• 제목/요약/키워드: environment friendly and economical

검색결과 124건 처리시간 0.023초

Measurement of UV radiation of LED lighting

  • Ku, Seong-Mo;Im, Jong-Min;Yi, Chin-Woo
    • 조명전기설비학회논문지
    • /
    • 제25권3호
    • /
    • pp.7-14
    • /
    • 2011
  • Many countries and researchers in the lighting field have focused on the LED light source as a solution to energy savings and environmental pollution. The LED light source consumes less power, has a long life and is highly economical. It is vibration and shock-resistant, and environment friendly as well. But LED lighting has some problems. In particular, the photobiological safety of LED light sources is emerging as an issue. Ultraviolet radiation from the LED light source emitted directly to the human body over a long period of time is harmful. In this paper, UV radiation from white LED was measured. Finally, the LED light source emits UV radiation, but it is relatively small when compared to others.

재활용 PET수지를 이용한 폴리머 콘크리트의 강도, 내화학성, 흡수율에 관한 실험적 연구 (A Study on the Strength. Chemical Resistance and Absorption of Polymer concrete with Recycling PET)

  • 조병완;서석구;태기호;박승국;류성희
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.805-810
    • /
    • 2003
  • It is the real circumstance in the country that not only the data and special books but also people who have an expert knowledge are short of the field of the study about plastic wastes, so that to build the Database carrying out gathering info of that is the present question obviously. The business on recycling plastic, for some reason or other, is one of the best ways as called bright prospect industry to prevent environmental pollution and obtain economical outcome by using limited resources. Plastic wastes with construction industry especially using Polymer may have a good effect on the environment and human beings and have a fine view to produce functional and Eco-friendly concrete as well. In this study, Chemical resistance and Water Absorption test in Polymer concrete using bentonite as a shrinkage control agent was made an experiment by comparing with influence on concrete strength and used to offer some valuable data about Polymer concrete.

  • PDF

Maskless용 스크린 제판 기술 연구(I) (A Study on the Maskless Plate Making Technology for Screen Printing(I))

  • 이미영;박경진;남수용
    • 한국인쇄학회지
    • /
    • 제26권1호
    • /
    • pp.73-85
    • /
    • 2008
  • We have manufactured a photoresist which has excellent dispersity and good applying property due to 330cps of viscosity for environment-friendly and economical maskless screen plate making. And the photoresist applied on the screen stretched was exposed without mask by beam projector with CRT light source. Then it was developed by air spray with $1.7kgf/cm^2$ of injection pressure. The pencil hardness and solvent resistance of curing photoresist film were worse than those of conventional photoresist film and the maximum resolution of line image formed by maskless screen plate making was 0.5 mm since the exposure system for maskless plate making has weak light intensity and the diffusion of light. But we could obtain maskless screen plate which has sharp edges of line image and confirm a possibility of dry development process by air spray method.

  • PDF

고온 초전도 SMES용 전도냉각시스템 특성시험 (Test of the Conduction Cooling System for HTS SMES)

  • 염한길
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권1호
    • /
    • pp.62-66
    • /
    • 2008
  • The characteristic of the superconducting magnetic energy storage(SMES) system is faster response, longer life time, more economical, and environment friendly than other uninterruptible power supply(UPS) using battery. So, the SMES system can be used to develop methods for improving power quality where a short interruption of power could lead to a long and costly shutdown. Recently, cryogen free SMES has developed using BSCCO(Bismuth Strontium Calcium Copper Oxide) wire. We fabricated and tested the conduction cooling system for the 600 kJ class HTS SMES. The experiment was accomplished for the simulation coils. The simulation coils were made of aluminium, it is equivalent to thermal mass of 600 kJ HTS SMES coil. The coil is cooled with two GM coolers through the copper conduction bar. In this paper, we report that the test results of cool-down and heat loads characteristics of the simulation coils. The developed conduction cooling system adapted to 600 kJ HTS SMES system and cope with the unexpected sudden heat impact, too.

축산농가에서 목초액을 이용한 암모니아 가스의 제거 특성에 관한 연구 (Ammonia Removal Characteristics by Pyroligneous Liquid at Livestock Farmhouse)

  • 박정호;전기일;정창훈
    • 한국환경과학회지
    • /
    • 제12권12호
    • /
    • pp.1309-1313
    • /
    • 2003
  • This study was carried out to obtain the optimal ammonia removal efficiency using pyroligenous liquid for the economical and environment-friendly odor removal at a petty livestock farmhouse. The ammonia removal efficiencies were evaluated due to changing dilution rates(${\times}$10, ${\times}$20, ${\times}$30, ${\times}$50 and ${\times}$100 times) and different spray amounts(10$m\ell$ and 20$m\ell$) of pyroligenous liquid. The wet scrubber device was used to remove odor in closed-type livestock farmhouse. According to dilution rate of the pyroligenous liquid, the optimum rate was 20 times and the removal efficiency increased by decreasing dilution rates. In the case of spray amounts with the optimum dilution, the amount was 20 me and the removal efficiency increased by increasing spray amount. Also, the removal efficiency by using wet deodorizing device was 83.0-97.0% with 20 times diluted liquid.

콘크리트 구조물 기반 녹화 공사에 있어서 콘크리트의 내구안전성 확보를 위한 방수 및 방근 기술의 제고 (Reconsideration of Waterproofing and Rootproofing to keep Durable Safety of Concrete Structure in the Greening System)

  • 오상근;김현수;김영근;권시원
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.927-930
    • /
    • 2008
  • Recently, the scale and form of the construction promoting in government and private organization have large scaled town. The underground area of whole town are used for every facilities, and most of concrete area are used for greening part for friendly environment construction. This greening part for concrete area have good point such as being amendment and various economical effect and improvement for environmental problem, moreover, the amount of greening part become great increased. For this factor, we have to newly consider to keep durable safety for concrete structure, therefore, we suggest that how to keep structural safety of greening area on the concrete.

  • PDF

바이모달트램 운행을 위한 운영기반시스템 개발에 관한 연구 (A Study on the Development of Operation Base System for Bimodal Tram)

  • 윤희택;박영곤;변윤섭;이강원;홍용기
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1937-1942
    • /
    • 2007
  • Bimodal tram is being developed to be completed in 2010 and the infrastructure needs to be developed to make the operation in time. Through the study of infrastructure reflecting domestic condition, dedicated lane, station, connection center, automated operation, precise docking, ticketing system, information system, management system for operation and maintenance, and refueling station will be developed and their performances will be also verified through the construction of test bed. The economical, safe and environment-friendly operation of the bimodal tram will be established through the present study.

  • PDF

Methylene Chloride의 대체세정제 적용 사례 연구 (Field Application of an Alternative Cleaning Agent to Methylene Chloride)

  • 배재흠;신민철;이통영;조기수
    • 한국표면공학회지
    • /
    • 제32권2호
    • /
    • pp.109-124
    • /
    • 1999
  • A study for replacing methylene chloride for an alternative cleaning agent which can be utilized for cleaning aluminium parts of hard disk drives was carried out at Suwon factory of Samsung Electro-mechanics Co. Ltd. As a result, quite a good cleaning agent was selected through data collection of alternative cleaning agents, their analysis of environment effects and safty factors and testing of their cleaning power. As compared with methylene chloride, the selected cleaning agent has better cleaning power. It is also more environmental-friendly, less toxic and more economical. And the operating cost reduction due to adoption of this alternative cleaning agent in Samsung Electro-mechanics Co. Ltd. was more than ₩l46,000,000 annually without any capital instrument in addition to improvement of environmental and safty conditions in the plant.

  • PDF

Analysis for Energy Efficiency of the Algae Façade - Focused on Closed Bioreactor System -

  • Kim, Tae-Ryong;Han, Seung-Hoon
    • KIEAE Journal
    • /
    • 제14권6호
    • /
    • pp.15-21
    • /
    • 2014
  • Recently, energy generation using algae technology is being promising due to the emerging issues on energy insufficiency and environmental contamination, although the solution has not been resolved in aspect of technological and economical efficiencies since it was originally proposed in the early 1980s by many scholars. The energy production technology using algae materials has great values as not only a solution for new energy generation but also an eco-friendly sustainable building equipment system. In addition, cultivation tank for algae using water sources seems to play a role as a decreasing system for thermal transmittance on building components. This study aims at investigating the adaptability towards the future sustainable building with algae technology and testifying the energy efficiency of the algae skins by operating a couple of simulation tools to measure building performances for the proposed prototype of the façade system.

마이크로그리드의 안정적 운영을 위한 풍력 및 태양광 발전원 최적 구성 비율 산정 방안 연구 (Assessment of Optimal Constitution Rate of Windturbine and Photovoltaic Sources for Stable Operation of Microgird)

  • 이수미;전영환
    • 전기학회논문지
    • /
    • 제59권2호
    • /
    • pp.272-276
    • /
    • 2010
  • Renewable energy sources are considered to be environment-friendly alternatives those are increasingly introduced in the power systems. Microgrid is one of the systems in which renewable sources have a main role as a energy suppliers. Decision of constitution rates of renewable energy sources is very important for the economical and stable operation of microgird systems. In this paper, we present a method to assess an optimal constitution rate of renewable sources especially of windturbine and photovoltaic systems.