• Title/Summary/Keyword: embedded testing

Search Result 411, Processing Time 0.026 seconds

Implementation of a Low-cost Virtual Reality System Using Smart Phone (스마트폰을 이용한 저가 VR 시스템 구현에 관한 연구)

  • Lim, Eun-Su;Yun, Sung-Yi;Ko, Yong-Suk;Jung, Ha-Young;Choi, Hong-Sub
    • Journal of Digital Contents Society
    • /
    • v.19 no.7
    • /
    • pp.1237-1244
    • /
    • 2018
  • Currently the bottleneck in virtual reality's commercialization might be that high cost VR equipment is needed and interesting VR contents are not enough. The purpose of this paper is to solve these problems by implementing low-cost VR system with wireless controller and HMD(Head Mounted Display) using a smart phone and PC. The functions of real HMD are simulated by utilizing the display and embedded sensors of a smart phone. In that situation PC is in charge of processing huge data and is communicated with smart phone. And wireless controller is designed to make VR user's movement to be free. In addition, we made the several VR contents for testing our prototype system directly. Easy access to VR equipment could induce increasing number of users and investment. And it will be a big step toward improving VR technology and its commercialization.

COMPARATIVE STUDY ON THE FRACTURE STRENGTH OF METAL-CERAMIC VERSUS COMPOSITE RESIN-VENEERED METAL CROWNS IN CEMENT-RETAINED IMPLANT-SUPPORTED CROWNS UNDER VERTICAL COMPRESSIVE LOAD

  • Pae, Ahran;Jeon, Kyung-A;Kim, Myung-Rae;Kim, Sung-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.3
    • /
    • pp.295-302
    • /
    • 2007
  • Statement of problem. Fracture of the tooth-colored superstructure material is one of the main prosthetic complications in implant-supported prostheses. Purpose. The purpose of this in vitro study was to compare the fracture strength between the cement-retained implant-supported metal-ceramic crowns and the indirect composite resinveneered metal crowns under the vertical compressive load. Material and methods. Standard implants of external type (AVANA IFR 415 Pre-mount; Osstem Co., Busan, Korea) were embedded in stainless steel blocks perpendicular to their long axis. Customized abutments were fabricated using plastic UCLA abutments (Esthetic plastic cylinder; Osstem Co., Busan, Korea). Thirty standardized copings were cast with non-precious metal (Rexillium III, Pentron, Walling ford, Conn., USA). Copings were divided into two groups of 15 specimens each (n = 15). For Group I specimens, metal-ceramic crowns were fabricated. For Group II specimens, composite resin-veneered (Sinfony, 3M-ESPE, St. Paul, MN, USA) metal crowns (Sinfony-veneered crowns) were fabricated according to manufacturer's instructions. All crowns were temporary cemented and vertically loaded with an Instron universal testing machine (Instron 3366, Instron Corp., Norwood, MA, USA). The maximum load value (N) at the moment of complete failure was recorded and all data were statistically analyzed by independent sample t-test at the significance level of 0.05. The modes of failure were also investigated with visual analysis. Results. The fracture strength of Sinfony-veneered crowns ($2292.7{\pm}576.0N$) was significantly greater than that of metal-ceramic crowns ($1150.6{\pm}268.2N$) (P < 0.05). With regard to the failure mode, Sinfony-veneered crowns exhibited adhesive failure, while metal-ceramic crowns tended to fracture in a manner that resulted in combined failure. Conclusion. Sinfony-veneered crowns demonstrated a significantly higher fracture strength than that of metal-ceramic crowns in cement-retained implant-supported prostheses.

Improvement of pavement foundation response with multi-layers of geocell reinforcement: Cyclic plate load test

  • Khalaj, Omid;Tafreshi, Seyed Naser Moghaddas;Mask, Bohuslav;Dawson, Andrew R.
    • Geomechanics and Engineering
    • /
    • v.9 no.3
    • /
    • pp.373-395
    • /
    • 2015
  • Comprehensive results from cyclic plate loading at a diameter of 300 mm supported by layers of geocell are presented. The plate load tests were performed in a test pit measuring $2000{\times}2000mm$ in plane and 700 mm in depth. To simulate half and full traffic loadings, fifteen loading and unloading cycles were applied to the loading plate with amplitudes of 400 and 800 kPa. The optimum embedded depth of the first layer of geocell beneath the loading plate and the optimum vertical spacing of geocell layers, based on plate settlement, are both approximately 0.2 times loading plate diameter. The results show that installation of the geocell layers in the foundation bed, increase the resilient behavior in addition to reduction of accumulated plastic and total settlement of pavement system. Efficiency of geocell reinforcement was decreased by increasing the number of the geocell layers for all applied stress levels and number of cycles of applied loading. The results of the testing reveal the ability of the multiple layers of geocell reinforcement to 'shakedown' to a fully resilient behavior after a period of plastic settlement except when there is little or no reinforcement and the applied cyclic pressure are large. When shakedown response is observed, then both the accumulated plastic settlement prior to a steady-state response being obtained and the resilient settlements thereafter are reduced. The use of four layers of geocell respectively decreases the total and residual plastic settlements about 53% and 63% and increases the resilient settlement 145% compared with the unreinforced case. The inclusion of the geocell layers also reduces the vertical stress transferred down through the pavement by distributing the load over a wider area. For example, at the end of the load cycle of the applied pressure of 800 kPa, the transferred pressure at the depth of 510 mm is reduced about 21.4%, 43.9%, 56.1% for the reinforced bases with one, two, and three layers of geocell, respectively, compared to the stress in the unreinforced bed.

Design of Stack Monitoring System with Improved Performance (성능이 향상된 Stack Monitoring System의 설계)

  • Jang, Kyeong-Uk;Lee, Joo-Hyun;Lee, Seong-Won;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.20 no.3
    • /
    • pp.299-302
    • /
    • 2016
  • In this paper, we designed the stack monitoring system with improved performance. To block the incoming pulse noise to the amplifier, shield and the power supply impedance are reduced and the power circuit is isolated. The control unit is developed with variable high voltage, adaptive gain, offset and threshold in order to match the scintillation detector characteristic to the apparatus. 300-1500V variable high voltage power circuit is configured applicable to various scintillation detector. Stack monitoring system with improved performance guarantee the efficiency and the reliability by considering the characteristic of various scintillation detector. Developed stack monitoring system is evaluated with certified testing equipment and shows excellent performance with respect to the uncertainty of the sensor test results.

Shear bond strength of resin cement to an acid etched and a laser irradiated ceramic surface

  • Kursoglu, Pinar;Karagoz Motro, Pelin Fatma;Yurdaguven, Haktan
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.2
    • /
    • pp.98-103
    • /
    • 2013
  • PURPOSE. To evaluate the effects of hydrofluoric acid etching and Er,Cr:YSGG laser irradiation on the shear bond strength of resin cement to lithium disilicate ceramic. MATERIALS AND METHODS. Fifty-five ceramic blocks ($5mm{\times}5mm{\times}2mm$) were fabricated and embedded in acrylic resin. Their surfaces were finished with 1000-grit silicon carbide paper. The blocks were assigned to five groups: 1) 9.5% hydrofluoric-acid etching for 60 s; 2-4), 1.5-, 2.5-, and 6-W Er,Cr:YSGG laser applications for 60 seconds, respectively; and 5) no treatment (control). One specimen from each group was examined using scanning electron microscopy. Ceramic primer (Rely X ceramic primer) and adhesive (Adper Single Bond) were applied to the ceramic surfaces, followed by resin cement to bond the composite cylinders, and light curing. Bonded specimens were stored in distilled water at $37^{\circ}C$ for 24 hours. Shear bond strengths were determined by a universal testing machine at 1 mm/min crosshead speed. Data were analyzed using Kruskal-Wallis and Mann-Whitney U-tests (${\alpha}$=0.05). RESULTS. Adhesion was significantly stronger in Group 2 ($3.88{\pm}1.94$ MPa) and Group 3 ($3.65{\pm}1.87$ MPa) than in Control group ($1.95{\pm}1.06$ MPa), in which bonding values were lowest (P<.01). No significant difference was observed between Group 4 ($3.59{\pm}1.19$ MPa) and Control group. Shear bond strength was highest in Group 1 ($8.42{\pm}1.86$ MPa; P<.01). CONCLUSION. Er,Cr:YSGG laser irradiation at 1.5 and 2.5 W increased shear bond strengths between ceramic and resin cement compared with untreated ceramic surfaces. Irradiation at 6 W may not be an efficient ceramic surface treatment technique.

Quality Improvements of Breast Specimen Fixation for Histopathology Test (병리검사를 위한 유방검체 고정의 질 향상 활동)

  • Cho, Seong-Il;Choi, Myung-Sup;Bae, Moon-Hwan;Lee, Moon-Jung;Woo, Hee-Suck;Park, Soon-Chae;Cho, Eun-Yoon
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.42 no.3
    • /
    • pp.149-154
    • /
    • 2010
  • To improve accuracy of the immunohistochemical testing and fluorescence in situ hybridization (FISH) study as well as a routine histology diagnosis in breast cancer, quality improvement for optimal tissue handling is mandatory. We evaluate fraction defective of 7107 blocks from 349 breast cancer patients, who underwent surgical treatment at Samsung Medical Center Seoul, Korea from January 1, 2009 to March 31, 2010. We decided pre-improvement period from January, 2009 to June, 2009. In the first quality improvement period (July, 2009 to September, 2009) we made improvements in protocol of gross examination. In the second quality improvement period (October, 2009 to December, 2009) we attempted more effective formalin fixation such as frequent exchange of formalin and use of separate fixation container for each case. In the third quality improvement period (January, 2010 to March, 2010) improvement of tissue processor was performed. We achieved a marked reduction of fraction defective (9-16%) through efforts to improve quality of formalin-fixed, paraffin-embedded blocks when compared to pre-improvement period.

  • PDF

Performance Evaluation of I/O Intensive Stress Test in Cluster File System SANiqueTM (집중적인 입출력 스트레스 테스트를 통한 클러스터 파일 시스템 SANiqueTM의 성능평가)

  • Lee, Kyu-Woong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.2
    • /
    • pp.415-420
    • /
    • 2010
  • This paper describes the design overview of shared file system $SANique^{TM}$ and analyzes the performance evaluation results of I/O intensive stress test based on various cluster file system architectures. Especially, we illustrate the performance analysis for the comparison results between the $SANique^{TM}$ and the Linux file system EXT3 system that is used to generally in Unix world. In order to perform our evaluation, Oracle 10g database system is operated on the top of cluster file system, and we developed the various kinds of testing tools which are compiled by ESQL/C from Oracle. Three types of architectures are used in this performance evaluation. Those are the cluster file system $SANique^{TM}$, EXT3 and the combined architecture of $SANique^{TM}$ and EXT3. In this paper, we present that the results of $SANique^{TM}$ outperforms other cluster file systems in the overhead for providing the true sharing over the connecting server nodes.

Development of FPGA Based HIL Simulator for PMS Performance Verification of Natural Liquefied Gas Carriers (액화천연가스운반선의 PMS 성능 검증을 위한 FPGA 기반 HIL 시뮬레이터 개발)

  • Lee, Kwangkook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.7
    • /
    • pp.949-955
    • /
    • 2018
  • Hardware-in-the-loop (HIL) simulation is a technique that can be employed for developing and testing complex real-time embedded systems. HIL simulation provides an effective platform for verifying power management system (PMS) performance of liquefied natural gas carriers, which are high value-added vessels such as offshore plants. However, HIL tests conducted by research institutes, including domestic shipyards, can be protracted. To address the said issue, this study proposes a field programmable gate array (FPGA) based PMS-HIL simulator that comprises a power supply, consumer, control console, and main switchboard. The proposed HIL simulation platform incorporated actual equipment data while conducting load sharing PMS tests. The proposed system was verified through symmetric, asymmetric, and fixed load sharing tests. The proposed system can thus potentially replace the standard factory acceptance tests. Furthermore, the proposed simulator can be helpful in developing additional systems for vessel automation and autonomous operation, including the development of energy management systems.

Methylation Abnormality in Body Fluid Cytology: A Supplemental Molecular Marker for the Diagnosis of Malignant Mesothelioma (체액 세포 도말 검사에서 메틸화 이상이 악성 중피종 진단의 부가적인 분자 표지자로서의 기능)

  • Song, Joon-Seon;Jung, Jin-Kyung;Kang, Ji-Hye;Hwang, Il-Seon;Jang, Se-Jin
    • The Korean Journal of Cytopathology
    • /
    • v.19 no.2
    • /
    • pp.126-135
    • /
    • 2008
  • Malignant mesothelioma (MM) is a highly lethal neoplasm arising in pleura and the peritoneum and a rapid and accurate diagnosis is crucial for treatment of the disease. However, the sensitivity of cytological analysis using pleural or ascitic fluid is relatively low, yielding an accurate diagnosis in only $32{\sim}79%$ of cases. We tested the diagnostic value of epigenetic alterations in body fluid cytology as a supplement to conventional methods. Paraffin-embedded tissue blocks from 21 MM patients and associated body fluid cytology slides considered no evidence of malignancy were used to test for epigenetic alteration. Using methylation-specific PCR, we detected methylation of RASSF1A and p16 in 47.6% (10/21) of both surgically resected tumor samples, respectively. Body fluid samples of MM also showed abnormal methylation of RASSF1A and p16INK4a genes in 38.1% (8/21) and 33.3% (7/21) of cases. The concordance in the rates of RASSF1A and p16INK4a gene-methylation abnormalities determined from cytology samples and tissue samples were 61.9% (13/21) and 66.7% (14/21), respectively. Combining both genes increases the sensitivity of the test to 57.1 % (12 of 21) of cases. Our results suggest that testing for methylation abnormalities in selected individual genes or gene combinations has diagnostic value as an alternative or adjunct method to conventional cytological diagnosis.

Effect of ultrasonic tip designs on intraradicular post removal

  • Aguiar, Anny Carine Barros;de Meireles, Daniely Amorim;Marques, Andre Augusto Franco;Sponchiado, Emilio Carlos Junior;Garrido, Angela Delfina Bitencourt;Garcia, Lucas Da Fonseca Roberti
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.4
    • /
    • pp.265-269
    • /
    • 2014
  • Objectives: To evaluate the effect of different ultrasonic tip designs on intraradicular post removal. Materials and Methods: The crowns of forty human canine teeth were removed, and after biomechanical preparation and filling, the roots were embedded in acrylic resin blocks. The post spaces were made, and root canal molding was performed with self-cured acrylic resin. After casting (Cu-Al), the posts were cemented with zinc phosphate cement. The specimens were randomly separated into 4 groups (n = 10), as follows: G1 - no ultrasonic vibration (control); G2 - ultrasonic vibration using an elongated cylindrical-shaped and active rounded tip; G3 - ultrasonic vibration with a flattened convex and linear active tip; G4 - ultrasonic vibration with active semicircular tapered tip. Ultrasonic vibration was applied for 15 seconds on each post surface and tensile test was performed in a Universal Testing Machine (Instron 4444 - 1 mm/min). Results: G4 presented the highest mean values, however, with no statistically significant difference in comparison to G3 (p > 0.05). G2 presented the lowest mean values with statistically significant difference to G3 and G4 (p < 0.05). Conclusions: Ultrasonic vibration with elongated cylindrical-shaped and active rounded tip was most effective in reducing force required for intraradicular post removal.