• Title/Summary/Keyword: electric field effects

Search Result 513, Processing Time 0.026 seconds

Effects of Electric and Magnetic Fields to Seed Germination and Its Early Growth (전계와 자계가 식물씨앗의 발아와 초기생장에 미치는 영향)

  • Moon, Jae-Duk;Kyon, Nam-Yul
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.6
    • /
    • pp.328-333
    • /
    • 2006
  • All the plants on earth live under an electric and magnetic field because the earth is a magnet and there is an electric field between the charged cloud and the ground. It has been reported that electromagnetic fields influence both the activation of ions and polarization of dipoles in living cells of seeds and plants, though the mechanism of these actions is still poorly understood. In this paper, the effects of the electric and magnetic fields and exposure times to the germination of several vegetable seeds and its early growth have been investigated experimentally to find out the feasibility of a plant factory for mass production of clean and unpolluted vegetables. The germination rate and the growth rate of some seeds under the fields exposed were analysed and compared with those of unexposed ones. It is found that the germination rate and its early growth rate of exposed seeds under the fields were accelerated about 1.1-1.4 and 1.7-2.2 times in maximum compared with those of unexposed ones. But, however, an inhibitory effect on germination and plant early growth were shown in the case of the higher electric and magnetic fields.

Transflective Fringe-Field Switching Liquid Crystal Device Driven by Vertical- and Fringe-field (수직전기장과 프린지 필드에 의해 구동되는 반투과형 FFS 액정소자)

  • Lim, Young-Jin;Park, Sang-Hyun;Choi, Min-Oh;Lee, Seung-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.279-280
    • /
    • 2005
  • We have designed a single gap transflective liquid crystal display (LCD) driven by a fringe electric field and vertical field. The conventional FFS mode does not have an electrode on top substrate, it shows not only slow response time due to weak electric field but also slow discharging problem when electrostatic field is generated after fabricating the cell. To solve these problems, transflective LCD with ITO coated upper substrate was suggested but the transmittance was reduced significantly due to effects from vertical field. Hence, in the present paper, new transflective LCD with ITO coating only in the reflective region was characterized.

  • PDF

Electromagnetic field and initial stress on a porothermoelastic medium

  • Abd-Elaziz, Elsayed M.
    • Structural Engineering and Mechanics
    • /
    • v.78 no.1
    • /
    • pp.1-13
    • /
    • 2021
  • In this study, the porothermoelastic problem with the effect of the magnetic field and initial stress was investigated. We applied normal mode analysis to solve the resulting non-dimensional coupled equations. Numerical results for the displacements, temperature distribution, pore pressure, stresses, induced electric field and induced magnetic field distributions are presented graphically and discussed. The medium deformed because of thermal shock and due to the application of the magnetic field, there result an induced magnetic and an induced electric field in the medium. Numerical analyses are given graphically on the square (2D) and cubic (3D) domains to illustrate the effects of the porosity parameter, magnetic field and initial stress parameter on the physical variables.

Effect of electric field on primary dark pulses in SPADs for advanced radiation detection applications

  • Lim, Kyung Taek;Kim, Hyoungtaek;Kim, Jinhwan;Cho, Gyuseong
    • Nuclear Engineering and Technology
    • /
    • v.53 no.2
    • /
    • pp.618-625
    • /
    • 2021
  • In this paper, the single-photon avalanche diodes (SPADs) featuring three different p-well implantation doses (∅p-well) of 5.0 × 1012, 4.0 × 1012, and 3.0 × 1012 atoms/cm2 under the identical device layouts were fabricated and characterized to evaluate the effects of field enhanced mechanisms on primary dark pulses due to the maximum electric field. From the I-V curves, the breakdown voltages were found as 23.2 V, 40.5 V, and 63.1 V with decreasing ∅p-well, respectively. By measuring DCRs as a function of temperature, we found a reduction of approximately 8% in the maximum electric field lead to a nearly 72% decrease in the DCR at Vex = 5 V and T = 25 ℃. Also, the activation energy increased from 0.43 eV to 0.50 eV, as decreasing the maximum electric field. Finally, we discuss the importance of electric field engineering in reducing the field-enhanced mechanisms contributing to the DCR in SPADs and the benefits on the SPADs related to different types of radiation detection applications.

Analysis on Harmonics Characteristics of ELF Magnetic Fields Generated by Electric Appliances (가전기기 발생 극저주파 자계 고조파 특성 해석)

  • Min Suk-Won;Song Ki-Hyun;Yang Kwang-Ho;Ju Mun-No
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.1
    • /
    • pp.31-37
    • /
    • 2005
  • With biological effects by ELF(Extremely Low Frequency) magnetic field generated from power system, the transient magnetic field from electric appliances is a major issue presently. In this paper, we measured magnetic field distributions around electric appliances in view of harmonics and analyzed them by the use of an equivalent magnetic dipole moment method. This method was applied to 19 types of appliances, and their equivalent magnetic dipole moments and harmonic components were determined. The results show that this method is applicable to many appliances and the higher frequency magnetic field may induce higher current inside living bodies.

The Electric Field Analysis of 2[MVA] Mold Transformer Considering the Void Effect in the Insulating Material (2[MVA] 몰드변압기 절연물내 기포 영향을 고려한 전계해석)

  • Kim, Chang-Eob;Jeon, Mun-Ho;Lee, Suk-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.4
    • /
    • pp.177-184
    • /
    • 2010
  • This paper presents the electric field analysis for 2[MVA] mold transformer using finite element method. The electric field was calculated for the voltage applied to the mold transformer without voids in the insulating material. Then, it was analysed the maximum electric field when the voids was in the insulating materials. And the starting voltage of partial discharge was predicted due to the voids. The effects of voids in epoxy resin on the electric field were investigated for different sizes, shapes, positions and arrangements of voids.

Morphology and Swelling Behaviors of PVA/Gelatin Blend Membranes Prepared Under High Electric Field (고전장하에서 제조된 PVA/Gelatin 블렌드막의 구조와 팽윤거동)

  • Huh, Yang-Il;Yun, Hyung-Ku
    • Polymer(Korea)
    • /
    • v.30 no.6
    • /
    • pp.563-567
    • /
    • 2006
  • Poly(vinyl alcohol) (PVA) and gelatin (GEL) blend membranes were prepared by solution casting method under a high electric field. SEM observation of the membrane showed that gelatin rich domains were elongated and oriented to the direction of the applied electric field in PVA matrix. This can be attributed to the electrostatic emulsifying effects due to a reduction in interfacial tension. In addition, it was observed through WAXD and swelling measurements that the degree of crystallinity of membranes increased with applied electric field strength. This may be interpreted to be caused by the orientation effect of GEL domains in the blend membrane, and the self-annealing effect due to some heat generated from high electric field during casting.

Dependence by the electric field effect in the photoinduced anisotropy(PA) of the chalcogenide thin film. (칼코게나이드 박막에서의 광유기 이방성(PA)의 전계효과 의존성)

  • Jang, Sun-Joo;Park, Jong-Hha;Yeo, Choel-Ho;Park, Jung-Il;Lee, Young-Jong;Chung, Hong-Bay
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1500-1502
    • /
    • 2000
  • In this study, we have investigated the photoinduced anisotropy (PA) phenomena by the assisted. electric field effect on $As_{40}Ge_{10}Se_{15}S_{35}$ thin films. Investigation of photoinduced anisotropy on the assisted electric field effect was carried out using a He-Ne laser beams (inducing and probing beams) illuminating the same area of the thin film. To investigate the effect of electric field, various bias voltages applied. The result is shown the photoinduced anisotropy dependence on electric field. Also. we obtained the property of photoinduced anisotropy in the electric field effects by various voltages.

  • PDF

Experimental Study on the Effects of AC Electric Fields on Flame Spreading over Polyethylene-insulated Electric-Wire (폴리에틸렌으로 피복된 전선화염의 전파에 교류전기장이 미치는 영향에 관한 실험적 연구)

  • Jin, Young-Kyu;Kim, Min-Kuk;Park, Jeong;Chung, Suk-Ho;Kim, Tae-Hyung;Park, Jong-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.11
    • /
    • pp.1015-1025
    • /
    • 2010
  • In this present study, we experimentally investigated the effects of electric fields on the characteristics of flames spreading over electric-wires with AC fields. The dependence of the rate at which a flame spreads over polyethylene-insulated wires on the frequency and amplitude of the applied AC electric field was examined. The spreading of the flame can be categorized into linear spreading and non-linearly accelerated spreading of flame. This categorization is based on the axial distribution of the field strength of the applied electric field. The rate at which the flame spreads is highly dependent on the inclined direction of the wire fire. It could be possible to explain the spreading of the flame on the basis of thermal balance.

Pulsed Electric Field Effects to Reduce the Level of Campylobacter spp. in Scalder and Chiller Water during Broiler Chicken Processing

  • Shin, Dae-Keun;Martin, Bradely C.;Sanchez-Plata, Marcos X.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.24 no.9
    • /
    • pp.1314-1317
    • /
    • 2011
  • To evaluate the effects of pulsed electric field (PEF) application on scalder and chiller water on Campylobacter contamination, four different treatments under three different water conditions including hard scalder water ($55^{\circ}C$), soft scalder water ($45^{\circ}C$) and chiller water, were applied as follows: i) a control treatment with no salt and no electric treatment, ii) a PEF only treatment, iii) a PEF treatment with 0.5% salt water, and iv) a PEF treatment with 1% salt water treatment. The use of PEF in hard scalding water showed an effect of reducing Campylobacter when compared to the control during the 200 s timeframe. With the addition of salt, the intervention caused at least 5.81 log CFU/ml reduction of Campylobacter counts after 200 s of PEF exposure. Similar effects were observed under soft scalding conditions. Campylobacter reductions were evident under chilling conditions with up to 2.00 log for PEF only, 5.77 log for PEF+0.5% salt and 2.69 log for PEF+1% salt treatment in water. Therefore, the current PEF setting for the scalder and chiller water can be successfully used to reduce pathogenic loads of Campylobacter on broiler chicken carcasses, and further research may be necessary to apply it in the poultry processing industry.