• Title/Summary/Keyword: electronic equipment

Search Result 1,548, Processing Time 0.029 seconds

Investigation on propagation characteristics of AE signal with FEM (FEM을 이용한 음향신호의 전달특성에 관한 연구)

  • Seo, Pan-Seok;Koo, Kyung-Wan;Kim, Jong-Seok;Han, Sang-Ok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.274-277
    • /
    • 2001
  • This paper describes the simulation study. conducted on the propagation characteristics of AE signal. In the case of gas insulation, such as $SF_6$, the equipment is less affected by the environment condition than air insulation, because the component parts of equipment were placed in the enclosure, which is filled with compressed gas. But. when the breakdown in the electric insulation occurs. it takes much time and economical efforts to repair. Therefore it is very important to diagnose the equipment before the accident. And. in general. UHF and AE signal is the most common transducer to diagnose the state of the power equipment, so, in this investigation, we make a experimental apparatus with aluminum plate and transient analysis with ANSYS to observe the propagation characteristics of AE signal. Through the result of the analysis. we can make a further understanding on the propagation characteristics of AE signal, and get the fundamental skills for the GIS diagnosis.

  • PDF

Investigation on propagation characteristics of AE signal with FEM (FEM을 이용한 음향신호의 전달특성에 관한 연구)

  • 서판석;구경완;김종석;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.274-277
    • /
    • 2001
  • This paper describes the simulation study, conducted on the propagation characteristics of AE signal. In the case of gas insulation, such as SF6, the equipment is less affected by the environment condition than air insulation, because the component parts of equipment were placed in the enclosure, which is filled with compressed gas. But, when the breakdown in the electric insulation occurs, it takes much time and economical efforts to repair. Therefore it is very important to diagnose the equipment before the accident. And, in general, UHF and AE signal is the most common transducer to diagnose the state of the power equipment, so, in this investigation, we make a experimental apparatus with aluminum plate and transient analysis with ANSYS to observe the propagation characteristics of AE signal. Through the result of the analysis, we can make a further understanding on the propagation characteristics of AE signal, and get the fundamental skills for the GIS diagnosis.

  • PDF

Development of Heat System for Productivity Improvement of Ball Press Pushing up Equipment (볼 프레스 압입장치의 생산성 향상을 위한 예열시스템 개발)

  • Chai, Yong-Yoong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.11
    • /
    • pp.1101-1106
    • /
    • 2016
  • In this thesis, I developed a ball press pushing up equipment to solve the defect that occurs when the ball is inserted to the auto transmission. The ball press pushing up equipment is composed of heating device, thermostat which controls the heating device and the automated insertion device which helps to enhance mass production. This development contributes to quality improvement of domestic automobile production auto transmission part, and also contribute to cost reduction and sales increase for corporations.

Efficient Multi-site Testing Using ATE Channel Sharing

  • Eom, Kyoung-Woon;Han, Dong-Kwan;Lee, Yong;Kim, Hak-Song;Kang, Sungho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.3
    • /
    • pp.259-262
    • /
    • 2013
  • Multi-site testing is considered as a solution to reduce test costs. This paper presents a new channel sharing architecture that enables I/O pins to share automatic test equipment (ATE) channels using simple circuitry such as tri-state buffers, AND gates, and multiple-input signature registers (MISR). The main advantage of the proposed architecture is that it is implemented on probe cards and does not require any additional circuitry on a target device under test (DUT). In addition, the proposed architecture can perform DC parametric testing of the DUT such as leakage testing, even if the different DUTs share the same ATE channels. The simulation results show that the proposed architecture is very efficient and is applicable to both wafer testing and package testing.

Experiments on the Heat Transfer and Pressure Drop Characteristics of a Channel with Pin-Fin Array (핀-휜을 삽입한 채널의 열전달 및 압력강하 특성 실험)

  • 신지영;손영석;김상민;이대영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.7
    • /
    • pp.623-629
    • /
    • 2004
  • Rapid development of electronic technology requires small size, high density packaging and high power of electronic devices, which result in more heat generation by the electronic system. Present cooling technology may not be adequate for the thermal management in the current state-of-the-art electronic equipment. Forced convective heat transfer in a channel filled with pin-fin array is studied experimentally in this paper as an alternative cool-ing scheme for a high heat-dissipating equipment. Various configurations of the pin-fin array are selected in order to find out the effect of spacing and diameter of the pin-fin on the heat transfer and pressure drop characteristics. In the low porosity region, interfacial heat transfer and pressure drop seem to show different trend compared to the conventional heat transfer process.

Efficient Approaches of Functional Safety for Medical Equipment using Essential Performance Analysis (필수성능 분석을 통한 효율적인 의료기기 기능안전 접근 방안)

  • Kim, Gi-Young;Yoo, Ki-Hoon;Park, Ho-Joon;Jang, Joong-Soon
    • Journal of Applied Reliability
    • /
    • v.15 no.1
    • /
    • pp.27-32
    • /
    • 2015
  • Functional safety is part of the overall safety relating to the equipment under control (EUC) and the EUC control system that depends on the correct functioning of the electrical/electronic/programmable electronic (E/E/PE) safety-related systems. Since the complexity of the medical equipment is increased, manufactures have to obtain functional safety as well as basic safety. This study proposes a perspective for applying functional safety to medical equipment. The research is carried out with respect to overall safety life-cycle of functional safety and essential performance of the medical equipment. The relationship between functional safety and essential performance is identified centered on the safety function. The essential performance using E/E/PE systems is defined as a safety function of functional safety. This approach is applied to a ultrasound imaging system as a case study.

A Study on Ensuring the Safety of Potable UV Space Germicidal Equipment (이동형 UV 공간 살균 기기의 안전성 확보 방안에 관한 연구)

  • Han-Seok Cheong;Chung-Hyeok Kim;Jin-Sa Kim
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.37 no.1
    • /
    • pp.94-100
    • /
    • 2024
  • Recently, as interest in personal hygiene has increased due to the community spread of COVID-19 and variant viruses, fixed and potable UV germicidal equipment to sterilize indoor spaces and hand-held UV germicidal equipment to sterilize household items such as masks and mobile phones are continuously being developed and sold. However, the development and sales of the product are difficult because appropriate testing methods have not yet been established. In this situation, if an uncertified product is distributed in the market, it can cause serious harm to consumers. In this study, we investigate the photobiological risks and safety devices against UV exposure of UV germicidal equipment distributed domestically, and propose appropriate test methods for portable UV germicidal equipment based on the research results.

A Study on the Establishment of the Standards for the Recycling Rate of Parts and Materials to Calculate Recyclability Rate of Electrical and Electronic Equipments (전기전자제품의 재활용가능률 산정을 위한 부품/소재의 재활용기준 정립에 관한 연구)

  • Yi, Hwa-Cho;Kang, Hong-Yun;Kim, Jin-Han;Shim, Kang-Sik;Kim, Jin-Ho;Han, Seong-Chul
    • Clean Technology
    • /
    • v.14 no.4
    • /
    • pp.232-241
    • /
    • 2008
  • European directive DIRECTIVE 2002/96/EC requires minimum recycling & recovery rates on waste electrical and electronic equipment (WEEE). We tried to make references for recycling and recovery rates of parts and materials used in electrical and electronic equipment (EEE), which could be used to calculate recyclability and recoverability rates of a product in the development phase. First, we investigated recycling processes of WEEE and recycling and recovery characteristics of parts and materials. Based on the investigation results and the european recycling data, we made a data base of parts and materials for calculation of recycling and recovery rates of EEE. The developed DB was improved by reflecting advices of european experts.

  • PDF

Improvement Plan for Calculation of Financial Contributions to Treatment of Waste Electrical and Electronic Equipments (폐전기·전자제품 처리에 대한 분담금 산정의 개선방안)

  • Kim, Han-Soo;Kim, Dae-Bong
    • Resources Recycling
    • /
    • v.29 no.4
    • /
    • pp.45-50
    • /
    • 2020
  • Producer and distributor of electrical and electronic equipment may directly collect waste electrical and electronic equipment that falls under the class to which the equipment they distributed belongs, or may join KERC(Korea Electronic Recycling Cooperative) and have KERC fulfill the duty to collect on behalf. In this study, the system of calculating the financial contributions is reviewed, and then the defined problems and improvement plan are proposed. First, the standard operation and time should be set for collection and transportation costs, taking into account the operation by collection type. Second, since there is a difference in the screening method of the recycling center, the standard cost for the allocation factor should be set by reflecting the difference in these methods and the characteristics of the product line being processed. Third, it is necessary to secure a budget of sufficient size by determining the median or average value rather than the minimum value in the forecast model for visit collection. This study is suggesting in that it examines the problems of the allotted contributions paid by the mutual aid members to KERC and suggests ways to improve them.

A Study of Laboratory Facilities, Equipment and Expenses for Practice in a Four-year Nursing Schools (4년제 간호대학(과) 실습 비 및 실습기자재 표준안 개발을 위한 기초조사연구)

  • Shin, Kyung-Rim;Park, Kyung-Sook;Ahn, Yang-Heui;Chaung, Seung-Kyo;Suh, Yeon-Ok
    • Korean Journal of Adult Nursing
    • /
    • v.15 no.2
    • /
    • pp.305-315
    • /
    • 2003
  • Purpose: To describe the status of the laboratory facilities, equipment and expenses for practice in a four-year nursing schools and to analyze mandatory requirements for laboratory facilities and equipment. Method: A descriptive survey research design was used. The participants were 49 of the 4-year nursing schools across the nation. The data were collected by e-mail. The return rate for questionnaires was 63.3% (n=31). Result: In 2001 the total expenses for laboratory practice were 21,865,230 won and the average per student was 102,418 won. Types of laboratories included single and complex. The mean size for laboratories was $318.7m^2$ and mean size for laboratories for fundamental nursing was $161.1m^2$. The range for number of students in a laboratory class was 20-30 for eight universities (30.8%). Among required laboratory equipment, items that were deficient in 50% in the universities were mercury and aneroid sphygmomanometers for children, electronic sphygmomanometers, Bell type fetal stethoscopes, sheepskin, beds for children, for gynecology, and electronic hilo beds. Among the elective equipment, items that were deficient in 50% of the universities were $O^2$ tents, Blackmore tubes, retractors, hot-water supply, and incentive spirometers. The number of items that needed to add to the equipment were 10 for required equipment and 22 for elective equipment. Conclusion: A standardized mandatory list of equipment for laboratory facilities and expenses for practice in 4-year nursing schools needs to be developed.

  • PDF