• Title/Summary/Keyword: earth wall

Search Result 696, Processing Time 0.024 seconds

Experimental study on effect of underground excavation distance on the behavior of retaining wall

  • Lee, Seok-Won
    • Geomechanics and Engineering
    • /
    • v.17 no.5
    • /
    • pp.413-420
    • /
    • 2019
  • The changes in earth pressure and ground settlement due to underground excavation near an existing retaining wall were studied experimentally according to the separation distance between the underground excavation and the retaining wall. In addition, this study attempted to experimentally prove that the arching phenomenon occurred during the construction of the underground space. A model tank having 120 cm in length, 160 cm in height, and 40 cm in width was manufactured to simulate underground excavation through the use of five separated base wall bodies. The variation of earth pressure on the retaining wall was measured according to the underground excavation phase through the use of 10 separated right wall bodies. The results showed that the earth pressure on the retaining wall was changed by the lowering of the first base bottom wall; however, the earth pressure was not changed significantly by the lowering of the third base bottom wall, since the third base wall had sufficient separation distance from the retaining wall. Lowering of the first base wall induced a decrease in the earth pressure in the lower part of the retaining wall; in contrast, lowering of the first base wall induced an increase in the earth pressure in the middle part of the retaining wall, proving the arching effect experimentally. It is necessary to consider the changes in earth pressure on the retaining wall in designing earth retaining structures for sections where the arching effect occurs.

Investigation on Recently Developed Reinforced Soil Wall System (국내 보강토옹벽 신기술 조사 연구)

  • Lee, Kwang-Wu;Cho, Sam-Deok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.158-167
    • /
    • 2008
  • Reinforced earth wall system has been popularized since its introduction to Korean civil engineering society in early 1980's. Nowadays, the increased use of reinforced earth wall for the purpose of obtaining more land brings several additional demands such as environmental-friendly, better stable and constructible, and economical system. This paper introduces some recently developed reinforced earth wall systems with consideration of the current demands.

  • PDF

An Experimental Study on Passive Earth Pressure of 3-Dimension (3차원 수동토압에 관한 실험적 연구)

  • 김기동;이상덕
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.10a
    • /
    • pp.489-496
    • /
    • 1999
  • The safety of a structure can be improved by applying the three dimensional passive earth pressure. Because the three dimensional passive earth pressure is much larger than the two dimensional passive earth pressure and it is determined by the size(width B and height H) and the wall frictional angle of the resistant wall. Therefore, the three dimensional passive resistance behavior was studied through the model tests in sandy ground, where the size of the resistant wall and the wall frictional angle were varied. The results show that three dimensional passive earth pressure is 1.1∼3.4 times larger than that of the two dimensional value depending on the wall size and the wall friction.

  • PDF

Establishment of Guardrail Distance for Safety of Reinforced Earth Retaining Wall by Vehide Collision (차량충돌에 대한 보강토 옹벽 안전성 확보를 위한 가드레일 설치거리)

  • Park, Kwon;Hong, Ki-Nam;Ahn, Kwang-Kuk
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.5
    • /
    • pp.57-62
    • /
    • 2009
  • In this study, the numerical analyses regarding the distance between the guardrail and the reinforced earth wall as parameter were performed to determine the safe distance of guardrail installed on reinforced earth wall from the reinforced earth wall. The analyses were fulfilled by increasing the distance between the guardrail and reinforced earth wall from 150mm to 750mm. The computer program used in this research is LS-DYNA, which is very' popular in analysis of vehicle collision. Ford single unit truck in NCAC was employed as the model of vehicle and the velocity of vehicle collision was 80km/hr. As a results of analyses, the safety of guardrail was secured regardless of the distance between the guardrail and block of reinforced earth wall. However, to secure the safety of block of reinforced earth wall the distance between the guardrail and block of reinforced earth wall should be over 600mm.

Thermal Performance Evaluation of Earth-Applied Trombe Wall by Simulation (흙을 이용한 트롬월의 열성능 시뮬레이션 평가)

  • Noh, J.H.;Kim, J.T.
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.2
    • /
    • pp.63-71
    • /
    • 2004
  • Energy and environmental concerns accelerate the interest in passive solar heating in buildings, which utilizes solar energy through natural heat transfer. Moreover concerns about environmentally friendly materials were also increased. This study aims to evaluate the thermal performance of a Trombe wall built with earth. The thermal performance of the Trombe walls was analysed with results from computer simulations with TRNSYS 15. The thermal performance of the three types of Trombe wall was compared.: concrete. rammed earth. adobe. It was found that Trombe wall with the thermal storage wall of earth performed better than that of concrete. Rammed earth and adobe Trombe walls gained 4.7% and 12.8% more solar energy. respectively. than the concrete Trombe wall. In earth-applied Trombe walls. the energy gain by natural convection released from the airspace was about 75% of the total solar gains. that took 15% more than concrete Trombe wall. Rammed earth and adobe Trombe walls seem to be more suitable for buildings that use mostly in daytime. such as school, office and so on.

Evaluation of Stability in reinforced Earth Retaining Wall by Vehicle Collision (차량 충돌에 의한 보강토 옹벽의 안정성 평가)

  • Ahn, Kwangkuk;Heo, Yol;Hong, Kinam;Ahn, Minsu
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.6
    • /
    • pp.39-46
    • /
    • 2010
  • The past studies on reinforced earth retaining wall have been mostly focused on the internal and external failure of reinforced earth retaining wall, and the research for external impact was limited on earthquake. However, the potential external impact such as vehicle collision to reinforced earth retaining wall near the road are increasing with development of roads. Therefore, in this study, the reinforced earth retaining wall was modeled by using LS-DYNA, which is a general purpose finite element program recognized for its reliability. The behavior of reinforced earth retaining wall by vehicle speed was analyzed with Ford single unit truck offered by NCAC (National Crash Analysis Center), which is 8 tons weight. In addition, in order to obtain stability of reinforced earth retaining wall for vehicle collision, the gravity retaining wall was applied at the bottom of reinforced earth retaining wall. With varying the height of retaining wall (0.5m, 1.0m, 1.5m), the numerical study was performed to analyze the stability and behavior of reinforced earth retaining wall.

Seismic lateral earth pressure analysis of retaining walls

  • Ismeik, Muhannad;Shaqour, Fathi
    • Geomechanics and Engineering
    • /
    • v.8 no.4
    • /
    • pp.523-540
    • /
    • 2015
  • Based on limit equilibrium principles, this study presents a theoretical derivation of a new analytical formulation for estimating magnitude and lateral earth pressure distribution on a retaining wall subjected to seismic loads. The proposed solution accounts for failure wedge inclination, unit weight and friction angle of backfill soil, wall roughness, and horizontal and vertical seismic ground accelerations. The current analysis predicts a nonlinear lateral earth pressure variation along the wall with and without seismic loads. A parametric study is conducted to examine the influence of various parameters on lateral earth pressure distribution. Findings reveal that lateral earth pressure increases with the increase of horizontal ground acceleration while it decreases with the increase of vertical ground acceleration. Compared to classical theory, the position of resultant lateral earth force is located at a higher distance from wall base which in turn has a direct impact on wall stability and economy. A numerical example is presented to illustrate the computations of lateral earth pressure distribution based on the suggested analytical method.

Effect of the Permeability of Excavation Wall on the Earth Pressure in a Jointed Rock Mass

  • Son, Moorak;Adedokun, Solomon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.2
    • /
    • pp.13-21
    • /
    • 2018
  • The magnitude and distribution of earth pressure on the excavation wall in jointed rock mass were examined by considering different wall permeability conditions as well as rock types and joint inclination angles. The study was numerically extended based on a physical model test (Son & Park, 2014), considering rock-structure interactions with the discrete element method, which can consider various characteristics of rock joints. This study focused on the effect of the permeability condition of excavation wall on the earth pressure in jointed rock masses under a groundwater condition, which is important but has not been studied previously. The study results showed that the earth pressure was highly influenced by wall permeability as well as rock type and joint condition. Earth pressure resulted from the study was also compared with Peck's earth pressure in soil ground, and the comparison clearly showed that the earth pressure in jointed rock mass can be greatly different from that in soil ground.

Design Case Study of Permanent Excavation Wall Using Soil Nailing System (쏘일네일링 공법을 적용한 영구 지하굴착 벽체의 설계사례 연구)

  • Park, Si-Sam;Lee, Je-Man;Yoo, Chan-Ho;Kim, Hong-Taek
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.10a
    • /
    • pp.84-91
    • /
    • 2005
  • In case of soil nailing system, there have been many attempts to expand into slope and temporary earth retaining system stabilization method since the first ground excavation earth retaining system construction in 1993. Recently, jointing wall, underground wall of buildings and excavation earth retaining wall, construction were increasingly applied for effective utilization of the limited underground space and land application maximized. However, the application of joining wall into retaining wall or building by temporary soil nailing system and design of permanent wall were performed by using Rankine earth pressure theory without considering the distribution of earth pressure in the soil nailing. In this study was performed to introduce the design case by 'Two-Body Translation mechanism (TBTM)' to be able to consider distribution of earth pressure in the soil nailing when designing the permanent jointing wall using soil nailing system for effective utilization of ground space. Also, this study attempts to evaluate the earth pressure change, decreasing effect of wall displacement and increasing effect of stability when advanced soil nailing system is constructed using $FLAC^{2D}$ ${\nu}er.$ 3.30 program and 'Two-Body Translation mechanism'.

  • PDF

Field Measurements of Cantilever Wall with Unattached Strips in the Backfill (뒷채움 지반에 비정착식 띠보강재를 설치한 역T형 옹벽의 현장 계측)

  • 이종구;이만수;김명모
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.87-94
    • /
    • 2000
  • This paper concerns the distribution of earth pressures on a cantilever wall with unattached reinforcements in the backfill. This type of walls is different from the existing reinforced earth walls in that unattached reinforcements are placed in the backfill of rigid retaining wall such as gravity wall and cantilever wall, instead of connecting reinforcements to the wall segments. Two large-scale prototype tests have been carried out with a 4m high cantilever wall; one with unreinforced backfill, the other with unattached strips in the backfill. The reinforcing effect of unattached strips are discussed based on the earth pressure distribution measured in two large-scale prototype tests. Also, the comparison between measured and predicted earth pressure on a wall with unattached strips are discussed herein to confirm the validity of analytical prediction.

  • PDF