• Title/Summary/Keyword: environment units

Search Result 1,005, Processing Time 0.023 seconds

Development and validation of novel simple prognostic model for predicting mortality in Korean intensive care units using national insurance claims data

  • Ah Young Leem;Soyul Han;Kyung Soo Chung;Su Hwan Lee;Moo Suk Park;Bora Lee;Young Sam Kim
    • The Korean journal of internal medicine
    • /
    • v.39 no.4
    • /
    • pp.625-639
    • /
    • 2024
  • Background/Aims: Intensive care unit (ICU) quality is largely determined by the mortality rate. Therefore, we aimed to develop and validate a novel prognostic model for predicting mortality in Korean ICUs, using national insurance claims data. Methods: Data were obtained from the health insurance claims database maintained by the Health Insurance Review and Assessment Service of South Korea. From patients who underwent the third ICU adequacy evaluation, 42,489 cases were enrolled and randomly divided into the derivation and validation cohorts. Using the models derived from the derivation cohort, we analyzed whether they accurately predicted death in the validation cohort. The models were verified using data from one general and two tertiary hospitals. Results: Two severity correction models were created from the derivation cohort data, by applying variables selected through statistical analysis, through clinical consensus, and from performing multiple logistic regression analysis. Model 1 included six categorical variables (age, sex, Charlson comorbidity index, ventilator use, hemodialysis or continuous renal replacement therapy, and vasopressor use). Model 2 additionally included presence/absence of ICU specialists and nursing grades. In external validation, the performance of models 1 and 2 for predicting in-hospital and ICU mortality was not inferior to that of pre-existing scoring systems. Conclusions: The novel and simple models could predict in-hospital and ICU mortality and were not inferior compared to the pre-existing scoring systems.

A Development of Concept Map as an Advance Organizer Based on Analysis of the Overlapped and Connected Contents between Home Economics Textbooks and those of Other Subject Matters in the Middle School - Focused on 'Resource Management and Environment' - (타 교과와의 중복성 분석에 기초한 중학교 가정교과의 선행조직자로서의 개념도 개발 - '자원의 관리와 환경'영역을 중심으로 -)

  • Cho, Su-Kyung;Chae, Jung-Hyun
    • Journal of Korean Home Economics Education Association
    • /
    • v.19 no.2
    • /
    • pp.131-152
    • /
    • 2007
  • The purpose in this study was to develope the concept maps of sub-units included in 'resource management and environment' area of Home Economics(HE) as an advance organizer after analyzing the overlapped and connected contents between HE textbooks and those of other subject matters(Ethics, Social Studies, Sciences, and Physical Education) taught in the middle schools. The results of this study were as follows. First, the unit of 'resource facilitation and environment' of HE is dealt in Ethics. Specifically the overlapped content in this unit between HE and Ethics is the content of the savings of resources, recycling, and environment conservation. The unit of 'work and time of youth' is dealt in Ethics and Science. The overlapped content of this unit is that of the concept of 'work'. While Ethics focuses on the general concept of work, Science focuses on the scientific concept of work. Home Economics doesn't focus on the concept of work but on how to manage the work. In the unit of the 'adolescents and their consumption', there are many overlapped contents among three subject matters, HE, Ethics and Social Studies. Second, the 7 concept maps were developed by following the steps: (1) confirming the learning objectives presented in the 'resource management and environment' area of HE; (2) identifying the overlapped and connected contents between HE and other subject matters(Eethics, Social Studies, Sciences, and Physical Education); (3) organizing the overlapped and connected contents between HE textbooks and those of other subject matters.

  • PDF

A Study of Microbial Contamination in Fresh-Cut and Ready-to-Eat Foods Purchased from Online Markets (온라인 판매 신선편의식품 및 즉석섭취식품의 미생물 오염도 연구)

  • Hye-Sun Hwang;Jae-Hoon Jeong;Young-Hee Kwon;Ye-Jee Byun;Ji-Young Park;Ho-Cheol Yun
    • Journal of Food Hygiene and Safety
    • /
    • v.39 no.4
    • /
    • pp.335-342
    • /
    • 2024
  • This study aimed to examine the delivery conditions and microbial contamination of fresh-cut and ready-to-eat foods purchased from online markets between February and November 2023. Upon arrival, the average surface temperature of the products was 11.3℃. In the fresh-cut foods, the average number of total aerobic bacteria and coliforms was 4.5 log colony-forming units (CFU)/g and 1.2 log CFU/g, respectively, whereas in the ready-to-eat foods, these values were 10.6 log CFU/g and 1.2 log CFU/g, respectively. Pathogens, such as Staphylococcus aureus, Salmonella spp., Clostridium perfringens, Listeria monocytogenes, and pathogenic Escherichia coli were absent from all samples. Bacillus cereus was found in 2.7% of the fresh-cut foods and 0.9% of the ready-to-eat foods, with contamination levels averaging 0.05 log CFU/g and 0.01 log CFU/g, respectively. In the four samples in which B. cereus was detected, genetic testing of the six toxin genes produced by B. cereus revealed the presence of at least one enterotoxin gene, excluding the emetic toxin. L. monocytogenes was absent from ready-to-eat foods but was detected in 0.9% of fresh-cut foods. Analysis of the isolated L. monocytogenes confirmed the presence of six pathogenicity-related genes, including iap, indicating the potential risk of foodborne diseases.

Cooling Performance of Horizontal Type Geothermal Heat Pump System for Protected Horticulture (시설원예를 위한 수평형 지열 히트펌프의 냉방성능 해석)

  • Ryou, Young-Sun;Kang, Youn-Ku;Kang, Geum-Chun;Kim, Young-Joong;Paek, Yee
    • Journal of Bio-Environment Control
    • /
    • v.17 no.2
    • /
    • pp.90-95
    • /
    • 2008
  • It has become a big matter of concerns that the skill and measures against reduction of energy and cost for heating a protected horticultural greenhouse were prepared. But in these days necessity of cooling a protected horticultural greenhouse is on the rise from partial high value added farm products. In this study, therefore, a horizontal type geothermal heat pump system with 10 RT scale to heat and cool a protected horticultural greenhouse and be considered to be cheaper than a vertical type geothermal heat pump system was installed in greenhouse with area of $240\;m^2$. And cooling performances of this system were analysed. As condenser outlet temperature of heat transfer medium fluid rose from $40^{\circ}C$ to $58^{\circ}C$, power consumption of the heat pump was an upturn from 11.5 kW to 15 kW and high pressure rose from 1,617 kPa to 2,450 kPa. Cooling COP had the trend that the higher the ground temperature at 1.75 m went, the lower the COP went. The COP was 2.7 at ground temperature at 1.75 m depth of $25.5^{\circ}C$ and 2.0 at the temperature of $33.5^{\circ}C$ and the heat extraction rate from the greenhouse were 28.8 kW, 26.5 kW respectively at the same ground temperature range. 8 hours after the heat pump was operated, the temperature of ground at 60 cm and 150 cm depth buried a geothermal heat exchanger rose $14.3^{\circ}C$, $15.3^{\circ}C$ respectively, but the temperature of ground at the same depth not buried rose $2.4^{\circ}C$, $4.3^{\circ}C$ respectively. The temperature of heat transfer medium fluid fell $7.5^{\circ}C$ after the fluid passed through geothermal heat exchanger and the fluid rejected average 46 kW to the 1.5 m depth ground. It analyzed the geothermal heat exchanger rejected average 36.8 W/m of the geothermal heat exchanger. Fan coil units in the greenhouse extracted average 28.2 kW from the greenhouse air and the temperature of heat transfer medium fluid rose $4.2^{\circ}C$after the fluid passing through fan coil units. It was analyzed the accumulation energy of thermal storage thank was 321 MJ in 3 hours and the rejection energy of the tank was 313 MJ in 4 hours.

A Study on Establishment of Safety Training Center Based on Virtual Reality and Augmented Reality Technology for Military Safety and Suicide Accident Prevention (가상현실(VR/AR) 기술 기반으로 군 안전 및 자살사고 예방을 위한 안전체험훈련장 구축 방안에 관한 연구)

  • Choi, Sung-oh;Min, Yong-sik;Kim, Sung-Il;Ghoi, Jong-geun
    • Journal of Internet Computing and Services
    • /
    • v.21 no.2
    • /
    • pp.139-148
    • /
    • 2020
  • Due to change in circumstances in the 2000s such as severe birthrate decline and shortened military service period, the armed forces of the Republic of Korea is currently turning to technologies and equipments from manpower, developing it to become high-tech, high-speed, and complex, resulting in an environment in which a single mistake could cause a mass mortality crisis.It is also evident that, considering aspects such as safety training curriculums and achievements of advanced countries and private education, hands-on training is a must in preventing suicides and accidents in the military, and establishing safety training centers is crucial for systematic and effective hands-on training.Soldiers who are joining the army as of now have experienced the Internet ever since they were born and easily use both virtual and augmented reality, and the current level of science and technology has developed to the point where most of the public safety experience centers are able to be replaced by virtual and augmented reality (VR/AR). Therefore, considering the aspects such as installation space, construction costs, maintenance costs, user characteristics, and education effects, other than for those trainings where real models and objects are more effective such as first aid training, it is with a strong recommendation that establishing military safety training facilities with VR/AR (Virtual and augmented reality) is a must in the coming future. We have derived the need for hands-on training by considering the development of virtual and augmented reality (VR/AR), analysis of operation status of the public safety experience centers, characteristics of military units, installation and maintenance costs, and proposed plan to establish safety training centers where effective training performance can be achieved at a lower cost than the public safety experience center. In addition, we suggested the scale of the required safety training center and the composition of the experience rooms considering the number of trainees and the environment of each military units. Given this analysis it will contribute to the prevention of military safety and suicide by building a safety training center in the future.

A Comparison of Species Composition and Stand Structure of the Forest Vegetation between Inhabited and Uninhabited Island in the South Sea, Korea (유인도서와 무인도서 산림식생의 종조성 및 군락 구조 비교)

  • Kim, Jun-Soo;Jeon, Chul-Hyun;Jung, Sung-Cheol;Kim, Chan-Soo;Won, Hyun-Gyu;Cho, Joon-Hee;Cho, Hyun-Je
    • Korean Journal of Environment and Ecology
    • /
    • v.30 no.4
    • /
    • pp.771-782
    • /
    • 2016
  • For basic information collection for the ecological management of forest vegetation in Korean island areas, forest vegetation between inhabited(Daemodo) and uninhabited(Gudo) island was classified in the Z-M phytosociological method and their ecological characteristics in terms of both floristic composition and structure analyzed. Forest vegetation of Daemodo and Gudo were divided into a total of 11 units and 8 units, respectively. Total cover and species diversity index(H') of forest vegetation showed significant differences between the two island, Daemodo has a high value in the tree layer, but, Gudo has a high value in the shrub layer. Composition of Life forms, Daemodo was N-$R_5-D_2$-e and Gudo MM-$R_5-D_2$-e. Family importance value(FIV), Daemdo has a high value in Theaceae(12.2) and Pinaceae(12.0) and Gudo in Lauraceae(16.5) and Fagaceae (11.6). The percentage of the total number of species in the family level, Daemodo is Asteraceae(4.5%) was the highest and Gudo is Liliaceae(7.3%). Indicator species of forest vegetation of the two islands, Daemodo is Nanophanerophytes(N) including Smilax china, Ligustrum japonicum and Eurya japonica was significant inicator species and Gudo is Megaphanerophytes(MM) including Dendropanax morbiferus, Castanopsis sieboldii and Actinodaphne lancifolia.

Confirmatory Analysis of Perception and Preference Scales for Work Characteristics among Korean Nurses (중환자실 근무환경 특성에 대한 간호사의 인지도와 선호도 도구 검증)

  • ;;Barbara Daily
    • Journal of Korean Academy of Nursing
    • /
    • v.29 no.2
    • /
    • pp.215-224
    • /
    • 1999
  • The study was conducted to centum the construct of individual perception and preference for work characteristics as personal factors influencing Korean nurses' job satisfaction. The subjects of the study were 231 nurses who are currently working in intensive care units and have been for a minimum of 6 months. The study used the Staff Perception and Preference Scale(Song et al., 1997) to measure the individual's perception and preference on the technical. practice. and management components of the ideal work environment. The Korean version of the Staff Perception and Preference Scale consists of 16 items on perception and 13 on preference with each item related on a scale from 1(not at all) to 4(a great deal). Psychometric testing revealed that the preference and perception scale is internally consistent with Chronbach's alphas of .83 for perception scale arid .80 for preference scale. The subscales of the perception and preference scale also showed acceptable reliability for the early stage of the development of the instruments with Chronbach alphas of .62-.76 and .69-.83 respectively. Criterion-related validity of the scale was tested by examining correlations with individual growth need that is conceptually close to individual preference. but not to individual perception. Individual growth need was significantly related to individual preference(r=.63, p<.05), but the correlation with the perception scale was not significant. A separate factor analysis for the each of perception and preference scales was performed with a three-factor loading solution based on a previous study. The results on the staff perception scale confirmed with varimax rotation that the items were cleanly and strongly loaded on technique. practice and management components, which together explained 50.7% of the variance. The factor analysis on the staff preference scale also yielded a three factor solution that explained 56.7% of the variance. but items on technique and management components were loaded together. This phenomena may due to the current nursing delivery system in Korea where nurses never experience either shared governance nor case management, and as a results they may not be able to consider management roles as their potential extended roles. Therefore, more efforts should be given to enhance nurses' autonomy and decision making in the technique, practice and management components of their work environment. Meanwhile, there is a need for continuously confirming and developing tools for individual perception and preferences to effectively enhance job satisfaction among Korean nurses through innovative work environments.

  • PDF

Characteristics of Heavy Metals (Ba, Cr) Distribution in Soil (토양 중 중금속(Ba, Cr)의 분포특성 평가)

  • Yoon, Jeong-Ki;Kim, Rog-Young;Kim, Ji In;Noh, Hoe-Jung;Yu, Soon-Ju;Kim, Tae Seung;Lee, Myung Gyu;Yun, Dae-Geun;Lee, Hong-gil;Kim, In Ja;Park, Gyoung-Hun
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.7
    • /
    • pp.61-69
    • /
    • 2015
  • This study was performed to provide fundamental data to establish the new soil pollution standards and the soil contamination management plans in a rational manner. The distribution characteristics of new soil contaminants such as barium (Ba) and chromium (Cr) in soils (n=140) were investigated in relation to land-use classification and geological features. Also, the sequential extraction test was conducted to evaluate fate and mobility of new soil contaminants. The soil samples taken from 140 sites were analyzed to survey distribution levels of selected new soil contaminants. The average concentration and range for hazardous metals (Ba, Cr) were Ba 128.946 (26.757~489.587) mg/kg, Cr 30.121 (2.579~132.783) mg/kg. Based on land use classification, the highest Ba concentration was found in factory soils, followed by dry field and park soils, while Cr concentration was highest in rice paddy soils, followed by dry field and factory soils. Within 10 geological units investigated the highest Ba and Cr concentrations were observed in the soils from Okcheon group and metamorphic rocks, respectively. The BCR (European Community Bureau of Reference) sequential extraction was conducted to identify chemical distributional existence of 2 elements of soils from each geological unit. Ba in soils is mainly assumed to exists as reducible form (such as BaSO4, BaCO3) and Cr in soils mainly is assumed to exist as residual form (such as Cr2O3, CrxFe1-x(OH)3(x < 1)).

Investigation of Plume Opacity Induced by the Combustion of Orimulsion (오리멀젼 연소로 인한 가시백연의 원인 규명)

  • Kim, Young-Hun;Kim, Jong-Ho;Joo, Ji-Bong;Lee, Jeong-Jin;Kim, Jin-Soo;Kwak, Byung-Kyu;Jeong, Jin-Heun;Park, Soong-Keun;Yi, Jong-Heop
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.3
    • /
    • pp.297-303
    • /
    • 2007
  • Orimulsion, a bitumen-in-water emulsified fuel, has been used throughout the world as a substitute fuel for heavy oil and coal. Orimulsion has relatively high levels of sulfur, nickel, and vanadium, compared to other fuel oils and coals, and has been the subject of much debate regarding the environmental impacts. In Korea, Y power plant has operated boilers with Orimulsion as a fuel, and they has some drawbacks during the plant operation, such as plume opacity. In this study, we investigated the cause of formation mechanism and factors for the plume opacity by investigating the operation data, and measuring the particle size distribution at EP(Electrostatic Precipitator), FGD(Fuel Gas Desulfurization) and TMS(Telecommunications Management System) units. Resulting data showed the primary particles below 1 ${\mu}m$ formed were regrown by the recombination of $SO_3$ in wet-limestone FGD process, and thus the secondary particles are induced to cause the plume opacity.

A Study on Measures to Improve Smoke Control Performance in Case of Fire in a Clean room as an LCD Manufacturing Process (LCD 제조공정 클린룸의 화재시 CFD를 이용한 제연성능 개선대책에 관한 연구)

  • Son, Bong-Sei;Jang, Chan-Hee
    • Fire Science and Engineering
    • /
    • v.26 no.5
    • /
    • pp.41-47
    • /
    • 2012
  • As a core process in the manufacture of state-of-the-art industrial technologies such as semiconductor and LCD, a clean room is the most important process which can affect the performance and quality of products drastically. Nevertheless, scientific research on comprehensive safety measures from a fire protection standpoint is not being carried out in Korea. This study aims to derive measures to improve smoke control systems by identifying performance and problems of smoke systems installed in clean rooms as an LCD manufacturing process and analyzing fire and evacuation simulations considering several scenarios. As a result of analysis of fires and smoke in a clean roomas an LCD manufacturing process, it is found to be necessary to stop air handling units through interlocking in case of a fire and exhaust smoke out of the room through the top of FAB in consideration of buoyancy of smoke. It is also found to be necessary to install quick response sprinkler heads and accessories to accelerate the response time, because the heat-accumulating performance of sprinkler heads decreases in this application. Despite its low density of dwelling due to the automation process, clean room is characterized by an array of complex production equipment and working environment requiring dustproof clothes, which makes it difficult to acquire evacuation safety performance. Thus, thorough control of danger factors in processes and periodic education and training are required. It is also necessary to establish a level of domestic technologies equivalent to the level of standards of advanced countries in fire protection.