Browse > Article

The Characteristic of the Concentration Transition of Chemical Substances in Energy Saving House and Apartment House  

Yoo, Bok-Hee (대림산업㈜ 기술연구소)
Park, Sun-Hyo (대림산업㈜ 기술연구소)
Publication Information
Journal of the Korean housing association / v.19, no.1, 2008 , pp. 49-55 More about this Journal
Abstract
Recently, much attention has been paid to the problem such as sick building syndrome, which caused by the indoor air pollutant. Volatile Organic Compounds $(VOC_s)$ and formaldehyde have been considered as one of the main reason that causes indoor air pollutant. This study is for introducing and designing thermal performance of super energy saving building by conducting $VOC_s$ and formaldehyde concentration in the 3Liter house. The results of the measurement for 10 months showed that $VOC_s$ and formaldehyde decreased until the guideline concentration. It took about 7 months, and it appeared right after new construction. However, their levels were showed higher concentration in comparison with the ordinary residential houses (apartment house). The main difference of between newly built 3Liter house and ordinary apartment is their air changes, which are 0.67/h for 3Liter house and 4.0/h for the apartment.
Keywords
3Liter House; Air tightness; Volatile Organic Compounds; Formaldehyde; Concentration Transition;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Wolfgang Feist (2004), Passive House Planning Package, PHI
2 Retrotec, '2000 Series Door Fan Manual For Energy, Scientific and Industrial Users', Retrotec
3 Wolfgang Feist (2001), CEPHEUS-Projet information N0.36, PHI
4 Wolfgang Feist (2005), CEPHEUS-Projet information N0.1-Climate Neutral Passive House Estate in Hannoverkronsberg; Construction and Measurement Results
5 원종서.박선효.박용승(2005), 3리터 하우스 설계를 위한 건축요소의 에너지성능 평가, 대한건축학회 추계학술발표대회논문집, 25(1), 19-22
6 문현준(2006), 에너지 절약 주택과 일반 주택에서의 TVOC 농도 비교분석, 대한건축학회논문집, 22(4), 269-276
7 유복희.(2007), 3리터 하우스에서의 VOC 및 포름 알데히드 농도변화 특성, 한국생태건축학회 학술발표대회논문집, 7(1), 247-250
8 박선효.원종서.조재훈(2007), 기밀 시공 관리에 다른 건물의 기밀도 현황 연구, 한국생태건축학회 학술발표대회논문집, 7(1), 81-84
9 구성한.조재훈.여명석.김광우(2004), 실측을 통한 초고층 주거건물의 기밀도 특성에 관한 연구, 대한건축학회 학술발표대회논문집, 24(1), 757-760
10 이윤규.김창남(2004), 기존 공동주택의 실내공기질 실태에 관한 측정연구, 대한건축학회논문집, 20(11), 327-334
11 American Society of Heating (2001), Refrigerating and Air Conditioning Engineers, Inc., 2001 ASHRAE Handbook Fundamentals, ASHRAE, Atlanta, GA
12 Jurgen Shnieders (2003), CEPHEUS-measurement results from more than 100 dwelling units in passive houses, ECEEE