• 제목/요약/키워드: electrical energy storage devices

검색결과 130건 처리시간 0.028초

Area of Severity 평가를 이용한 에너지 저장장치의 위치 결정에 관한 연구 (A study on the Placement of Energy Storage System by using Area of Severity Assessment)

  • 이계병;박창현;배종일;이한상;조수환;장길수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.321-322
    • /
    • 2015
  • An area of severity (AOS) assessment is defined as a set of the fault positions that can result in the voltage sag bigger than certain level for sensitive buses simultaneously. Using the AOS assessment, the location of devices for compensating voltage sag can be determined as the site expected to less voltage sag at the sensitive bus. The energy storage system based on the control strategy emulating the traditional synchronous generator can contribute the fault current with fast response. Therefor are of venerability (AOV) can be reduced. The energy storage system installed by the AOS assessment has function which can experience relatively less voltage sag in addition to the conventional role of energy storage.

  • PDF

초전도 에너지 저장장치를 이용한 준동기공진의 개선에 관한 연구 (A Study on The Improvement of Subsynchronous Resonance Using by Superconducting Magnet Energy Storage.)

  • 이승원;원영진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.57-60
    • /
    • 1988
  • The investigation of subsynchronous resonance by utilities has resulted in proposed and applied method to mitigate or eliminate SSRdamage to turbine generators. Many papers presented various methods and devices that can be used as countermeasures for the SSR. This paper introduced the availability of Superconducting magnet energy storage as an countermeasure for the SSR in the capacitor compensated transmission line.

  • PDF

무선 센서 네트워크에서 플래시 장치를 활용한 에너지 효율적 저장 (Energy-Efficient Storage with Flash Device in Wireless Sensor Networks)

  • 박정규;김재호
    • 한국통신학회논문지
    • /
    • 제42권5호
    • /
    • pp.975-981
    • /
    • 2017
  • 본 논문에서는 WSN 환경에서 플래시 장치를 사용할 때 에너지를 효율적으로 사용하기 위한 방법을 제안한다. 전형적인 플래시 장치는 높은 대기 에너지로 인해 에너지가 제한된 WSN에서 비효율적인 에너지 소모 저장 매체라는 단점을 가지고 있다. 플래시 장치를 WSN 환경에서 에너지 효율적으로 사용하기 가장 쉬운 방법은 유휴 상태일 때 플래시 장치를 끄는 것이다. 이와 관련하여 우리는 비휘발성 및 바이트 주소 지정 기능을 제공하는 새로운 메모리 기술인 NVRAM (Nonvolatile RAM)을 활용하여 높은 대기 에너지 소모 그리고 시작 지연시간을 제거함으로써 간단하지만 이상적인 접근 방식을 현실적으로 제안한다. 특히 NVRAM을 메타 데이터 저장소의 확장으로 사용하여 FTL 메타 데이터 검색 프로세스를 제거하여 앞의 두 가지 장애 요소를 해결 하고자 한다. 실험을 통해 제안하는 방법이 기존 저장장치 비해 약 1.087% 에너지 만을 사용함을 알 수 있었다.

에너지저장시스템을 이용한 전력계통의 과도안정도 향상 (Transient Stability Enhancement of Power System by Using Energy Storage System)

  • 서규석
    • 한국산학기술학회논문지
    • /
    • 제18권12호
    • /
    • pp.26-31
    • /
    • 2017
  • 전력계통의 과도안정도를 향상시키기 위해 종래에는 무효전력 보상장치를 설치하는 방법을 주로 사용하였다. 전통적인 무효전력 보상장치 중 SVC(Static Var Compensator), 변압기의 탭 변환기는 값이 싸고 기계적 스위칭으로 동작하여 속도가 느리다는 단점이 있고, 전력전자기술을 바탕으로 하는 STATCOM(Static Synchronous Compensator)은 고속으로 동작할 수 있는 장점이 있어 최근에 각광을 받고 있지만 고가의 장치라는 단점이 있다. 또한, 무효전력 보상장치에 기반한 전통적인 방법은 무효전력만을 공급하여 과도안정도를 향상시키기에 대형 전동기의 트립에 의한 급격한 전압붕괴를 막을 수 없다. 반면에 에너지 저장시스템은 무효전력과 유효전력을 동시에 공급할 수 있다. 즉, 선로사고로 인하여 부하에 유효전력의 공급이 감소하는 것을 ESS을 통한 유효전력을 공급함과 동시에 적절한 무효전력의 공급을 통하여 과도안정도를 향상시킬 수 있다. 전력계통의 사고 시 유효전력의 빠른 공급은 과도안정도 향상에 매우 중요한 역할을 한다. 본 논문에서는 대형 전동기 부하와 같은 큰 동적부하를 가지는 전력계통에 대하여 에너지저장시스템을 사용한 과도안정도 향상방법을 제시한다. 또한, 유효전력과 무효전력을 보상하는 방법이 기존의 방법보다 더 효과적으로 과도안정도를 향상시킴을 확인하였다.

풍력터빈 발전기가 연계된 전력계통에서 에너지저장시스템이 과도안정도에 미치는 영향 (Transient Stability Enhancement of Power System by Using Energy Storage System)

  • 서규석
    • 한국산학기술학회논문지
    • /
    • 제20권6호
    • /
    • pp.592-597
    • /
    • 2019
  • 전력계통의 과도안정도를 향상시키기 위한 종래의 방법은 STATCOM(Static Synchronous Compensator), SVC(Static Var Compensator)와 같은 무효전력 보상장치를 이용하는 것이다. 하지만 무효전력 보상장치에 기반한 전통적인 방법은 대형 전동기의 트립에 의한 급격한 전압붕괴를 막을 수 없다. 반면에 에너지 저장시스템은 무효전력과 유효전력을 동시에 공급할 수 있다. 전력계통의 사고 시 유효전력의 빠른 공급은 과도안정도 향상에 매우 중요한 역할을 한다. 본 논문에서는 대형 전동기부하와 같은 큰 동적부하를 가지는 전력계통에 대하여 에너지저장시스템을 사용한 과도 안정도 향상방법을 제시한다. 또한 유효전력과 무효전력을 보상하는 방법이 기존의 방법보다 더 효과적으로 과도 안정도를 향상시킴을 확인하였다.

PWM 방식에 따른 계통연계 양방향 인버터의 손실양상 비교 및 분석 (Loss Analysis and Comparison of Grid-connected Bidirectional Inverter with Different Types of PWM Schemes)

  • 허성준;안효민;변종은;이병국
    • 전력전자학회논문지
    • /
    • 제22권6호
    • /
    • pp.547-550
    • /
    • 2017
  • This paper presents a loss analysis and compares three pulse width modulation (PWM) methods applied in a three-phase grid-connected bidirectional inverter for an energy storage system. The losses in switching devices and output low pass filters are theoretically analyzed by using PWM control techniques. Grid-connected bidirectional inverters are designed by using PWM techniques, and the designed inverters are simulated to verify the analysis results.

동력저장장치를 이용한 풍력$\cdot$태양광 복합발전시스템의 특성분석 (Analysis on the Operation Characteristic of the Combined Electric Power Generation System by Photovoltaic and Wind Energy with Power Storage Apparatu)

  • 임중열;이정일;정학수;차인수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.58-62
    • /
    • 2001
  • Photovoltaic and wind power generation have an advantage of unlimited and unpolluted amount of energy resource. In conventional wind generation systems, since the blade rotates at low speed when the velocity of wind decreases their operations are possible only under limited conditions. Therefore they are in trouble of self-generation without the help of auxiliary generation devices outside. The system driven by the wind force in this paper consists of a generator, an invertor, batteries and sets for power storage with a spring. In this paper, the operation characteristics of system were analyzed through experiments for a trial product.

  • PDF

배전계통 적용을 위한 전지전력저장시스템의 적정운전패턴에 관한 연구 (A Study on the Optimal Operation Pattern of Battery Energy Storage System for the Application to Distribution System)

  • 노대석;김재언;김호용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 추계학술대회 논문집 학회본부
    • /
    • pp.220-223
    • /
    • 1989
  • Over the last decade or so, there has been an increase in activity devoted to the development of renewable resources for generating electric energy. Many of these generators are small and can only be economically connected to the distribution system or to ths subtransmission system. Those which involve storage, a secondary source of energy, can provide a means to achieve more efficient use of existing generating plant. Such systems are known collectively as Dispersed Storage and Generation devices, or DSGs. So, in this paper various operation patterns for Battery Energy Storgy System which is considered as one of DSG, are examined.

  • PDF

전지관리장치(BMS)의 서지내성 성능향상 기법 (Surge Immunity Performance Enhancement Techniques on Battery Management System)

  • 김용성;임성정;서우현;정중일
    • 전기학회논문지
    • /
    • 제64권1호
    • /
    • pp.196-200
    • /
    • 2015
  • The switching noise in the power electronics of the power conversion equipment (Power Conditioning System) for large energy storage devices are generated. Since the burst-level transient noise from being generated in the power system at a higher power change process influences the control circuit of the low voltage driver circuit. Noise may cause the malfunction of the control device even if no dielectric breakdown leads to a control circuit. To overcome this, this paper proposes the installation of an additional nano-surge protection device on the power supply DC output circuit of the battery management unit.

플라이휠을 이용한 부하에의 순시전압강하 보상 방안 연구 (A Study of a Voltage Sag Compensation Scheme on Loads by Using Flywheel Energy Storage system)

  • 이한상;장길수;한상철;성태현;한영희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.321-322
    • /
    • 2006
  • Faults on power systems are inevitable phenomena. These faults can be classified by two categories, temporary and permanent faults. Without distinction of fault types, the faults would induce several changes on power system such as transmission line trip. Especially, the most common phenomena which loads experience by the power system fault is voltage sag. Voltage sags mean that the bus voltage maintains under 0.9 p.u. of rating for several cycles, and they give serious effects to operation of load devices. To ensure proper operation of the load, the flywheel systems, one of the energy storage system, are suggested in this paper. This paper demonstrates the efficiency of flywheel energy storage system against voltage sag by PSCAD/EMTDC simulation.

  • PDF