Field Measurements of Cantilever Wall with Unattached Strips in the Backfill

뒷채움 지반에 비정착식 띠보강재를 설치한 역T형 옹벽의 현장 계측

  • 이종구 (서울대학교 지구환경시스템공학부) ;
  • 이만수 (현대건설 기술연구소) ;
  • 김명모 (서울대학교 지구환경시스템공학부)
  • Published : 2000.11.01

Abstract

This paper concerns the distribution of earth pressures on a cantilever wall with unattached reinforcements in the backfill. This type of walls is different from the existing reinforced earth walls in that unattached reinforcements are placed in the backfill of rigid retaining wall such as gravity wall and cantilever wall, instead of connecting reinforcements to the wall segments. Two large-scale prototype tests have been carried out with a 4m high cantilever wall; one with unreinforced backfill, the other with unattached strips in the backfill. The reinforcing effect of unattached strips are discussed based on the earth pressure distribution measured in two large-scale prototype tests. Also, the comparison between measured and predicted earth pressure on a wall with unattached strips are discussed herein to confirm the validity of analytical prediction.

Keywords