• Title/Summary/Keyword: electrode sensor

Search Result 759, Processing Time 0.029 seconds

Implementation of Impedance Method to Estimate Blood Flow Variation with Cuff Pressure Change (커프 압력 조절에 따른 혈류량 변화 평가를 위한 임피던스법의 구현)

  • Jeong, Do-Un;Bae, Jin-Woo;Shon, Jung-Man;Yae, Su-Yung;Choi, Byeong-Cheol;Nam, Ki-Gon;Kim, Cheol-Han;Jeon, Gye-Rok
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.462-472
    • /
    • 2004
  • In this study, we measured the blood flow on arm by non-invasive method and implemented a system to measure variation of the blood flow by estimating bio-electrical impedance and arterial pressure according to cuff pressure. The implemented system measured impedance variation according to pressure variation applied by artificial cuff pressure on the measuring position. The system consisted of pressure measuring part and impedance measuring part using 4-electrode method. Pressure measuring part was composed of semiconductor pressure sensor and electronic circuit for signal processing of sensor output signal. In addition, impedance measuring part was composed of constant current source circuit and lock-in amplifier for detecting impedance signal. We conducted experiments of impedance measuring part using standard resistance for performance evaluation of the implemented system. In addition we experimented to estimate variation of the blood flow by measuring impedances of the experimental group. We estimated ratio of the blood flow resistance using mean arterial pressure and variation of the blood flow. As a result the ratio of the blood flow resistance and variation of blood flow were in an inverse relationship with each other and the correlation coefficient was -0.96776.

Resistive Humidity Sensor Using New N-Methacryloyl-N'-ethyl-N'-propyl Piperazinium Bromide Monomer and Their Properties (새로운 N-Methacryloyl-N'-ethyl-N'-propyl Piperazinium Bromide 단량체를 사용한 습도센서 및 그들의 특성 조사)

  • Lee, In-Ho;Park, Chan-Kyo;Gong, Myoung-Seon
    • Polymer(Korea)
    • /
    • v.33 no.4
    • /
    • pp.326-332
    • /
    • 2009
  • New humidity-sensitive monomer, N-methacryloyl-N'-ethyl-N'-propyl piperazinium bromide (MANEPPB) was prepared by the quaternization reaction of N-methacryloyl-N'-ethyl piperazine (MANEP) with 1-bromopropane. Polyelectrolytes derived from the copolymers composed of MANEPPB/MMN/AA=60/35/5, 70/25/5, 80/15/5, 90/5/5 and 95/0/5 were prepared for the humidity-sensitive membranes, which were fabricated on the gold electrode by dipping method and were crosslinked by reacting copolymers with aziridine crosslinker, trimethylolpropane tris(2-methyl-1-aziridinopropionate) (TTAP). When the resistance dependences on the relative humidity of the sensors were measured, it was found that the resistance varied three orders of magnitude between 20 and 90%RH, which was satisfied with the requirement for the common humidity sensor operating at ambient humidity. Their hysteresis, temperature dependence, frequency dependence, response and recovery time and water durability were measured and evaluated as a humidity-sensing membrane.

NO Gas Sensing of ACFs Treated by E-beam Irradiation in H2O2 Solution (과산화수소 용액에 담지 된 활성탄소섬유의 전자선 조사에 따른 일산화질소 가스 감응)

  • LEE, SANGMIN;PARK, MI-SEON;JUNG, MIN-JUNG;LEE, YOUNG-SEAK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.3
    • /
    • pp.298-305
    • /
    • 2016
  • In this study, we treated pitch-based activated carbon fibers (ACFs) in hydrogen peroxide using electron beam (E-beam) irradiation to improve nitrogen monoxide (NO) sensing ability as an electrode material of gas sensor. The specific surface area of ACFs treated by E-beam irradiation with 400 kGy increased from $885m^2/g$ (pristine) to $1160m^2/g$ without any changes in structural property and functional group. The increase in specific surface area of the E-beam irradiated ACFs enhanced NO gas sensing properties such as response time and sensitivity. When the ACFs irradiated with 400 kGy, response time was remarkably reduced from 360 s to 210 s and sensitivity was increased by 4.5%, compared to the pristine ACFs. These results demonstrate convincingly that surface modification of ACFs using E-beam in hydrogen peroxide solution can enhance textural properties of ACFs and NO gas sensing ability of gas sensor at room temperature.

Fabrication and Gas Sensing Properties of WO$_3$Thick Film Gas Sensor Dependent on Heat-Treatment Condition (소성 조건에 따른 WO$_3$계 후막센서소자의 제조 및 응답특성)

  • 정용근;엄우식;이희수;최성철
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.6 no.2
    • /
    • pp.63-68
    • /
    • 1999
  • We have fabricated $WO_3$ thick film gas sensor under various firing conditions in order to study gas sensing properties in terms of the variation of microstructure and non-stoichiometric structure of gas sensing layer. $WO_3$ paste mixed homogeneously with organic vehicle was coated by screen printing method on alumina substrate composed of Au electrode and $RuO_2$heater on each side. To change filing condition, sensing materials were fared at 600-$800^{\circ}C$ for 1 hour and refired at $700^{\circ}C$ for 1 hour in the mixtures of $_Ar/O2$gas. In the result of heat-treatment, $WO_3$ gas sensor fared at $700^{\circ}C$ showed best gas sensing properties of 210 gas sensitivity and 2 second response time and the best firing environment was 40-50% of $Ar/O_2$gas.

  • PDF

Detection of deoxynivalenol using a MOSFET-based biosensor (MOSFET형 바이오 센서를 이용한 디옥시 니발레놀의 검출)

  • Lim, Byoung-Hyun;Kwon, In-Su;Lee, Hee-Ho;Choi, Young-Sam;Shin, Jang-Kyoo;Choi, Sung-Wook;Chun, Hyang-Sook
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.306-312
    • /
    • 2010
  • We have detected deoxynivalenol(DON) using a metal-oxide-semiconductor field-effect-transistor(MOSFET)-based biosensor. The MOSFET-based biosensor is fabricated by a standard complementary metal-oxide-semiconductor(CMOS) process, and the biosensor's electrical characteristics were investigated. The output of the sensor was stabilized by employing a reference electrode that applies a fixed bias to the gate. Au which has a chemical affinity for thiol was used as the gate metal to immobilize a self-assembled monolayer(SAM) made of 16-mercaptohexadecanoic acid(MHDA). The SAM was used to immobilize anti-deoxynivalenol antibody. The carboxyl group of the SAM was bound to the anti- deoxynivalenol antibody. Anti-deoxynivalenol antibody and deoxynivalenol were bound by an antigen-antibody reaction. In this study, it is confirmed that the MOSFET-based biosensor can detect deoxynivalenol at concentrations as low as 0.1 ${\mu}g$/ml. The measurements were performed in phosphate buffered saline(PBS; pH 7.4) solution. To verify the interaction among the SAM, antibody, and antigen, surface plasmon resonance(SPR) measurements were performed.

Microstructure of TiO2 sensor electrode on nano block copolymertemplates using an ALD (나노 블록공중합체 템플레이트에 ALD로 제조된 센서용 TiO2 박막의 미세구조 연구)

  • Park, Jong-Sung;Han, Jeung-Jo;Song, Oh-Sung;Jeon, Seung-Min;Kim, Hyeong-Ki
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.239-244
    • /
    • 2009
  • We fabricated nano-templates by low temperature BCP(block copolymer) process at 180 $^{\circ}C$, then we deposited 10 nm-thick $TiO_2$ layers with ALD(atomic layer deposition) at low temperature of 150 $^{\circ}C$. Through FE-SEM analysis, we confirmed the successful formation of the groove-type(width of crest : 30 nm, width of trough : 18 nm) and the cylinder-type(diameter : 10 nm, distance between hole : 25 nm) templates. Moreover, after $TiO_2$-ALD processing, we confirmed the deposition of the uniform nano layers of $TiO_2$ on the nano-templates. Through AFM analysis, the pitches of the crest-through(in groove-type) and hole-hole(in cylinder-type) were the same before and after $TiO_2$-ALD processing. In addition, we indirectly determined the existence of the uniform $TiO_2$ layers on nano-templates as the surface roughness decreased drastically. We successfully fabricated nano-template at low temperature and confirmed that the three-dimensional nano-structure for sensor application could be achieved by $TiO_2$-ALD processing at extremely low temperature of 150 $^{\circ}C$.

Automotive Tire Pressure Sensors with Titanium Membrane (티타늄 박막을 이용한 자동차 타이어 압력센서)

  • Chae, Soo
    • Journal of Practical Engineering Education
    • /
    • v.6 no.2
    • /
    • pp.105-110
    • /
    • 2014
  • In this work, mechanical characteristics of titanium diaphragm have been studied as a potential robust substrate and a diaphragm material for automotive tire pressure sensor. Lamination process techniques combined with traditional micromachining processes have been adopted as suitable fabrication technologies. To illustrate these principles, capacitive pressure sensors based on titanium diaphragm have been designed, fabricated and characterized. The fabrication process for micromachined titanium devices keeps the membrane and substrate being at the environment of 20 MPa pressure and $200^{\circ}C$ for a half hour and then subsequently cooled to $24^{\circ}C$. Each sensor uses a stainless steel substrate, a laminated titanium film as a suspended movable plate and a fixed, surface micromachined back electrode of electroplated nickel. The finite element method is adopted to investigate residual stresses formed in the process. Besides, out-of-plane deflections are calculated under pressures on the diaphragm. The sensitivity of the fabricated device is $9.45ppm\;kPa^{-1}$ with a net capacitance change of 0.18 pF over a range 0-210 kPa.

Ni Nanoparticle Anchored on MWCNT as a Novel Electrochemical Sensor for Detection of Phenol

  • Wang, Yajing;Wang, Jiankang;Yao, Zhongping;Liu, Chenyu;Xie, Taiping;Deng, Qihuang;Jiang, Zhaohua
    • Nano
    • /
    • v.13 no.11
    • /
    • pp.1850134.1-1850134.10
    • /
    • 2018
  • Increasing active sites and enhancing electric conductivity are critical factors to improve sensing performance toward phenol. Herein, Ni nanoparticle was successfully anchored on acidified multiwalled carbon nanotube (a-MWCNT) surface by electroless plating technique to avoid Ni nanoparticle agglomeration and guarantee high conductivity. The crystal structure, phase composition and surface morphology were characterized by XRD, SEM and TEM measurement. The as-prepared Ni/a-MWCNT nanohybrid was immobilized onto glassy carbon electrode (GCE) surface for constructing phenol sensor. The phenol sensing performance indicated that Ni/a-MWCNT/GCE exhibited an amazing detection performance with rapid response time of 4 s, a relatively wide detection range from 0.01 mM to 0.48 mM, a detection limit of $7.07{\mu}M$ and high sensitivity of $566.2{\mu}A\;mM^{-1}\;cm^{-2}$. The superior selectivity, reproducibility, stability and applicability in real sample of Ni/a-MWCNT/GCE endowed it with potential application in discharged wastewater.

Development of Bib Pants Design and Pattern for Cycling Smart Wear (사이클링 스마트웨어 제작을 위한 빕 팬츠 디자인 및 패턴 개발)

  • Yunyoung, Kim;Byeongha, Ryu;Woojae, Lee;Kikwang, Lee;Rira, Kim
    • Journal of Fashion Business
    • /
    • v.26 no.5
    • /
    • pp.91-104
    • /
    • 2022
  • In this study, a cycling smart wear for measuring cycling posture and motion was developed using a three-dimensional motion analysis camera and an IMU inertial sensor. Results were compared according to parts to derive the optimal smart device attachment location, enabling correct posture measurement and cycle motion analysis to design a pattern. Conclusions were as follows: 1) 'S-T8' > 'S-T10' > 'S-L4' was the most significant area for each lumbar spine using a 3D motion analysis system with representative posture change (90°, 60°, 30°) to derive incisions and size specifications; 2) the part with the smallest relative angle change among significant section reference points during pattern design was applied as a reference point for attaching a cycling smart device to secure detachable safety of the device. Optimal locations for attaching the cycling device were the "S-L4" hip bone (Sacrum) and lumbar spine No. 4 (Lumbar 4th); 3) the most suitable sensor attachment location for monitoring knee induction-abduction was the anatomical location of the rectus femoris; 4) a cycling smart wear pattern was developed without incision in the part where the sensor and electrode passed. The wearing was confirmed with 3D CLO. This study aims to provide basic research on exercise analysis smart wear, to expand the smart cycling area that could only be realized with smart devices and smart watches attached to current cycles, and to provide an opportunity to commercialize it as cycling smart wear.

Characterization and surface engineering of two-dimensional atomic crystals

  • Yu, Yeong-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.63.1-63.1
    • /
    • 2015
  • The next generation electronics need to not only be smaller but also be more flexible. To meet such demands, van der Waals (vdW) heterostructures using two dimensional (2D) atomic crystals such as graphene, hexagonal boron nitride (h-BN) and transition metal dichalcogenides (TMDCs) have been attracted intensely. In particular, for high performance of vdW heterostructures device, ultraclean interface between stacked 2D atomic crystals should be guaranteed. In this talk, I will present fabrication and characterization of the vdW field effect transistors toward performance enhancement by employing TMDCs channel, h-BN insulating layer and graphene electrode. Furthermore, it will also be introduced the characterization and surface engineering of graphene for gas molecule sensor.

  • PDF