• Title/Summary/Keyword: equivalent thickness

Search Result 605, Processing Time 0.026 seconds

Finite Element Analysis on the Displacement Behavior Safety of Hollow Shafts with Equivalent Volume (동등체적을 갖는 중공축의 변위거동 안전성에 관한 유한요소해석)

  • Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.3
    • /
    • pp.73-77
    • /
    • 2016
  • This paper presents the displacement behavior safety of hollow shafts with an equivalent volume for various cross sectional area using a finite element method. The FEM results indicate that the hollow shafts with X-type or Y-type columns between outer tube, middle tube and inner tube may reduce a maximum displacement at the middle length of hollow shafts. Especially, the load-bearing column of X-type or Y-type hollow shaft is directly connected between outer tube and inner tube without a shift for reducing the vertical displacement. And increased thickness of a load-bearing column is recommended for reducing the vertical displacement and increasing the displacement behavior safety for an equivalent volume of a hollow shaft.

Preliminary Results of Tissue-Equivalent Proportional Counter (TEPC) Dosimeter for Measuring In-Situ Aviation Radiation

  • Nam, Uk-won;Park, Won-kee;Hwang, Junga;Sohn, Jongdae;Moon, Bongkon;Kim, Sunghwan
    • Journal of Astronomy and Space Sciences
    • /
    • v.37 no.4
    • /
    • pp.249-255
    • /
    • 2020
  • We develop the tissue-equivalent proportional counter (TEPC) type's space radiation dosimeter to measure in-situ aviation radiation. That was originally developed as a payload of small satellite in the low-earth orbit. This dosimeter is based on a TEPC. It is made of an A-150 tissue-equivalent plastic shell of an internal diameter of 6 cm and a thickness of 0.3 cm. TEPC is filled with pure propane at 13.9 torrs to simulate a cell diameter of 2 ㎛. And the associated portable and low power electronics are also implemented. The verification experiments have been performed by the calibration experiments at ground level and compared with Liulin observation at aircraft altitude during the flight between Incheon airport (ICN) and John F. Kennedy airport (JFK). We found that the TEPC dosimeter can be used as a monitor for space radiation dosimeter at aviation altitude based on the verification with Liulin observation.

Evanescent-Mode Analysis of Short-Channel Effects in MOSFETs (Evanescent-Mode를 이용한 MOSFET의 단채널 효과 분석)

  • 이지영;신형순
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.10
    • /
    • pp.24-31
    • /
    • 2003
  • Short channel effects (SCE) of bulk MOSFET with super-steep retrograded channels (SSR), fully-depleted SOI, and double-gate MOSFET have been analyzed using a evanescent-mode analysis. Analytical equations of the characteristics scaling-length (λ) for three structures have been derived and the accuracy of the calculated λ was verified by comparing to the device simulation result. It is found that the minimum channel length should be larger than 5λ and the depletion thickness of the SSR should be around 30 nm in order to be applicable to 70 nm CMOS technology. High-$textsc{k}$ dielectric shows a limitation in scaling due to the drain-field penetration through the dielectric unless the equivalent SiO2 thickness is very thin.

Development of Doubler Design System for Ship Plate Members Subjected to In-plane Shear and Biaxial Compressive Loads (면내 전단하중과 양축압축하중을 받는 선박 판부재의 이중판 설계시스템 개발)

  • Ham, Juh-Hyeok
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.54 no.3
    • /
    • pp.242-249
    • /
    • 2017
  • A design system for doubler reinforcement of the ship plate members subjected to in-plane shear and biaxial compressive loads was developed. This design system of doubler reinforcement on ship plate members established by design supporting system and this system was based on the buckling evaluation process of ship plate members for these in-plane loads. Each design parameters were suggested by equations as the form of influence coefficients for the doubler reinforcement subjected to the various in-plane loads including shear load. Strength of doubler plate member reinforced on the plate member could be suggested by the equivalent flat plate thickness after the consideration of corelation equations in the design system of doubler reinforcement. Level of strength recovery of ship plate members for these in-plane loads according to the local reinforcement by doubler could be suggested by use of this design system in the initial repair design stage of shipyards.

Analysis of the Chip Shape in Turing (I) -Analysis of the Chip Flow Angle- (선삭가공의 칩형상 해석 (I) -칩흐름각 해석-)

  • 이영문;최수준;우덕진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.1
    • /
    • pp.139-144
    • /
    • 1991
  • Chip flow angle is one of the important factors to be determined for the scheme of Chip Control. Up to now, however, a dependable way to predict the chip flow angle in practical cutting has not been established satisfactorily. In this paper a rather simple theoretical prediction of chip flow angle is tried based on some already widely confirmed hypotheses. The developed equation of chip flow angle contains the parameters of depth of cut d, feed rate f, nose radius $r_{n}$ side cutting edge angle $C_{s}$, side rake angle .alpha.$_{s}$ and back rake angle .alpha.$_{b}$. Theoretical results of chip flow angle given by this study bas been shown in a good agreement with experimental ones.s.s.s.s.

Magneto-thermo-elastic response of a rotating functionally graded cylinder

  • Hosseini, Mohammad;Dini, Ali
    • Structural Engineering and Mechanics
    • /
    • v.56 no.1
    • /
    • pp.137-156
    • /
    • 2015
  • In this paper, an analytical solution of displacement, strain and stress field for rotating thick-walled cylinder made of functionally graded material subjected to the uniform external magnetic field and thermal field in plane strain state has been studied. Stress, strain and displacement field as a function of radial coordinates considering magneto-thermo-elasticity are derived analytically. According to the Maxwell electro-dynamic equations, Lorentz force in term of displacement is obtained in cylindrical coordinates. Also, symmetric temperature distribution along the thickness of hollow cylinder is obtained by solving Fourier heat transfer equation in cylindrical coordinates. Using equation of equilibrium and thermo-mechanical constitutive equations associated with Lorentz force, a second-order inhomogeneous differential equation in term of displacement is obtained and will be solved analytically. Except Poisson's ratio, other mechanical properties such as elasticity modulus, density, magnetic permeability coefficient, heat conduction coefficient and thermal expansion coefficient are assumed to vary through the thickness according to a power law. In results analysis, non-homogeneity parameter has been chosen arbitrary and inner and outer surface of cylinder are assumed to be rich metal and rich ceramic, respectively. The effect of rotation, thermal, magnetic field and non-homogeneity parameter of functionally graded material which indicates percentages of cylinder's constituents are studied on displacement, Von Mises equivalent stress and Von Mises equivalent strain fields.

A laminated composite plate finite element a-priori corrected for locking

  • Filho, Joao Elias Abdalla;Belo, Ivan Moura;Pereira, Michele Schunemann
    • Structural Engineering and Mechanics
    • /
    • v.28 no.5
    • /
    • pp.603-633
    • /
    • 2008
  • A four-node plate finite element for the analysis of laminated composites which is developed using strain gradient notation is presented. The element is based on a first-order shear deformation theory and on the equivalent lamina assumption. Strains and stresses can be calculated at different points through the thickness of the plate. They are averaged values due to the equivalent lamina assumption. A shear correction factor is used as the transverse shear strain is taken to be constant over the plate thickness while its actual variation is parabolic. Strain gradient notation, which is physically interpretable, allows for the detailed a-priori analysis of the finite element model. The polynomial expansions are inspected and spurious terms responsible for modeling errors are identified in the shear strains polynomial expansions. The element is corrected by simply removing the spurious terms from the shear strains expansions. The element is implemented into a FORTRAN finite element code in two versions; namely, with and without spurious terms. Results are compared to show the effects of the spurious terms on the solutions. It is also shown that a refined mesh composed of corrected elements provides solutions which approximate very well the analytical solutions, validating the procedure.

Implementation of Nano-Scale Grating-Assisted Coupler with Polarization-Insensitivity using Double-Sandwiched Guide (이중 샌드위치 도파로를 사용한 편광 무의존성 특성을 갖는 나노크기 격자 구조형 결합기의 구현)

  • Ho, Kwang-Chun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.2
    • /
    • pp.221-227
    • /
    • 2015
  • The polarization characteristics of nano-scale grating-assisted polarization-insensitive coupler (GA-PIC) consisted of double sandwiched rib-type layers are evaluated in detail by using modal transmission-line theory (MTLT) based on equivalent network. To obtain the polarization-insensitive condition of GA-PIC, the coupling lengths as a function of the refractive index and thickness of sandwiched rib-type layer as well as the grating thickness and period are analyzed for quasi-TE and quasi-TM modes. The numerical results show that the GA-PIC with hundreds of nanometer scale is realized by properly choosing structural and material parameters of double sandwiched layers and grating.

Conjugate Natural Convection in Double Enclosed Annuli Between Horizontal Concentric Cylinders (水平 同心圓二重 環狀密閉 空間에서의 Conjugate 自然對流 熱傳達)

  • 손병진;강희영
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.4
    • /
    • pp.430-439
    • /
    • 1985
  • Conjugate natural convection in double enclosed annuli between horizontal concentric cylinders has been studied by the numerical analysis and experimental measurements. The interface conditions between the liquid and the solid of middle shell are obtained through the correlation factor based on the ratio of solid to fluid thermal conductivities and the Prandtl number. The characteristics of conjugate heat transfer are discussed under various dimensionless parameters such as conductivity ratios, shell thickness, diameter ratios, Prandtl number, and Rayleigh number. It is found that the average equivalent conductivity K over var $_{eq}$ does not depend on the conductivity ratios and shell thickness. The K over bar $_{eq}$ however, depends on the Prandtl number and the Rayleigh number.

Determination of Preheating Temperature for Box Girder Welding (강교용 박스거더의 용접예열 온도 선정에 관한 연구)

  • Cho, Jae-Hun;Moon, Seung-Jae;Yoo, Hoseon
    • Plant Journal
    • /
    • v.7 no.1
    • /
    • pp.49-55
    • /
    • 2011
  • This study analyzed causes and status of cracks to suggest preventives for welding cracks generated on fillet welding zone of atmosphere corrosion resisting steel box girder. Penetrant testing, a sort of non-destructive testing, was conducted for inspection of crack status on welding zone. As a result of test, welding cracks were found on the point of start, center and end to fillet welding zone of 32 mm-thickness. The result of carbon equivalent composition of materials was 0.452%. According to welding specification, to preheat prevent welding crack, preheat temperature of $100{\sim}200^{\circ}C$ should be kept before welding execution. It was failed to keep preheat temperature because it had been executed on winter season and the structure of box girder had wide heat transfer area. As a result of examination of time varying preheating temperature of 32mm-thickness material, it was understood that preheat temperature of above $230^{\circ}C$ on both 130mm-long sides of welded joint can prevent welding crack.

  • PDF