• Title/Summary/Keyword: ejection

Search Result 738, Processing Time 0.029 seconds

New Drug Delivery System Based on a Laser-Induced Shockwave (레이저 유도 충격파를 이용한 첨단 약물전달시스템 개발)

  • Han, Tae-Hee;Lee, Hyun-Hee;Gojani, Ardian B.;Yoh, Jai-Ick
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.1
    • /
    • pp.67-71
    • /
    • 2010
  • Impingement of a high power laser pulse (above 1 GW/$cm^2$) on a metal foil causes its ablation, which is characterized by a rapid expulsion of matter and the initiation of a strong shock wave inside the solid metal. The shock propagates through the foil and reverberates on the rear side, causing its deformation and microparticle ejection, which were deposited on the foil prior to ablation. Based on this principle, we are developing a new drug delivery system - Biolistic gun. Current study is focused on the controllability, stability, efficiency of the system, and characterization of the penetration shapes in various conditions. We have tested the system by applying direct and confined ablation. Several different media combinations were used for confinement-BK7 glass, water, BK7 glass with water, and succulent jelly(ultrasono jelly, RHAPAPHRM). Biological tissue was replicated by a 3% gelatin solution. Present data shows that the confinement results in enhancement of penetration shape reached by 5 um cobalt microparticles. Based on the analysis of the experimental results we observe that the penetration shape of microparticles can be controlled by adjusting the thickness of confinement media.

Effect of Medetomidine and Combination of Medetomidine/tiletamine/zolazepam and Medetomidine/tiletamine/zolazepam/tramadol on Echocardiographic Cardiac Contractility in Dogs (개에서 Medetomidine, Medetomidine/tiletamine/zolazepam 합제, Medetomidine/tiletamine/zolazepam/tramadol 합제가 심장초음파 상 심장 수축력에 미치는 영향)

  • Suh, Sang-IL;Kim, Tae-Jun;Lee, Eun-Chan;Hyun, Changbaig
    • Journal of Veterinary Clinics
    • /
    • v.32 no.5
    • /
    • pp.422-425
    • /
    • 2015
  • This study evaluated the myocardial performance on echocardiography after the sedation/anesthesia of medetomidine (D), the combination of medetomidine and tiletamine/zolazepam (DZ), and the combination of medetomidine, tiletamine/zolazepam and tramadol (DZT) in Beagle dogs. Ten healthy adult Beagle dogs (weighing $8.6{\pm}1.0kg$) were enrolled in this study. Heart rate (HR), fractional shortening (%FS), left ventricular ejection fraction (%LVEF), stroke volume (SV), cardiac output (CO), left ventricular internal diameter in systole (LVIDs) and left ventricular internal diameter in diastole (LVIDd) using M-mode echocardiography were measured prior to anesthesia, then every 10 min for 60 min. The HR, %FS, %LVEF, SV and CO were significantly decreased during sedation/anesthesia with D, DZ and DZT combination of anesthesia. Although those anesthetic protocols provided acceptable quality of sedation/anesthesia, levels of cardiovascular suppression were substantial and persistent and thus the continuous monitoring on vital signs should be accompanied in any situation. Close attention is required for dogs with pre-existing heart diseases, when those anesthetic protocols were applied.

Regression of Left Ventricular Hypertrophy after AVR in Aortic Valvular Stenosis (대동맥판막협착증 환자에서 판막치환 후 좌심실심근비후의 변화)

  • 이재원;최강주;송명근
    • Journal of Chest Surgery
    • /
    • v.31 no.6
    • /
    • pp.586-590
    • /
    • 1998
  • Background: The regression of the left ventricular hypertrophy after prosthetic valve replacement in patients with aortic valvular stenosis is an important factor to determine the appropriateness of the replaced prosthetic valvular size. Methods: To assess the regression of myocardial hypertrophy, a retrospective analysis of Doppler echocardiographic and electrocardiographic data was undertaken before, soon after(7.5$\pm$2.1 day), and late after(10.7$\pm$1.8 months) surgery in 36 patients(22 males, 14 female, mean age 54$\pm$12.1 years, mean BSA 1.61$\pm$0.15m2) with predominant aortic valvular stenosis. The patients underwent St. Jude Medical aortic valve replacement. By the size of the valves used, the patients were divided into three groups(19, 21 and 23+). Results: The mean body surface area(1.48$\pm$0.13) in the patients with the 19 mm valve was smaller than that in the other groups(1.63$\pm$0.12)(p<0.05). No significant changes of ejection fraction were detected in all groups over time. Left ventricular muscle mass index(gm/m2) was reduced significantly in the 21 and 23+ groups over time(p<0.05), but there were no significant changes in the 19 mm valve group. The electric voltage height on EKG at the period of late after surgery was reduced significantly in all groups(p<0.05). Conclusion: Despite clinical improvement, the LVH was not reduced significantly in 19 mm valve group. Thus we suggest that more attention and additional procedures such as annular enlargement should be taken in patients who will undergo the replacement of 19 mm prosthetic valve.

  • PDF

Early Result of Coronary Artery Bypass Grafting Using the Radial Artery (요골동맥를 이용한 관상동맥우회술의 조기성적)

  • 박진홍;지현근;신윤철;김응중
    • Journal of Chest Surgery
    • /
    • v.36 no.10
    • /
    • pp.734-740
    • /
    • 2003
  • Increasing interest in the use of arterial conduits is based on the better patency of left internal thoracic artery (LITA) than that of saphenous vein (SV) graft and radial artery (RA) is emerging as one of them. We compared the early result of coronary artery bypass grafting (CABG) using UTA and RA (RA group) with CABG using UTA and SV only (SV group). Material and Method: We compared the early operative results of 45 cases in RA group with 45 cases in SV group selected from 165 cases who had CABG between January 2000 and December 2002. The two groups had similar profiles of age, sex, NYHA functional class, left ventricular ejection fraction and coronary angiographic anatomy. We analysed each group on the preoperative risk factors and operative results. Result: There were no statically signigicant difference between groups in operative mortality and each morbidities (stroke, IABP insertion, perioperative MI), respectively. However, the overall incidence of mortality and morbidities was lower in RA group compared to SV group (p < 0.05). RA group (2.93$\pm$0.62 days) had shorter duration of ICU stay than SV group (3.55$\pm$0.95 days) (p<0.001). The patency on postoperative coronary angiography at 7∼14 days after operation in RA group patients were 100% of LITA and RA and 94.9% of SV. Conclusion: We had better early operative results in RA group compared with SV group.

Early Result of Coronary Artery Bypass Surgery (관상동맥 우회술의 조기성적)

  • Park, Jae-Hyeong;Lee, Won-Yong;Kim, Eung-Jung;Hong, Gi-U
    • Journal of Chest Surgery
    • /
    • v.30 no.2
    • /
    • pp.158-163
    • /
    • 1997
  • From July 1994 to August 1995, 32 patients underwent coronary artery bypass surgery. There were 14 men and 18 women. The mean age was 59 years (range from 37 to 81 years). Preoperatively 26 patients had unstable angina pectoris and 6 patients had stable angina pectoris. Nine patients had previous myocardial infarction hi tory. Five patients had preoperative left ventricular ejection fraction of 40% or less, The involved risk factors were as follows ; smoking 19 cases, hypertension 16 cases, hypercholesterolemia 14 cases, diabetes mellitus 6 cases, and obesity 3 cases.21 patients had three-vessel disease, 7 patients had two-vessel disease, 2 patients had one-vessel disease and 2 patients had left main coronary artery disease. We performed 103 distal bypasses out of 32 cases, and the mean number of grafts per patients is 3.22. We used arterial grafts (left internal mammary artery,)1, radial artery; 2) in 32% of total grafts. Postoperative complications were low cardiac output, perioperative myocardial infarction, respiratory failure and atrial fibrillation, etc. Early mortality was 6.25% (2/32). The causes of deaths were low cardiac output (1), and perioperative myocardial infarction(1).

  • PDF

Clinical Experience of Medtronic-Hall Valve (Medtronic-Hall 기계판막의 임상경험)

  • 김종원;정성운
    • Journal of Chest Surgery
    • /
    • v.31 no.11
    • /
    • pp.1031-1036
    • /
    • 1998
  • Background: Medtronic-Hall mechanical valve is a world widely using prosthesis. But, in Korea, the clinical result from Medtronic-Hall valve replacement is not frequenthy available. Materials and methods: From March 1986 to May 1990, 50 patients underwent valve replacement surgery with Medtronic-Hall valve at Pusan National University Hospital. Seventeen were male and thirty three were female and ra nging in age from 16 to 70 years of age(mean=35 years). Results: The causes of valvular lesion were rheumatic in 43 patients, bicuspid aortic valve in 3 patients, degenerative lesion in three patients and bacterial endocarditis in one patient. The operative procedures were mitral valve replacement(MVR) in 38, aortic valve replacement(AVR) in 5 and double valve replacement(DVR) in 7. The most commonly used valve size was 21mm in AVR, 29mm in MVR. Concomitant surgical procedures were performed in 15 patients; left atrial thrombectomy in 9, left atrial auricle obliteration in 6 and tricuspid annuloplasty in 5(Kay: 2, DeVega: 3). New York Heart Association functional class was mostly Class Ⅲ or Ⅳ(91.5%) preoperatively and ClassⅠor Ⅱ(87.2%) after operation. The findings of postoperative echocardiogram of LAD, LVESD, LVEDD were reduced compared with preoperative period and ejection fraction was increased compared with preoperative period. Postoperative complications were massive bleeding in three, low cardiac output syndrome in two, thromboembolism in one and fulminant hepatitis in one patient. There were three hospital deaths and their causes were low cardiac output syndrome in two and rupture of left ventricle in one patient. The 5 year survival rate was 93.65±0.71% and 10 year actuarial survival rate was 88.27±6.42%. Conclusions: Medtronic-Hall mechanical valve has low valve related complication rate. It's durability and hemodynamic performance is comparable to other mechanical valves.

  • PDF

Effects of Gas Background Temperature Difference(Emissivity) on OGI(Optical Gas Image) Clarity (가스의 배경 온도 차이(방사율)가 OGI(Optical Gas Image)의 선명도에 미치는 영향)

  • Park, Su-Ri;Han, Sang-Wook;Kim, Byung-Jick;Hong, Cheol-Jae
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.5
    • /
    • pp.1-8
    • /
    • 2017
  • Currently gas safety management in the industrial field has been done by LDAR as contact method or methane leak detector as non-contact method. But LDAR method requires a lot of man-power and methane leak detector have the limitation of methane only. Therefore the Research on the OGI(optical gas image) has big attention by industry. This research was undertaken to see the effect of background temperature difference of gas cloud on the clarity of OGI. The background temperature control panel was constructed to cool down the background temperature. OGI was taken at the various methane gas ejection rate and the designed temperature difference. The experimental results showed that the OGI(when the temperature difference is $-6^{\circ}C$) is more clear thane the OGI(when the temperature difference is zero). To quantify the clarity difference, MATLAB's RGB analysis method was employed. The RGB value of the OGI at ${\Delta}T-6^{\circ}C$ was 20% lower than the OGI at ${\Delta}T0^{\circ}C$. The clarity difference by T difference can be explained by the total radiation law. When the background temperature of the gas is lower than the air temperature, the radiation energy coming into the OGI lens is increasing. As the energy is increasing, the OGI image becomes clear.

Secondary Flow Patterns of Liquid Ejector with Computational Analysis (액체상 이젝터의 2차측 액체 송출량 특성 전산해석)

  • Kwon, Kwisung;Yun, Jinwon;Sohn, Inseok;Seo, Yongkyo;Yu, Sangseok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.2
    • /
    • pp.183-190
    • /
    • 2015
  • An ejector is a type of non-powered pump that is used to supply a secondary flow via the ejection of a primary flow. It is utilized in many industrial fields, and is used for fueling the vehicle because of less failures and simple structure. Since most of ejectors in industry are gas-to-gas and liquid to gas ejector, many research activities have been reported in optimization of gas ejector. On the other hand, the liquid ejector is also applied in many industry but few research has been reported. The liquid ejector occurs cavitation, and it causes damage of parts. Cavitation has bees observed at the nozzle throat at the specified pressure. In this study, a two-dimensional axisymmetric simulation of a liquid-liquid ejector was carried out using five different parameters. The angle of the nozzle plays an important role in the cavitation of a liquid ejector, and the performance characteristics of the flow ratio showed that an angle of $35^{\circ}$ was the most advantageous. The simulation results showed that the performance of the liquid ejector and the cavitation effect have to be considered simultaneously.

Comparison of Gallbladder Emptying Induced by a Fatty Meal and an Infusion of Cholecystokinin (정상인에서 지방식 투여와 CCK 연속주입에 의한 담낭 수축의 비교 연구)

  • Ryu, Jin-Sook;Shin, Sang-Ki;Moon, Dae-Hyuk;Lee, Myung-Hae;Lee, Sung-Koo;Kim, Myung-Hwan;Min, Young-Il
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.1
    • /
    • pp.86-94
    • /
    • 1992
  • Quantitative analysis of gallbladder emptying is important in diagnosis of motility disorder of gallbladder and in studies of biliary physiology. However, the normal range of gallbladder ejection fraction (GBEF) has not been determined yet and the best method for stimulating the gallbladder to contract has not been elucidated adequately. The purpose of this study was to compare the gallbladder emptying effect of the fatty meal ingestion with that of the continuous infusion of cholecystokinin (CCK) and to establish the normal GBSF values of normal subjects. Quantitative hepatobiliary scan with $^{99m}Tc-DISIDA$ after a fatty meal was performed for 22 normal healthy volunteers. Among them, 10 subjects repeated the test with a fatty meal. Again, for 7 subjects quantitative heaptobiliary scan with an infusion of CCK (sincalide) at a rate of 20 ng/kg/hr for 45 minutes was performed repeatedly. The results were as follows. 1) With a fatty meal, the mean GBEF was $89.6{\pm}8.2%$ in 22 normal subjects, and there was no difference between subjects. 2) With a continuous infusion of CCK, the mean GBEF was $62.4{\pm}16.6%$ in 7 normal subjects, and there was a significant difference between subjects(p<0.05). 3) The reproducibility of GBEF by a fatty meal was significantly higher than by an infusion of CCK (p < 0.05). 4) The mean GBEF by a fatty meal was significantly higher than that by an infusion of CCK (p < 0.05). We concluded that a fatty meal is superior to a continuous infusion of CCK for inducing gall-bladder contraction because that induces more complete emptying and the response is more reproducible and constant.

  • PDF

Role of Oxytocin in Male Reproduction (수컷 생식에 옥시토신의 역할)

  • Lee, Sung-Ho
    • Development and Reproduction
    • /
    • v.13 no.2
    • /
    • pp.79-87
    • /
    • 2009
  • Due to its well-known function in parturition and milk ejection, oxytocin (OT) has been considered as a 'female neurohypophyseal hormone'. Recent studies, however, clearly indicate that OT has some local roles in male reproduction via both central and peripheral routes. In experimental rodents, OT is released within distinct brain regions in response to social stimuli, and the brain OT receptor (OTR) mediated actions were strongly involved in the regulation of a variety of male behaviors such as mating-associated behaviors. In particular, OT and/or OTR knockout mice provide important clues about the molecular regulatory mechanism of the socio-sexual behaviors. Several lines of evidence also show that OT is synthesized within rodents testis, epididymis and prostate, and the presence of OTRs in these organs. In rodent testes, OT might have a role in the modulation of steroidogenesis via stimulation of the conversion of testosterone (T) to dihydrotestosterone (DHT) by 5alpha-reductase. Similar effects of OT on this androgen conversion were observed in epididymis and prostate suggesting the OT's modulatory role, such as contractility induction, in these androgen-dependent organs. In this context, further investigations on the OT's role in male CNS and reproductive organs are likely to provide better understanding on the complex socio-sexual behaviors and a platform for development of therapeutics to treat some psychological and/or andrological problems.

  • PDF