This study intends to investigate patients' exact exposure doses by comparatively measuring ESD (Entrance Surface Dose) with the DAP meter, which excludes scattered rays, and ESD with the Xi multifunction meter, which includes scattered rays, by posture changes for Esophagography test and UGI test. The materialwere examined through Sonialvision-SafireII SPEC overtube system. ESD was measured by using the DAP meter, and as a tool to measure ESD including scattered rays on the plane of incidence of human phantom, the Xi multifunction meter was used. The average fluoroscopic time of Esophagography test was 4.192 minutes and the average number of images was 47.7, while the average fluoroscopic time of UGI test was 6.881 minutes and the average number of images was 37.8. The ratios of the incident dose of DAP meter and the ESD of Xi meter were calculated bydividing the fluoroscopic time and the number of images by each posture change. As for Esophagography test, the dose increased by 21.6~55.5% in the fluoroscopic test and by 4.8~24.7% in the spot test. In the front spot test, however, the does increased by as little as 5.3%. As for UGI test, the dose increased by 21.1~49.5% in the fluoroscopic test and by 10.1~34.9% in the spot test. It is expected that measuring doses in consideration of scattered rays by posture changes will be an important index in evaluating and managing patients' exact exposure doses for each test above. Furthermore, it is judged that this sort of study is inevitable and desirable to reduce patients' exposure doses after all.
The purpose of this study was to minimize of entrance surface dose (ESD) at the eye using high kVp technique in the computed radiography. We used REX-650R (Listem, Korea) general X-ray unit, and external detector with ESD dosimeter of Piranha 657 (RTI Electronics, Sweden). We used head of the whole body phantom. The total 64 images of X-ray anterior-posterior of skull were acquired using the film/screen (F/S) method and the digital of computed radiography method. The three radiology professor of more 10 years of clinical career evaluated a X-rays images in the same space by 5-point scale. The external detector was performed measurement of ESD of three times by same condition on the eye of the head phantom. The good image quality in the F/S method (90 kVp, 2.5 mAs) showed at the minimized ESD of 0.310 ${\pm}$ 0.001 mGy. the good image quality in the computed radiography method (90 kVp, 2.0 mAs) showed at the minimized ESD of 0.180 ${\pm}$ 0.002 mGy (P = 0.002). Finally the radiation dose could reduced about 50% in the computed radiography method more than the F/S method. In addition the eye entrance surface dose using high kVp technique with the computed radiography was reduced 92% more than conventional technique (F/S method).
본 연구는 자동노출제어장치(Automatic Exposure Control, AEC)와 수동노출 이용 시 입사표면선량(Entrance Surface Dose, ESD)과 Entropy를 분석하여 자동노출제어장치의 유용성에 대해 알아보고자 하였다. 실험방법은 Skull, Chest, Abdomen, Pelvis 부위에 대하여 란도팬텀(Rando Phantom)에 반도체 선량계를 위치시켜 선량을 측정하였고, 동시에 획득한 DICOM(Digital Imaging and Communications in Medicine) 파일을 Matlab으로 Entropy 분석을 하였다. 그 결과 자동노출제어장치 이용 시 모든 부위의 입사표면선량이 수동노출보다 낮았고 Entropy 수치는 높았으며, paired t-test는 p<0.05로 유의한 차이가 있음을 알 수 있었다. 결론적으로 자동노출제어장치의 사용은 X선 검사 시 발생할 수 있는 불필요한 방사선량과 정보의 손실량을 줄여서 피폭선량과 영상 화질의 최적화에 기여할 수 있는 유용한 방법이 될 수 있다.
본 연구는 자동노출제어장치 사용 시 이온 챔버의 성능과 조합에서 비롯된 문제를 정량적으로 분석하는 방법론을 제시하고 디지털 방사선 시스템의 성능을 최적화하고자 하였다. 실험방법은 복부와 골반부 검사에 사용된 파라미터의 X선질을 백분율 평균오차(PAE; Percentage Average Error)와 반가층(HVL; Half Value Layer)으로 평가하였다. 그 후 세 가지 이온 챔버를 조합했을 때의 입사표면선량(ESD; Entrance Surface Dose)과 엔트로피(Entropy)를 산출하여 방사선 출력의 안정성과 영상 품질을 분석하였다. 그 결과 실험에 사용한 디지털 방사선 시스템의 X선질은 모두 정상 범위의 백분율 평균오차와 반가층을 보였다. 입사표면선량은 챔버의 조합에 비례하여 증가하였고, 엔트로피는 세 개의 챔버가 조합됐을 때를 제외하고는 이온 챔버의 조합에 비례하여 증가하였다. 결론적으로 입사표면선량과 엔트로피를 이용한 분석은 이온 챔버의 성능과 조합의 문제를 평가하는데 유용한 방법인 것을 알 수 있었으며, 두 개 이하의 이온 챔버를 조합했을 때 디지털 방사선 시스템의 성능을 최적으로 유지할 수 있음을 알 수 있었다.
환자 피폭선량 관리에 입사표면선량(ESD, entrance surface dose)이 국내외적으로 진단참고준위(국내 흉부촬영 $340{\mu}Gy$)로 사용되고 있지만, ESD측정을 위해서는 선량계가 필요하다. 하지만 대부분 병의원에서는 선량계가 구비되어 있지 않고 정기검사 시 전문 업체 측정에 의해 확인할 수 있다. 따라서 본 연구에서는 흉부 디지털촬영에서 사용자가 쉽게 ESD를 예측할 수 있는 방법에 대해 알아보았다. 흉부 디지털촬영에서 평판형 디텍터(FP, Flat-panel detector)와 IP (Imaging plate detector)를 대상으로 하였고, ESD는 선량계(XI-Platinum, Unfors, Sweden)를 흉부 팬텀(07-646 Duke QC chest phantom, Supertech, Elkhart, USA)의 중앙 표면에 부착시킨 후, 튜브와 디텍터를 180cm 거리를 유지시켜 각 노출조건 조합(관전압과 노출선량)에서 3회 반복측정한 후 평균값을 얻었다. 흉부 팬텀 영상의 다이콤 헤더 정보에서 FP영상은 선량면적곱(DAP, dose-area product)을 확인하였고, IP영상에서는 노출 지수(EI, exposure index)를 확인하였다. 단순선형회귀분석을 통해 FP촬영에서 DAP로부터, IP촬영에서 EI로부터 ESD를 예측할 수 있는 회귀방정식($y={\alpha}+{\beta}X$, ${\alpha}$=직선의 절편, ${\beta}$=직선의 기울기)을 구하였다. FP가 IP 보다 유의하게 낮은 선량을 보였고($85.7{\mu}Gy$ vs. $124.6{\mu}Gy$, p=0.017), 두 디텍터 모두 ESD와 화질 간에 높은 양의 상관성을 보였다. FP에서 수정된 R 제곱(adjusted R2)은 0.978로 ESD의 변동은 DAP 변동에 의해 97.8%의 높은 설명력을 보였다. 단순 회귀식은 $ESD=0.407+68.810{\times}DAP$ 이었다. 위의 회귀식을 이용하여 국내 권고선량($340{\mu}Gy$)과 같은 DAP를 추정한 결과($DAP=0.021+0.014{\times}340{\mu}Gy$), DAP는 4.781 이었다. IP에서 수정된 R 제곱(adjusted R2)은 0.645로 ESD의 변동은 EI 변동에 의해 64.5%의 설명력을 보였다. 단순 회귀식은 $ESD=-63.339+0.188{\times}EI$ 이었다. 위의 회귀식을 이용하여 국내 권고선량($340{\mu}Gy$)과 같은 EI를 추정한 결과($EI=565.431+3.481{\times}340{\mu}Gy$), EI는 1748.97 이었다. 흉부 디지털 촬영에서는 팍스 워크스테이션 영상의 다이콤 헤더 정보에서 ESD를 사용자가 쉽게 예측할 수 있다.
소아는 성인보다 장기의 방사선에 대한 감수성이 크고 성장 중이기 때문에 더 민감하다. 피폭으로 인한 부작용을 겪는 기대수명이 길기 때문에 피폭선량의 관리가 어른의 경우보다 중요하게 다뤄진다. 본 연구는 10세 팬텀을 사용하여 현재 우리나라에 권고되어 있는 5세 소아의 촬영기준과 입사표면선량의 적합성을 확인하고 추가적으로 제시된 촬영기준으로 장기흡수선량을 측정해보았다. 임상에서 사용 중인 5세와 10세의 촬영조건과 장기흡수선량, 입사표면선량을 비교하였다. 임상 5세 촬영조건이 권고촬영조건보다 약간 높으며 임상 10세 촬영조건은 많이 높게 나타났다. 또한 권고 촬영조건으로 ESD를 측정한 결과 임상 촬영조건의 ESD가 43% 높게 나타났으며 10세의 ESD는 5세의 권고 촬영조건의 ESD 보다 126% 증가를 나타냈다. 5세의 권고된 ESD와 임상 촬영조건에 의한 ESD를 비교한 결과 31.6%의 차이를 나타냈다. 5세의 권고 촬영조건과 임상 촬영조건에 의한 장기흡수선량은 큰 차이는 없으나 흉부와 골반검사에서는 차이가 컸다. 그러나 10세의 임상 촬영조건에 의한 장기흡수선량을 비교하면 월등한 차이가 있었음을 알 수 있었다. 따라서 소아의 권고 선량에 대한 더욱 세분화된 기준안이 연구되어야 할 것으로 사료된다.
한국에서의 파노라마장치의 사용비율은 치과대학병원에서 17.8%, 치과병원에서 24.8%, 치과의원에서 31.4%로 구내촬영장치 다음으로 많이 사용하고 있는 검사 방법으로, 치아교정 및 인플란트 등의 수요증가에 따라 파노라마 검사는 지속적으로 늘어나고 있는 추세이다. 본 연구에서는 파노라마 검사에 불필요한 안구와 갑상선부위의 선량을 감소시키기 위해 납안경 및 납차폐체를 이용해 보았으며, 납안경으로 차폐를 한 경우 안구의 ESD가 41.4% 감소되었으며, X선관 부위 쪽을 차폐납으로 차폐할 경우에는 ESD의 47.3%를 감소시킬 수 있음을 알게 되었다. eyeball의 불필요한 선량저감을 위하여 임상에서는 lead glass를 사용하는 방법이 있으며, 제조사에서는 eyeball부위 피폭을 줄일 수 있는 제어장치를 적극 활용할 필요성이 있는 것으로 나타났다.
Purpose : Fluoroscopy equipment, depending on the type of changes that occur in the patient's position ESD and study the patient's scatter ray of ESD Practitioners considered a comparative analysis was to evaluate the correct dose. Materials and Methods : HITACHI four overtube type TU-8000 Flat Detector and Under tube C-Arm Philips' Multi Diagnost Eleva with Flat Detector type were measured by. Each devices is a measure of the patient's esd randophantom position in tabel unfors Xi multi funtion then fixed to the abdomen fluoroscopy and 10 seconds, spot was measured three times, practitioners of the incident surface dose by considering the patient's scatter ray of the table for each device in the average human stomach 21cm thickness acrylic phantom ($25cm{\times}25cm$) Place the practitioner position after position randophantom unfors Xi multi funtion in the thyroid and stomach 1 minute by a fixed one-time fluoroscopy and measured. Results : 10 seconds and the patient perspective of the c-arm ESD 1.2 times smaller on the AP and oblique measurements were measured in the 6-13 times smaller. spot positions to changes in the measured three times on the AP of the abdomen, ESD is 18 times smaller c-arm measurements and the oblique measurement was 19-30 times smaller. And 1 minute at practitioners fluoroscopy esd in the thyroid 2.12 times the c-arm, chest 1.75 times less the dose was measured. On the AP, depending on the device, but the lack of dose difference oblique positions of the two devices depending on changes in the area due to changes in both the AP than on the dose increased, the difference in dose between the two devices, the maximum difference was approximately 27 times. Conclusion : Fluoroscopic equipment at the time of inspection in accordance with changes in dose according to the patient and the patient's positions changes, because the area of the scatter ray considering the change of dose measurements be made, and study of the equipment according to the characteristics of the efficiency and the exposure of the patient and practitioner is considered smooth study equipment manufacturers that can be done is to build the system and think that is also important. Various fluoroscopy when you check future changes in many factors of change in dose for the equipment in the laboratory system by considering the scatter ray radiation shielding for the management to take advantage of reckless undertube have been utilized as more exposure Reduction activities can help is considered as the direction.
진단영상의학에서 일반영상촬영의 경우 각각의 부위를 연속(series)촬영으로 검사하는 경우가 대부분이다. 그러나 환자선량권고량(DRL)의 경우 각 부위의 전후(AP)방향과 측면(lateral)자세의 촬영 측정값만이 설정되어있는 것이 현실이다. 병원에서는 환자의 연속 촬영에 의해 누적 선량이 발생되며, 이는 환자선량권고량(DRL)과 누적된 피폭선량을 비교할 수 없거나, 과소평가할 수 있다. 본 연구에서 각 부위별 연속촬영의 누적선량을 측정한 결과, 조사야에 포함된 경우 입사표면선량(ESD)을 유효선량으로 변환하면 공중의 선량한도(Individual dose)의 최대 38.06%에서 최소 0.23%까지 측정되었다. 그리고 조사야에 포함되지 않은 각 부위의 입사표면선량(ESD)을 유효선량(Effective dose)으로 변환한 경우 공중의 선량한도(Individual dose)의 최대 5%에서 최소 0.04%까지 측정되었다. 연구결과 각 부위별 연속촬영에서 입사표면선량(ESD)이 많이 증가하는 것을 알 수 있다. 따라서 병원에서는 환자선량권고량(DRL)을 구체적으로 설정할 필요가 있으며, 불필요한 검사를 줄이기 위해 환자 촬영 order의 세분화가 필요하다고 판단된다. 또한, 여러 부위의 검사에서는 정확한 조사야의 필요성이 강조된다.
본 연구는 일반 X선 검사에서 CR 시스템을 이용한 환자의 근사적 피폭 선량을 평가할 수 있는 실험적 모델을 제시하고 저선량 영역에서 의료 피폭에 대한 방어의 최적화 조건으로 환자의 선량 권고량(diagnostic reference level. DRL)을 비교하고자 하였다. 이를 위하여 기준선량계와 광자극발광선량계(optically stimulated luminescence dosimeters. OSLDs)를 이용하여 관전압(kVp) 및 관전류 노출시간의 곱(mAs)에 따른 입사표면선량(entrance surface dose. ESD)을 교차 측정하였으며 CR 시스템에서 각 노출 조건에 대한 Hounsfield unit (HU) scale을 측정하여 ESD와 HU 스케일에 대한 특성 관계를 이용하여 근사적 피폭 선량을 구하였다. 또한 임상적으로 적용 가능한지를 알기 위하여 두부, 경부, 흉부, 복부, 골반부 노출 조건으로 물 팬텀에 모사하여 피폭 선량을 구하였다. 결과적으로 두 선량계의 평균 ESD는 각각 2.10, 2.01, 1.13, 2.97, 1.95 mGy 이었으며 CR 영상에서 측정한 HU 스케일은 각각 $3,276{\pm}3.72$, $3,217{\pm}2.93$, $2,768{\pm}3.13$, $3,782{\pm}5.19$, $2,318{\pm}4.64$ 이었다. 이 때 ESD와 HU 스케일에 대한 특성 관계를 이용하여 근사적으로 구한 ESD는 각각 2.16, 2.06, 1.19, 3.05, 2.07 mGy이었으며 평균 측정값과 근사적으로 구한 ESD의 오차는 3% 미만으로 영상의학 분야의 측정 오차 5%를 감안한다면 신뢰할 수 있는 오차 범위라 할 수 있었다. 결론적으로 CR 시스템을 이용한 일반 X선 검사에서 환자의 피폭 선량을 근사적으로 평가할 수 있는 새로운 실험적 모델을 제시하였으며 CR 검사뿐 만 아니라 디지털 방사선촬영(digital radiography. DR) 시스템 및 필름-증감지 시스템에 적용 가능할 것으로 판단되었다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.