• 제목/요약/키워드: equivalent test

검색결과 1,960건 처리시간 0.035초

등가 종 모델을 이용한 맥놀이 조절법 (Beat Control Using an Equivalent Ring Model)

  • 김석현;이중혁
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.516-519
    • /
    • 2012
  • This study proposes a method of an equivalent bell model in order to tune the beat period of a Korean bell. In a Korean bell having a slight asymmetry, each circumferential mode splits into a mode pair which has a slight difference in frequency, and the interaction of the mode pair makes a beat in vibration and sound. An equivalent bell model which consists of an axi-symmetric bell and an equivalent point mass, has the same mode property as in a real bell. The equivalent bell model is constructed by the finite element analysis based upon the theory of a revolutionary shell Using the equivalent bell model, the beat period is predicted when the bell thickness is locally decreased to improve the beat property. The predicted result is verified by experiment on a test bell. The proposed method is useful to save the time required for tuning the beat period of a large bell.

  • PDF

시판 이소니아짓 정제의 생물학적 동등성시험에 관한 연구 (Studies on the Bioequivalence Test of Isoniazid Tablets)

  • 최준식;안선엽
    • 약학회지
    • /
    • 제33권4호
    • /
    • pp.229-236
    • /
    • 1989
  • Even though two different preparations are chemically equivalent, the variance of bioavailability differenciates the clinical effect of preparations, so that the preparations need to be evaluated by comparing bioavailability in vivo as well as chemical equivalence. In this study, bioequivalence tests of commercially available isoniazid tablets A, B, C and D (standard) were performed to give some guidelines to bioequivalence test. The bioavailability parameters obtained by drug administeration were statistically analyzed. Statistical evaluation of the data involved an analysis of variance for a cross over design. Cross over design was employed with 8 healthy volunteers. The results were within 20% difference of mean value in the AUC, Cmax, Tmax and amount of urinary excretion (Au) between standard and isoniazid tablets. The results of ANOVA showed no significant differences for 'group or sequence', but almost not for 'between subjects'. The tablet. A, B and D were within 20 min, but tablet C was within 50 min. Tablet A was biologically equivalent in the Au. tablet B biologically equivalent in the Au and AUC. Tablet C was biologically equivalent in the Au. The relationship between the dissolution rate and Au was significant.

  • PDF

등가변형을 이용한 테이터 말뚝의 지지력 산정 (Estimation of Axial toad Capacity for Tapered Piles Using Equivalent Transformation)

  • 전성남;서경범;송원준;이준환
    • 한국지반공학회논문집
    • /
    • 제25권8호
    • /
    • pp.57-64
    • /
    • 2009
  • 본 연구에서는 등가변형을 이용하며 테이퍼 말뚝의 지지력을 산정하는 방법을 제안하였다. 지반조건과 테이퍼각도를 고려하여 지지력을 산정하던 기존의 방법과 달리, 테이퍼말뚝의 지지력산정시 콘관입시험 결과를 활용하도록 하였다. 이때 테이퍼말뚝은 등가변형을 이용하여 형태를 단순화 시켰으며 이를 통해 실무에서 비교적 쉽게 지지력을 산정 할 수 있는 방법을 제안하였다. 제안된 방법의 검증을 위해 실내시험과 현장시험을 실시하였다. 실내모형시험 결과로부터 측정된 극한지지력과 본 연구에서 제안된 방법에 의한 예측값을 비교한 결과 표준편차는 $0.05{\sim}0.121$, COV는 $0.04{\sim}0.05$의 값을 보여 대체적으로 유사한 결과를 보였으며, 현장시험은 약 2.5%의 오차를 보여 측정값에 근접함을 알 수 있었다. 그 결과 제안된 지지력 산정법은 테이퍼말뚝의 지지력을 비교적 정확하게 예측하는 것으로 나타났다.

RC 축소모형의 유사동적실험을 위한 Equivalent Multi-Phase Similitude Law (An Equivalent Multi-Phase Similitude Law for Pseudodynamic Test on Small-scale RC Models)

  • 김남식;이지호;장승필
    • 한국지진공학회논문집
    • /
    • 제7권6호
    • /
    • pp.101-108
    • /
    • 2003
  • 실험장비의 용량 제약, 경제적인 이유 등으로 지진하중에 대한 구조물의 동적 거동을 연구할 경우, 보편적으로 축소모형이 많이 적용되고 있다. 그러나 구조물의 지진응답은 비탄성 거동을 나타내기 때문에 거동예측이 복잡함에도 불구하고, 축소모형의 지진실험 결과로부터 원형구조물의 지진응답을 유추하기 위한 상사법칙의 연구는 미비한 실정이다. RC구조물의 축소모형 제작 시 상사율이 커지면 상대적으로 부가질량이 증가하며, 또한 굵은 골재 크기의 영향으로 원형구조물과 축소모형의 제작에 동일한 재료를 사용하지 않는 것이 바람직하다. 따라서 동일한 재료를 사용하지 않을 경우, 상사법칙은 기하학적인 상사율과 재료적인 등가탄성계수비에 의존하게 된다. 본 연구에서는 원형구조물과 축소모형에 각각 적용되는 normal-concrete와 micro-concrete의 재료 비선형성을 파악하기 위해 압축강도시험을 수행하여, 재료의 거동구간을 등가의 다단계로 나누어 등가탄성계수비를 적용시킴으로써 지진손상의 정도를 고려할 수 있는 Equivalent multi-phase similitude law를 유도하였다. 이러한 상사법칙을 적용한 유사동적실험 알고리즘을 구축하여 수치해석적인 검증을 수행하여 유사동적실험의 적용성을 확인하였다.

주파수 변화에 따른 5상 농형 유도전동기의 정수 추정 (Parameters Estimation of Five-Phase Squirrel-Cage Induction Motor in Changing Variable Frequency)

  • 김민희
    • 전기학회논문지P
    • /
    • 제63권4호
    • /
    • pp.241-247
    • /
    • 2014
  • This paper propose a variable parameter estimations of five-phase squirrel-cage induction motor(IM) for speed control system. In order to high performance control of AC motor using a field oriented control(FOC) and direct torque control(DTC) algorithm, there are required precise motor parameters for slip calculation, flux observer, controller gain, rotor position, speed estimation, and so on. We are suggest a analyzed estimation results of the motor parameters that developing five-phase squirrel-cage IM have a stator of concentrated winding for experimental of variable input power frequency. There are results of stator winding test, no-load test, locked-rotor test, variable actual load test, and estimated parameters of equivalent circuits using manufactured experimental apparatus by IEEE Standard Test Procedure for Polyphase Induction Motors and Generators 112-2004.

Dynamic equivalent model of a SMART control rod drive mechanism for a seismic analysis

  • Ahn, Kwanghyun;Lee, Jae-Seon
    • Nuclear Engineering and Technology
    • /
    • 제52권8호
    • /
    • pp.1834-1846
    • /
    • 2020
  • The SMART (System-integrated Modular Advanced ReacTor) is an integral-type small modular reactor developed by KAERI (Korea Atomic Energy Research Institute). This paper discusses the development of a dynamic equivalent model of the SMART control rod drive mechanism that can be efficiently utilized for complicated analysis during the design of the SMART. A semi-empirical approach is used to develop the equivalent model; that is, the equivalent model is defined analytically and verified empirically. Two types of tests, dynamic characteristics tests and seismic loading tests, are conducted for the development and verification of the dynamic equivalent model, respectively. Acceleration response spectra from the seismic analysis based on the developed equivalent model show good agreement with those from the seismic loading tests.

전력계통 과도현상 해석을 위한 상영역에서의 등가축약 기법 (A Phase-Domain Equivalent Representation for Electromagnetic Transients Studies)

  • 정병태;김성희;허성일;안복신;홍준희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.731-733
    • /
    • 1996
  • In this paper, a new time-domain reduction method for unbalanced 3 phase power systems will be represented. The impulse response of the system is used to identify a discrete-time equivalent filter model. The model is formulated directly in the phase domain. Each phase has a self-mode equivalent model and two mutual-mode equivalent models. The equivalent model is determined by the transfer function identification technique based on the Prony analysis. The model is implemented in EMTDC and tested with an unbalanced 3 phase network. The result of test showed that the equivalent model is accurate.

  • PDF

Modified Equivalent Radius Approach for Soil Damping Measurement in Torsional Testing

  • Bae, Yoon-Shin
    • 한국방재학회 논문집
    • /
    • 제8권2호
    • /
    • pp.39-43
    • /
    • 2008
  • Determination of strain associated with shear modulus and damping ratio during torsional test is complicated. This is due to nonuniform stress-strain variation occurring linearly with radius in a soil specimen in torsion. A conventional equivalent radius approach proposed by Chen and Stokoe appears to be adequate for evaluating strain associated with shear modulus at low to intermediate strain levels. This approach is less accurate for damping measurement, particularly at high strain. Modified equivalent radius approach was used to account for the nonuniform stress-strain effect more precisely. The modified equivalent radius approach was applied for hyperbolic, modified hyperbolic, and Ramberg-Osgood models. The results illustrate the usefulness of the modified equivalent radius approach and suggest that using a single value of equivalent radius ratio to calculate strains is not appropriate.

가진입력의 크기에 따른 동조액체기둥감쇠기의 비선형 특성 (Nonlinear Characteristic of a Tuned Liquid Column Damper under Various Excitation Amplitudes)

  • 이성경;이혜리;민경원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 추계학술대회 논문집
    • /
    • pp.842-849
    • /
    • 2009
  • The objective of this study is to investigate design parameters of a tuned liquid column damper(TLCD), which is affected by various excitation amplitudes, through shaking table test. Design parameters of a TLCD are examined based on the equivalent tuned mass damper(TMD) model of a TLCD, in which the nonlinear damping of a TLCD is transposed to equivalent viscous damping. Shaking table test is carried out for a TLCD specimen subjected to harmonic waves with various amplitudes. Transfer functions are ratios of liquid displacement of TLCD and control force produced by a TLCD, respectively, with respect to the acceleration excited by a shaking table. They are derived based on the equivalent TMD model of a TLCD. Then, the variation of design parameters according to the excitation amplitude is examined by comparing analytical transfer functions with experimental ones. Finally, the dissipation energy due to the damping of a TLCD, which is experimentally observed from the shaking table test, is examined according to the excitation amplitude. Comparisons between test results and analytical transfer functions showed that natural frequencies of TLCD and the ratio of the liquid mass in a horizontal column to the total liquid mass does not depend on the excitation amplitude, while the damping ratio of a TLCD increases with larger excitation amplitudes.

  • PDF

가진입력의 크기에 따른 동조액체기둥감쇠기의 비선형 특성 (Nonlinear Characteristic of a Tuned Liquid Column Damper under Various Excitation Amplitude)

  • 이성경;이혜리;민경원
    • 한국소음진동공학회논문집
    • /
    • 제19권11호
    • /
    • pp.1167-1176
    • /
    • 2009
  • The objective of this study is to investigate design parameters of a tuned liquid column damper(TLCD), which is affected by various excitation amplitude, through shaking table test. Design parameters of a TLCD are examined based on the equivalent tuned mass damper(TMD) model of a TLCD, in which the nonlinear damping of a TLCD is transposed to equivalent viscous damping. Shaking table test is carried out for a TLCD specimen subjected to harmonic waves with various amplitude. Transfer functions are ratios of liquid displacement of TLCD and control force produced by a TLCD, respectively, with respect to the acceleration excited by a shaking table. They are derived based on the equivalent TMD model of a TLCD. Then, the variation of design parameters according to the excitation amplitude is examined by comparing analytical transfer functions with experimental ones. Finally, the dissipation energy due to the damping of a TLCD, which is experimentally observed from the shaking table test, is examined according to the excitation amplitude. Comparisons between test results and analytical transfer functions showed that natural frequencies of TLCD and the ratio of the liquid mass in a horizontal column to the total liquid mass do not depend on the excitation amplitude, while the damping ratio of a TLCD increases with larger excitation amplitude.