• Title/Summary/Keyword: dual-wavelength

Search Result 127, Processing Time 0.031 seconds

Measurement of Transverse Strain Using Polarization Maintaining Fiber Bragg Grating Sensor (편광 유지 광섬유 브래그 격자 센서를 이용한 횡방향 변형률 측정)

  • Yoon, Hyuk-Jin;Kim, Dae-Hyun;Hong, Chang-Sun;Kim, Chun-Gon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.6
    • /
    • pp.30-35
    • /
    • 2003
  • In this paper, the transverse strain was measured using polarization maintaining fiber Bragg grating(PMFBG) sensor. PMFBG sensor was fabricated using phase mask and Excidmer laser. The reflected wavelength of PMFBG sensor had dual peaks due to intrinsic birefringence. To find the polarization axes, peak sensitivity was measured under compression test. The signal characteristics of PMFBG sensor were also examined in embedding condition. The embedded PMFBG sensor in epoxy block was loaded for the transverse strain measurement, The wavelength-swept fiber laser(WSFL) was used to construct the PMFBG sensor system. Experiments showed that the PMFBG sensor could successfully measure the transverse strain.

320km Optical Transmission using EDFA and Raman amplifier for 10Gbit/s 128 Channel DWDM Signals (10 Gbit/s 128 채널 고밀도 파장다중화 신호를 위해 EDFA와 라만 증폭기를 이용한 320km 광전송 실험)

  • Choi, Bo-Hun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.6B
    • /
    • pp.568-574
    • /
    • 2009
  • 320km optical transmission link for 128 channel DWDM (dense wavelength-division-multiplexing) signals is simulated and fabricated. An optical fiber amplifier for the link is composed of a distributed Raman amplifier and dual C/L-band EDFAs which are optimized for the performances of an optical amplifier obtained from the simulation. Gain and NF of the optimized EDFAs are above 19dB and below 7.5dB, respectively. The resultant OSNRs (optical signal to noise ratios) of the link are average 25dB on each band.

Development of Fast-Response Portable NDIR Analyzer Using Semiconductor Devices

  • Kim, Woo-Seok;Lee, Jong-Hwa;Park, Young-Moo;Yoo, Jai-Suk;Park, Kyoung-Seok
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.12
    • /
    • pp.2099-2106
    • /
    • 2003
  • In this paper, a novel fast response NDIR analyzer (FRNDIR), which uses an electrically pulsed semiconductor emitter and dual type PbSe detector for the PPM-level detection of carbon dioxide (CO$_2$) at a wavelength of 4.28 $\mu\textrm{m}$, is described. Modulation of conventional NDIR energy typically occurs at 1 to 20 Hz. To achieve real time high-speed measurement, the new analyzer employs a semiconductor light emitter that can be modulated by electrical chopping. Updated measurements are obtained every one millisecond. The detector has two independent lead selenide (PbSe) with IR band pass filters. Both the emitter accuracy and the detector sensitivity are increased by thermoelectric cooling of up to -20 degrees C in all semiconductor devices. Here we report the use of semiconductor devices to achieve improved performance such that these devices have potential application to CO$_2$ gas measurement and, in particular, the measurement of fast response CO$_2$ concentration at millisecond level.

Comparison of In-Plane Measurement of Phase-Shifting with Time-Average Method (위상이동법과 시간평균법의 면내변위 측정 비교)

  • Kim, Kyoung-Suk;Kim, Dong-Iel;Jung, Hyun-Chul;Kang, Ki-Soo;Lee, Chan-Woo;Yang, Seung-Pil;Jarng, Soon-Suck
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.10
    • /
    • pp.53-58
    • /
    • 1999
  • Even I the Electronic Speckle Pattern Interferometry(ESPI) method that measure the strain of object within wavelength of light is less visibility than Holographic Interferometry(HI) method, the merits of application, convenience and time-save have made the method practical in industry. However, the existing ESPI methods that are based on dual-exposure, real-time and time-average method have difficulties for accurate measurement, due to irregular intensity and shake of phase. Recently, in order to solve this problem, phase shifting method have been proposed. In this method, the path of reference light in interference is shifted to make improvement in distinction and precision. But this method includes too many noise, caused by the problem of relationship between object and phase. Therefore, a method to reduce noise muse be introduced. In this paper, least square fitting method is proposed. As results, the phase-map is influenced by precise phase shifting and current of notes and speckle pattern obtained by phase shifting method is improved on the existing method driven from time-average method.

  • PDF

Design of Cover Layer Incident Dual-Layer Near-Field Recording Optics with Hemispherical SIL (반구형 SIL을 이용한 미디어 내부 이층 근접장 광 기록계의 설계)

  • Kim Wan-Chin;Choi Hyun;Song Taesun;Park No-Cheol;Park Young-Pil
    • 정보저장시스템학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.4-11
    • /
    • 2005
  • In this paper, we propose novel optics design for media inside near-field recording (NFR) using hemispherical solid immersion lens (HMS). To obtain strong advantage of data protection and high data capacity simultaneously, HMS based near field optics using aplanatic position of super hemisphere is designed. In this design, to improve small optical tolerance of this aplanatic position, additional aspheric lens surface is added on top of the HMS and it is combined with zoom optics which composed of two single lenses having low numerical aperture (NA). Also, to compensate chromatic aberration which happens seriously in optics using blue laser diode, diffractive optical element is used. Using zoom optics, additional aspheric lens surface, and diffractive optical element together, wavefront aberration and chromatic aberration are effectively reduced in broad range of cover layer thickness and wavelength variation. In addition, In this paper, effect of gap induced aberration is investigated by analyzing different behavior of each TM and TE wave for designed media inside dual-layer NFR optics.

  • PDF

Design of Cover Layer Incident Dual-Layer Near-Field Recording Optics with Hemispherical SIL (반구형 SIL을 이용한 미디어 내부 이층 근접장 광 기록계의 설계)

  • Choi, Hyun;Kim, Wan-Chin;Song, Tae-Sun;Park, No-Cheol;Park, Young-Pil
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.1
    • /
    • pp.13-20
    • /
    • 2006
  • In this paper, we propose novel optics design for media inside near-field recording(NFR) using hemispherical solid immersion lens(HMS). To obtain strong advantage of data protection and high data capacity simultaneously, HMS based near field optics using aplanatic position of super hemisphere is designed. In this design, to improve small optical tolerance of this aplanatic position, additional aspheric lens surface is added on top of the HMS and it is combined with zoom optics which composed of two single lenses having low numerical aperture(NA). Also, to compensate chromatic aberration which happens seriously in optics using blue laser diode, diffractive optical element is used. Using zoom optics, additional aspheric lens surface, and diffractive optical element together, wavefront aberration and chromatic aberration are effectively reduced in broad range of cover layer thickness and wavelength variation. In addition, in this paper, effect of gap induced aberration is investigated by analyzing different behavior of each TM and TE wave for designed media inside dual-layer NFR optics.

  • PDF

Standard Calibration for Broadband and Narrowband Filters of KHAO 0.4 m Telescope

  • Ahn, Hojae;Jeong, Inhwan;Paek, Gregory S.H.;Lee, Sumin;Kim, Changgon;Pak, Soojong;Shim, Hyunjin;Im, Myungshin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.2
    • /
    • pp.76.1-76.1
    • /
    • 2021
  • Maemi Dual Field Telescope System (MDFTS) is a dual telescope system located at Kyung Hee University. The system consists of 0.4 m telescope and 0.1 m telescope for wide-field observation. The 0.4 m telescope provides photometric observation which covers a field of view of 21'×16'. It has been used for various purposes with Johnson-Cousins UBVRI broadband filter system, e.g., SomangNet and Intensive Monitoring Survey of Nearby Galaxies. In this poster, we present the standard calibration result for our broadband filter system. Also, we suggest a new usage of the KHAO 0.4m telescope which is narrowband photometry by demonstrating the standard calibration of H-alpha filter. For flux calibration, not only R filter but also V filter is used for compensating the central wavelength discrepancy between R filter and H-alpha filter.

  • PDF

Changes of the surface hardness and the light transmittance of PET film by ion implantations (이온 주입에 의한 PET막의 표면경도변화 및 광 투과도 변화)

  • 박재원;이재형;이재상;장동욱;최병호;한준희
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.2
    • /
    • pp.241-246
    • /
    • 2001
  • Single or dual ion implantations were performed onto the transparent polyethylene terephthalate(PET) sheet, and the surface hardness and the light transmittance in the visual-UV range were examined. Nanoindentation showed that the surface hardness was the highest at about 50 nm depth from the surface and was increased by about 3 times when nitrogen ions were implanted with energy and dose of 90 keV and $1\times10^{15}\textrm{/cm}^2$ respectively. When dual ions such as He+N and N+C ions were implanted into PET, the hardness was increased even more than the case only N ions were implanted. Especially, when PET were implanted with N+C dual ions, the surface hardness of PET increased 5 times more as compared to when implanted with N ions alone. The light at the 550 nm wavelength(visual range) transmitted more than 85%, which is close to that of as-received PET, and at the wavelength below 300 nm(UV range) the rays were absorbed more than 95% as traveling through the sheet. implying that there are processing parameters which the ion implanted PET maintains the transparency and absorbs the UV rays. It can be considered that the increase in the hardness of polymeric materials is attributed to not only cross linking but also forming hard inclusions such as hard C-N compounds, as evidenced by the formation of the highest hardness when both N and C ions are implanted onto PET.

  • PDF

Effect of Gain Dispersion on the Characteristics of Self-Pulsation in a Multisection Complex-Coupled DFB Laser (이득 분산이 다중 영역 복소 결합 DFB 레이저의 Self-Pulsation 특성에 미치는 효과)

  • Kim, Tae-Young;Kim, Boo-Gyoun
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.1
    • /
    • pp.56-65
    • /
    • 2007
  • The effect of gain dispersion on the self-pulsation (SP) characteristics due to the mode beating of two modes emitted in a multisection DFB laser composed of two complex-coupled DFB sections and a phase control section is investigated. When the peak wavelength, ${\lambda}_{p}$, of the gain spectrum of the DFB section is positioned in the center of the lasing wavelengths or the Bragg wavelengths of the two DFB sections, the maximum SP frequencies are higher and the modulation index has better characteristics compared to those cases for ${\lambda}_{p}$ fixed at the lasing wavelength or Bragg wavelength of one DFB section, when the difference between the Bragg wavelengths of the two DFB sections, ${\Dalta}{\lambda}_{B}$, is varied. When ${\lambda}_{p}$ is positioned in the renter of the Bragg wavelengths of the two DFB sections, the maximum SP frequency is higher and of the modulation index has better characteristics compared to those of the case for ${\lambda}_{p}$ positioned in the center of the lasing wavelengths of the two DFB sections.

Comparison of Scattered Light of ex vivo Mouse Neutrophils by Different Wavelength Laser Irradiation (2개의 레이저 파장에 따른 마우스 호중구의 산란광 비교 연구)

  • Park, Jae-Sung;Son, Min-Ji;Hwang, Chang-Soon;Lee, Ho
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.3
    • /
    • pp.365-378
    • /
    • 2022
  • Complete blood cell count(CBC) is a technique that counts leukocytes for each type of blood cell being analyzed. The principle is that laser is incident to ex vivo flowing leukocytes in a microcapillary tube and scattered light occurs by laser and leukocytes. By collecting the scattered light, we can count the types of cells because different cells generate different light-scattering patterns. However, the technique has an intrinsic limitation, scattering pattern is shown in a wide range region in the resulting, which makes it difficult to accurate analyze and use fluorescent dyes. To overcome this limitation, a new design of CBC with a dual laser, which irradiates with orthogonal angles for collecting quad-scattering information was proposed. Before development, the scattering difference depending on wavelength must be investigated to only catch up to the scattered signal by angles. Some studies, which focused on simple particles, have been conducted to theoretically and experimentally investigate different scatterings by wavelength. In this study, we propose an optical system for measuring scattered light and investigate a complex particle. As a result, the green laser made strong scattering signals in both the forward and side direction: 10% and 30%, respectively.