• Title/Summary/Keyword: elongated field

Search Result 50, Processing Time 0.03 seconds

Application of the Equivalent-Field Method for Output Calculation: Is it safe for elongated x-ray fields\ulcorner (출력인자 계산에 이용되는 등가면법의 타당성 연구 : 장방형 X-선 조사면에 대해서 안전한가\ulcorner)

  • Kim, Chang-Seon;Kim, Chul-Yong;Park, Myung-Sun
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.195-200
    • /
    • 1998
  • Purpose: When an elongated x-ray field is used for treating a patient, the equivalent- field method is commonly used for the output calculation. This study is intended for investigating potential factors such as, beam quality, field elongation ratio, and depth of measurement, which might effect on the applicability of the equivalent square technique for output calculation. The derivation of a 'rule of thumb' for the application criteria of the equivalent-field method is also aimed. Materials and Methods: Three x-ray beams, 4-, 6- and 10-MV, were employed for this study. Width of the rectangular field was ranged from 5-40 cm and the elongation ratio (length/width) 1:0 to 10:0. An elongation effect was measured in a water phantom at three different depths, dmax, 5-cm, and 10-cm. For an elongated field and its equivalent square field, the output factor was measured and the difference in the output factor were examined between two fields. Results and Discussions: As the elongation ratio increases, a larger discrepancy in outputs is observed between the elongated rectangular field and its corresponding equivalent square field. Output was measured larger for an elongated field than for its corresponding equivalent square field and the maximal difference over 10 % was found. The difference was found larger for the smaller field with the same elongation ratio. The effect of the beam quality and the depth of measurement on the output difference was minimal. Conclusion: Based on the study, there is criteria for the application of the method for output calculation. For the combination of long axis and elongation ratio whose relationship satisfies Elongation ratio < (0.48) (Long axis) - 0.5, the equivalent-field method is valid for output calculation within 2 % for the field whose long axis < 25-cm. For other combinations, instead of using the equivalent-field method, direct output measurement is recommended. This criteria can be applied for 4-10 MV x-ray beams up to 10-cm depth.

  • PDF

Effective Volume of the Korea Research Institute of Standards and Science Free Air Chamber L1 for Low-Energy X-Ray Measurement

  • Chul-Young Yi;Yun Ho Kim;Don Yeong Jeong
    • Progress in Medical Physics
    • /
    • v.33 no.1
    • /
    • pp.1-9
    • /
    • 2022
  • Purpose: To evaluate the effective volume of the Korea Research Institute of Standards and Science free air chamber (KRISS FAC) L1 used for the primary standard device of the low-energy X-ray air kerma. Methods: The mechanical dimensions were measured using a 3-dimensional coordinate measuring machine (3-d CMM, Model UMM 500, Carl Zeiss). The diameter of the diaphragm was measured by a ring gauge calibrator (Model KRISS-DM1, KRISS). The elongation of the collector length due to electric field distortion was determined from the capacitance measurement of the KRISS FAC considering the result of the finite element method (FEM) analysis using the code QuickField v6.4. Results: The measured length of the collector was 15.8003±0.0014 mm with a 68% confidence level (k=1). The aperture diameter of the diaphragm was 10.0021±0.0002 mm (k=1). The mechanical measurement volume of the KRISS FAC L1 was 1.2415±0.0006 cm3 (k=1). The elongated length of the collector due to the electric field distortion was 0.170±0.021 mm. Considering the elongated length, the effective measurement volume of the KRISS FAC L1 was 1.2548±0.0019 cm3(k=1). Conclusions: The effective volume of the KRISS FAC L1 was determined from the mechanically measured value by adding the elongated volume due to the electric field distortion in the FAC. The effective volume will replace the existing mechanically determined volume in establishing and maintaining the primary standard of the low-energy X-ray.

Carbon Nanotube Gate-Elongated Tunneling Field Transistor(CNT G-E TFET) to Reduce Off-Current

  • Heo, Jae;Jeon, Seung-Bae
    • Proceeding of EDISON Challenge
    • /
    • 2013.04a
    • /
    • pp.240-242
    • /
    • 2013
  • In this paper, novel Carbon Nanotube Gate-Elongated Tunneling Field Transistor(CNT G-E TFET) is proposed. This proposed device is designed to decrease off-current around 2~6 orders of magnitude compared to the gate-channel size matched TFET. Mechanism of CNT G-E TFET creates additional steps in energy band structure so that off-current can be reduced. Since CNT TFETs show a great probability for tunneling processes and they are beneficial for the overall device performance in terms of switching speed and power consumption, CNT G-E TFET looks pretty much promising.

  • PDF

The efficacy of elongated axillary incision on extended latissimus dorsi flap for immediate breast reconstruction

  • Park, Tae Seo;Nam, Su Bong;Choi, Jae Yeon;Bae, Sung Hwan;Lee, Jae Woo;Kim, Hyun Yul
    • Archives of Plastic Surgery
    • /
    • v.45 no.4
    • /
    • pp.340-344
    • /
    • 2018
  • Background In performing extended latissimus dorsi (ELD) flap procedures, a skin paddle design on the bra line helps reduce visible scarring. This improves the patient's satisfaction with the outcome. However, such a design leads to a longer operation time and increased fatigue of the surgeon due to the narrow operative field. In this study, the authors propose a method that elongates the axillary incision line posteriorly by 1.5 cm from the lateral border of the latissimus dorsi muscle. We examined whether this method could shorten the operation time and compared the incidence of complications between patients who underwent this novel procedure and patients who underwent the traditional procedure. Methods In this study of patients who underwent ELD flap procedures for immediate breast reconstruction, 89 underwent surgery with the elongated axillary incision and 45 underwent surgery without the elongated incision. The total operation time and complications were retrospectively examined based on the patients' medical records, and we examined whether there was any statistically significant difference in the total operation time. Results In the experimental group with the elongated axillary incision, the operation time ranged from 125 to 255 minutes (median, 175 minutes). In contrast, in the control group without the elongated axillary incision, the operation time ranged from 142 and 340 minutes (median, 205 minutes). The operation time was statistically significantly different between the two groups, and no significant complications were observed in the experimental group. Conclusions Elongation of the axillary incision alone may shorten the operation time of the ELD flap procedure without causing additional complications.

Fermi Large Area Telescope Observations of the Dark Accelerator HESS J1745-303

  • Yeung, Paul
    • Journal of Astronomy and Space Sciences
    • /
    • v.33 no.4
    • /
    • pp.319-321
    • /
    • 2016
  • Reviewing the two MeV-GeV investigations in the field of the HESS J1745-303 performed using Fermi Large Area Telescope data, we confirmed that the emission peak comfortably coincides with 'Region A' in the TeV regime, which is the brightest part of this feature. The MeV-TeV spectrum can be precisely described by a single power-law. Also, recent investigation has shown that the MeV-GeV feature is elongated from 'Region A' toward the north-west, which is similar to the case of largescale atomic/molecular gas distribution.

Morphology and Swelling Behaviors of PVA/Gelatin Blend Membranes Prepared Under High Electric Field (고전장하에서 제조된 PVA/Gelatin 블렌드막의 구조와 팽윤거동)

  • Huh, Yang-Il;Yun, Hyung-Ku
    • Polymer(Korea)
    • /
    • v.30 no.6
    • /
    • pp.563-567
    • /
    • 2006
  • Poly(vinyl alcohol) (PVA) and gelatin (GEL) blend membranes were prepared by solution casting method under a high electric field. SEM observation of the membrane showed that gelatin rich domains were elongated and oriented to the direction of the applied electric field in PVA matrix. This can be attributed to the electrostatic emulsifying effects due to a reduction in interfacial tension. In addition, it was observed through WAXD and swelling measurements that the degree of crystallinity of membranes increased with applied electric field strength. This may be interpreted to be caused by the orientation effect of GEL domains in the blend membrane, and the self-annealing effect due to some heat generated from high electric field during casting.

TIDAL TAILS OF GLOBULAR CLUSTERS

  • YIM KI-JEONG;LEE HYUNG MOK
    • Journal of The Korean Astronomical Society
    • /
    • v.35 no.2
    • /
    • pp.75-85
    • /
    • 2002
  • We present N-body simulations of globular clusters including gravitational field of the Galaxy, in order to study effects of tidal field systematically on the shape of outer parts of globular clusters using NBODY6. The Galaxy is assumed to be composed of central bulge and outer halo. We mvestigate the cluster of multi-mass models with a power-law initial mass function (IMF) starting with different initial masses, initial number of particles, different slopes of the IMF and different orbits of the cluster. We have examined the general evolution of the clusters, the shape of outer parts of the clusters, density profiles and the direction of tidal tails. The density profiles appear to become somewhat shallower just outside the tidal boundary consistent with some observed data. The position angle of the tidal tall depends on the location in the Galaxy as well as the direction of the motion of. clusters. We found that the clusters become more elongated at the apogalacticon than at the pengalacticon. The tidal tails may be used to trace the orbital paths of globular clusters.

A Study on the Bubble Deformation and Departure Under DC Electric Field (직류전기장에 의한 기포의 변형과 이탈에 관한 연구)

  • 권영철;김무환;강인석;김석준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.6
    • /
    • pp.1518-1528
    • /
    • 1995
  • The deformation and departure processes of a bubble attached to the wall are studied experimentally and numerically to understand the phenomena of the nucleate boiling heat transfer enhancement under DC electric field. An air-bubble is injected in a dielectric liquid with different electric fields generated by changing three types of electrode system (Type 1,2 and 3) in the bubble generator. Experimental variables are the electric field strength and the distance and the shape of the electrodes under DC electric field. From experimental results, it is observed that the bubble under Dc electric field is elongated in the same direction as the electric field and the contact angle increases. For the parallel plate electrode which generates a uniform electric field, bubble departure volume doesn't seem to decrease within our experimental range. However, when a needle is raised a few millimeters from the lower electrode to make a nonuniform electric field around the needle, bubble departure volume decreases continuously with the increase of an applied voltage. The reduction effect of bubble departure volume is the most effective under a strong nonuniform electric field generated with Type 3. As the nonuniformity of the electric field due to the shape of a electrode increases, the terminal velocity and the acceleration of a bubble increase largely. For the comparison with visualization results, the deformation of a bubble attached to the electrode is carried out by a numerical method. Numerical results show good agreement qualitatively with experimental results.

Abell 2261: a fossil galaxy cluster in a transition phase

  • Kim, Hyowon;Ko, Jongwan;Kim, Jae-woo;Smith, Rory;Song, Hyunmi;Hwang, Ho Seong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.1
    • /
    • pp.58.2-58.2
    • /
    • 2018
  • Fossil groups of galaxies have characteristic features of a dominant central elliptical galaxy (${\Delta}M_{12}$ > 2 in $0.5R_{vir}$) embedded in highly relaxed X-ray halo, which indicates dynamically stable and evolved systems. These are thought as a final stage of the evolution of galaxy groups in the hierarchical structure formation scenario. However, the formation and evolution of fossil clusters are still unclear due to lack of detailed studies. Therefore, we perform a kinematic research of a known fossil cluster Abell 2261 (A2261 hereafter) using spectroscopic data of 589 galaxies in the A2261 field. Even though A2261 is known as a fossil cluster, previous studies found several unusual features such as quite high X-ray entropy for a stable cluster, and an elongated shape, which are not expected in standard fossil clusters. Using the caustic method, we identify cluster member galaxies and discover a second bright galaxy (${\Delta}M_{12}=1.68$) at ${\sim}1.5R_{vir}$. The presence of such a bright galaxy can break the current fossil state of cluster in the near future. In addition, with two independent substructure finding methods, we confirm that the previously detected elongated galaxy distribution of the cluster is a real feature. These findings indicate that A2261 is not in a fully stable state, unlike the existing fossil definition diagnostic. We require a more stringent criterion for the fossil definition to represent a genuinely final stage of cluster evolution.

  • PDF

Transmission Dose Estimation Algorithm for in vivo Dosimetry

  • Yun, Hyong-Geun;Huh, Soon-Nyung;Lee, Hyoung-Koo;Woo, Hong-Gyun;Shin, Kyo-Chul;Ha, Sung-Whan
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.1
    • /
    • pp.59-63
    • /
    • 2003
  • Purpose : Measurement of transmission dose is useful for in vivo dosimetry of QA purpose. The objective of this study is to develope an algorithm for estimation of tumor dose using measured transmission dose for open radiation field. Materials and Methods : Transmission dose was measured with various field size (FS), phantom thickness (Tp), and phantom chamber distance (PCD) with a acrylic phantom for 6 MV and 10 MV X-ray Source to chamber distance (SCD) was set to 150 cm. Measurement was conducted with a 0.6 cc Farmer type ion chamber. Using measured data and regression analysis, an algorithm was developed for estimation of expected reading of transmission dose. Accuracy of the algorithm was tested with flat solid phantom with various settings. Results : The algorithm consisted of quadratic function of log(A/P) (where A/P is area-perimeter ratio) and tertiary function of PCD. The algorithm could estimate dose with very high accuracy for open square field, with errors within ${\pm}0.5%$. For elongated radiation field, the errors were limited to ${\pm}1.0%$. Conclusion : The developed algorithm can accurately estimate the transmission dose in open radiation fields with various treatment settings.