mean score of the MS and the DS was no significant difference with general characteristics of the students. Effect of NEE morality score and dilemma score after education was no significant difference. 5. As for the correlations between moral reasoning and decision making, the score of the stage 2, 5A, 6, DS was positively correlated with the scores of before and after. Positive correlation was also observed between the scores of stage 2 and stage 4, stage 3 and 6. On the other hand, the score of P was negatively correlated with the scores of stage 2 and of stage 4 and of stage 5A. The score of the stage 5A was also negatively correlated with the score of the sge 6.

  • PDF

Study on CGM-LMS Hybrid Based Adaptive Beam Forming Algorithm for CDMA Uplink Channel (CDMA 상향채널용 CGM-LMS 접목 적응빔형성 알고리듬에 관한 연구)

  • Hong, Young-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.9C
    • /
    • pp.895-904
    • /
    • 2007
  • This paper proposes a robust sub-optimal smart antenna in Code Division Multiple Access (CDMA) basestation. It makes use of the property of the Least Mean Square (LMS) algorithm and the Conjugate Gradient Method (CGM) algorithm for beamforming processes. The weight update takes place at symbol level which follows the PN correlators of receiver module under the assumption that the post correlation desired signal power is far larger than the power of each of the interfering signals. The proposed algorithm is simple and has as low computational load as five times of the number of antenna elements(O(5N)) as a whole per each snapshot. The output Signal to Interference plus Noise Ratio (SINR) of the proposed smart antenna system when the weight vector reaches the steady state has been examined. It has been observed in computer simulations that proposed beamforming algorithm improves the SINR significantly compared to the single antenna case. The convergence property of the weight vector has also been investigated to show that the proposed hybrid algorithm performs better than CGM and LMS during the initial stage of the weight update iteration. The Bit Error Rate (BER) characteristics of the proposed array has also been shown as the processor input Signal to Noise Ratio (SNR) varies.

Development of a Portable Device Based Wireless Medical Radiation Monitoring System (휴대용 단말 기반 의료용 무선 방사선 모니터링 시스템 개발)

  • Park, Hye Min;Hong, Hyun Seong;Kim, Jeong Ho;Joo, Koan Sik
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.3
    • /
    • pp.150-158
    • /
    • 2014
  • Radiation-related practitioners and radiation-treated patients at medical institutions are inevitably exposed to radiation for diagnosis and treatment. Although standards for maximum doses are recommended by the International Commission on Radiological Protection (ICPR) and the International Atomic Energy Agency (IAEA), more direct and available measurement and analytical methods are necessary for optimal exposure management for potential exposure subjects such as practitioners and patients. Thus, in this study we developed a system for real-time radiation monitoring at a distance that works with existing portable device. The monitoring system comprises three parts for detection, imaging, and transmission. For miniaturization of the detection part, a scintillation detector was designed based on a silicon photomultiplier (SiPM). The imaging part uses a wireless charge-coupled device (CCD) camera module along with the detection part to transmit a radiation image and measured data through the transmission part using a Bluetooth-enabled portable device. To evaluate the performance of the developed system, diagnostic X-ray generators and sources of $^{137}Cs$, $^{22}Na$, $^{60}Co$, $^{204}Tl$, and $^{90}Sr$ were used. We checked the results for reactivity to gamma, beta, and X-ray radiation and determined that the error range in the response linearity is less than 3% with regard to radiation strength and in the detection accuracy evaluation with regard to measured distance using MCNPX Code. We hope that the results of this study will contribute to cost savings for radiation detection system configuration and to individual exposure management.

A Sensitivity Analysis of Design Parameters of an Underground Radioactive Waste Repository Using a Backpropagation Neural Network (Backpropagation 인공신경망을 이용한 지하 방사성폐기물 처분장 설계 인자의 민감도 분석)

  • Kwon, S.;Cho, W.J.
    • Tunnel and Underground Space
    • /
    • v.19 no.3
    • /
    • pp.203-212
    • /
    • 2009
  • The prediction of near field behavior around an underground high-level radioactive waste repository is important for the repository design as well as the safety assessment. In this study, a sensitivity analysis for seven parameters consisted of design parameters and material properties was carried out using a three-dimensional finite difference code. From the sensitivity analysis, it was found that the effects of borehole spacing, tunnel spacing, cooling time and rock thermal conductivity were more significant than the other parameters. For getting a statistical distribution of buffer and rock temperatures around the repository, an artificial neural network, backpropagation, was applied. The reliability of the trained neural network was tested with the cases with randomly chosen input parameters. When the parameter variation is within ${\pm}10%$, the prediction from the network was found to be reliable with about a 1% error. It was possible to calculate the temperature distribution for many cases quickly with the trained neural network. The buffer and rock temperatures showed a normal distribution with means of $98^{\circ}C$ and $83.9^{\circ}C$ standard deviations of $3.82^{\circ}C$ and $3.67^{\circ}C$, respectively. Using the neural network, it was also possible to estimate the required change in design parameters for reducing the buffer and rock temperatures for $1^{\circ}C$.

Finite Element Analysis in Finite Length Bar under Constant Amplitude Loading (일정진폭하중을 받는 유한 길이 봉의 유한요소해석)

  • Hwang, Eun-Ha
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.5
    • /
    • pp.525-533
    • /
    • 2010
  • Direct time integration method such as Newmark method is numerically performed under the assumption that continuous load function such as constant amplitude load can be treated as a discontinuous load fuction. It is due that the load can be treated as a constant value at the given time period regardless of variation of load at the time increment interval. It means the numerical results should be accompanied by the error due to approximation of load fuction. In contrast, the load function is calculated by convolution integral for the given time interval at finite element equation based on Gurtin's variation equation. Therefore. precise numerical results can be obtained by Gurtin's method because of convolution integral for the continuous load fuction curve even at the variation of load function in the given time interval. In this study, we prove that Gurtin's method can be more suitable than Newmark method in the problem of constant amplitude loading, using the numerical results for the free end of the one-dimensional rod. This study also shows that Gurtin's method is more effective in constant amplitude loading than in constant loading. The accuracy and the validity are verified by comparison between the results of in-house FORTRAN code and ADINA, a commercial software supporting Newmark method.

Study of Radiation dose Evaluation using Monte Carlo Simulation while Treating Extrahepatic Bile Duct Cancer with High Dose Rate Intraluminal Brachytherapy (간외 담도암 고선량률 관내근접방사선치료 시 몬테카를로 시뮬레이션을 통한 주변장기의 선량평가 연구)

  • Park, Ju-Kyeong;Lee, Seung-Hoon;Cha, Seok-Yong;Lee, Sun-Young
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.2
    • /
    • pp.467-474
    • /
    • 2014
  • The relative dose calculated by MCNPX and the relative dose measured by ionization chamber and solid phantoms evaluated the accuracy comparing with Monte Carlo simulation. In order to apply Monte Carlo simulation the intraluminal brachytherapy of extrahepatic bile duct cancer, 192Ir sealed radioactive source replicate, Bile duct and surrounding organs were made using KMIRD phantom based on a South Korea standard man. To check the absorbed dose of normal organs around bile duct, we set the specific effective energy and initial radioactivity to 1 Ci using MCNPX. Evaluation of the accuracy of the Monte Carlo simulation, the difference of the relative dose is the most 1.96% that satisfy the criteria that is the relative error less than 2% suggested by MCNPX code. In addition, The specific effective energy and absorbed dose of normal organs that were relatively adjacent to bile duct such as right side of kidney, liver, pancreas, transverse colon, spinal cord, stomach and small intestine were relatively high. on the contrary, the organs that were relatively distant to bile duct such as left side of kidney, spleen, ascending colon, descending colon and sigmoid colon were relatively low.

A study on the optimization technique for the plan of slope reinforcement arrangement of soil-nailing in tunnel portal area (터널 갱구사면 쏘일네일링 보강배치계획을 위한 최적화기법 연구)

  • Kim, Byung-Chan;Moon, Hyun-Koo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.18 no.6
    • /
    • pp.569-579
    • /
    • 2016
  • In order to ensure the stability of tunnel portal slope, reinforcement method such as anchors, soil nails and rock bolts have been used in Korea. When selecting slope reinforcement methods in tunnel portal area such as reinforcement arrangement and length, trial and error method can be very time-consuming and it was also not easy to verify the selection of an optimum condition. In this study, using the FISH language embedded in the finite difference code FLAC3D program, the optimization technique was developed with the Differential Evolution Algorithm (DEA). After building a database on the soil nailing method in tunnel portal area, this system can be selected to an optimum arrangement plan based on the factor of safety through the FLAC3D analysis. Through the results of numerical analysis, it was confirmed that the number of analysis was decreased by about 8 times when DEA based optimization technique was used compared to the full combination (FC). In case of the design of slope reinforcement in tunnel portal area, if this built-system is used, it is expected that the selection of an optimum arrangement plan can be relatively easier.