• Title/Summary/Keyword: equivalent frame

Search Result 280, Processing Time 0.029 seconds

A Parametric Study on Intermediate Diaphragms of Steel-Box-Girder Bridges (강박스 거더교의 내부 다이아프램에 관한 매개변수 연구)

  • Park, Nam Hoi;Lim, Da Soo;Cho, Sun Kyu;Kang, Young Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.3
    • /
    • pp.231-239
    • /
    • 2003
  • Many box girder bridges have been constructed during the past several decades due to their large bending and torsional rigidities as well as aesthetic considerations. However, box girders have shortcoming in that the cross section distorts under an eccentric loading and warps out of the section plane. Therefore, in order to reduce distortional stresses such as distortional warping and transverse bending normal stresses, diaphragms were generally installed in the box girders. Shapes of the diaphragms in steel-box-girder bridges constructed up to date were solid-plate, frame, and truss types. The objectives of this study using parametric study were to evaluate the appropriate stiffness ratio of intermediate diaphragms and then to propose the effective spacing and numbers of intermediate diaphragms based on the evaluated stiffness ratio. Target bridges for this study were straight continuous span bridges with a single-cell steel box section. The parameters for the parametric study were the shape of box section, the span numbers, the equivalent span length, the stiffness of intermediate diaphragms, and the spacing of intermediate diaphragms. From the results of the parametric study, the effective spacing and numbers as well as the stiffness ratio of the intermediate diaphragms will be presented.

Dynamic Modeling and Simulation of a Towing Rope using Multiple Finite Element Method (다물체 요소이론을 이용한 예인줄 동역학의 모델링 및 시뮬레이션)

  • Yoon, Hyeon-Kyu;Lee, Hong-Seok;Park, Jong-Kyu;Kim, Yeon-Gyu
    • Journal of Navigation and Port Research
    • /
    • v.36 no.5
    • /
    • pp.339-347
    • /
    • 2012
  • After towing rope connecting a barge to a tug was subdivided into multiple finite elements, then those dynamic models was established using Newton's second law and considering the external force and moment such as tension, drag, Coriolis force, gravity, buoyancy, and impact due to free surface acting on each element. While the previous research on the model of towing rope considered only translation, five-degree-of-freedom equations of motion except roll based on the body-fixed frame were established in this paper. All elements are connected by a spring and a damper, and the stiffness of the spring was set as the equivalent value of the real rope. In order to confirm the established multiple finite element model, various scenarios such as freely falling of towing rope in the air and above the free surface, accelerating of a tug which tows a barge connected by towing rope, and sinusoidal moving of a tug were set up and simulated. As the results, the trajectories of the tug, the barge, and the towing rope showed good tendencies to the ones of real expected situations.

A Comparative Study on the Current Status of Spectacle Frames Standards (안경테 표준규격 실태에 관한 비교 연구)

  • Yu, Dong-Sik;Kim, In-Su;Son, Jeong-Sik;Sung, Duk-Yong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.9-15
    • /
    • 2009
  • Purpose: The aim of this study is to examine various national standards and to suggest problems and improvements on KS (Korean Industrial Standards) in spectacle frames. Methods: We surveyed the latest published KS, ISO (International Organization for Standardization), JIS (Japanese Industrial Standards), DIN (Deutsches Institut fur Normung) and ANSI (American National Standards Institute) standards with relating spectacle frames. The titles that were considered in comparative study were terms and vocabulary, measuring system and terminology, marking, requirements and test methods, formers, screw threads, and others. Results: There were 9 different languages such as English (USA and UK), French, Russian, Japanese, Chinese, German, Italian and Spanish for the lists of equivalent terms and vocabulary in all standards except KS and ANSI, but gave an explanation for terms and vocabulary in only KS. Complementary terms and definitions were not existed in annex of KS and ANSI for measuring system and terminology, but they were included in annex of standards of the others. KS and ANSI standard for requirements and test methods differed from the ISO revision. Except JIS and ANSI, standards of formers were almost identical. KS standard of screw threads were similar to JIS. Standards of welded joints and nickel release did not exist in KS. Conclusions: All standards except ANSI tend to follow ISO, especially DIN is almost entirely identical to ISO. But KS is behind the times because it has been amended lately or established in accordance with older editions of ISO. Therefore, in order to assist quality control and safety for spectacle frames, KS standards shall be superseded by the specifications which is identical to ISO within a reasonable time.

  • PDF

The Study of New Reconstruction Method for Brain SPECT on Dual Detector System (Dual detector system에서 Brain SPECT의 new reconstruction method의 연구)

  • Lee, Hyung-Jin;Kim, Su-Mi;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.57-62
    • /
    • 2009
  • Purpose: Brain SPECT study is more sensitive to motion than other studies. Especially, when applying 1-day subtraction method for Diamox SPECT, it needs shorter study time in order to prevent reexamination. We were required to have new study condition and analysing method on dual detector system because triple head camera in Seoul National University Hospital is to be disposed. So we have tried to increase image quality and make the dual and triple head to have equivalent study time by using a new analysing program. Materials and Methods: Using IEC phantom, we estimated contrast, SNR and FWHM. In Hoffman 3D brain phantom which is similar with real brain, we were on the supposition that 5% of injected doses were distributed in brain tissue. To compare with existing FBP method, we used fan-beam collimator. And we applied 15 sec, 25 sec/frame for each SEPCT studies using LEHR and LEUHR. We used OSEM2D and Onco-flash3D reconstruction method and compared reconstruction methods between applied Gaussian post-filtering 5mm and not applied as well. Attenuation correction was applied by manual method. And we did Brain SPECT to patient injected 15 mCi of $^{99m}Tc$-HMPAO according to results of Phantom study. Lastly, technologist, MD, PhD estimated the results. Results: The study shows that reconstruction method by Flash3D is better than exiting FBP and OSEM2D when studied using IEC phantom. Flowing by estimation, when using Flash3D, both of 15 sec and 25 sec are needed postfiltering 5 mm. And 8 times are proper for subset 8 iteration in Flash3D. OSEM2D needs post-filtering. And it is proper that subset 4, iteration 8 times for 15sec and subset 8, iteration 12 times for 25sec. The study regarding to injected doses for a patient and study time, combination of input parameter-15 sec/frame, LEHR collimator, analysing program-Flash3D, subset 8, iteration 8times and Gaussian post-filtering 5mm is the most appropriate. On the other hands, it was not appropriate to apply LEUHR collimator to 1-day subtraction method of Diamox study because of lower sensitivity. Conclusions: We could prove that there was also an advantage of short study time effectiveness in Dual camera same as Triple gamma camera and get great result of alternation from existing fan-beam collimator to parallel collimator. In addition, resolution and contrast of new method was better than FBP method. And it could improve sensitivity and accuracy of image because lesser subjectivity was input than Metz filter of FBP. We expect better image quality and shorter study time of Brain SPECT on Dual detector system.

  • PDF

The Usefulness of LEUR Collimator for 1-Day Basal/Acetazolamide Brain Perfusion SPECT (1-Day Protocol을 사용하는 Brain Perfusion SPECT에서 LEUR 콜리메이터의 유용성)

  • Choi, Jin-Wook;Kim, Soo-Mee;Lee, Hyung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.94-100
    • /
    • 2011
  • Purpose: Basal/Acetazolamide-challenged brain perfusion SPECT is very useful to assess cerebral perfusion and vascular reserve. However, as there is a trade off between sensitivity and spatial resolution in the selection of collimator, the selection of optimal collimator is crucial. In this study, we examined three collimators to select optimal one for 1-day brain perfusion SPECT. Materials and Methods: Three collimators, low energy high resolution-parallel beam (LEHR-par), ultra resolution-fan beam (LEUR-fan) and super fine-fan beam (LESFR-fan), were tested for 1-day imaging using Triad XLT 9 (TRIONIX). The SPECT images of Hoffman 3D brain phantom filled with 99mTc of 170 MBq and a normal volunteer were acquired with a protocol of 50 kcts/frame and detector rotation of 3 degree. Filterd backprojection (FBP) reconstruction with Butterworth filter (cut off frequencies, 0.3 to 0.5) was performed. The quantitative and qualitative assessments for three collimators were performed. Results: The blind tests showed that LESFR-fan provided the best image quality for Hoffman brain phantom and the volunteer. However, images for all the collimator were evaluated as 'acceptable'. On the other hand, in order to meet the equivalent signal-to-noise ratio (SNR), total acquisition time or radioactivity dose for LESFR-fan must have been increased up to almost twice of that for LEUR-fan and LEHR-par. The volunteer test indicated that total acquisition time could be reduced approximately by 10 to 14 min in clinical practice using LEUR-fan and LEHR-par without significant loss on image quality, in comparison with LESFR-fan. Conclusion: Although LESFR-fan provides the best image quality, it requires significantly more acquisition time than LEUR-fan and LEHR-par to provide reasonable SNR. Since there is no significant clinical difference between three collimators, LEUR-fan and LEHR-par can be recommended as optimal collimators for 1-day brain perfusion imaging with respect to image quality and SNR.

  • PDF

A Critical Discourse Analysis Through Comparisons Between Editorials of The Global Times, Huánqiú Shíbào on the 2018 United States-China Trade War (미·중 무역 분쟁 관련 환구시보(環球時報) 사설 비교를 통한 비판적 담화분석 - 「용타항미원조적의지타대미무역전(用打抗美援朝的意志打對美貿易戰)」 중심으로 -)

  • Choi, Tae-hoon
    • Cross-Cultural Studies
    • /
    • v.52
    • /
    • pp.165-194
    • /
    • 2018
  • Employing Fairclough's critical discourse analysis (CDA), the purpose of this study was to analyze linguistically significant features, intertextuality, and sociocultural practice focusing on selected editorials of The Global Times, $Hu{\acute{a}}nqi{\acute{u}}$ Shíbào on the 2018 United States-China Trade War. The editorial titled "With the strong will of 'the War to Resist America and Aid Chosun,' let us go through the trade war against America" focused on the use of 'war' related vocabulary in the frame of 'war.' First, "Trade War" and "War to Resist America and Aid Chosun" are examples that reveal metaphors and a war frame. Second, "Strategy" is used positively for China but negatively towards America. Third, various war related words are used. Fourth, cases of allusion illustrate war. Intertextuality in terms of discourse practice pertains to two findings. First, The Global Times, $Hu{\acute{a}}nqi{\acute{u}}$ Shíbào repeatedly uses the phrase 'equivalent revenge.' That is because the expression enables China to justify their counterattack and such war that China may wage can be interpreted as just counterattack much like a self-defense mechanism. Second, the expression, 'the counterattack is not intended but it is not fearful' is repeated in several editorials of the newspaper. The reasons are the following: 1) it is used to appeal to the public, 2) by invoking the feeling of fear, the public should be understand why they should unite, and 3) the expression, "it is not fearful" is used to preserve China's global image and "the counterattack is not intended" is used to signal China's will to America. The whole expression is a good example of intertextuality that repetitively illustrates the intended meaning of China in nine editorials in the newspaper within three months, March 23-June 17, 2018. Finally, sociocultural practice is manipulated through the editorial for disseminating the Chinese government's hegemonic ideology. First, it is clear that the core national project, "China Manufacturing 2025" cannot be abandoned. Second, by calling for "War to Resist America and Aid Chosun" the editorial is manipulated to condemn and intimidate America, avoid dissent of the people, appeal to the people, and empower the government. Third, China somehow wants to open up the possibility of negotiation with the United Sates.

Evaluation of the Image Quality According to the Pre-set Method in PET/CT Image (PET/CT 영상 획득 시 사전설정법 차이에 따른 영상 질 평가)

  • Park, Sun-Myung;Lee, Hyuk;Hong, Gun-Chul;Chung, Eun-Kyung;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.41-46
    • /
    • 2011
  • Purpose: The result of exam using an imaging device is very closely related with the image quality. Moreover, this image quality can be changed according to the condition of image acquisition and evaluation method. In this study, we evaluated the image quality according to the difference of pre-set method in PET/CT image. Materials & Methods: PET/CT Discovery STe16 (GE Healthcare, Milwaukee, USA), Chest PET phantom (Experiment 1) and 94 NEMA phantom (Experiment 2) were used. Phantom were filled with $^{18}F$-FDG maintaining hot sphere and background ratio to 4:1. In the case of experiment 1, we set the radio activity concentration on 3.5, 6.0, 8.6 kBq/mL. In the case of experiment 2, we set the radio activity concentration on 3.3, 5.5, 7.7, 9.9, 12.1, 16.5 kBq/mL. All experiments were performed with the time-set method for 2 minutes 30 seconds per frame and the count-set method with one hundred million counts in 3D mode after CT transmission scan. For the evaluation of the image quality, we compared each results by using the NECR and SNR. Results: In the experiment 1, both the NECR and SNR were increased as radioactivity concentration getting increased. The NECR was shown as 53.7, 66.9, 91.4. and SNR was shown as 7.9, 10.0, 11.7. Both the NECR and SNR were increased in time-set method. But the count-set method's pattern was not similar with the time-set method. The NECR was shown as 53.8, 69.1, 97.8, and SNR was shown as 14.1, 14.7 14.4. The SNR was not increased in count-set method. In experiment 2, results of both the NECR and SNR were shown as 45.1, 70.6, 95.3, 115.6, 134.6, 162.2 and 7.1, 8.8, 10.6, 11.5, 12.7, 14.0. These results were shown similar patten with the experiment 1. Moreover, when the count-set method was applied, the NECR was shown as 42.1, 67.3, 92.1, 112.2, 130.7, 158.7, and SNR was shown as 15.2, 15.9, 15.6, 15.4, 15.5, 14.9. The NECR was increased but SNR was not shown same pattern. Conclusion: Increment of administered radioactivity improves the quality of image unconcerned with the pre-set method. However, NECR was not influenced by increment of total acquisition counts through simple increasing scan duration without increment of administered activity. In case of count-set method, the SNR was shown similar value despite of increment of radioactivity. So, the administered activity is more important than the scan duration. And we have to consider that evaluation of image quality using only SNR may not be appropriate.

  • PDF

Performance Characteristics of 3D GSO PET/CT Scanner (Philips GEMINI PET/DT) (3차원 GSO PET/CT 스캐너(Philips GEMINI PET/CT의 특성 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Byeong-Il;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.318-324
    • /
    • 2004
  • Purpose: Philips GEMINI is a newly introduced whole-body GSO PET/CT scanner. In this study, performance of the scanner including spatial resolution, sensitivity, scatter fraction, noise equivalent count ratio (NECR) was measured utilizing NEMA NU2-2001 standard protocol and compared with performance of LSO, BGO crystal scanner. Methods: GEMINI is composed of the Philips ALLEGRO PET and MX8000 D multi-slice CT scanners. The PET scanner has 28 detector segments which have an array of 29 by 22 GSO crystals ($4{\times}6{\times}20$ mm), covering axial FOV of 18 cm. PET data to measure spatial resolution, sensitivity, scatter fraction, and NECR were acquired in 3D mode according to the NEMA NU2 protocols (coincidence window: 8 ns, energy window: $409[\sim}664$ keV). For the measurement of spatial resolution, images were reconstructed with FBP using ramp filter and an iterative reconstruction algorithm, 3D RAMLA. Data for sensitivity measurement were acquired using NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves after we confirmed that dead time loss did not exceed 1%. To measure NECR and scatter fraction, 1110 MBq of F-18 solution was injected into a NEMA scatter phantom with a length of 70 cm and dynamic scan with 20-min frame duration was acquired for 7 half-lives. Oblique sinograms were collapsed into transaxial slices using single slice rebinning method, and true to background (scatter+random) ratio for each slice and frame was estimated. Scatter fraction was determined by averaging the true to background ratio of last 3 frames in which the dead time loss was below 1%. Results: Transverse and axial resolutions at 1cm radius were (1) 5.3 and 6.5 mm (FBP), (2) 5.1 and 5.9 mm (3D RAMLA). Transverse radial, transverse tangential, and axial resolution at 10 cm were (1) 5.7, 5.7, and 7.0 mm (FBP), (2) 5.4, 5.4, and 6.4 mm (3D RAMLA). Attenuation free values of sensitivity were 3,620 counts/sec/MBq at the center of transaxial FOV and 4,324 counts/sec/MBq at 10 cm offset from the center. Scatter fraction was 40.6%, and peak true count rate and NECR were 88.9 kcps @ 12.9 kBq/mL and 34.3 kcps @ 8.84 kBq/mL. These characteristics are better than that of ECAT EXACT PET scanner with BGO crystal. Conclusion: The results of this field test demonstrate high resolution, sensitivity and count rate performance of the 3D PET/CT scanner with GSO crystal. The data provided here will be useful for the comparative study with other 3D PET/CT scanners using BGO or LSO crystals.

The Evaluation of Reliability for the Combined Refractive Power of Overlapping Trial Lenses (중첩된 시험렌즈의 합성굴절력에 대한 신뢰도 평가)

  • Lee, Hyung Kyun;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.263-276
    • /
    • 2015
  • Purpose: The current study aimed to evaluate the reliability for the combined refractive power when a spherical lens and a cylindrical lens were overlapped in a trial frame. Methods: The refractive powers, central thickness and peripheral thickness of spherical trial lenses and cylindrical lenses with negative power were measured. The combined refractive power of the spherical and cylindrical lenses was measured by auto lens meter. Measurement was repeated by changing the insertion order, and their results were further compared with the calculated combined refractive power. Results: There was no correlation between the variation of central and peripheral thickness in trial lenses and that of the lens power. Among 79 trial lenses, 3 trial lenses wasn't met the international standard. The refractive power calculated by Gullstrand's formula that could compensate vertex distance had smaller difference with the estimated power when compared with that calculated by thin lens formula however, it was significantly different from the estimated power. The refractive powers were generally apparent regardless of the insertion order of a spherical lens and a cylindrical lens: thin lens formula > actual measurements > Gullstrand's formula. The error was only found in cylindrical power calculated by Gullstrand's formula when inserted a spherical lens inside and a cylindrical lens outside however, the error was found in both of cylindrical and spherical powers calculated by Gullstrand's formula when inserted as a opposite order. By comparing actual measurements of equivalent spherical power, the accuracy was higher and the possibility of over-correction was lower when inserted a spherical lens inside and a cylindrical lens outside. Conclusions: From the results, those were revealed that the combined refractive power is influenced by the factors other than the vertex distance and the refractive power varies in accordance with the insertion order of a spherical lens and a cylindrical lens. Thus, it can be suggested that the establishment of standard for these is neccesaty.

The Conceptual Intersection between the Old and the New and the Transformation of the Traditional Knowledge System (신구(新舊) 관념의 교차와 전통 지식 체계의 변용)

  • Lee, Haenghoon
    • The Journal of Korean Philosophical History
    • /
    • no.32
    • /
    • pp.215-249
    • /
    • 2011
  • This essay reflects on the modernity of Korea by examining the transformation of the traditional knowledge system from a historico-semantic perspective with its focus on the opposition and collision of the old and the new conception occurred in the early period(1890~1910) of the acceptance of the Western modern civilization. With scientific success, trick of reason, Christianity and evolutionary view of history, the Western modernity regarded itself as a peak of civilization and forced the non-Western societies into the world system in which they came to be considered as 'barbarism(野蠻)' or 'half-enlightened(半開).' The East Asian civilization, which had its own history for several centuries, became degraded as kind of delusion and old-fashioned customs from which it ought to free itself. The Western civilization presented itself as exemplary future which East Asian people should achieve, while East Asian past traditions came to be conceived as just unnecessary vestiges which it was better to wipe out. It can be said that East Asian modernization was established through the propagation and acceptance of the modern products of the Western civilization rather than through the preservation of its past experience and pursuit of the new at the same time. Accordingly, it is difficult to apply directly to East Asian societies Koselleck's hypothesis; while mapping out his Basic Concept of History, he assumed that, in the so-called 'age of saddle,' semantic struggle over concepts becomes active between the past experience and the horizon of expectation on the future, and concepts undergoes 'temporalization', 'democratization', 'ideologization', 'politicization.'The struggle over the old and new conceptions in Korea was most noticeable in the opposition of the Neo-Confucian scholars of Hwangseongsinmun and the theorists of civilization of Doknipsinmun. The opposition and struggle demanded the change of understanding in every field, but there was difference of opinion over the conception of the past traditional knowledge system. For the theorists of civilization, 'the old(舊)' was not just 'past' and 'old-fashioned' things, but rather an obstacle to the building of new civilization. On the other hand, it contained the possibility of regeneration(新) for the Neo-Confucian scholars; that is, they suggested finding a guide into tomorrow by taking lessons from the past. The traditional knowledge system lost their holy status of learning(聖學) in the process of its change into a 'new learning(新學),' and religion and religious tradition also weakened. The traditional knowledge system could change itself into modern learning by accepting scientific methodology which pursues objectivity and rationality. This transformation of the traditional knowledge system and 'the formation of the new learning from the old learning' was accompanied by the intersection between the old and new conceptions. It is necessary to pay attention to the role played by the concept of Sil(hak)(實學) or Practical Learning in the intersection of the old and new conceptions. Various modern media published before and after the 20th century show clearly the multi-layered development of the old and new conceptions, and it is noticeable that 'Sil(hak)' as conceptual frame of reference contributed to the transformation of the traditional knowledge system into the new learning. Although Silhak often designated, or was even considered equivalent to, the Western learning, Neo-Confucian scholars reinterpreted the concept of 'Silhak' which the theorists of civilization had monopolized until then, and opened the way to change the traditional knowledge system into the new learning. They re-appropriated the concept of Silhak, and enabled it to be invested with values, which were losing their own status due to the overwhelming scientific technology. With Japanese occupation of Korea by force, the attempt to transform the traditional knowledge system independently was obliged to reach its own limit, but its theory of 'making new learning from old one' can be considered to get over both the contradiction of Dondoseogi(東道西器: principle of preserving Eastern philosophy while accepting Western technology) and the de-subjectivity of the theory of civilization. While developing its own logic, the theory of Dongdoseogi was compelled to bring in the contradiction of considering the indivisible(道and 器) as divisible, though it tried to cope with the reality where the principle of morality and that of competition were opposed each other and the ideologies of 'evolution' and 'progress' prevailed. On the other hand, the theory of civilization was not free from the criticism that it brought about a crack in subjectivity due to its internalization of the West, cutting itself off from the traditional knowledge system.