Preliminary Results of Tissue-Equivalent Proportional Counter (TEPC) Dosimeter for Measuring In-Situ Aviation Radiation |
Nam, Uk-won
(Korea Astronomy and Space Science Institute)
Park, Won-kee (Korea Astronomy and Space Science Institute) Hwang, Junga (Korea Astronomy and Space Science Institute) Sohn, Jongdae (Korea Astronomy and Space Science Institute) Moon, Bongkon (Korea Astronomy and Space Science Institute) Kim, Sunghwan (Department of Radiology, Cheongju University) |
1 | Chang SY, Kim BH, Understanding of the microdosimetric quantities obtained by a TEPC, J. Nucl. Sci. Technol. 45, 213-216 (2008). https://doi.org/10.1080/00223131.2008.10875825 DOI |
2 | Dachev T, Dimitrov P, Tomov B, Matviichuk Y, Technical description of the spectrometer-dosimeter Liulin-6C MDU-6, Solar-Terrestrial Influences Laboratory, Bulgarian Academy of Science (2009). |
3 | Dachev T, Tomov B, Matviichuk Y, Dimitrov P, Lemaire J, et al., Calibration results obtained with Liulin-4 type dosimeters, Adv. Space Res. 30, 917-925 (2002). https://https://doi.org/10.1016/S0273-1177(02)00411-8 DOI |
4 | International Commission on Radiological Protection [ICRU], 1990 Recommendations of the International Commission on Radiological Protection, ICRP Publication 60 (1991). |
5 | Latocha M, Real time radiation dose assessment at civil flight altitudes due to galactic cosmic rays and spontaneous, PhD Dissertation, Institute of Nuclear Physics, Polish Academy of Sciences (2017). |
6 | Lindborg L, Kyllonen JE, Beck P, Bottollier-Depois JF, Gerdung S, et al., The use of TEPC for reference dosimetry, Radiat. Prot. Dosimetry. 86, 285-288 (1999). https://doi.org/10.1093/oxfordjournals.rpd.a032959 DOI |
7 | Malimban J, Nam UW, Pyo J, Youn S, Ye SJ, Characterization of a new tissue equivalent proportional counter for dosimetry of neutron and photon fields: comparison of measurements and Monte Carlo simulations, Phys. Med. Biol. 64, 17NT02 (2019). https://doi.org/10.1088/1361-6560/ab2f1f DOI |
8 | Meier MM, Matthia D, Forkert T, Wirtz M, Scheibinger M, et al., RaD-X:Complementary measurements of dose rates at aviation altitudes, Space Weather 14, 689-694 (2016). https://doi.org/10.1002/2016SW001418 DOI |
9 | Aslam, Prestwich WV, McNeill FE, Waker AJ, Investigating the TEPC radiation quality factor response for low energy accelerator based clinical applications, Radiat. Prot. Dosim. 103, 311-322 (2003). https://doi.org/10.1093/oxfordjournals.rpd.a006148 DOI |
10 | Booz J, Braby L, Coyne J, Kliauga P, Lindborg L, et al., Microdosimetry, J. ICRU. os19, NP (1983). https://doi.org/10.1093/jicru/os19.1.Report36 DOI |
11 | Nam UW, Park WK, Lee J, Pyo J, Moon BK, et al., Calibration of TEPC for CubeSat experiment to measure space radiation, J. Astron. Space Sci. 32, 145-149 (2015). https://doi.org/10.5140/JASS.2015.32.2.145 DOI |
12 | Rollet S, Beck P, Ferrari A, Pelliccioni M, Autischer M, Dosimetric considerations of TEPC FLUKA-simulation and measurements, Radiat. Prot. Dosimetry, 110, 833-7 (2004). https://doi.org/10.1093/rpd/nch106 DOI |
13 | Straume T, Mertens CJ, Lusby TC, Gersey B, Tobiska WK, et al., Ground-based evaluation of dosimeters for NASA high-altitude balloon flight, Space Weather 14, 1011-1025 (2016). https://doi.org/10.1002/2016SW001406 DOI |