Preliminary Results of Tissue-Equivalent Proportional Counter (TEPC) Dosimeter for Measuring In-Situ Aviation Radiation  

Nam, Uk-won (Korea Astronomy and Space Science Institute)
Park, Won-kee (Korea Astronomy and Space Science Institute)
Hwang, Junga (Korea Astronomy and Space Science Institute)
Sohn, Jongdae (Korea Astronomy and Space Science Institute)
Moon, Bongkon (Korea Astronomy and Space Science Institute)
Kim, Sunghwan (Department of Radiology, Cheongju University)
Publication Information
Journal of Astronomy and Space Sciences / v.37, no.4, 2020 , pp. 249-255 More about this Journal
Abstract
We develop the tissue-equivalent proportional counter (TEPC) type's space radiation dosimeter to measure in-situ aviation radiation. That was originally developed as a payload of small satellite in the low-earth orbit. This dosimeter is based on a TEPC. It is made of an A-150 tissue-equivalent plastic shell of an internal diameter of 6 cm and a thickness of 0.3 cm. TEPC is filled with pure propane at 13.9 torrs to simulate a cell diameter of 2 ㎛. And the associated portable and low power electronics are also implemented. The verification experiments have been performed by the calibration experiments at ground level and compared with Liulin observation at aircraft altitude during the flight between Incheon airport (ICN) and John F. Kennedy airport (JFK). We found that the TEPC dosimeter can be used as a monitor for space radiation dosimeter at aviation altitude based on the verification with Liulin observation.
Keywords
space radiation; tissue-equivalent proportional counter (TEPC) dosimeter; aviation radiation;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Chang SY, Kim BH, Understanding of the microdosimetric quantities obtained by a TEPC, J. Nucl. Sci. Technol. 45, 213-216 (2008). https://doi.org/10.1080/00223131.2008.10875825   DOI
2 Dachev T, Dimitrov P, Tomov B, Matviichuk Y, Technical description of the spectrometer-dosimeter Liulin-6C MDU-6, Solar-Terrestrial Influences Laboratory, Bulgarian Academy of Science (2009).
3 Dachev T, Tomov B, Matviichuk Y, Dimitrov P, Lemaire J, et al., Calibration results obtained with Liulin-4 type dosimeters, Adv. Space Res. 30, 917-925 (2002). https://https://doi.org/10.1016/S0273-1177(02)00411-8   DOI
4 International Commission on Radiological Protection [ICRU], 1990 Recommendations of the International Commission on Radiological Protection, ICRP Publication 60 (1991).
5 Latocha M, Real time radiation dose assessment at civil flight altitudes due to galactic cosmic rays and spontaneous, PhD Dissertation, Institute of Nuclear Physics, Polish Academy of Sciences (2017).
6 Lindborg L, Kyllonen JE, Beck P, Bottollier-Depois JF, Gerdung S, et al., The use of TEPC for reference dosimetry, Radiat. Prot. Dosimetry. 86, 285-288 (1999). https://doi.org/10.1093/oxfordjournals.rpd.a032959   DOI
7 Malimban J, Nam UW, Pyo J, Youn S, Ye SJ, Characterization of a new tissue equivalent proportional counter for dosimetry of neutron and photon fields: comparison of measurements and Monte Carlo simulations, Phys. Med. Biol. 64, 17NT02 (2019). https://doi.org/10.1088/1361-6560/ab2f1f   DOI
8 Meier MM, Matthia D, Forkert T, Wirtz M, Scheibinger M, et al., RaD-X:Complementary measurements of dose rates at aviation altitudes, Space Weather 14, 689-694 (2016). https://doi.org/10.1002/2016SW001418   DOI
9 Aslam, Prestwich WV, McNeill FE, Waker AJ, Investigating the TEPC radiation quality factor response for low energy accelerator based clinical applications, Radiat. Prot. Dosim. 103, 311-322 (2003). https://doi.org/10.1093/oxfordjournals.rpd.a006148   DOI
10 Booz J, Braby L, Coyne J, Kliauga P, Lindborg L, et al., Microdosimetry, J. ICRU. os19, NP (1983). https://doi.org/10.1093/jicru/os19.1.Report36   DOI
11 Nam UW, Park WK, Lee J, Pyo J, Moon BK, et al., Calibration of TEPC for CubeSat experiment to measure space radiation, J. Astron. Space Sci. 32, 145-149 (2015). https://doi.org/10.5140/JASS.2015.32.2.145   DOI
12 Rollet S, Beck P, Ferrari A, Pelliccioni M, Autischer M, Dosimetric considerations of TEPC FLUKA-simulation and measurements, Radiat. Prot. Dosimetry, 110, 833-7 (2004). https://doi.org/10.1093/rpd/nch106   DOI
13 Straume T, Mertens CJ, Lusby TC, Gersey B, Tobiska WK, et al., Ground-based evaluation of dosimeters for NASA high-altitude balloon flight, Space Weather 14, 1011-1025 (2016). https://doi.org/10.1002/2016SW001406   DOI