• Title/Summary/Keyword: equivalent source

Search Result 579, Processing Time 0.025 seconds

Analysis of Electro-magnetic Wave radiating from an Ignition Plug and High-voltage Cable inside an Engine Room (자동차의 점화 플러그와 고압 케이블에서 발생하는 전자파에 대한 해석)

  • 최광제;조시기;정원락;장성국;강신한
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.1
    • /
    • pp.209-215
    • /
    • 2004
  • This paper presents the frequency range and an analysis method to find the dominant source of electro-magnetic wave which originates from a spark ignition in engine room. Applying the distributed constant equivalent circuit theory the radiation of probable electro-magnetic wave around an ignition plug and a high voltage cable is studied analytically. Experimental studies are also conducted by measuring the frequency spectrum to obtain the radiating characteristics of electro-magnetic wave. Results from both analytical and experimental studies confirm that an ignition plug and a high voltage cable are dominant sources of electro-magnetic wave and that the radiating frequency is ranged from 1.3[GHz] to 2[GHz] band.

A Study of Barrier Insertion Loss Near a High Rise Building (고층 건물에 인접한 방음벽의 삽입손실에 관한 연구)

  • 진병주;김현실;김상렬
    • Journal of KSNVE
    • /
    • v.10 no.1
    • /
    • pp.49-56
    • /
    • 2000
  • In this paper performance of the noise barrier which is 53 m long and 6m high, and is located between the high rise apartment and road, is studied by using experimental and analytic method. The insertion loss is measured by using the direct method in accordance with the ISO code, while theoretical prediction is based on Muradali and Fyfe's method (Applied Acoustics, Vol. 53, 49~75, 1998). In addition to the diffraction at the top of the barrier, the waves are reflected infinite times between the building and the barrier, which is equivalent to replacing the building by the infinite series of the image receiver points. In two-dimensional study, the prediction of the insertion loss results in significantly overestimated values compared with the measurement. However three-dimensional analysis shows reasonable agreements, where traffic noise is assumed as incoherent line source and the length of the source is larger than that of the barrier.

  • PDF

Frequency-Domain Circuit Model and Analysis of Coupled Magnetic Resonance Systems

  • Huh, Jin;Lee, Wooyoung;Choi, Suyong;Cho, Gyuhyeong;Rim, Chuntaek
    • Journal of Power Electronics
    • /
    • v.13 no.2
    • /
    • pp.275-286
    • /
    • 2013
  • An explicit frequency-domain circuit model for the conventional coupled magnetic resonance system (CMRS) is newly proposed in this paper. Detail circuit parameters such as the leakage inductances, magnetizing inductances, turn-ratios, internal coil resistances, and source/load resistances are explicitly included in the model. Accurate overall system efficiency, DC gain, and key design parameters are deduced from the model in closed form equations, which were not available in previous works. It has been found that the CMRS can be simply described by an equivalent voltage source, resistances, and ideal transformers when it is resonated to a specified frequency in the steady state. It has been identified that the voltage gain of the CMRS was saturated to a specific value although the source side or the load side coils were strongly coupled. The phase differences between adjacent coils were ${\pi}/2$, which should be considered for the EMF cancellations. The analysis results were verified by simulations and experiments. A detailed circuit-parameter-based model was verified by experiments for 500 kHz by using a new experimental kit with a class-E inverter. The experiments showed a transfer of 1.38 W and a 40 % coil to coil efficiency.

Antenna Dependency of Mode Transition in Cylindrical ICP Light-source (원통형 ICP 광원 모드변환의 안테나 의존성)

  • Yang, Jong-Kyung;Pack, Gewnag-Hyeon;Lee, Jong-Chan;Park, Dae-Hee;Yoon, Yang-Woung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.8
    • /
    • pp.772-778
    • /
    • 2005
  • In this paper, we designed the cylindrical type light source that had a electromagnetic principle of inductively coupled plasma, and measured its electrical-optical properties. Using the principle of transformer, electrically equivalent circuit of cylindrical type light source was analyzed. According to the parameters of electromagnetic induction which were diameter of coil with $0.3\~1.2\;mm{\Phi}$, number of turns with $4\~12$ turns, distance with $40\~120$ mm and RF power with $10\~150$ W, the electrical and optical properties were measured. When diameter of coil was $0.3\;mm{\Phi}$, number of turns was 8 turns and distance was 40 mm, the highest brightness of 29,730 $cd/m^2$ was shown with RF power 150 W. The relationship between electromagnetic induction and plasma discharges was shown by mode transition from E-mode to H-mode.

DSP BASED CONTROL OF HIGH POWER STATIC VAR COMPENSATOR USING NOVEL VECTOR PRODUCT PHASE LOCKED LOOP (새로운 벡터적 PLL를 이용한 대용량 무효전력 보상기(SVC)의 DSP 제어)

  • Jung, Gu-H.;Cho, Guk-C.;Chae, Cyun;Cho, Gyu-H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.262-264
    • /
    • 1996
  • This paper presents a new dual loop control using novel vector phase locked loop(VP-PLL) for a high power static var compensator(SVC) with three-level GTO voltage source inverter(VSI). Through circuit DQ-transformation, a simple dq-axis equivalent circuit is obtained. From this, DC analysis is carried out to obtain maximum controllable phase angle ${\alpha}_{max}$ per unit current between the three phase source and the switching function of inverter, and AC open-loop transfer function is given. Because ${\alpha}_{max}$ becomes small in high power SVC, this paper proposes VP-PLL for more accurate $\alpha$-control. As a result, the overall control loop has dual loop structure, which consists of inner VP-PLL for synchronizing the phase angle with source and outer Q-loop for compensating reactive power of load. Finally, the validity of the proposed control method is verified through the experimental results.

  • PDF

Highspeed Train : Sound Power and Noise Propagation Characteristics (고속철도의 소음 특성과 전파현상)

  • 김정태;은희준
    • Journal of KSNVE
    • /
    • v.6 no.3
    • /
    • pp.349-355
    • /
    • 1996
  • For a rail traffic noise, a typical source has a length of 200m - 400m so that the noise pollution areas have been located in the transition regions where the sound level drops between 3dB/dd and 6dB/dd. Therefore, in this region, parameters such as a horizontal distance from the track, the geometry of the ground surface, the environmental effect, and the boundary impedance condition play import roles, especially in our nation's situation. In this study, modelling techniques for the finite length of noise source have been investigated in order to evaluate the rail traffic noise level. Then. noise correction value .${\Delta}$SPL for various location in the track region is represented by the non-dimensionalized horizontal and parallel distance from the track. As an application, a high speed train is examined. Beas on the noise data measured for a Eurostar in France, the sound power value per unit length $H_1$is calcuated. It turns out that$H_1$is 109 dB. Overall sound power from the highspeed train to be serviced in our country is expected to 135 dBA.

  • PDF

Study of Corrosion-Induced Failure Mechanisms of Epoxy Coated Reinforcing Steel (Parts I and II)

  • Lee, Seung-kyoung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.04a
    • /
    • pp.396-401
    • /
    • 1995
  • Epoxy coated reinforcing steels (ECRs) were acquired from ten sources and coatings from each source were initially characterized in terms of defects, thickness, solvent extraction weight loss and hardness. Testing involved exposure in three aqueous solutions at elevated temperature (8$0^{\circ}C$) and in chloride-contaminated concrete slabs under outdoor exposure, It was found that the density and size of coating defects was the promary factor affecting ECR performance. The equivalent circuit analysis using electrochemical impedance spectroscopy (EIS) data indicated that the impedance response for well-performing ECR specimens showed no signs of active degradation at the interface although diffusional processes similar to those noted for poorly performing bars occurred here. Experimental results also indicated a relationship between corrosion behavior and bar source. Weight loss upon solvent extraction correlated with impedance reduction from hot water exposure. Coating defects during most of the tests, especially in high pH solutions containing chloride ions. ECRs with excessive coating defects, either initially present or ones which developed in service, performed poorly in every test category regardless of source. Forms of coating failure were extensive rusting at defects, blistering, wet adhesion loss, cathodic delamination, underfilm corrosion and coating cracks. These occurred sequentially or concurrently, depending on the condition of the ECR and nature of the environment

  • PDF

Evaluation and Comparison of the Low-Frequency Oscillation Damping Methods for the Droop-Controlled Inverters in Distributed Generation Systems

  • Tao, Yong;Deng, Yan;Li, Guangdi;Chen, Guipeng;He, Xiangning
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.731-747
    • /
    • 2016
  • The droop-based control strategy is widely applied in the interfacing inverters for distributed generation. This can be a problem since low-frequency stability issues may be encountered in droop-based microgrid. The objective of this paper is to classify, evaluate and compare various low-frequency damping methods. First, low-frequency stability problems are analyzed and an equivalent model of a droop-controlled inverter is investigated to classify the damping methods into the source-type damping strategies and the impedance-type damping strategies. Moreover, the lead-lag compensation network insertion control is proposed as a beneficial part of the source-type damping strategies. Then, the advantages and disadvantages of the different types of damping methods are theoretically evaluated and experimentally tested. Furthermore, the damping methods are comprehensively compared to illustrate the application field of each method. Finally, the synthesis of different damping methods to enhance the low-frequency stability is discussed and experimental validation is presented.

Analysis of Common Mode Voltages at Diode Rectifier/Z-Source Inverter System (다이오드 정류기/Z-소스 인버터 시스템의 공통모드 전압 해석)

  • Tran, Quang-Vinh;Chun, Tae-Won;Lee, Hong-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.285-292
    • /
    • 2009
  • In this paper, when ac motors are driven by the diode rectifier/Z-source inverter system, the common-mode voltages of system are analyzed in details under both the shoot-through state and non-shoot-through state through equivalent circuits. Then a modified space vector modulation strategy is suggested for attenuating the negative common-mode voltage by eliminating the zero voltage vector, and also controlling the shoot-through time. Through the simulation studies with PSIM and experiments with 32-bit DSP, it is verified that the negative common-mode voltage can be reduced by more than 50%.

Eco-friendly Production of Maize Using Struvite Recovered from Swine Wastewater as a Sustainable Fertilizer Source

  • Liu, YingHao;Rahman, M.M.;Kwag, Jung-Hoon;Kim, Jae-Hwan;Ra, Chang-Six
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.24 no.12
    • /
    • pp.1699-1705
    • /
    • 2011
  • Magnesium ammonium phosphate (MAP) was recovered from swine wastewater and the feasibility of reutilizing it as a slowly-releasing fertilizer was evaluated. Maize growth was investigated with normal and high application rates of MAP and a fused super phosphate (FSP) fertilizer. A total of 5 treatments ($T_0$ = control, $T_1$ = MAP based on 30 kg P $ha^{-1}$, $T_2$ = FSP based on 30 kg P $ha^{-1}$+urea equivalent to nitrogen of MAP applied in $T_1$, $T_3$ = MAP based on 40 kg P $ha^{-1}$, $T_4$ = FSP based on 40 kg P $ha^{-1}$+urea equivalent to nitrogen of MAP applied in $T_3$) were arranged with 3 replications. In the case of height and circumference, significant differences were found between controls and treated maize plants (p<0.01). However, no statistical differences were found between MAP- and FSP-urea treated maize. Leaf area and green biomass yield were significantly (p<0.01) higher in the treated group than control. Leaf area was also found significantly higher (p<0.01) in the higher MAP- treated group (2,374 $cm^2$ $plant^{-1}$) than other treatments. $N_2O$ emission was found to be lower in MAP treated soil than that from FSP-urea treated soil, which might be due to the slow releasing pattern of MAP. It could be assumed from the results that MAP would be an eco-friendly sustainable fertilizer source for crop production.