• 제목/요약/키워드: eccentricity

검색결과 901건 처리시간 0.024초

A Study on the fire-resistance of concrete-filled steel square tube columns without fire protection under constant central axial loads

  • Park, Su-Hee;Choi, Sung-Mo;Chung, Kyung-Soo
    • Steel and Composite Structures
    • /
    • 제8권6호
    • /
    • pp.491-510
    • /
    • 2008
  • This paper presents a plan and guidelines that were drawn for Korean based research carried out on the fire-resistance of CFT columns. This research was carried out by reviewing the Korean regulations related to the fire-resistance of CFT columns and examining studies which had been made in Korea as well as overseas. The first phase of the study plan was to compare the fire-resistance of square CFT columns without fire protection (obtained through fire-resistance tests and numerical analyses) with estimated values (obtained through fire-resistance design formulas proposed in Korea and overseas). This comparison provided conclusions as outlined below. Fire-resistance tests conducted in this study proved that, when the actual design load is taken into consideration, square CFT columns without fire protection are able to resist a fire for more than one hour. A comparison was made of test and analysis results with the fire-resistance time based on the AIJ code, the AISC design formula and the estimation formula suggested for Korea. The results of this comparison showed that the test and analysis results for specimens SAH1, SAH2-1, SAH2-2 and SAH3 were almost identical with the AIJ code, the AISC design formula and estimation formula. For specimens SAH4 and SAH5, the estimation formula was more conservative than the AIJ code and the AISC design formula. It was necessary to identify the factors that have an influence on the fire-resistance of CFT columns without fire protection and to draw fire-resistance design formulas for these columns. To achieve this, it is proposed that numerical analyses and tests be conducted in order to evaluate the fire-resistance of circular CFT columns, the influence of eccentricity existing as an additional factor and the influence of the slenderness ratio of the columns. It is also suggested that the overall behavior of CFT structures without fire protection within a fire be evaluated through analysis simulation.

이차곡선의 작도 활동에서 나타난 유추적 사고 (Analogical Reasoning in Construction of Quadratic Curves)

  • 허남구
    • 대한수학교육학회지:수학교육학연구
    • /
    • 제27권1호
    • /
    • pp.51-67
    • /
    • 2017
  • 유추는 학생들의 문제 해결력, 귀납적 추론, 수학적 발견술, 창의성 신장에 도움을 줄 수 있는 수학 교육적으로 유용한 사고 방법이다. 학생들은 서로 다른 수학적 대상에 대해 유사성을 바탕으로 연결함으로써 두 대상 사이의 관계를 인식할 수 있다. 본 연구에서는 예비수학교사들이 이심률의 정의에 따른 이차곡선의 작도 과정에서 드러난 사고의 특징을 유추의 관점에서 분석하였다. 그 결과, 바탕 문제에 관한 수학적 지식의 부재와 바탕 문제의 수학적 지식에 대응하는 목표 문제의 수학적 지식의 부재는 목표 문제의 해결에 도움되지 못하였다. 바탕 문제의 다양한 해결 방법은 목표 문제의 해결에 도움을 주었으며, 일부는 작도 문제의 해결에 있어 적절한 바탕 문제를 설정하고 대수적 방법을 통해 문제를 해결하였다. 마지막으로 잠재적 유사성에 근거한 유추는 새로운 풀이 방법을 발견하는데 도움을 주었다.

범프로 지지되는 다엽 포일을 갖는 가스 포일 베어링의 성능 해석 (Performance Predictions of Gas Foil Bearing with Leaf Foils Supported on Bumps)

  • 김태호;문형욱
    • Tribology and Lubricants
    • /
    • 제34권3호
    • /
    • pp.75-83
    • /
    • 2018
  • Microturbomachinery (< 250 kW) using gas foil bearings can function without oil lubricants, simplify rotor-bearing systems, and demonstrate excellent rotordynamic stability at high speeds. State-of-the-art technologies generally use bump foil bearings or leaf foil bearings due to the specific advantages of each of the two types. Although these two types of bearings have been studied extensively, there are very few studies on leaf-bump foil bearings, which are a combination of the two aforementioned bearings. In this work, we illustrate a simple mathematical model of the leaf-bump foil bearing with leaf foils supported on bumps, and predict its static and dynamic performances. The analysis uses the simple elastic model for bumps that was previously developed and verified using experimental data, adds a leaf foil model, and solves the Reynolds equation for isothermal, isoviscous, and ideal gas fluid flow. The model predicts that the drag torques of the leaf-bump foil bearings are not affected significantly by static load and bearing clearance. Due to the preload effect of the leaf foils, rotor spinning, even under null static load, generates significant hydrodynamic pressure with its peak near the trailing edge of each leaf foil. A parametric study reveals that, while the journal eccentricity and minimum film thickness decrease, the drag torque, direct stiffness, and direct damping increase with increasing bump stiffness. The journal attitude angle and cross-coupled stiffness remain nearly constant with increasing bump stiffness. Interestingly, they are significantly smaller compared to the corresponding values obtained for bump foil bearings, thus, implying favorable rotor stability performance.

외부 긴장된 H형 보의 휨거동 특성 (Flexural Behavior of External Prestressed H-Beam)

  • 양동석;임상훈;박선규
    • 한국강구조학회 논문집
    • /
    • 제14권1호
    • /
    • pp.79-85
    • /
    • 2002
  • 본 연구에서는 기존에 사용된 H-Beam 교량을 편향부와 외부 긴장력을 도입하여 보강효과에 의하여 지간을 증가시킬 수 있고 단면을 축소할 수 있다는 근거를 제시하였고, 유연도법을 이용하여 편향부의 효과에 의한 추가 긴장량을 산정하였다. 또한, 실험변수(긴장량, Tendon의 개수, 편향부의 유 무)에 의해서 표준실험체(기존 H-Beam)와 외부 긴장된 H-Beam 등 5개의 실험체를 제작하여 휨 실험을 실시하여 외부 긴장된 H-Beam의 역학적 거동을 연구하였다. 특히, 보강효과 및 편향부의 효과를 실험적으로 검증하였다.

정지궤도위성 탑재용 실시간 궤도요소 생성기 (On-board Realtime Orbit Parameter Generator for Geostationary Satellite)

  • 박봉규;양군호
    • 항공우주기술
    • /
    • 제8권2호
    • /
    • pp.61-67
    • /
    • 2009
  • 본 논문은 정지궤도위성에 탑재 가능한 저 계산량의 궤도데이터 생성 알고리즘을 제안하고 있다. 제안하는 알고리즘의 기본적인 개념은 지상에서 생성된 기준궤도에 대한 변위 정보를 48시간에 대하여 30분 간격으로 생성한 다음, 위성에 업로드 한다. 위성에서는 업로드된 변위정보를 테이블 형태로 저장하고, 원하는 시간에 근접한 세 개의 데이터 셋을 취한 다음 이차함수 보간법 적용하여 원하는 시간에 대한 변위정보를 계산한다. 생성된 변위 정보는 다시 기준궤도에 더해져 최종적인 궤도성분을 복구하도록 한다. 여기서 기준궤도는 이심율과 궤도 경사각이 0인 이상적인 정지궤도를 의미한다. 본 알고리즘을 이용할 경우 1Hz이상의 속도로 궤도정보를 생성하여 요구하는 탑재체에 공급 할 수 있는 장점이 있다. 본 알고리즘은 48시간에 대한 궤도 변위 정보를 저장하기 위하여 3킬로바이트 이내의 추가적인 메모리를 요구한다. 이러한 수치는 정지궤도위성에서 충분히 지원 가능한 수치로 판단된다.

  • PDF

비계지지브라켓 유형별 구조기준 설정에 관한 실험적 연구 (Establishing the Structural Criteria to install Scaffolding-Use Brackets)

  • 손기상;갈원모
    • 한국안전학회지
    • /
    • 제10권4호
    • /
    • pp.87-96
    • /
    • 1995
  • It is only three(3) years since we applied brackets for scaffolding in the construction area. Unfortunately, there is no structural criteria on how to install those in the site so far, despite the fact that those brackets have been applied into the site by the firms already. It is shown that resistant capacity of each bracket type has been investigated, analyzed from this experimental study. Accident-concerning data on construction site analyzed by the Ministry of Labor, show temporary structure involves 18.6% of the total industrial accident, which the accidents from scafold-supporting brackets have rate of 42.5% of the ones occurred from the temporary structures. There are two main aspects to be observed : one is how much resistant capacity the brackets have themselves, the other is how exactly to install those without eccentricity. But practically, nobody does check of this bolt-installing conditions in the site and no check of tightening level of nut because there is no available tool to check torque amount for this kind of nut. We just have to rely on scaffolders experience of this tightening. This experiment involves just this variable of tightness at site. Eventually this insufficient tightness causes to collapse those scaffolding structures. The bracket might have less the one than its original capacity due to this insufficient tightness. Three(3) times of PIVOT tests show that fractured condition of two(2) row brackets has occurred mostly at lower bolt due to shear force. Therefore, tightness of bracket-installing bolt, tensile strength of the bolt, shear strength of the bolt, loading condition with equal two point or inequal two point loads, are mainly investigated as variables in this study.

  • PDF

골프장 연못의 생태적 관리를 위한 환경특성 분석 (Analyses of the Environmental Characteristics of Ponds in Golf Courses for Ecological Management)

  • 안득수;김창환
    • 한국조경학회지
    • /
    • 제33권6호
    • /
    • pp.51-77
    • /
    • 2006
  • Pond management is a critical part of overall golf course management, both during growth and maintenance modes of turf care. This study investigated 48 ponds in nine 18- or 27-hole golf courses to analyze the environmental characteristics of ponds. The research process had three phases: (1) inventory and analysis of grading plans and drainage plans, (2) field verification and interviews with greenskeepers, and (3) analyses of water quality and statistics. All data were collected from May to August in 2004. The results of this study can be summarized as follows: 1. It is desirable to site a golf course in a small watershed with high watershed eccentricity to control storm water runoff efficiently and to minimize soil erosion during construction. 2. The siting and size of a pond should be determined through a land-use analysis of the watershed for the purpose of ecological management. The bigger the forest-to-golf course ratio, the better the water quality will be. 3. The size and capacity of each individual ponds varied and there were many somewhat longish rather than round ponds. 4. There were many differences among golf courses in naturalness of the ponds, and the correlation between naturalness and area of aquatic plants was very high. 5. Analyses of pond water quality indicated that the degrees of Dissolved Oxygen, Chemical Oxygen Demanded and Suspended Solids were relatively low values but Total Phosphorus and Total Nitrogen were too high. Therefore a systematic approach is needed to solve e problem. Pesticide residues were not detected in all ponds. 6. Water depth and area of hydrophyte should be considered when designing an ecological pond. 7. All ponds used storm water as a main source of water supply and added underground water. Aquatic plants and physical methods such as water aeration and spray fountains were the main choices for maintaining a healthy aquatic environment.

프리스트레스트 콘크리트 합성(合性)보의 직접설계(直接設計) (Direct Design of Composite Prestressed Concrete Beams)

  • 김수만
    • 대한토목학회논문집
    • /
    • 제10권3호
    • /
    • pp.49-56
    • /
    • 1990
  • 오늘날 프리스트레스트 콘크리트(PC) 합성보의 설계는 단면을 가정한 다음 프리스트레스 크가와 편심거리(偏心距離)를 구하는 일로 이루어 진다. 이러한 설계방법(設計方法)으로는 PC보와 철근큰크리트 슬래브로 형성(形成)된 합성단면(合成斷面)의 특성(特性)이 설계(設計)에 반영되지 못하므로 이를 반영(反映)하기 위해서는 반복설계(反復設計)를 거쳐야 한다. 이와 같은 반복설계는 시간과 인력을 요(要)하므로 비(非) 경제적(經濟的)인 설계방법이 된다. 따라서 반복설계를 피하고 직접(直接) 설계(設計)할 수 있는 개선(改善)된 설계방법의 개발(開發)이 요망(要望)된다. 이 연구(硏究)에서는 비합성단면(非合成斷面)을 직접(直接) 설계(設計)할 수 있듯이 합성단면(合成斷面)도 직접 설계할 수 있도록 개선된 설계 방법을 제안(提案)하였다. 제안(提案)된 설계방법(設計方法)을 쉽게 활용(活用)할 수 있도록 설계예(設計例)를 제시(提示)하였으며 제안된 설계방법의 신뢰성(信賴性)을 규명(糾明)하기 위해 제시된 설계예의 설계조건(設計條件)을 기(旣) 발표된 Hatcher논문의 설계조건과 동일(同一)하게 하여 설계결과(設計結果)를 비교하였다. 그 결과(結果) 이 논문에서 제안(提案)한 설계방법(設計方法)에 따른 설계결과와 Hatcher 논문의 설계결과가 잘 일치(一致)함을 확인할 수 있었다.

  • PDF

자성유체를 이용한 다이나믹형 빙축열 시스템에 관한 실험적 연구 (An Experimental Study of Dynamic Type Ice Storage System Using Magneticfluid)

  • 황승식
    • 대한기계학회논문집B
    • /
    • 제28권12호
    • /
    • pp.1484-1493
    • /
    • 2004
  • In this study, it induced to a conclusion below by experiment consideration to regarding an effective supercooling ends method of the flow cooling water in a tube of continuous ice making method and the static cooling water in a tube of continuous ice making method which used magneticfluid in a dynamic type ice storage system. Continuous ice making in a tube of the flow cooling water was shortened about 12 minutes until supercooling ends that case which gave vertical eccentricity rotation magnetic field 120rpm than did not provide magnetic field by experimental result that was tested to supercooling ends effect from shape control of magneticfluid. Continuous ice making method in a tube of the static cooling water compared with and reviewed the case that was not provided with the magnetic field and exposed cooling surface instantaneously by magnetic field. It confirmed that supercooling degree $\Delta$ $T_{c}$, $\Delta$ $T_{s}$, and $\Delta$ $T_{w}$ became lower because of heat transfering increasing by the occurrence of natural convection between after cooling starting progress time 1∼3 minutes if it did not give a magnetic field, and peformed the supercooling ends when natural convection occurred confirmed that refrigerating capacity was better. That relation $\Delta$ $T_{c}$, and $t_{e}$/($\Delta$ $T_{c}$-$\Delta$ $T_{s}$) after convection occurred, was not depended on $T_{b}$ and initial temperature if the depth of water and thickness of magneticfluid were regular and it was possible to verify conjecture of tp from $\Delta$ $T_{s}$ and $\Delta$ $T_{c}$.lar and it was possible to verify conjecture of tp from $\Delta$ $T_{s}$ and $\Delta$ $T_{c}$.c}$.>.

집중 이동하중을 받는 사장교의 휨 및 비틈 거동에 관한 연구 (A Study on the Bending and Torsional Behaviors of Cable-Stayed Bridges under a Concentrated Moving Load)

  • 장승필;임성순;주석범
    • 대한토목학회논문집
    • /
    • 제9권3호
    • /
    • pp.1-12
    • /
    • 1989
  • 사장교는 경간이 크기 때문에 발생하는 대변형 효과, 케이블의 현수 작용, 그리고 축력으로 인한 휨 강성 변화 등으로 비선형 거동이 나타난다. 사장교의 동적 거동은 구조물 안정성 검사를 위한 중요한 요소가 된다. 특히, 편재 이동하중이 작용하는 경우, 연직 변위와 비틂 변위는 복합될 뿐만 아니라 단면 좌우의 케이블 축력 변화도 중요한 동적 특성을 나타낸다. 본 연구에서는 편재 이동하중이 작용하는 사장교의 해석을 위한 이론적 연구와 유한 요소법을 제시하였고 이동 하중의 속도변화와 편심량의 크기에 따라 케이블의 장력과 절점 변위에 대한 동적 거동을 규명하였다. 본 연구에서 수행한 해석 결과에 따르면, 편재 이동 하중을 받는 사장교의 해석에서는 주형의 비틂과 이로 인한 케이블 축력 증가도 고려해야 할 것으로 사료된다.

  • PDF