에너지절약을 고려한 공동주택의 발코니 계획에 관한 연구 (A Study on the Design of Balcony in the Apartment House Focusing on the Energy Saving)

  • 박해경;김성화;홍성애;권소현;최무혁
    • 한국주거학회논문집
    • /
    • 제10권1호
    • /
    • pp.63-73
    • /
    • 1999
  • The purpose of this study is to provide new design techniques for designers to design energy saving balcony in the apartment house using solar energy passively. These design techniques are examined with some samples of foreign buildings used solar energy passively. To classify these design techniques, this study sorts out the energy saving design elements from the preliminary studies. The results of this study show how to apply each design technique to the design of balcony in the apartment house and present a classification table of these techniques. Finally, this study suggests a design solution which can be applied in the design of balcony in existing apartment house.

  • PDF

창호 구성 요소에 따른 난방에너지 절감율 예측에 관한 연구-공동주택을 중심으로 (Prediction of Heating Energy Saving Rate on the Window Type-Focus on the Apartment House)

  • 김경아;문현준;유기형
    • 한국태양에너지학회 논문집
    • /
    • 제33권6호
    • /
    • pp.54-61
    • /
    • 2013
  • This is study on the glazing performance of the apartment house to predict energy saving rate when the early design stage by calculating heating load. there are various factors of the window type in apartment building to save energy such as window's U-value, SC or SHGC, window wall ration, frame factor, sunshade coefficient and so on. In this study, we analyzed the heating load focused on the U-value, SC and window wall ration using variable heating degree days method for a small and middle size units $59m^2$, $84m^2$, respectively. Each cases were calculated heating load of the real models compared to standard model to predict energy saving rate. From those cases it was drew the conclusion that were window's U-value, SC and window wall ration for the small and middle size units to expect 10% energy saving rate at least.

에너지절약 주택과 일반 아파트에서의 실내 화학오염물질 농도 변화 특성 (The Characteristic of the Concentration Transition of Chemical Substances in Energy Saving House and Apartment House)

  • 유복희;박선효
    • 한국주거학회논문집
    • /
    • 제19권1호
    • /
    • pp.49-55
    • /
    • 2008
  • Recently, much attention has been paid to the problem such as sick building syndrome, which caused by the indoor air pollutant. Volatile Organic Compounds $(VOC_s)$ and formaldehyde have been considered as one of the main reason that causes indoor air pollutant. This study is for introducing and designing thermal performance of super energy saving building by conducting $VOC_s$ and formaldehyde concentration in the 3Liter house. The results of the measurement for 10 months showed that $VOC_s$ and formaldehyde decreased until the guideline concentration. It took about 7 months, and it appeared right after new construction. However, their levels were showed higher concentration in comparison with the ordinary residential houses (apartment house). The main difference of between newly built 3Liter house and ordinary apartment is their air changes, which are 0.67/h for 3Liter house and 4.0/h for the apartment.

저에너지 공동주택 구현을 위한 요소기술 선정 기법에 관한 연구 (Energy Saving Design Method with the Consideration of the Initial Cost for Apartment Houses)

  • 손원득;이종일;윤대원;이건호;송두삼
    • 한국태양에너지학회 논문집
    • /
    • 제34권2호
    • /
    • pp.24-31
    • /
    • 2014
  • So many energy saving strategies to realize the low energy house are proposed in these days. Even if the energy saving performances are similar between the strategies, the costs are in abroad ranges. Therefore, the application of the energy saving strategies should be based upon two considerations; one is energy saving performance and the other is the cost. In this study, the decision making method for application of the passive design technologies in the design stage of the low energy apartment house are suggested. By utilizing the result of this study, practitioners can make an effective design alternatives which solve the conflicted values; energy saving and cost.

공동주택의 난방용 도시가스 표준사용량 산정에 관한 연구 (A study on the Estimation of Standard Heating City Gas Consumption of Apartment Housing)

  • 심윤희;최창호;이현우
    • 한국태양에너지학회 논문집
    • /
    • 제26권3호
    • /
    • pp.89-97
    • /
    • 2006
  • Our Housing culture continuously changes for the correspondence to social development and changes of economy, and be developing. A massive apartment complex continuously increased, and According to this in our country heating energy consumption of a residential building is continuously increasing at country me whom was limited in order to raise efficient residential land use and diffusion ratio of house. If confirm an element to be able to reduce use of a heating energy, and there is saving possibility to parts of energy saving, this study will present the standard amount used with bases to the gas amount used for heating and Field Test data about room temperature. Execute simulation with building balance (public area, a plain), the gas amount useds such as incense of a building, indoor setting temperature ($^{\circ}C$), a position of an apartment house etc. to affect the energy amount used of a valuation object building of a variable through Field Test and research on the actual condition. Calculate the standard amount used of city gas for winter season heating of a comparative analysis apartment house to data value getting the above results through Field Test and simulations with bases.

공동주택의 실별 제어환기 도입 타당성 분석 (Feasibility Study on Installation of Individual Room Control Ventilation in Apartment House)

  • 김정엽;신현준;권용일;윤영우;조춘식
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.502-507
    • /
    • 2009
  • Trend of mechanical ventilation system applied to apartment house is introduced and feasibility study on installation of the individual room control ventilation as energy-saving method is carried out through field experiment. While initial cost of installation for the individual room control ventilation increases, the running cost is lower than the individual household control ventilation due to automatic flow rate control and reduction of fan power, and the management cost also decreases due to extension of use life of components. As the results of field experiment on $115m^2$-type apartment house, the individual room control ventilation could save the amount of 1,459.5Wh/day when compared with the individual room control ventilation

  • PDF

다원기술 상호보완식 태양열 난방기술 - 저원가 고효율 규모화 태양열 난방 방안 - (A Study on Solar Heating System Technology Combining Multiple Technology with Mutual-Complementary Method - Low-cost, high efficiency, large-scale use of solar heating system -)

  • 남보현
    • 한국태양에너지학회 논문집
    • /
    • 제28권6호
    • /
    • pp.15-23
    • /
    • 2008
  • The article deals with system technology of a new solar heating system which systematically combines exiting solar collector technology, auxiliary electrical water heating, floor heating system and well insulated construction method and its application of this system to apartment house heating system in the cold region, and also analyzed performance of the new system in terms of technical and economic feasibility. Results shows that energy efficiency approaches up to 50% of the energy consumption of local construction from 1980 to 1981. The implementation of "DQ technology" to floor heating system achieved from 79% to 85% of the energy-saving benefits comparing to other housing units which were supplied by the local district heating plant.

공동주택에서의 지역에 따른 건물에너지 효율등급 평가 연구 (A Study on the Evaluation of Building Energy Rating considering the Region of Apartment Houses)

  • 안병립;김치훈;김지연;장철용
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.15-20
    • /
    • 2009
  • Entering in the time of high oil price, seriousness of an energy effect sector has given a huge impact and the importance of energy is growing. Especially, building energy occupying 24% of total demand of energy can be expected to reduce energy demand more than other section. To do this, the Building Energy Rating System is applied and implemented in Apartment houses on Jeju, South and Central region. This system calculates into energy saving rate, and certifies the building energy rating. This study evaluates the energy saving rate and rating and compares the difference in energy savings considering to each region and the thermal performance of the window. In result, the standard of the assessment house which is applied to the build energy rating system is demanded to distinguish the thermal performance of window according to regional variation.

  • PDF

공동주택 열병합발전시스템도입에 의한 에너지 절감효과에 관한 연구 (A Research on Energy Reduction Effect of Cogeneration System of Apartment Houses)

  • 전민경;김주영;홍원화
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2006년도 추계학술발표대회 논문집
    • /
    • pp.484-487
    • /
    • 2006
  • Today, the age of high oil prices is continued, due to the energy demand is on the increase and human principlal energy sorce, fossil fuel. As an alternative plan of energy saving, co-generation system that produces power and thermal energy at the same time has actively developed. In 1960s, co-generation system was introduced to Korea and since 2000 it has diffused throughout the apartment house. Therefore, objectives of this study are to analyze the energy reduction effects in the region 4 apartment houses of Daegu and Kyungbuk regionand set up a plan for its expansion in the future.

  • PDF

지역 및 주동형태별 공동주택 외피 단열 성능에 따른 건물에너지효율등급 평가 및 분석 (Evaluation and Analysis of Building Energy Rating System Accroding to Insulation Performance of Building Envelope in Regional and Building Form of Apartment House)

  • 김민규;박효순;송규동
    • 설비공학논문집
    • /
    • 제25권2호
    • /
    • pp.49-54
    • /
    • 2013
  • In field of apartment housing currently, insulation technology is the most effective way because it is common to improve the thermal performance, therefore, it is contributed to energy saving as several regional insulation standards and legal mandate method. In addition, by applying of building energy efficiency rating certification system, it has inspired voluntary energy conservation commitment for the building owner or facility manager by making a plan to evaluate and verify building energy performance. However, these circumstances are not enough to acquire a grade 2 of higher information. Therefore, in this study, we analyzed the impact of building energy efficiency rating and confirmed reduction ratio compared to the standard housing on the basis of recent our nation building law when we had changed the shape of windows and wall insulation performance and shapes of housing.